Home
Nortel Networks V210 User's Manual
Contents
1. SNMP request port 9161 default SNMP agent IP address either the word 120 120 13 22 localhost or the machine logical IP address of the database server that this Oracle Monitor is running on Oracle Server name imsdb1 default Active checked default Monitor functions Generallnfo default Handler name Monitor functions 1 default Polling interval min Active checked default Monitor functions OperationalStatus default Handler name Monitor functions 1 default Polling interval min Active checked default 2 Use the values from the table that follows to complete the IMS Main Database tab parameters NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 143 The shaded rows indicate values that must be addressed by the installer Table 37 IMS Main Database tab Sheet 1 of 4 SNMP request port 9161 default SNMP agent IP address lt either the word 120 120 13 22 localhost or the machine logical IP address of the database server that this Oracle Monitor is running on gt Oracle Server name imsdb1 default Oracle Database name imsdb1 default Active checked default Component name TableSpace default Polling interval min 1 default Active checked default Gauged Component percentageUltilization default Monitoring Threshold monitors Gauge name Gauged Component 100 default Monitoring Threshold monitors Upper limit Gauge
2. ATTENTION Perform these steps on all servers in parallel if multiple CDs are available Installing Oracle 9 2 0 4 Procedure 20 Installing Oracle 9 2 0 4 on the database server DBSvr At the management pc 1 2 3 Use PuTTY to connect to the database server using Serial MGT port which connects to the LX terminal server Log in as root to the Management Accounting server Enter your lt customer specific password gt Enable the CD ROM auto mount by typing the following command etc init d volmgt start You will see the message volume management starting Insert Oracle 9 2 0 4 CD 1 into the CD ROM drive on the server cd space cdrom cdrom0 Enter MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 72 7 ATTENTION Make sure you put a space before the ending slash in step 5 cp space Install_CD_to_Disk space Enter 8 cd space Enter 9 Install CD to Disk Enter 10 Storing data from CDs to the IMS ora cds directory Y Select Y Enter Note The data from the CDs is copied to the default directory unless the required disk space is not available 3 5 GB on the IMS partition If a directory is entered it must either be a new directory or empty This allows for easy removal of files later 11 Please insert Oracle Disks 2 6 into the CD ROM drive Enter Note You will receive the followin
3. 129 PIGIGQUISIIDS uueckzebrertereses9442 dq Xxx ard am ue dor aca me Rees 129 Procedures os 5 LR dE NE Ci DEN tee Ei buda edt 129 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 5 Adding and configuring the Web Client Manager 135 Prerequisites 2 eee rn 135 Procedures in Si Dh 135 Installing and configuring the Oracle Monitor 141 Prerequisites 2s 29 eka dees RR EET 141 lues 141 Installing the iPlanet Monitor 149 Prerequisites oaosaesaad acm pu pg iu daleta Cesk eee ee eyelets dires 149 Procedures onde chat td PERC onde ee Oho DENSE eRe Reh cece eh aes 149 Verification procedures 163 Verifying Server1 DBSvr MgmtSvr AcctMgr 163 Verifying Server2 application server 165 Verifying the database load imssipdb deployment 167 Deploying the PC Client 169 Reloading IP addresses after system installation 171 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 6 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Maletolere gt 9 O1 Copyright Nortel Networks Limited 2006 Finding the latest updates on the Nortel
4. Invite Timer 128000 default Maximum Numberof 5 default Redirections Initial Maximum Hop 20 default Value 2 Use the values from the table that follows to complete the User Agent Server tab parameters The shaded rows indicate values that must be addressed by the installer Table 25 User Agent Server tab Application Server 5060 default Port Click to call 18 default Cancel Delay NN42020 310 MCS 51003 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 131 3 Use the values from the table that follows to complete the Web Client Manager tab parameters The shaded rows indicate values that must be addressed by the installer Table 26 Web Client Manager tab WCM Socket Server Active checked checked WCM Socket Server Host lt machine logical IP 120 120 12 43 address of the Web Client Manager gt WCM Socket Server Port 3090 default Audio RTP Port Low 50000 default Audio RTP Port High 50100 default Use SSL checked default Keep Alive Ping checked default Ping Time Out Timer 60 default Ping Interval Timer 120 default Download JRE Version This field holds the version of the Java Runtime Environment JRE installer that the Web Client applet downloads For the latest version of the installer from Sun leave this field empty For the installer provided by the MCS The MCS currently provides 5 different JRE installers use string 1 4 2
5. Component Monitoring checked default Active for polling Component Monitoring cpuUserTime default Threshold monitors Gauge name Component Monitoring 100 default Threshold monitors Upper limit Component Monitoring 0 default Threshold monitors Lower Limit Component Monitoring 10 default Threshold monitors Negative going threshold value Component Monitoring 5 default Threshold monitors Negative going threshold hysteresis Component Monitoring 70 default Threshold monitors Positive going threshold value 1 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 1 Component Monitoring 85 default Threshold monitors Positive going threshold value 2 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 157 Table 40 Web Monitor tab Sheet 8 of 12 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 2 Component Monitoring 99 default Threshold monitors Capacity or max value Component Monitoring 0 default Threshold monitors Capacity or max hysteresis Component Monitoring NONE default Threshold monitors Alarm Severity on Negative going threshold Component Monitoring WARNING default Threshold monitors Alarm Severity on Positive going threshold 1 Component Monitoring MINOR default Threshold monitors Alarm Severity on P
6. Adwanced Search Site Man 7 Select Create to register a new system The following screen appears MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 84 Figure 20 Keycode Retrieval System Entering your site information Your Location Home Customer Support Keycode Retrieval MCP Product Registration Customer Support Keyc de Retrieval System Register Product Control Product Registration This section enables you to register new products into the Keycode Retrieval Gen KC with Auth Code System so that you can add or transfer features to the product in the future Gen Temp Keycode Retrieve Keyeoge Retrieve History USER Best Customer TYPE Support User User GROUP All Customer Groups Help Terms amp Conditions Step Fill in your site information and click the Continue button Required Field You can contact usat SITE NAME North America Enter your company identifying name for your Site 1 800 4 NORTEL 1 800 466 7835 VERSION 112 International Contacte CITY COUNTRY select country STATE PROV select state province Continue Cancel 8 Fill in the requested information and press the Continue button Ensure you choose the correct software version from the dropdown box Your screen should look like the one in the following figure NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006
7. MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 126 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing the UFTP BaseSoftware You will be installing the UFTP software on the application server Prerequisites The System Management Console has been successfully installed and started Note This procedure also assumes that the IP Client Manager IPCM component was deployed successfully the UFTP software therefore can interact with the IPCM for firmware Add the UFTP to the System Management Console Procedure 34 Adding the UFTP software At the System Management Console 1 Select Sites gt MgmtSite gt AppSvr 2 Click on the plus sign next to the component to which you are adding the base software 3 Right click on the Components folder 4 Select Add gt BaseSoftware 5 A list of loads appears in the pop up window Select the latest UFTP load 6 Click Apply Note The UFTP BaseSoftware has no configuration items Once the installer clicks Apply the deployment of the UFTP BaseSoftware occurs immediately Once the deployment is complete UFTP will appear in the System Management Console file tree MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 128 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyrig
8. use string 1 4 2_01 1 4 2 02 1 4 2 03 1 4 2 04 or 1 4 2 05 for the corresponding installer for JRE version 1 4 2 01 1 4 2 02 1 4 2 03 1 4 2 04 or 1 4 2 05 You may also provide a different JRE installer filename has to be j2re windows i586 p exe in the JRE installer directory which is the IMS web data web webapps pca data jar directory on the server where the Provisioning Module runs In this case use any other version string such as 1 4 2 06 This field should not contain white space 4 Use the values from the table that follows to complete the Conference Service tab parameters The shaded rows indicate values that must be addressed by the installer Table 34 Conference Service tab 5 Use the values from the table that follows to complete the Database Base tab parameters NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 139 The shaded rows indicate values that must be addressed by the installer Table 35 Database Base tab 6 Click Apply 7 The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 140 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing and configuring the Oracle Monitor
9. 1 Select Sites gt MgmtSite gt Servers gt Add gt General gt AppSvr See Adding a server on page 103 for information on how to add a server before adding the AppSvr Click on the plus sign next to the server to which you are adding the component Right click on the Components folder Select Add gt Component A list of component loads appears in the Load List window Select the latest Small SharedMicro load Click Apply Wait for the new component and the component configuration window to appear Enter a label maximum six 6 characters in the Service Component Name field at the bottom of the configuration window The Service Component Name must be unique among all components Example IPCM1 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 122 Procedure 33 Configuring the IP Client Manager tabs ATTENTION Do not click Apply until you have finished configuring the component At the System Management Console 1 Use the values from the table that follows to complete the IP Client Manager tab parameters Note The shaded rows indicate values that must be addressed by the installer Table 17 IP Client Manager tab Sheet 1 of 2 Locales en_US default Max Number Devices 2000 default Max Login Duration 2678400 default Overflow Server 0 0 0 0 default DB Update Interval 120 default Auto Provisioning check
10. 77 Sysmgr deployment verification 79 Registering your license key 81 Installing and launching the System Management Console 97 mic a 24a dtd HA ee he des alk ak ie He eee om wae Eang ES 97 Installing the System Management Console 97 Launching the System Management Console 98 Adding a Server sic seu due geste benne 103 PICICQUISICS sace ini Steere eeene dee beveddepewes died a R aao 103 Adding a server o2565 02600 cie nananana d RE meet tic etienne 103 Adding and configuring the Accounting Module 105 Prereg isitesS 5 ce ani e CR eater oss FERS hee eka tenons 105 PIOCCGUIGS uu uso Enea RO UR EUER UON HERO OU ICE 8 9 T dnd 105 Adding and configuring the SIP Application Module 109 Prerequisites Gwadct ncn tae ageda sede cick RR NS UK A abu ab ne rene 109 Procedures exutus peace cea RR IDE RIRUR ER tenaient 109 Adding and configuring the IP Client Manager 121 Prerequisites 42925999 teeta 9 Gent OR T9899 903 8 4 soda an oes eke 121 Proced reS cocardvne neve se daceueeeas th RE KERES SENSE DERES 121 Installing the UFTP BaseSoftware 127 PISISQUISHOS norite eureen RE ao ACE eR cre Roa eL CEA IC Rr do E 127 Add the UFTP to the System Management Console 127 Configuring the Provisioning Module
11. Component Monitoring NONE default Threshold monitors Alarm Severity on Negative going threshold Component Monitoring WARNING default Threshold monitors Alarm Severity on Positive going threshold 1 Component Monitoring MINOR default Threshold monitors Alarm Severity on Positive going threshold 2 Component Monitoring MAJOR default Threshold monitors Alarm Severity on Maximum Rate Component Monitoring MAJOR default Threshold monitors Alarm Severity on Upper Limit OverRun Component Monitoring MAJOR default Threshold monitors Alarm Severity on Lower Limit UnderRun Component Monitoring unchecked default Threshold monitors Usage state affected Component Monitoring percentKeepAliveQue default Threshold monitors ueUsage Gauge name Component Monitoring 100 default Threshold monitors Upper limit Component Monitoring 0 default Threshold monitors Lower limit NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 153 Table 40 Web Monitor tab Sheet 4 of 12 Component Monitoring 10 default Threshold monitors Negative going threshold value Component Monitoring 5 default Threshold monitors Negative going threshold hysteresis Component Monitoring 70 default Threshold monitors Positive going threshold value 1 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis
12. IrGofwE 4 1232860uR5BretY TEQGS1 61F3 A8 gXnL Le qe 606 103 TpAxxpI ETT eVo 1080 te keXa TPI low vh TZ VEN SD Lb4Sx4eOyDerTu24KEq7aIEn0SdnPo5SByOut evya6n55nuna Downoad Kayod 24 Download the new license key file to the MgmtSvr hard drive MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 96 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing and launching the System Management Console Prerequisites Make sure that The dbdeploy p1 script has been successfully executed The mgmtdeploy pl script has been successfully executed The Sysmgr is started The license key is registered Installing the System Management Console Procedure 25 Installing the System Management Console At the management pc 1 2 8 9 10 11 Put the MCS Base Platform System Software CD MCS Management Console PC software into the PC s CD ROM Navigate to the CD ROM drive and double click on the executable mcpmc_setup exe To install the System Management Console click Next To select default program folder click Next Enter the lt SysMgr service logical IP address gt Example 120 120 13 22 Click Next Enter the System Management server port Keep the default 11111 Click Next Keep default destination folder Click Next Review settings before copying files MCS 2 server Sun Fire V210
13. NN42020 310 Multimedia Communication Portfolio Multimedia Communication Server 2 server Sun Fire V210 ROHS Solaris Installation and Commissioning Guide MCS 51003 5 Standard 1 0 June 2006 NORTEL Copyright Nortel Networks Limited 2006 3 Contents How to get help ee i OR n DR a 9 OVErVIEW uo ne eme als e NER BUR EUR IRR NR ao toto RU i d orem ec d 11 Restrictions and limitations 13 MCS 5100 documentation 1a onu a ane stands OR R re nodes 14 Before you start the installation 17 PEOIOBUISIIES A nn tan ne he RE CI p ERROR Rar doi 17 sri PF Re Rei yh a Riel gh Te te ee AS OA Al och Aceh st Bi 18 Key stroke symbols 19 Text conventions used in this document 19 Server configuration 20 LOSING CISKS oe ce tote oo e e qe Ele aea ak ee S9 RR CR CR c erae Woke we 20 Minimum and recommended requirements for customer provided PC 23 Setting up the baseline hardware 25 Baseline hardware 6x ac LM a e T DACIA LE a disi end 25 Setting up rack to mount hardware 27 Connecting the Sun Fire V210 server to the layer 2 switch 28 Connecting the Sun Fire V210 server to the MRV LX terminal server 30 Installing and accessing the MRV LX 4000 series termin
14. Press key indicated in brackets Text conventions used in this document This document uses the following text conventions e Bolded type is used to signify commands or buttons that you must press to perform an action for example Apply e Courier type is used to signify what appears on screen for example Enter your password e Italic type is used for emphasis for special words or for reference information for example Log in as root MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 20 Server configuration The following table shows the basic configuration of the 2 server V210 Solaris system Table 1 2 server configuration 2 server V210 Solaris Server1 Active System Manager Active Accounting Manager Primary database Oracle Monitor Server2 IPCM S1 Active Provisioning Module Active SIP Application Module Active WebClient Manager iPlanetMonitor UFTP Base Software Loading disks MCS 5100 Release 3 0 Base Platform System SoftWare Kit NTVWO1AJ contains multiple copies of the same CDs to allow simultaneous installation across servers See Table 2 Mapping of Kit NTVWO1BD disks to servers with times on page 21 for details Nortel Networks recommends that you install the same CDs on both servers at the same time to reduce installation time As shown in Table 2 Mapping of Kit NTVWO1BD disks to servers with times Disk
15. Product Control Product Registration This section enables you to register new products into the Keycode Retrieval Gen KC with Auth Code System so that you can add or transfer features to the product in the future Retrieve Keycode Retrieve History USER Best Customer TYPE Support User User GROUP All Customer Groups Help I Conditions Current Summary SITE NAME NORTEL LAB 200 VERSION 1 1 CITY Richardson North America 1800 4 NORTEL COUNTRY UNITED STATES 1 800 466 7835 STATE PROV Texas You can contact us at Intemational Contacts Step Add systems to the site by selecting the type and clicking the Create button Click the Continue button when you are done CORE CORE ACTION 00 04 47 36 01 1A Add Cancel 11 Repeat Step 10 for the second MAC address required If you make an error you can remove one or both and begin again If you have a second Core that is going to be installed as a redundant server enter all four MAC addresses at this time 12 When finished you will need to select Create again to enter the Media Application Server s MAC addresses enter those just as you did in Step 10 13 Enter both MAC addresses of the Media Application Server if you are installing one and click Continue For more information on the Media Application Server refer to the Media Application NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited
16. Rel3 NTme pids mgmtsvr mgmtsvr 3 xxxx Rel3 NTme pids tsscma tsscma 5 xxxx Rel3 NTme pids tssfpma tssfpma 6 xxxx Note The numerical value of the PIDs is shown as xxxx because it may vary on each system The results of the meinit command should display three processes along with their process ids MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 80 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Registering your license key Before installing the license key as described in Procedure 25 Installing the System Management Console follow the procedure below to generate and register your license key Procedure 24 Registering the license key At the management pc 1 Before you can begin generating keycodes first Register or create your site on the KRS Keycode Retrieval System webpage The site will normally consist of one or two Management and Accounting servers this set is called the CORE and one or more Media Application Servers MAS Each server has two 2 MAC addresses First identify those MAC addresses since you will need to identify them to the KRS during the site registration process The following screen shots show a simple configuration and generation of one keycode for the Management and Accounting servers CORE Open your browser and go to www nortel com Internet access is r
17. use the following command etc init d volmgt stop MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 68 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 meererele gt e O1 Copyright Nortel Networks Limited 2006 Installing Disk 6 MgmtSvr AcctMgr only ATTENTION CD6 must be installed on the MgmtSvr and on the AcctMgr machines only If you do not install CD6 you will not be able to deploy or start the secondary MgmtSvr or AcctMgr Approximate time estimate 30 minutes Procedure 19 Installing CD 6 At the management pc 1 Place CD6 in the CD ROM drive on the server and press Enter at the prompt Note CD6 will eject from the CD ROM when installed 2 After the reboot log in using the Serial MGT port and change the passwords for the sysadmin root and nortel users MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 70 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing Oracle 9 2 0 4 on the database server The procedures to install Oracle 9 on the DBSvr include storing Oracle 9 CDs 1 6 to your local hard drive Refer to the section that follows Approximate time for loading Oracle 9 90 minutes ATTENTION Refer to the CSI datasheet for such items as the hostname IP addresses and subnet masks
18. 1 Component Monitoring 85 default Threshold monitors Positive going threshold value 2 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 2 Component Monitoring 99 default Threshold monitors Capacity or max value Component Monitoring 0 default Threshold monitors Capacity or max hysteresis Component Monitoring NONE default Threshold monitors Alarm Severity on Negative going threshold MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 154 Table 40 Web Monitor tab Sheet 5 of 12 Threshold monitors WARNING default Alarm Severity on Positive going threshold 1 Threshold monitors MINOR default Alarm Severity on Positive going threshold 2 Component Monitoring MAJOR default Threshold monitors Alarm Severity on Maximum Rate Component Monitoring MAJOR default Threshold monitors Alarm Severity on Upper Limit OverRun Component Monitoring MAJOR default Threshold monitors Alarm Severity on Lower Limit OverRun Component Monitoring unchecked default Threshold monitors Usage state affected Component Monitoring percentSysMemUsag default Gauge name e Component Monitoring 100 default Upper limit Component Monitoring 0 default Lower Limit Component Monitoring 10 default Negative going threshold value Component Monitori
19. 40 Database queue low threshold 1 default Protocols Monitored Sip default 15 Use the table that follows to modify the fields for the Transport Management tab The shaded rows indicate values that must be addressed by the installer Modify the public fields only There are no private addresses Table 16 Transport Management tab Sheet 1 of 3 Service Name BBUA default Server ID lt specific to machine gt App1 Server ID 1 App2 Server ID 2 Standalone Server checked Server Parameter Public_Static_Address default Label Server Parameter lt machine logical IP of Enter the machine 120 120 Value application server gt logical IP of the 13 25 application server you are working on HeartBeat Port 40001 default Sending Interval 250 default HeartBeat Timeout 3 default MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 118 Table 16 Transport Management tab Sheet 2 of 3 Discovery Period default Active Pending Period default Number NSD Enabled Label Public_Service_Address Local Server Public_Static_Address default Address Parameters NSD 1 default default Parameters Service checked Check the first two default Parameter Transport Enabled Transport Enabled boxes for UDP and TCP that display Uncheck all subseque
20. 52 21 Wait until you receive the login prompt You will be prompted to type in the root password twice The password will not appear on the screen when you type If you do not want a root password press Enter twice Press Enter to continue Note The CD will eject from the CD ROM The system then requests that you insert CD2 ATTENTION If you are not prompted for CD2 contact support Installing CD2 Approximate time estimate 15 minutes Procedure 13 Installing CD2 At the management pc 1 Place CD2 in the CD ROM drive and press Enter You will see a number of messages requiring no specific answer Press Enter following each one You will then see the following message What type of installation are you performing 1 Typical 2 Customlype 1 and press Enter You will then see the following message Ready to Install Install Now Start Over Exit Installation Type 1 for Install Now and press Enter Press Enter several more times to complete the License Agreement Enter Y to accept the license Note You will now see a progress bar showing percent of installation completed You will then be asked to choose 1 for Live Install or 2 for Done Accept the default 2 Done by pressing Enter Note 1 CD2 will eject from the CD ROM drive when installed Note 2 The system will reboot and come up requesting that you insert MCS Base Platform System Software CD3 ATTENTION If you are not prompted for CD
21. 800 4 NORTEL 1 800 466 7835 Feature Profile for CORE International Contacts FEATURE INSTALLED NEW Database server None Server None IPCM SubRefLimit None IPCM None Application server None Personal Agent feature Continue Cancel None El Mime 7 23 The KRS will indicate it is generating your keycodes and saving the results in its database After generating the keycodes and saving results in the KRS database the system shows the Retrieve Keycode page where you can view the features enabled for the server From this page you will be able to download the keycode see the figures below MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 94 Figure 30 Keycode Retrieval System Retrieving the keycode A Nortel Networks Customer Support Keycode Retrieval System Retrieve Keycode Microsoft Interneti File Edit View Favorites Tools Help Bak Q A Bsearch Favorites History B amp K3 a 9 Address ei http zcarsOss ca nortel com nortelnetworks eservice eld jsps retrieve_keycode2 jsp gt Go Links Customer 5 Support Home Customer Support Survey Product Control 5 Retrieve Keycode Retrieve History Reset Auth Code Feature s Management Administration Terms amp Conditions You can contact us at North America 1 800 4 NORTEL 1 8
22. Adding an Accounting Module component to the server At the System Management Console 1 Select Sites gt MgmtSite gt Servers gt Add gt General gt MgmtSvr See Adding a server on page 103 for information on how to add a server before adding the AcctMgr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Components folder 4 Select Add gt Component 5 A list of component loads appears in the Load List window Select the latest Small load 6 Click Apply Wait for the new component and the component configuration window to appear 7 Enter a label maximum six 6 characters in the Service Component Name field at the bottom of the configuration MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 106 window The Service Component Name must be unique among all components Example acct1 Procedure 29 Configuring the tabs At the System Management Console 1 Use the values from the table that follows to complete the Central Accounting Manager tab parameters Note The shaded row indicates values that must be addressed by the installer Table 1 Central Accounting Manager tab Sheet 1 of 2 CAM IP Address lt machine logical IP 120 120 13 22 address of host server gt Primary CAM Port 17667 default Recovery CAM 17668 default Port File Rotation Size 100000 Configurable d
23. June 2006 Copyright Nortel Networks Limited 2006 159 Table 40 Web Monitor tab Sheet 10 of 12 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 1 Component Monitoring 85 default Threshold monitors Positive going threshold value 2 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 2 Component Monitoring 99 default Threshold monitors Capacity or max value Component Monitoring 0 default Threshold monitors Capacity or max hysteresis Component Monitoring NONE default Threshold monitors Alarm Severity on Negative going threshold Component Monitoring WARNING default Threshold monitors Alarm Severity on Positive going threshold 1 Component Monitoring MINOR default Threshold monitors Alarm Severity on Positive going threshold 2 Component Monitoring MAJOR default Threshold monitors Alarm Severity on Maximum Rate MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 160 Table 40 Web Monitor tab Sheet 11 of 12 handler class name ms mw probe iplanet l planetOperationTrapH andler Component Monitoring MAJOR default Threshold monitors Alarm Severity on Upper Limit OverRun Component Monitoring MAJOR default Threshold monitors Alarm Severity on Lower Limit Und
24. Prerequisites Make sure the following are completed successfully e The System Management Console has been installed and started e Aserver definition has been created for the Oracle Monitor Procedures Procedure 39 Adding the Oracle Monitor Micro to the System Management Console At the System Management Console 1 Select Sites gt MgmtSite gt Servers gt MgmtSvr 2 Click on the plus sign next to the server to which you are adding the component 3 Right click on the Components folder 4 Select Add gt Component 5 A list of component loads appears in the Load List window Select the latest Small load 6 Click Apply Wait for the new component and the component configuration window to appear 7 Enter a label maximum six 6 characters in the Service Component Name field at the bottom of the configuration window The Service Component Name must be unique among all components Example Oramn1 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 142 Procedure 40 Configuring the Oracle Monitor tabs ATTENTION Do not click Apply until you have finished configuring the component At the System Management Console 1 Use the values from the table that follows to complete the Oracle Server tab parameters The shaded rows indicate values that must be addressed by the installer Table 36 Oracle Server tab
25. RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 98 12 13 Click Next to begin installation At the pop up window that says Installation successfully completed click OK Launching the System Management Console Make sure that the System Management Console application has been successfully installed on the PC Procedure 26 Launching the System Management Console At the management pc 1 2 Click Start gt Programs gt MCP gt System Management Console Enter the user name and password in the fields provided case sensitive Contact support to obtain this information IP addresses and port numbers will default to the machine logical IP address for the MgmtSvr and the MgmtSvr default port 11111 that you entered the procedure Installing the System Management Console on page 97 Click OK to log in The system manager will initialize the whole network view it will take up to a minute for the system manager screen to appear The default base directory where the System Management Console is installed on the management pc is C Program Files Nortel Networks MCP System Management Console You should have received and stored a license key that you can navigate to You can save the license key in the file C Program Files Nortel Networks MCP System Management Console lt file name gt Install the license key In MCP 3 0 the initial License Key for Core Applicati
26. access 7 If you log in as a user the following window appears NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 37 Figure 13 User login window Learn Accanrat Feit fun OF Li 4 BOT COPD i Ia amp 3 Gmo amp Ut Series Console Access D Seres Consolo Access fz Canfiquration Cansole 8 To log in as a superuser click the Admin button on the tool bar and log in with the default Superuser password system You can now configure the unit at the GUI 9 Click on the menus on the left side of the window For example selecting Ports Async opens the Async ports window MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 38 Figure 14 Example selecting Ports Async E onfiguration Console k banner defaut j ac 000000000000000000000000000 Inbound Authentication None v Transparent Mode Enabled Outbound Authentication None Break Special AuthenticationFallback Enabled Break Enabled Radius Accounting Enabled Autobaud Enabled Tacacs Accounting Enabled Autobaud Retry 5 Prompt Login AutoDial Enabled Connect Command AutoHangup C Enabled Debug Enabled ContralDTR NA v Control RTS na ug dalraa Data Loana a When you click on a port the following dialog box appears for you to enter your information Note In the TCP
27. follows to complete the Conference_Service tab parameters Table 30 Conference_Service tab Click Apply Note A progress window will display indicating the status of the deployment The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 134 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Adding and configuring the Web Client Manager Prerequisites Make sure that Procedures The System Management Console has been successfully installed and started A valid license key has been entered and accepted by the management system Procedure 37 Adding the Web Client Manager Small SharedMicro At the System Management Console 1 2 3 Select Sites gt MgmtSite gt Servers gt AppSvr Click on the plus sign next to the server to which you are adding the component Right click on the Components folder Select Add gt Component A list of component loads appears in the Load List window Select the latest Small SharedMicro load Click Apply Wait for the new component and the component configuration window to appear Enter a label maximum six 6 characters in the Service Component Name field at the bottom of the configuration window The Service Comp
28. information on the screen is correct type Y Otherwise type N and make the changes Note At this point the program runs a check sum and untars the files to the local directory Approximate time 30 45 minutes Accept the default of the local bin directory usr local bin Enter Removing Disk1 Disk2 Disk3 Disk4 Disk5 Disk6 from IMS ora_cds Y Y Enter MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 74 20 21 22 Failing to answer Y will cause the system to raise a disk space alarm on the SysMgr screen for the DBSvr You will see the message Removing Disk 1 Disk2 Disk3 Disk4 Disk5 Disk6 from IMS ora cds Oracle Install Complete At the completion of the script you will see the message Oracle Install complete Press Ctrl C to exit To check for errors at the prompt type cd space tmp Enter View the tmp oracleinstall log to see if there are any errors grep space I space error space oracleinstall log Note To check for errors look for the word error in this log file NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Deploying the initial database load Prerequisites Ensure that the MCS Base Platform Software and Oracle 9i have been installed on database servers ATTENTION Refer to your CSI datasheet to enter the IP addresses that you are prom
29. the following table to enter into the Server Properties tab parameters MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 116 The shaded rows indicate values that must be addressed by the installer Table 14 Server Properties tab Service Parameter Label Public_Service_Address lt machine logical IP address of the application server gt This value is for the Public_Service_Address default 120 120 13 25 Service Private_Service_Address not applicable default Parameter Label Value lt leave blank gt default Service CallPark TokenRange Range is 1 80 default Parameter characters Label Value This is the value to enter default if you have the ability to park a call For more information see the MCS SIP Application Module Basics NN10259 111 document 14 Use the values from the following table to enter into the Overload Controls tab parameters Table 15 Overload Controls tab Minor Alarm Threshold 96 default Major Alarm Threshold 96 default NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 117 Table 15 Overload Controls tab Continued Call queue high threshold 70 70 Call queue low threshold 40 40 Other queue high threshold 40 default Other queue low threshold 5 default Database queue high threshold 40
30. to Nortel Networks Nortel Nortel Logo and the Globemark are trademarks of Nortel Networks Sun Fire is a trademark of Sun Microsystems Inc Oracle is a trademark of Oracle Corporation Publication number NN42020 310 Product release MCS 5100 3 5 Document version Standard 1 0 Date June 2006 NORTEL
31. window see Figure 15 ensure that both the Telnet CR Filtering radio button and the Telnet Negotiations radio button are Enabled NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 39 Figure 15 Port 19 dialog box amp Tcp async Port 19 TCP Telnet Accept Verification gt Enabled Telnet Accept Msg Login Successful Telnet CR Filtering Enabled Telnet Negotiations Enabled Telnet Break TCP Transmit Buffer Size 0 TCP Window Size 1400 TCP Destination Addr ICP Destination Port OK Cancel Apply For details on using the IP Configuration Menu refer to Using the IP Configuration Menu in the LX Series Configuration Guide For information on how to boot your unit from defaults refer to Booting from Defaults in the LX Series Configuration Guide MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 40 Procedure 6 Connecting through the server to the MRV LX terminal server At the management pc 1 ATTENTION MRV Communications recommends that you change the default password for the users MRV LX terminal server before you put the unit on a network For more information refer to Changing the password defaults on page 40 Use the following procedure to access the command line interface port from a dumb terminal attached to an LX Series
32. 00 460 7835 Your Location Home Customer Support Keycode Retrieval IMS Gen KC with Auth Code Keyc de Retrieval System This section allows a Nortel Networks customer to use an auth code to generale a keycode USER STEPHEN SWAN TYPE Super User GROUP All Customer Groups Step 1 Enter the System ID for which you want to generate the keycode Select Add to add the sysld to the list and Continue when you are done Enter System Id 00 04 47 36 01 1A E s E Done If Internet Z 16 17 To generate your keycodes enter one of the MAC addresses of the server you want your Auth code applied to In this case the example shows one of the CORE MAC addresses Select Add The KRS automatically searches for and pulls up both MAC addresses associated with the CORE Click on Continue MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 90 Figure 26 Keycode Retrieval System Finding the keycode Customer Support Home Product Control Product Registration Gen KC with Auth Code Gen Temp Keycode Feature Management Administration Terms amp 5 Conditions You can contact us at North America 1 800 4 NORTEL 1 800 486 7835 Your Location Home Customer Support Keycode Retrieval IMS Gen KC with Auth Code Keyc de Retrieval System This section allows a Nortel Networks customer to use an auth code to generate a k
33. 00 466 7835 International Contacts Gen KC with Auth Code Keyc de Retrieval System In this section you can search for and retrieve keycodes USER Best Customer TYPE Super User GROUP Site ID All Customer Groups Nortel Lab 1 CORE Associated System Id 00 0A 47 36 01 1A Associated System Id 00 04 47 36 01 1B Current Version Number 1 1 Product List Current Configured Features Database server 4 units Server 2 units IPCM SubRefLimit 5 units IPCM 5units Application server 3 units Personal Agent feature 3 units Auth Codes Used Test Feature Pkg 1 05006201 E Done ep Internet A The screens show the features of your keycode and the option to download the keycode to your local PC To download the keycode click on Download Keycode From there you will see the screens to download the file and save it where you choose to on your local machine Note that the file will be provided with a product specified naming convention NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 95 Figure 31 Keycode Retrieval System Retrieving your keycode part 2 bm HORT Auth Codes Led Tow Femuro Peg di 0500201 Keycode Number 4IVOXCqGETWPXZAOl0658nd m TPIJ bXe3IIABO068T5B 380 14h73 yhOik lec dq dooce dE Es 220141903973 FREE LE 0n Tekpapeyels Tn 5 t5 OH 3Ec Ta tba Uy rparpesqu03 Tn T 1 e KVb ELS c ru exrea bb 2 979 Or KEB LCL LEE 1 TS qoB1
34. 10 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 27 ATTENTION Make sure you have Business Policy Switch 2000 BPS 2000 or Layer 2 switch vendor documentation for configuring your Layer 2 switch e one 1 additional cat 5 ethernet cable to connect the MRV LX terminal server to the layer 2 switch apc for the System Management Console and access to the network WARNING Static electricity could be harmful to the servers Setting up rack to mount hardware Procedure 1 Setting up rack to mount hardware At the rack 1 Mount all equipment Refer to the following diagram that displays the mounting for the rack Mount Layer 2 switch e Mount the MRV LX terminal server Mount Sun Fire V210s Database Management Accounting server Application server e optional equipment Mount conference server Refer to the Media Application Server documentation for more information e optional equipment Mount gateway Refer to customer specific gateway installation documentation Note All MCS equipment is 19 inch rack mountable MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 28 Figure 4 MCS 5100 19 inch rack e le le e e e e e e Y i Connecting the Sun Fire V210 server to the layer 2 switch Procedure 2 Connecting the V210 server to the layer 2 switch At the b
35. 120 13 25 Machine Primary physical interface bge0 Machine Primary physical host name microappbge0 Machine Primary physical IP address 120 120 13 23 Machine Secondary physical interface bgel Machine ondary physical host name microappbgel Machine Secondary physical IP address 120 120 13 24 IPMP ping target 1 120 120 13 22 IPMP ping target 2 120 120 13 1 X3 EEE EEE EEE FE EHO EE E JE EEDE DE IE CC JE FE FE SE DE IE JE FE SE SE XCXEEXEXCXCOXCO09 9 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 63 14 15 16 17 18 19 20 21 22 Is this IPMP group configuration acceptable Y N Select Y to accept or N to change The default route IP address should appear If correct press Enter Otherwise type it in then press Enter Note f your configuration does not include a router then enter the machine logical IP address of your server Do you intend to deploy the Web Server to this machine y n Enter Y You are now configuring the Syslog Daemon Press Enter to continue Does the Management Server have a SysMgr Service Logical IP Address Y N Select N Press Enter to configure the LOM port You will need to enter the following information P address for the Physical Ethernet Net Management port Netmask for the Physical Ethernet New Management port Gateway IP address Note If the Net Management port was previously configured the I
36. 2006 87 Server Service Guide applicable to your system see the Overview chapter for a listing of the service guides Note f you have a second Media Application Server for your system you must select Create a second time as only two MAC addresses can be associated with any one Media Application Server Figure 23 Keycode Retrieval System Adding a Media Application Server http f krs ca nortel com nortelnetworks eservice eld jsps site_reg_maint_2 jsp Formaction c You can contact us at North America 1 800 4 NORTEL 1 800 466 7835 International Contacts 14 SITE NAME NORTEL LAB 200 VERSION 1 1 CITY Richardson COUNTRY UNITED STATES STATE PROV Texas Step Add systems to the site by selecting the type and clicking the Create button Click the Continue button when you are done MEDIA SERVER x MEDIA SERVER ACTION CD CORE ACTION 00 04 47 36 01 1A 00 04 47 36 01 1B em Continue Cancel You will see a summary page of your entries If the information displayed is correct click on Save You will have completed registering your system If the information is not correct click on Cancel and begin again MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 88 Figure 24 Keycode Retrieval System Current Summary Address http Jkrs ca nortel com nortelnetworks eservicejeld jsps site r
37. 3 contact support NN42020 310 MCS 51003 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 53 Installing CD3 Approximate time estimate 90 minutes Procedure 14 Installing CD3 At the management pc 1 Place CD3 in the CD ROM drive and press Enter at the prompt ATTENTION Wait for the login prompt to appear The script will execute after you press Enter The installation will continue Please wait The system will prompt you for the next step 2 Log in as root Enter 3 Enter your lt customer specific password gt Enter Note 1 CD 3 will eject from the CD ROM when installed Note 2 You will be prompted to insert CD4 ATTENTION If you are not prompted for CD4 contact support MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 54 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 maeretele gt 9 O1 Copyright Nortel Networks Limited 2006 Installing Disk 4 ATTENTION The following sections describe installing CD4 according to the specific server type Please note that there are some small but very important differences in the installation of the two types of servers database accounting management or application server Database Accounting Management server DBSvr AcctMgr MgmtSvr Approximate time estimate 30 minutes Procedure 15 Installing CD4 At the m
38. 600 default information Number of users 2000 default Update interval for presence limits default 86400 Update interval for admin banned 900 default users Update interval for user banned 900 default users IMAuthNonce table size 5 default IMAuthNonce generation interval 60 default Number of call logs 5000 default IM CallLog DB write interval 60 default 8 Use the values from the table that follows to complete the Location Service Manager tab parameters Note This tab applies to DNS servers only Table 9 Location Service Manager tab DNS SRV Default UDP default Transport DNS SRV URL dns 0 0 0 0 If you have a DNS server default enter the IP address NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 115 9 Use the values from the table that follows to complete the Registrar Service tab parameters Table 10 Registrar Service tab Maximum Registration Duration 86400 default 10 Use the values from the table that follows to complete the Server Subscription tab parameters Table 11 Server Subscription tab 11 Use the values from the table that follows to complete the Subscription Processing tab parameters Table 12 Subscription Processing tab maximumExpires 86400 default 12 Use the values from the table that follows to complete the Long Call Service tab parameters Table 13 Long Call Service tab Duration 60 default 13 Use the values from
39. Copyright Nortel Networks Limited 2006 85 Figure 21 Keycode Retrieval System Current Summary http krs ca nortel com nortelnetworksfeservicefeld jsps site_reg_maint_2 jsp x Product Control Product Registration Gen KC with Auth Code Gen Temp Keycode Retrieve History Help Terms amp Conditions You can contact us at North America 1 800 4 NORTEL 1 800 466 7835 International Contacts This section enables you to register new products into the Keycode Retrieval System so that you can add or transfer features to the product in the future USER Best Customer TYPE Support User User GROUP All Customer Groups Current Summary SITE NAME NORTEL LAB 200 VERSION 11 Richardson UNITED STATES STATE PROV Texas CITY COUNTRY Step Add systems to the site by selecting the type and clicking the Create button Click the Continue button when you are done CD Cancel Select the server you want to enter MAC addresses for first then click on Create 10 Enter the MAC addresses of the CORE servers and click on Add MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 86 Figure 22 Keycode Retrieval System Adding MAC address Address http krs ca nortel com nortelnetworks eservice eld jsps sie reg maint 2 jsp formAction c Customer Support Keyc de Retrieval System Register
40. P address Netmask address and Gateway address are shown as the defaults for the entries in steps 19 20 and 21 below Press Enter to accept the default IP addresses Enterthe TP address for the Physical Ethernet Net Management Port Default 0 0 0 0 Enter the netmask for the Physical Ethernet Net Management Port Default 255 255 255 0 Enter the Gateway IP address Default 0 0 0 0 You are asked to confirm the LOM port configuration Type Y to accept the LOM port configuration or N if you want to change something The system will now reboot and come up requesting that you insert CD5 ATTENTION If you are not prompted for CD5 contact support MCS 2 server Sun Fir e V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 64 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing Disk 5 all servers Approximate time estimate is 30 minutes Procedure 17 Installing CD5 At the management pc 1 Place CD5 in the CD ROM drive on the server and press Enter at the prompt Note 1 CD5 will eject from the CD ROM when installed Note 2 For Management Accounting servers you will be prompted for CD6 Refer to Installing Disk 6 MgmtSvr AcctMgr only on page 69 for instructions The Application IPCM server AppSvr IPCM will reboot ATTENTION On a brand new machine only the Net MGT LOM port i
41. P software configuration data or provisioning ata You will need the six Solaris installation CDs and the six Oracle CDs to perform this procedure At each configuration step you will see a summary of the configuration and can accept that configuration or change it Once the data configuration is completed the services will be hardened again and the system rebooted Completely re install the Solaris CDs in the DBSvr and MgmtSvr AcctMgr machines as described earlier in this document Then re install the Oracle CDs as described earlier in this document Once you have completed the Oracle installation you can unconfigure MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 172 the server which takes about five minutes and then reload the IP addresses see Procedure 46 Reloading IP addresses after system installation Reloading the IP addresses on each server takes about 15 minutes Procedure 46 Reloading IP addresses after system installation At the management pc 1 Log in to the system as root through the console port connection You must have the root password to apply this procedure lusr local bin unconfig_server You will see the following message Do you really want to re configure all IP addresses and system data of this machine N Answer Y and press the Enter key to continue You willthen see a warning message This program will unconfigure your s
42. TY from www chiark greenend org uk sgtatham putty Provide the following hardware Business Policy Switch 2000 BPS 2000 or Layer 2 switch One 1 cat 5 Ethernet cable that is used to connect the MRV LX terminal server to the layer 2 switch PC for management administration Refer to Minimum and recommended requirements for customer provided PC on page 23 ATTENTION You must have access to the MCS network Make sure Acronyms There are no other maintenance or provisioning activities pending and no such activities are planned for the duration of the installation procedures and follow up soak period You have a detailed knowledge of your network s configuration You have proficiency using UNIX operating system commands You have access and privileges to the network You have authority or immediate access to people with authority to make decisions on any issues that may arise The following acronyms are referenced in this document lights out management LOM Network Time Protocol NTP customer specific information CSI NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 19 Key stroke symbols The following key stroke symbols are used in this document Press Esc 2 Press Escape then press 2 Navigate Use the arrow keys to move up or down Select Use the spacebar to select an item lt Value in brackets gt Enter value indicated in brackets Enter
43. Web site The content of this documentation was current at the time the product was released To check for updates to the latest documentation and software for MCS 5100 click one of the following links Link to Takes you directly to the Latest Software Nortel page for MCS 5100 software located at www130 nortelnetworks com cgi bin eserv cs main s p cscat SOFTW ARE amp resetFilterz1 amp tranProduct 12 482 Latest Documentation Nortel page for MCS 5100 documentation located at www 130 nortelnetworks com cgi bin eserv cs main js p cscat DOCUMENTATION amp resetFilter 1 amp tranPro duct 12482 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 8 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 merererele gt e O1 Copyright Nortel Networks Limited 2006 How to get help This section explains how to get help for Nortel products and services Getting help from the Nortel web site The best way to get technical support for Nortel products is from the Nortel Technical Support web site www nortel com support This site provides quick access to software documentation bulletins and tools to address issues with Nortel products From this site you can e download software documentation and product bulletins search the Technical Support Web site and the Nortel Knowledge Base for answers to technical issues si
44. _01 1 4 2 02 1 4 2 08 1 4 2 04 or 1 4 2 05 for the corresponding installer for JRE version 1 4 2 01 1 4 2 02 1 4 2 03 1 4 2 04 or 1 4 2 05 You may also provide a different JRE installer filename has to be j2re windows i586 p exe in the JRE installer directory which is the IMS web data web webapps pca data jar directory on the server where the Provisioning Module runs In this case use any other version string such as 1 4 2 06 This field should not contain white space 4 Use the values from the table that follows to complete the Database Base tab parameters MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 132 The shaded rows indicate values that must be addressed by the installer Table 27 Database Base tab 5 Use the values from the table that follows to complete the SIP Personal Agent tab parameters Table 28 SIP Personal Agent tab Maximum User Picture Size A l om default 6 Use the values from the table that follows to complete the Provisioning Client tab parameters The shaded rows indicate values that must be addressed by the installer Table 29 Provisioning Client tab Provisioning Server Port 8821 default Provisioning Blocked Wait 10000 default Time NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 133 7 Use the values from the table that
45. ack of the Sun Fire V210 server 1 Connect the Sun Fire V210 server Net 0 and Net 1 ports to the layer 2 switch using Ethernet cat 5 cables NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 29 Figure 5 Back view of Sun Fire V210 server Power inlet SERIAL 10101 NET MGT SERIAL MGT Ethernet Ethernet 0 Net 0 Ethernet 1 Net 1 Ethernet 2 Net 2 Net MGT LOM Ethernet 3 Net 3 Note 1 Net 0 and Net 1 are for redundancy It is preferable that each Ethernet port get cabled to a different layer 2 switch if available for maximum redundancy Note 2 The two Ethernet switches are physically linked together through either cascade modules or Ethernet links 2 Plug in the power cords at the back of the V210 server ATTENTION Do not power up the server at this time MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 30 Connecting the Sun Fire V210 server to the MRV LX terminal server The MCS 5100 platform uses the Sun Fire V210 server medium configuration Note This server is only available in an AC power configuration Procedure 3 Connecting the serial port on the V210 to the MRV LX terminal server At the back of the Sun Fire V210 server 1 Connect the Sun Fire V210 server Net MGT LOM serial port and Serial MGT port to the MRV LX terminal server Figure 7 Sun Fire V210 server n
46. al server 33 Powering on the servers 45 Installing DISKS 1103 us sus makes 9px mE ede dene Re CR no 47 Installing CD1 RTL enn heee ds tedeneies ode eek He 47 Ip cipe CRT C doek setenv de Ea tone ke E sees ad 52 Installing CD3 ELE 53 Installing DISK rs ace Oe ivan REOR 9 99x86 wate one eee eh ls 55 Database Accounting Management server DBSvr AcctMgr MgmtSvr 55 Application servers SIP Application Module IPCM Web Client Manager Provisioning Module 60 Installing Disk 5 all servers 65 Enabling or disabling the automatic mount 67 Installing Disk 6 MgmtSvr AcctMgr only 69 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 4 Installing Oracle 9 2 0 4 on the database server 71 Installing Oracle 9 2 0 4 71 Deploying the initial database load 75 Prerequisites D using bod tin Se eww dede e teste Laude 75 Deploying the MCS database load imssipdb 75 Deploying and starting the Sysmgr 77 ii cg siais aaa saie h B i a a die Ei lisser termes dirons 77 Deploying and starting the Sysmgr
47. al server The MRV LX terminal server allows the installer to access all the servers simultaneously ATTENTION For complete information on how to install configure and access the MRV LX terminal server refer to the MRV Communications Inc LX Series Software Kit CD particularly the Getting Started with the LX 4000 Series and LX 4000 Quick Start Instructions that come in the terminal server box or go to www mrv com Procedure 4 Connecting the MRV LX terminal server cable to the servers and management PC At the terminal server 1 Connect port 8 to the management PC using the console cable and db9 connector that comes with the MRV LX terminal server Note After the terminal server has been configured the connection between the management PC and the terminal server is not needed and the cable can be removed 2 Connect the MRV terminal server 10 Base T port to the layer 2 switch Refer to the Getting Started with the LX 4000 Series document in the CD that comes with your terminal server for specific information about the pinouts on your terminal server model Procedure 5 Accessing the MRV LX terminal server At the browser address field 1 Type in the IP address of your MRV LX terminal server The LX Series Configuration Console page appears as shown MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 34 Figure 9 MRV Configuration Cons
48. allation and Commissioning Guide Copyright Nortel Networks Limited 2006 168 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Appendix A Deploying the PC Client Along with the initial load Nortel Networks delivers the following Java Network Launch Protocol JNLP file pcclient jnip Zip file containing latest code resources pcclientcode zip System administrators need to perform the following steps to deploy Multimedia PC Client loads At the management pc 1 Unzip the zip fle containing the code resources pcclientcode zip onto any machine connected to the network Make sure that you preserve the paths for example the checkbox Use folder names in Winzip should be checked Identify the Provisioning Module server s on which to deploy the load Customization of the JNLP file pcclient jnlp is possible by modifying certain attributes For example if this update is considered to be a critical one the critical value can be checked If end users are not prompted for confirmation when updates are applied then the confirm value can be assigned as false Modification of title and icon for the confirmation dialog is also possible Use a secure File Transfer Protocol SFTP tool to perform the following tasks a Connect to the server b Upload the pcclient jnlp to IMS web data web webapps prov pcclient jnlp c Upload the unzipped code resource files to IMS web d
49. ample European Login or North American Login 5 In step 2 Product Family select the product you wish to generate keycodes for in this case select Multimedia Communication Portfolio 6 Next you will be asked to enter your User ID and Password The following screen then appears NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 83 Figure 19 Keycode Retrieval System Creating your site Your Location Home Customer Support Keycode Retrieval MCP Product Registration Customer Support Keyc de Retrieval System Register Product Registration Product Control Product Registration This section enables you to register new products into the Keycode Retrieval i System so that you can add or transfer features to the product in the future Gen Temp Keycode Retrieve Keycode Retrieve History USER Best customer TYPE Support User User GROUP All Customer Groups Help Terms amp Conditions Step Query available sites by entering text in any combination of the two query fields and then click the Search button Matching sites will be displayed in the result list Note that the result list will show only the first 50 You can contact us at Sites that satisfy the query so you may need to further refine your query Create a new site by clicking the Create button North America 1 800 4 NORTEL 1 800 466 7835 Site Name fo Intemational Contacts System Id Loo
50. anagement pc 1 Place CD4 in the CD ROM drive and press Enter to continue Wait until you see the following statement appear You are now configuring the NTP time source for this server The servers which run the Management and Accounting service will be the source You will need to provide the Machine Logical IP Address of each server If running simplex mode provide the same address twice 2 Press Enter to continue 3 You will see the following message The Management server requires an external clock Select External Clock for time source external to the Management server Select Internal Clock for the Managment server MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 56 to use the local system clock as the time source Note Select Time Source X External Clock Device E External Clock Source IP Address es I Internal Clock Unreliable Select option from list above E I X ATTENTION Refer to the CSI for NTP time source IP information Select one of the options then press Enter If you select X External Clock Source you will see a list of clock types Select the type you have or none 99 If you enter Internal Clock then enter the MACHINE Logical IP Address of the Management Accounting server If you select E for External time source you will be prompted as follows How many external clock sources would you l
51. ange the superuser password for the unit do the following a Access the Configuration Command Mode b Enter the password command at the Config 0 gt gt prompt c Enter a new superuser password at the Enter your NEW password prompt The password will be displayed as asterisks d Re enter the new superuser password at the Re Enter your NEW password prompt The password will be displayed as asterisks Procedure 8 Accessing the MRV LX terminal server At the management pc 1 Select Start gt Programs gt Accessories gt Communications gt HyperTerminal exe 2 Name the HyperTerminal Session termserv Enter 3 Ensure that the appropriate COM port is set and that the terminal emulation is set to VT100 Note 1 You may be asked for the following parameters e 9600 baud rate e 8 data bits second parity None e Stop bit 1 e Flow control None Note 2 Press Enter until you receive a log in prompt You may need to press Enter several times before the prompt appears 4 Log in to the HyperTerminal access Enter Note The letters do not appear when you type them You are typing them in blind 5 Enter your username admin Enter 6 To change security at the prompt type set priv Enter MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 42 10 11 12 13 14 15 Enter your password system Enter Define server ip address lt IP address of th
52. ar to mark your choice Ignore time zone syntax errors Press Esc 2 to continue At the Time zones prompt select the time zone for example Central for the Richardson Texas area where the system is going to be deployed Use the arrow keys to navigate to the required time zone and press the spacebar to mark your choice Press Esc 2 to continue Please wait for the next prompt At the Date and time prompt set up the date and time Press Esc 2 to continue Confirm information Ensure all fields are filled correctly Press Esc 2 to continue and wait for the message System identification is completed The Solaris installation program begins You will see the message Creating disk profile for system ATTENTION Make the following selection very carefully If you make a mistake at this point you will need to start over beginning with Powering on the servers on page 45 The selection of the number depends on the server type You will see the following message Ok cocco ok A A A A KKK KKK KKK KKK KKK KKK KKK KKK ko ko ko ko ko ko ko EX WA Choose server configuration 1 Application Server 2 Management Accounting 3 Oracle DB KKEKKKKKKKKEKK ckck ck kock ck ck ck kck ck ck ck ck ck ck ck ck ck ck ck kock ck k ck k ko k kkkk Select your required server type 1 2 or 3 then press Enter MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006
53. are executed on the database management accounting Sun Fire V210 server using PuTTY SSH into the machine logical IP address Example Open a PuTTY SSH session to 120 120 13 22 Procedure 43 Verifying the database server At the management pc 1 2 Log into the server as nortel lt new nortel user password After the MCS Base Platform System Software installation execute the following command to verify IP addressing mcsmicromgmt export home nortel ifconfig a 100 flags 1000849 lt UPRLOOPBACK RUNNING MULTICAST IPv4 gt mtu 8232 index 1 inet 127 0 0 1 netmask ff000000 bgeO flags 9040843 lt UP BROADCAST RUNNING MULTICAST DE PRECATED IPv4 NOFAILOVER mtu 1500 index 2 inet 120 120 13 20 netmask ffffff00 broadcast 120 120 13 255 groupname imspub bge0 1 flags 1000843 lt UP BROADCAST RUNNING MULTICAST IPv 4 mtu 1500 index 2 inet 120 120 13 22 netmask ffffffOO broadcast 120 120 13 255 bge1 flags 69040843 lt UP BROADCAST RUNNING MULTICAST D EPRECATED IPv4 NOFAILOVER STANDBY INACTIVE mtu 1500 index 3 inet 120 120 13 21 netmask ffffffOO broadcast 120 120 13 255 groupname imspub Look for the entry that starts with bgeO The parameters that follow show the IP address subnet mask and whether the MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 164 interface is UP This example output shows that bgeO is assigned to IP addre
54. ata web webapps prov pcclientclode It is possible to perform steps 1 4 directly on the Provisioning servers without FTP MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 170 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Appendix B Reloading IP addresses after system installation This process prompts you for the hostname country time zone and IP address to enable movement of the system after the system is installed You can re enter the same data that was already in those parameters if they have not changed You can change the system identification parameters and all IP addresses binding to a single interface without having to reload the OS from a CD This procedure is for pre staging a system It cannot be used on a running operational system The following procedure Procedure 46 Reloading IP addresses after system installation brings the system to the boot prompt When the system reboots it invokes the Solaris system identification process and then invokes the MCP commissioning script at root login This is the same configuration procedure executed during CD installation and commissioning and is common for all MCP supported Solaris platforms This procedure called re ip in this chapter requires two system reboots to complete the configuration e is valid for Solaris servers only o not modify MC
55. ble that follows to complete the Media Portal tab parameters The shaded rows indicate values that must be addressed by the installer Table 4 Media Portal tab MGCP Port 3903 Po default InsertPortalWhenAnyBFW These two are mutually LocationBasedinsertionRules exclusive 4 Use the values from the table that follows to complete the Prov Sync Service tab parameters Table 5 Prov Sync Service tab Sync Time Period 10 default 5 Use the values from the following table to enter into the Database Base tab parameters NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 113 The shaded rows indicate values that must be addressed by the installer Table 6 Database Base tab 6 Use the values from the table that follows to complete the SIP TCF Base tab parameters Table 7 SIP TCF Base tab Invite Timer 128000 default Maximum Number of 5 default Redirections Initial Maximum Hop Value 20 default 7 Use the values from the following table to complete the In Memory Database tab parameters MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 114 The shaded rows indicate values that must be addressed by the installer Table 8 In Memory Database tab Number of domains 500 default Update interval for domain
56. cation tab parameters Table 2 Authentication tab Sheet 1 of 2 Private Key MCP default NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 111 Table 2 Authentication tab Sheet 2 of 2 Nonce Interval 600 default Authorized Method Entries Authorized register initial registration Method authorization invite calls authenticated subscribe Presence authenticated message Instant Message authenticated 2 Use the following values to complete the Local Accounting Manager tab The shaded rows indicate values that must be addressed by the installer Table 3 Local Accounting Manager tab Sheet 1 of 2 Primary CAM IP Address lt service logical IP address of accounting server gt 120 120 13 22 Primary CAM Port 17667 default Recovery CAM IP lt service logical IP 120 120 13 22 Threshold Address address of accounting server gt Recovery CAM Port 17667 default File Rotation Size 100000 default File Rotation Time 300 default Disk Monitor Major 50 default MCS 2 server Sun Fire V210 ROHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 112 Table 3 Local Accounting Manager tab Sheet 2 of 2 Disk Monitor Critical 75 default Threshold Enable Billing For Instant unchecked default Message 3 Use the values from the ta
57. cribed in the following section Deploying and starting the Sysmgr Procedure 22 Deploying and starting the Sysmgr At the management pc 1 Log into the management accounting server User name nortel Password lt Enter your new password gt 2 At the prompt type mgmtdeploy pl MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 78 3 ATTENTION When selecting the management server load always select the load that contains the word micro in it If the non micro load is selected the installer will receive an Out Of Memory error The server load names are e mgmtsvr_all mico ims for a 2 server V210 installation e mgmtsvr_all small ims for a 4 server V210 installation e mgmtsvr_all ims for an 8 server V210 installation Please enter the correct number of the load to deploy Example micromgmt export home nortel gt mgmtdeploy pl Obtaining input required to deploy and configure the mgmtsvr bundle Please enter all IP addresses in dot notation format Querying DSM for available loads Select a mgmtsvr load from the following list 1 mgmtsvr_all micro_ims_3 0_buildxxxx 2 mgmtsvr all small ims 3 0 buildxxxx 3 mgmtsvr all ims 3 0 buildxxxx Please enter the number 1 of the load to deploy 1 4 Is the database replicated N Enter 5 Enter Machine Logical IP Address Primary DB lt machine logica
58. d a testi tt File name ficensekeytest Open Files of type m Files Cancel Cancel 7 Once you have entered the new License Key you will see a dialog box notifying you whether the update is successful or fails If the system does not find a license key in the database or on the Managements server local disk a dialog box Figure 33 will appear prompting for a license key file If you do not immediately see your license key locate it by browsing the file system 8 Select the license key file by highlighting the file and pressing Apply Once the file is selected the license key appears in the text area If a wrong file is selected the Open File button can be used to select a different file Once you have selected the Apply button a request is sent to the System Manager and the license key is saved into the database Upon successful entry into the database the Sysmgr sends back an appropriate response to the System Management Console and you will be notified that the license key has been saved 9 By default the only components available at this point are the Sysmgr that is the Mgmtsvr and a database instance Expand each element in the tree to verify that the MgmtSvr component is loaded and running NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 101 The console screen has the basic look and feel of a Windows Explorer window with a tree str
59. d Component 0 default Monitoring Threshold monitors Lower limit Gauged Component 10 default Monitoring Threshold monitors Negative going threshold value Gauged Component 5 default Monitoring Threshold monitors Negative going threshold hysteresis MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 144 Table 37 IMS Main Database tab Sheet 2 of 4 Gauged Component 70 default Monitoring Threshold monitors Positive going threshold value 1 Gauged Component 5 default Monitoring Threshold monitors Positive going threshold hysteresis 1 Gauged Component 85 default Monitoring Threshold monitors Positive going threshold value 2 Gauged Component 5 default Monitoring Threshold monitors Positive going threshold hysteresis 2 Gauged Component 99 default Monitoring Threshold monitors Capacity or max value Gauged Component 0 default Monitoring Threshold monitors Capacity or max hysteresis Gauged Component NONE default Monitoring Threshold monitors Alarm Severity on Negative Going Threshold Gauged Component WARNING default Monitoring Threshold monitors Alarm Severity on Positive Going Threshold1 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 145 Table 37 IMS Main Database tab Sheet 3 of 4 Gauged Component Monitoring Threshold mo
60. dding and configuring the SIP Application Module Prerequisites Make sure that Procedures The System Management Console has been successfully installed and started A valid license key has been entered and accepted by the management system Procedure 30 Adding the SIP Application Module component At the System Management Console 1 Select Sites gt MgmtSite gt Servers gt Add gt General gt AppSvr See Adding a server on page 103 for information on how to add a server before adding the SIP Application Module Click on the plus sign next to the server to which you are adding the component Right click on the Components folder Select Add gt Component A list of component loads appears in the Load List window Select the latest Small load Click Apply Wait for the new component and the component configuration window to appear Enter a label maximum six 6 characters in the Service Component Name field at the bottom of the configuration window The Service Component Name must be unique among all components Example AppSv1 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 110 Procedure 31 Configuring the SIP Application Module tabs ATTENTION Do not click Apply until you have FINISHED configuring all the tabs At the System Management Console 1 Use the values from the following table to enter into the Authenti
61. dress of the server you are working on IP Multipathing needs a set of reliable hosts to ping against Select a set of three IP addresses in this subnet that belong to reliable nodes such as fault tolerant servers Select the three nodes from the following list in order of preference For IPMP GROUPS e Machine Logical IP address of the database server e Machine Logical IP address of the Management server MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 62 e Machine Logical IP address of the CAM server e BPS stack IP address Other optional devices PRI Gateway host Provide between two and six ping targets or each IPMP group for proper IPMP failover reliability Enter the address 0 0 0 0 to indicate list is complete if entering less than six targets Note Do NOT use this server s own IP address as a ping target 12 Press Enter after each IP address for example 0 0 0 0 Enter This is the third ping target machine logical IP address Example Enter ping target 1 120 120 13 22 Enter Enter ping target 2 120 120 13 1 Enter Enter ping target 3 0 0 0 0 Enter Note 0 0 0 0 ends the ping target list 13 You will see the configuration summary appear as shown in the following figure Figure 17 Application server IPMP configuration summary IP Multipath group nane imspub Machine Logical host nane nicroapp Machine Logical IP address 120
62. e MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 50 Netmask Netmask 9 ATTENTION Do not accept the default unless you are sure it is correct for your subnet Enter the subnet mask for example 255 255 255 0 Press Esc 2 to continue IPv6 Enables IPv6 10 ATTENTION IPv6 is not supported Accept the default No Press Esc 2 to continue There is a slight delay between screens Please wait Confirm information 11 Ensure all fields are filled correctly Press Esc 2 to continue Press Esc 4 if you need to change anything Configure Security Policy 12 Confirm the Kerberos information by accepting the default No Press Esc 2 to continue Confirm information 13 Ensure all fields are filled correctly Press Esc 2 to continue Name Service Name Service 14 Confirm the name service information by using the down arrow key to navigate to None Press the Return key Press Esc 2 to continue NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 51 Continuing the process 15 16 17 18 19 20 Confirm your information Ensure all fields are filled correctly Press Esc 2 to continue Press Esc 4 if you need to change anything At the Regions prompt select the country where the system is going to be deployed Use the arrow keys to navigate to the required country and press the spaceb
63. e 16 Database Management Accounting server IPMP configuration summary FETE HE HE FE HE FE FE FE 3 FE FE 3 HE FE HE HE FE FE HE FE HEE HE FE FE 3 FE FE FE HEHEHE FE JE JE 3 HEHEHE 3 3 3 3 3 3 38 3 3 3 3 FE IP Multipath group name ims ha Machine Lo gi amp IPMP pin vea bel T IPMP ping ta get 2 120 120 13 HHH HH HH HH HH JE FE HH HH FE FE FE FE FE FE FE JE FE FE FE JE FE FE JE FE FE FE FE FE FE FE FE FE FE JE FE FE FE FE 3 JE 3 3 36 3 3 Is this IPMP group configuration acceptable Y N Select Y and press Enter 15 The default route IP address should appear If correct press Enter Otherwise type it in then press Enter Example 120 120 13 1 Note f your configuration does not include a router then enter the machine logical IP address of your server 16 You are now configuring Management Server or Accounting Server Service Failover Please have the Management Server System Manager and Accounting Server Accounting Manager Service Logical IP addresses and the Machine Logical IP addresses ready Press Enter to continue NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 59 17 18 19 20 21 22 23 You will see the following message Obtaining IP Addresses for SysMgr AcctMgr Failover Operation Note f you don t have plan to configure the failover service type in the same primary service logical IP add
64. e addressed by the installer Table 20 SIP TCF Base tab Invite Timer 128000 default Maximum Number 5 default of Redirections Initial Maximum Hop 20 default Value 5 Use the values from the table that follows to complete the Conference Service tab parameters The shaded rows indicate values that must be addressed by the installer Table 21 Conference Service tab NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 125 6 Use the values from the following table to enter into the In Memory Database tab parameters The shaded rows indicate values that must be addressed by the installer Table 22 In Memory Database tab Number of domains 64 default Update interval for domain 600 default information Number of users 100000 default Update interval for presence limits default 1800 Update interval for admin banned 900 default users Update interval for user banned 900 default users IMAuthNonce table size 5 default IIMAuthNonce generation interval 60 default 7 Use the values from the table that follows to complete the Prov Sync Service tab parameters The shaded rows indicate values that must be addressed by the installer Table 23 Prov Sync Service tab Click Apply The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree
65. e iPlanet Monitor At the System Management Console 1 2 3 Select Sites gt MgmtSite gt Servers gt AppSvr Click on the plus sign next to the server to which you are adding the component Right click on the Components folder Select Add gt Component A list of component loads appears in the Load List window Select the latest Small load Click Apply Wait for the new component and the component configuration window to appear Enter a label maximum six 6 characters in the Service Component Name field at the bottom of the configuration window The Service Component Name must be unique among all components Example iPIMon MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 150 Procedure 42 Configuring the iPlanet Monitor At the System Management Console 1 ATTENTION Do not click Apply until you have finished configuring the tab Use the values from the table that follows to complete the Web Monitor tab parameters Note The shaded rows indicate values that must be addressed by the installer Table 40 Web Monitor tab Sheet 1 of 12 SNMP request port 8161 default SNMP agent IP address machine logical IP of 120 120 13 25 Provisioning Module gt Active checked default Component Monitoring com nortelnetworks i default Class name ms mw probe iplanet planetProcessHandler Component Mon
66. e terminal server gt Enter Define server ip subnet mask lt ip address of the subnet mask gt Enter Define server ip primary gateway address lt ip address of the primary gateway gt Enter Define port lt select port from range 1 18 gt telnet newline filtering cr Enter Note Type a range 1 18 for every port the Sun Fire V210 server is connected to Define port for use with SMDI Define port 19 telnet newline filtering none Note You can verify the ports with the command show ports 1 19 telnet chara Enter Save your changes Log out Note Using the command define saves the configuration To kill a session on a port type logout port 12 Enter Procedure 9 Connecting a server to the MRV LX terminal server ATTENTION The procedures in this document assume that you are using PuTTY It is suggested that you download from the web PuTTY VT 100 Emulator a freeware configurator tool to set up sessions Download PuTTY from www chiark greenend org uk sgtatham putty At the management pc 1 2 Connect a cat 5 Ethernet cable from the management PC to the layer 2 switch Launch PuTTY Note Refer to the customer specific information datasheet to enter the MRV LX terminal server IP address and the port number In the hostname field enter lt IP address of the MRV LX terminal server NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 43 4 For p
67. ed default NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 123 Table 17 IP Client Manager tab Sheet 2 of 2 Phase 1 Firmware ID B60 default Phase 2 Firmware ID D61 default Use UFTP checked Box is checked default UFTP Server Port 50020 default Keep Alive Timer 40 default KA Phone Timer 90 default Switch Server Delay 5000 default Min ReReg Delay 60000 default Max Reg Attempts 25 default Server Recovery 1 default Time Min Server Recovery 5 default Time Max 2 Use the values from the table that follows to complete the Database Base tab parameters The shaded rows indicate values that must be addressed by the installer Table 18 Database Base tab Primary Host lt machine logical IP address of 120 120 13 22 the primary database server gt Connections 5 default Secondary Host blank Leave blank default 3 Use the values from the table that follows to complete the UNIStim Base tab parameters MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 124 The shaded rows indicate values that must be addressed by the installer Table 19 UNISTIM Base tab Port 5000 default 4 Use the values from the table that follows to complete the SIP TCF Base tab parameters The shaded rows indicate values that must b
68. edia Application Server Meet Me Audio Conferencing Service Guide NN10303 111 Media Application Server Music on Hold Service Guide NN10378 113 Media Application Server Announcements Service Guide NN10379 113 Media Application Server IM Chat Service Guide NN10380 113 Media Application Server Meet Me Audio Conferencing Quick Reference NN10283 001 MCS 5100 IP Client Manager Basics NN10256 111 MCS 5100 Web Client Manager Basics NN10278 111 MCS 5100 Interworking Guide NN10372 111 MCS Backup and Recovery Guide NN42020 502 MCS Accounting Common Call Scenarios Reference Guide NN10374 800 Provisioning Enhanced 911 User Guide NN42020 132 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 15 e MCS 5100 Fault Management Alarm and Log reference NN10385 900 e MCS 5100 Performance Management OM reference NN10386 700 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 16 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Before you start the installation ATTENTION Make sure you install the latest software loads Check with your support team for the correct latest load Prerequisites Have available your completed Customer Specific Information CSI datasheet Refer to the MCS 5100 Network Deployment and Engineering Guide NN10313 191 that accom
69. efault based on your system File Rotation Time 20000 default File Compression checked default Disk Monitor Major 50 default Threshold Disk Monitor 75 default Critical Threshold NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 107 Table 1 Central Accounting Manager tab Sheet 2 of 2 TCP IP Enabled unchecked If IM Accounting is default enabled this box must be checked in order to still maintain 7 days worth of accounting records IM Accounting will impact performance of the SIP Application Modules and Accounting Module TCP IP Address 0 0 0 0 default TCP IP Primary 9000 default Host Port TCP IP Recovery 9001 default Host Port FTP Push Enabled unchecked default Primary FTP blank default Directory Recovery FTP blank default Directory Remote FTP Node 0 0 0 0 default ID FTP User ID blank Configurable default based on your system FTP USER blank Configurable default Password based on your system 2 Click Apply MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 108 The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 A
70. eg summary jsp Customer Support Keyc de Retrieval System Register Product Control Product Registration This section enables you to register new products into the Keycode Retrieval Gen KC with Auth Code System so that you can add or transfer features to the product in the future Gen Temp Keycode Retrieve Keycode Retrieve History USER Best Customers TYPE Support User User GROUP All Customer Groups Help Terms Conditions Current Summary SITE NAME NORTEL LAB 200 You can contact us at VERSION 1 1 EH Richardson North America 4 800 4NORTEL COUNTRY UNITED STATES 1 800 466 7835 STATE PROV Texas International Contacts Step Review the following configuration Click Save to confirm and save the configuration MEDIA SERVER 00 54 48 33 01 1B 00 54 48 33 01 1C CORE 00 04 47 36 01 14 D0 0A 47 35 01 1B 15 To generate keycodes for this site click on Gen KC with Auth Code from the side bar as shown in the following figure NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 89 Figure 25 Keycode Retrieval System Gen KC with Auth Code Customer Support Home Customer Support Survey Product Control Product Registration Gen KC with Auth Code Gen Temp Keyoode Feature Management Administration Terms amp s Conditions You can contact us at North America 1 800 4 NORTEL 1 8
71. ept default Example 120 120 13 22 Enter the Machine Logical IP address Management Server Enter the machine logical IP address of the MgmtSvr gt or press Enter to accept default Example 120 120 13 22 Enter the Service Logical IP address of the SysMgr Enter the lt service logical IP address of the SysMgr gt or press Enter to accept default Example 120 120 13 22 Note Information obtained for database deployment appears on the screen Is the above data correct Y Press Y to select the default or N to change Note The imssipdb deployment begins The installer will notice the PuTTY window scrolling installation information This is the Management Accounting server sending the imssipdb data to the database server Make sure that you receive the Successful Install box at the end of the script execution NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Haletolele gt le O1 Copyright Nortel Networks Limited 2006 Deploying and starting the Sysmgr Prerequisites The dbdeploy pl script is successfully deployed on the database ATTENTION Refer to the customer specific information for hostname IP addresses subnet masks and so on Deploy the Sysmgr for a non redundant configuration The operator logs into the machine logical IP address of the management server At the UNIX prompt the operator the uses the script mgmtdeploy pl to deploy and start the Sysmgr This process is des
72. equired to carry out this procedure From the main page under Support click on Keycode Retrieval This will take you to the secure login page MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 82 Figure 18 KRS login screen Customer Support Home Keycode Retrieval North America You may need to be registered in order to obtain keycodes for some 1 800 4 NORTEL products After the Online Registration is complete it will take 1 900 490 7836 approximately 5 business days to validate your registration information and provide access to restricted keycodes You can call us Europe Middle East amp Africa 00800 8008 9009 ne re Legacy KRS Decommissioning Notice for Business Communications Additional Manager BCM and Call Pilot KRS users International Numbers Please start using the New and Improved KRS The current KRS interface is no longer available Try the NEW and IMPROVED BCM Try the NEW and IMPROVED CallPilot Step 1 Choose the login location you would like to use for access to the Keycode Retrieval System Location If you are a Nortel Networks employee you can access selected product keycodes using guest as both the userid and password Step 2 Choose the product family whose keycodes you would like to access Product Family co E gt 4 In step 1 Location select a login server that matches your region for ex
73. erRun Component Monitoring unchecked default Threshold monitors Usage state affected Component Monitoring com nortelnetworks i default Class name ms mw probe iplanet planetWebServerStat sHandler Component Monitoring Web Server Stats default Component name Component Monitoring 1 default Polling interval in minutes Component Monitoring checked default Active for polling Component Monitoring com nortelnetworks i default Class name ms mw probe iplanet planetListenSocketHa ndler Component Monitoring Listen Socket Stats default Component name Component Monitoring 1 default Polling interval in minutes Component Monitoring checked default Active for polling Trap handlers Trap com nortelnetworks i default NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 161 Table 40 Web Monitor tab Sheet 12 of 12 Trap handlers Trap iPlanet Operation Trap default handler name Trap handlers Active checked default 2 Click Apply Wait for the component to appear in server list The iPlanet Monitor is installed on the same server as the Provisioning Module MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 162 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Verification procedures Verifying Server1 DBSvr MgmtSvr AcctMgr The following commands
74. ess in addition to the hostname and the loghost tag The second 120 address should reflect the bgeO interface followed by the hostname concatenated with bgeO The third 120 address should reflect the bge1 interface followed by the hostname concatenated with bge1 7 Verify the defaultroutefile micromgmt export home nortel gt cat etc defaultrouter NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 165 120 120 13 1 The only address in this file defines your default gateway route your router If this file is empty and the machine is rebooted then you will not have network access to your other servers Verifying Server2 application server The following commands are executed on the application server using PuTTY SSH into the machine logical IP address Example Open a PuTTY SSH session to 120 120 13 25 Procedure 44 Verifying the application servers At the management pc 1 2 Log into the server as nortel lt new nortel user password gt After installing the MCS Base Platform System Software CDs 1 6 execute the following command to verify IP addressing mcsmicroapp export home nortel gt ifconfig a 100 flags 1000849 lt UP LOOPBACK RUNNING MULTICAST IPv4 gt mtu 8232 index 1 inet 127 0 0 1 netmask ff000000 bgeO flags 9040843 lt UP BBROADCAST RUNNING MULTICAST DE PRECATED IPv4 NOFAILOVER gt mtu 1500 index 2 inet 120 120 13 23 netmask ffffff00 broadca
75. etwork callouts Ethernet 0 Net 0 Ethernet 1 Net 1 i Ethernet 2 Net 2 Net MGT LOM Serial MGT Ethernet 3 Net 3 ATTENTION If the network is down or the server needs to be configured or restarted use the console Net MGT port By default from manufacturing the Net MGT serial port is the only active serial port Note 1 The cables with part numbers A0500465 or NTVWO 1IM are serial cables Note 2 The P1 end goes to the V210 server and the P2 end goes to the MRV LX terminal server NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 31 Figure 8 P1 and P2 custom cable connections to terminal server 10 Base T See note MRY LX Terminal Server Ediernet Pert serial cable P2 P2 Serial Port NTVANOTIM NTVAWDTIM ethernet serial cable serial cable cable PC d Net MGT LOM pq p1 Serial MaT o RE SETTLES Net 0 Net 1 eee w Ethernet ethernet ethernet Port cable cable Port 1 24 Port 1 24 En an Port 1 24 anaes Port 1 24 ethernet cable Note This cable is only connected to configure the terminal server Following configuration remove the cable MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 32 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing and accessing the MRV LX 4000 series termin
76. eycode USER STEPHEN SWAN All Customer Groups TYPE Super User GROUP Step 1 Enter the System ID for which you want to generate the keycode Select Add to add the sysld to the list and Continue when you are done System Id 00 0A 47 36 01 14 System Id 00 0 47 36 01 1B Enter System ld 18 ep Internet Select the proper Software Version for your system Then click on Continue NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 91 Figure 27 Keycode Retrieval System Adding a MAC address Customer Support Register Product Control Product Registration Gen KC with Auth Code Gen Temp Keyoode Retrieve Keycode Retrieve History Help Terms amp Conditions You can contact us at North America 1 800 4 NORTEL 1 800 466 7835 International Contacts 19 Your Location Home Customer Support Keycode Retrieval MCP 77 Gen KC with Auth Code Keyc de Retrieval System This section allows a Nortel Networks customer to use an auth code to generate a keycode USER Best Customer TYPE Support User User GROUP All Customer Groups Step 1 System ID 00 04 47 36 01 14 00 04 47 36 01 1B Distributor End User Software Version Step 1B Select the Software Version that is currently installed on the system Click continue to move to the next step or cancel to discard your changes and start over Software Versio
77. fault coordinates of the location of this server MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 104 Longitude Optional field Describes the longitudinal default coordinates of the location of this server Platform type Drop down menu with following choices Sun Sun or Linux Select Sun IP address The machine logical IP address of the 120 120 13 25 server Snmp Port Leave the default value as is default Request Polling 240 default interval Terminal Drop down menu with the following choices MicroAnnexTerminal Server Type MicroAnnexTerminalServer Server ITouchTerminalServer Ethernetinterface Terminal The IP address of the terminal server 120 120 13 3 Server IP address Terminal Change to the standard terminal server port 2500 Server Port number connecting to the A LOM port of the server 5 Click Apply NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Adding and configuring the Accounting Module Prerequisites Make sure that e The System Management Console has been successfully installed and started e A valid license key has been entered and accepted by the management system Note Retain the default configuration settings for the GwReliability Service and Gateway Register Service tabs The Colorful Ringback Service is not supported on MCS 5100 Procedures Procedure 28
78. g prompts for each CD entered Copying files from CDROM to IMS ora cds Disk 1 6 Performing check sum on IMS ora cds Disk 1 6 12 ATTENTION Contact support if you do not receive the following response Check sum Oracle Disk 1 6 passed for each Oracle CD inserted into the CDROM ATTENTION In step 12 you will enter the hostname twice The sec db hostname is the same as the pri db hostname for a 2 or 4 server non redundant configuration NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 73 Refer to this table when entering the following command pri db hostname There is only one Hostname of the hostname for a database server for 2 server configuration example micromgmtDBSvr sec db hostname Since there is no Re enter hostname of 13 14 15 16 17 18 19 secondary server the database server enter again the pri db hostname Hostname of the database server cd space IMS ora cds Disk1 Enter JOracle Install PRIMARY primarydb hostname space lt secondarydb hostname gt space space tee space tmp oracleinstall log Enter the password oracle atthe Oracle prompt Enter Retype the password oracle Enter Select the database configuration 1 Enterprise 2 Carrier Accept the default 1 Enter Is the database replicated N Accept the default N Enter You will then see a confirmation screen If the
79. gnup for automatic notification of new software and documentation for Nortel equipment open and manage technical support cases Getting help over the phone from a Nortel Solutions Center If you do not find the information you require on the Nortel Technical Support web site and you have a Nortel support contract you can also get help over the phone from a Nortel Solutions Center In North America call 1 800 4NORTEL 1 800 466 7835 Outside North America go to the following web site to obtain the phone number for your region www nortel com callus MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 10 Getting help from a specialist by using an Express Routing Code To access some Nortel Technical Solutions Centers you can use an Express Routing Code ERC to quickly route your call to a specialist in your Nortel product or service To locate the ERC for your product or service go to www nortel com erc Getting help through a Nortel distributor or reseller If you purchased a service contract for your Nortel product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 marererele gt e O1 Copyright Nortel Networks Limited 2006 Overview The MCS 2 server Sun Fire V210 Solaris system is a small scale version of the Multimedia Communica
80. he boot gt ok prompt If the system does not have Solaris installed it will power up to the gt ok prompt You may have to send a break to get the gt ok prompt The servers will more than likely boot up to a Solaris System Identification screen Do not answer those questions Send a break to get to the gt ok prompt so you can then boot from the CD ROM Procedure 11 Power on to get the gt ok prompt At the management pc 1 If you are using PuTTY click the program icon in the upper left PuTTY title bar to access PuTTY s pull down menu 2 Mouse over the telnet command menu item to access additional drop down menu options 3 Select Break to send the break command from the PuTTY session MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 46 4 The gt ok prompt appears ATTENTION If you do not use PuTTY use the appropriate key sequence to send a break to the server to get an gt ok prompt NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Installing Disks 1 to 3 ATTENTION Refer to the customer specific information datasheet for host name IP addresses subnet masks and so on ATTENTION For installation on a brand new machine connect through the terminal server to the Net MGT LOM port until after you have installed CD5 Then log out Log back in through the terminal server to Ser
81. ht Nortel Networks Limited 2006 Configuring the Provisioning Module Prerequisites Make sure the System Management Console has been installed and started Procedures Procedure 35 Adding the Provisioning Module Small SharedMicro At the System Management Console 1 2 3 Select Sites gt MgmtSite gt Servers gt AppSvr Click on the plus sign next to the server to which you are adding the component Right click on the Components folder Select Add gt Component A list of component loads appears in the Load List window Select the latest load for the Provisioning Module Small SharedMicro Click Apply Wait for the new component and the component configuration window to appear Enter a label maximum six 6 characters in the Service Component Name field in the dialog box that appears Example Prov Note The Provisioning Module will appear under the IPCMProvWCM components folder Do not click Apply until you have finished configuring the component ATTENTION MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 130 Procedure 36 Configuring the Provisioning Module tabs At the System Management Console 1 Use the values from the table that follows to complete the SIP TCF Base tab parameters The shaded rows indicate values that must be addressed by the installer Table 24 SIP TCF Base tab
82. ial MGT port for the rest of the installation For installations on machines that have already had a system installed just remain on the Serial MGT port ATTENTION The first time you connect to a server it generates a PUTTY Security Alert Select Yes from the dialog box that appears You will then be asked to log in Use your nortel account and enter the password you have set The passwords are time sensitive and will expire after the set number of days Installing CD1 Approximate time estimate 45 minutes Procedure 12 Installing CD1 At the management pc 1 Place CD1 in the CD ROM drive MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 48 2 ATTENTION Make sure you put spaces before and after the hyphen boot space cdrom space space install 3 At the gt ok prompt boot the system boot cdrom install Enter For instructions on how to get to the gt ok prompt see Powering on the servers on page 45 Note 3 You must wait several minutes before information begins to appear Select a Language 4 To select zero 0 for English 0 Enter Select a locale 5 To select zero 0 for English 0 Enter What type of terminal are you using 6 Select three 3 for DEC VT100 3 Enter Note The following message is displayed The system is coming up Please wait ATTENTION Ignore any time zone and synta
83. ient Manager Server UDP 120 120 13 25 5080 optional TCP 1 20 120 13 25 5080 0 ptional UDP 120 12 0 13 25 5085 optiona lname sipLscCondu it TCP 120 120 13 2 5 5085 optional nam e sipLscConduit Number default of Redirections Initial Maximum default Hop Value Use the values from the table that follows to complete the Web Client Manager tab parameters The shaded rows indicate values that must be addressed by the installer Table 33 Web Client Manager tab Sheet 1 of 2 WCM Socket Server Active checked checked WCM Socket Server Host lt machine logical IP address of the Web Client Manager gt 120 120 12 43 WCM Socket Server Port 3090 default MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 138 Table 33 Web Client Manager tab Sheet 2 of 2 Audio RTP Port Low 50000 default Audio RTP Port High 50100 default Use SSL checked default Keep Alive Ping checked default Ping Time Out Timer 60 default Ping Interval Timer 120 default Connection Time Out Timer Be default Download JRE Version This field holds the version of the Java Runtime Environment JRE installer that the Web Client applet downloads For the latest version of the installer from Sun leave this field empty For the installer provided by the MCS The MCS currently provides 5 different JRE installers
84. ike to reference 1 Enter 1 You will then see the following message External Clock Source IP Address 1 Enter your clock source IP address for example 120 120 12 220 5 You will see the following message Enter the MACHINE logical IP address of the other Accounting Server Enter the primary machine logical IP address of the other accounting server Enter Example 120 120 13 22 6 You will see the following message You have chosen to configure NTP as follows Type of server Management Using external Time Source s 120 120 12 22 NTP SOURCE Accounting IP address ex 120 120 13 22 gt Is the above configuration correct y n Select Y to continue or N to change NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 57 11 12 13 Press Enter to continue You will see the following statement You are now configuring IPMP Multipathing Please have the Database Server Physical IP addresses and the Machine Logical IP address ready Have 6 IP addresses that can be used as ping buddies Recommendations for ping buddies are provided Press the Enter key to continue When you see the IP multipathing configuration for Sun Solaris information appear press Enter to accept it or type ina preferred setting The default failover timeout is set to 1000mSec Enter the primary machine physical IP address for the bgeO interface Physical IP address of the bge0 inte
85. imited 2006 60 24 25 26 27 Enterthe lt IP address for the Physical Ethernet Net Management Port gt Default 0 0 0 0 Enter the lt netmask for the Physical Ethernet Net Management Port Default 255 255 255 0 Enter the Gateway IP address Default 0 0 0 0 You are asked to confirm the LOM port configuration Type Y to accept the LOM port configuration or N if you want to change something The system will now reboot and come up requesting that you insert CD5 CD4 will eject from the CD ROM drive when installed ATTENTION If you are not prompted for CD5 contact support Application servers SIP Application Module IPCM Web Client Manager Provisioning Module Approximate time estimate 15 minutes Procedure 16 Installing CD4 At the management pc 1 Place CD4 in the CD ROM drive and press Enter to continue WAIT until you see the following statement appear You are now configuring the NTP time source for this server The servers which run the Management and Accounting service will be the source You will need to provide the Machine Logical IP Address of each server If running simplex mode provide the same address twice Press Enter to continue You will see the following message NTP Source 1 Enter the MACHINE Logical IP Address of the Management Server Enter the IP address for example 120 120 13 22 You will see the following message NTP Source 2 Enter the MACHINE L
86. irm Note This procedure skips some of the steps for initial installation of CD1 e Regions e Time Zone Date amp Time e Confirm e Password You willthensee System identification is completed The system reboots You can log back in as root 8 At the MgmtSvr you will see the following message You are now configuring the NTP time source for this server The servers which run the Management and Accounting service will be the source You will need to provide the Machine Logical IP Address of each server If running simplex mode provide the same address twice Press the Enter Key to Continue Follow the instructions for installing Disk 4 in this document MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 174 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Multimedia Communication Portfolio Multimedia Communication Server 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright 2006 Nortel Networks All rights reserved The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary
87. itoring Process Stats default Component name Component Monitoring 1 default Polling interval in minutes Component Monitoring checked default Active for polling Component Monitoring percentConnectionQu default Threshold monitors eueUsage Gauge name Component Monitoring 100 default Threshold monitors Upper limit NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 151 Table 40 Web Monitor tab Sheet 2 of 12 Component Monitoring 0 default Threshold monitors Lower Limit Component Monitoring 10 default Threshold monitors Negative going threshold value Component Monitoring 5 default Threshold monitors Negative going threshold hysteresis Component Monitoring 70 default Threshold monitors Positive going threshold value 1 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 1 Component Monitoring 85 default Threshold monitors Positive going threshold value 2 Component Monitoring 5 default Threshold monitors Positive going threshold hysteresis 2 Component Monitoring 99 default Threshold monitors Capacity or max value Component Monitoring 0 default Threshold monitors Capacity or max hysteresis MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 152 Table 40 Web Monitor tab Sheet 3 of 12
88. l IP address of the database server gt Example 120 120 13 22 6 Enter the Machine Logical IP Address Mgmtsvr lt machine logical IP address of the management server gt Example 120 120 13 22 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 79 7 Will a Motorola SAM16 server SIP PriGwy or SIP Audio Svr be deployed Y N Always answer N Enter even if you have a third party gateway Note Information obtained for deploying the Sysmgr appears 8 Is the above data correct Y Answer Y Enter 9 Start up the SysMgr and TSS processes Y Answer Y Enter Note You must wait until the system returns to prompt since the system does a sleep message as it starts each service There may be a delay Sysmgr deployment verification After completing step 9 above the screen will display deployment information Notice that the script waits 30 seconds between process executions The script is starting three processes that must be running in order to continue MCS load deployment The three processes can be verified by opening a PuTTY SSH session to the management accounting server Example Open a PuTTY SSH session to 120 120 13 22 Procedure 23 Verifying the Sysmgr deployment At the management pc 1 Log into management accounting server as nortel your new password 2 Execute the following command to verify processes micromgmt export home nortel gt meinit p
89. n E cane Enter the authcode number for the feature you wish to enable into the Auth Code box Use the system Authorization codes to build your license key file MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 92 Figure 28 Keycode Retrieval System Entering the authcode Address http krs ca nortel com nortelnetworks eservice eld jsps auth gen get ac jspitx Go Links Register P Product Control Product Redisiralion This section allows a Nortel Networks customer to use an auth code to Gen KC with Auth Code generate a keycode Gen Temp Keycode Retrieve fewode USER Best Customer TYPE Support User User GROUP All Customer Groups Hain stop t System ID 00 0A 47 36 01 1A I amp Conditi 00 04 47 36 01 1B Distributor End User You can contact us at Software Version North America Software Version 1 1 4 800 4 NORTEL 1 800 486 7835 Step 2 Enter the Auth Code Select Add to validate your Auth Code and add it to the list Select continue to move to the next step Auth Code 05006201 Add Cancel International Contacts 20 Select Add to have the KRS accept the authcode 21 The KRS will validate the authcode and ensure the features represented are valid for your server type CORE or MAS If validated successfully you will be allowed to enter more authcodes until you ve entered all fo
90. ng 5 default Negative going threshold hysteresis NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 155 Table 40 Web Monitor tab Sheet 6 of 12 Class name ms mw probe iplanet l planetCpuUtilHandler Component Monitoring 70 default Positive going threshold value 1 Component Monitoring 5 default Positive going threshold hysteresis 1 Component Monitoring 85 default Positive going threshold value 2 Component Monitoring 5 default Positive going threshold hysteresis 2 Component Monitoring 99 default Capacity or max value Component Monitoring 0 default Capacity or max hysteresis Alarm Severity on NONE default Negative going threshold Alarm Severity on Positive WARNING default going threshold 1 Alarm Severity on Positive MINOR default going threshold 2 Alarm Severity on MAJOR default Maximum Rate Alarm Severity on Upper MAJOR default Limit OverRun Alarm Severity on Lower MAJOR default Limit UnderRun Usage state affected unchecked default Component Monitoring com nortelnetworks i default MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 156 Table 40 Web Monitor tab Sheet 7 of 12 Component Monitoring Cpu Util default Component name Component Monitoring default Polling interval in minutes
91. nitors Alarm Severity on Positive Going Threshold2 MINOR default Gauged Component Monitoring Threshold monitors Alarm Severity on Maximum Rate MAJOR default Gauged Component Monitoring Threshold monitors Alarm Severity on Upper Limit overrun MAJOR default Gauged Component Monitoring Threshold monitors Alarm Severity on Lower Limit underrun MAJOR default Gauged Component Monitoring Threshold monitors Usage state affected unchecked default Monitor functions Component name BlockGetRate default Monitor functions Polling interval min default Monitor functions Active checked default Monitor functions Component name OperationalStatus default Monitor functions Polling interval min default Monitor functions Active checked default Monitor functions Component name DataFile default MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 146 Table 37 IMS Main Database tab Sheet 4 of 4 Monitor functions Polling 1 default interval min Monitor functions Active checked default Monitor functions CacheHitRatio default Component name Monitor functions Polling 1 default interval min Monitor functions Active checked default Trap handlers Trap oracleDBTrapHandler defaul
92. nt instances of Transport Enabled Protocol SIP default Transport UDP default Address Public_Service_Address default Port 5060 default NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 119 Table 16 Transport Management tab Sheet 3 of 3 Parameters Service checked Check the first two Parameter Transport Enabled Transport Enabled boxes for UDP and TCP that display Uncheck all subsequent instances of Transport Enabled Protocol SIP default Transport TCP default Address Public_Service_Address default Port 5060 default Params name sipLscConduit inte Change default qfeO bgeO rface bgeO to bgeO 16 Click Apply The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 120 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Adding and configuring the IP Client Manager Prerequisites Make sure that Procedures The System Management Console has been successfully installed and started A valid license key has been entered and accepted by the management system Procedure 32 Adding the IP Client Manager Small SharedMicro component At the System Management Console
93. ogical IP Address of the Accounting Server Enter the IP address for example 120 120 13 22 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 61 5 10 11 You will see the following message You have chosen to configure NTP as follows Type of server Application NTP SOURCE Management IP address 120 120 13 22 NTP SOURCE Accounting IP address 120 120 13 22 Is the above configuration correct y n Select Y to continue or N to change Wait until you see the following message You are now configuring IPMP Multipathing Please have the Application Servers Appsvr IPCM WebSvr WebClientMgr Physical IP addresses and the Machine Logical IP address ready Have 6 IP addresses that can be used as ping buddies Recommendations for ping buddies are provided Press Enter to continue When you see the IP multipathing configuration for Sun Solaris information appear press Enter to accept it or type in a preferred setting The default failover timeout is set to 1000mSec Enter the primary machine physical IP address for the bgeO interface Physical IP address of the bgeO interface Example 120 120 13 23 Enter the secondary machine physical IP address for the bge1 interface Physical IP address of the bgel interface Example 120 120 13 24 Enter the machine logical IP addresses of the servers that are the ping targets Note Do not enter the IP ad
94. ole window ANR lac In Reach Welcome to the LX Series Configuration Console l a The consoles requres Java Eustme Environment 1 4 0 pluzn oc later i 2oumlogd 2 Make sure you have the Java Plug in installed 3 When your browser connects to the terminal server the Java Security Warning window appears Figure 10 Java Security Warning pop up window Java Sccurity Warning yj Do you want to install anc run signed applet distributed by MRY Ge Communications In Reach Product Division a Mn Publisher authenticity verified by MRY Communications In Reach Product Division A The security certificate was issued by a company that is not trusted Fig The security certificate has not expired and is still valid Caution MRVY Communications In Reach Produci Division asserts that this content is safe You should onlyinstalliviewthis content ifyou trust MRY Communications In Reach Product Division to make that assertion Grant this session Deny Grant always View Certificate NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 35 4 Click on Grant this session The Java Security Warning window closes The LX Series Configuration Console page reappears now with the green console selection visible Figure 11 LX Series Configuration Console page BEA Netscape LX Series Console Access Page Fin Edi Yew Go Communicator a 3 a A 4 E sf 3 Back For Reload Hone Sea
95. onent Name must be unique among all components Example WCM1 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 136 Procedure 38 Configuring the Web Client Manager tabs Do not click Apply until you have finished configuring the component ATTENTION At the System Management Console 1 Use the values from the table that follows to complete the User Agent Server tab parameters The shaded rows indicate values that must be addressed by the installer Table 31 User Agent Server tab Application Server 5060 default Port Click to Call 18 default Cancel Delay 2 Use the values from the table that follows to complete the SIP TCF Base tab parameters NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 137 The shaded rows indicate values that must be addressed by the installer Table 32 SIP TCF Base tab UDP lt machine logical IP of the WCM Server gt 5080 optiona I TCP lt machine logical IP of the WCM Server gt 5080 optiona UDP lt machine logical IP of the WCM Server gt 5085 optiona I name sipLscConduit TCP lt machine logical IP of the WCM Server gt 5085 optiona lname sipLscConduit Transport Config Invite Timer Timer Replace each instance of 0 0 0 0 in the UDP and TCF strings with the machine logical IP address of the Web Cl
96. ons resides on the MgmtSvr local disk The initial License Key allows the System Manager to start so that a registered License Key can be installed at the window The System Manager only permits deployment of software components after you have entered a registered License Key into the system Once the License Key has been registered in the system that Key restricts the deployment of software components To update the License Key from the System Management Console go to the Administration button and select Update from NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 99 the License Key gt Update dropdown menu You can also select the System gt License Key gt Update menu option from the System tree as shown in Figure 32 Management Console Update License Key The System item on the file tree must be highlighted Figure 32 Management Console Update License Key Jataugecysanmet aus GIG BIBAT SUSE 6 After you have selected the Update menu item an Update License key Select License key File dialog box appears as shown in Figure 33 Select License key File Window MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 100 Figure 33 Select License key File Window WS Update License key 1201201325 X fj Select License key File Lookin Syilcensekeytest e ek f IMSKeyFile fa Lickey3 tet fa testb
97. ort enter lt the port number which corresponds to Net MGT port LOM on the V210 and the MRV LX terminal server gt Note 1 For Net MGT LOM ports use terminal server ports 2100 2400 physical ports 1 4 For Serial ports use terminal server ports 3100 3400 physical ports 11 14 The port number identifies the location of the target host This value is based on the following formula 2000 Port number physically connected on the MRV LX terminal server x 100 For example if the target host is connected to port 9 of the MRV LX terminal server then the port number would be 2900 Port 12 is the port on the back of the MRV LX terminal server that translates to 3200 Note 2 Once the connection is established to the target host the communication between the user and the component is treated exactly like a console connection MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 44 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Powering on the servers Procedure 10 Powering on the servers At the server 1 ATTENTION Do not have any bootp servers on the same subnet of the system If there is such a server disconnect the LAN interface cable from the system subnet Turn power on to the server 2 If the system boots up log into the server as root 3 Type init 0 Enter This will bring you to t
98. ositive going threshold 2 Component Monitoring MAJOR default Threshold monitors Alarm Severity on Maximum Rate Component Monitoring MAJOR default Threshold monitors Alarm Severity on Upper Limit OverRun Component Monitoring MAJOR default Threshold monitors Alarm Severity on Lower Limit UnderRun MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 158 Table 40 Web Monitor tab Sheet 9 of 12 Component Monitoring unchecked default Threshold monitors Usage state affected Component Monitoring com nortelnetworks i default Class name ms mw probe iplanet planetThreadPoolHan dler Component Monitoring Thread Pool Stats default Component name Component Monitoring 1 default Polling interval in minutes Component Monitoring checked default Active for polling Component Monitoring percentThreadPoolUs default Threshold monitors age Gauge name Component Monitoring 100 default Threshold monitors Upper limit Component Monitoring 0 default Threshold monitors Lower Limit Component Monitoring 10 default Threshold monitors Negative going threshold value Component Monitoring 5 default Threshold monitors Negative going threshold hysteresis Component Monitoring 70 default Threshold monitors Positive going threshold value 1 NN42020 310 MCS 5100 3 5 Standard 1 0
99. ot applicable operating systems minimum Microsoft Windows 98 SE ME 2000 XP or Microsoft Windows NT 4 x with Service Pack 5 SP5 recommended Microsoft Windows 98 SE ME 2000 XP or Microsoft Windows NT 4 x with Service Pack 5 SP5 network connectivity Ethernet network card web browser with Microsoft Internet Explorer 6 0 or later version web browser with Netscape Communicator 7 0 or later version cookies enabled Javascript enabled NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 maererele gt 9 fe Copyright Nortel Networks Limited 2006 Setting up the baseline hardware Baseline hardware See the following figure for an overview of the hardware connectivity Figure 3 Hardware connections overview 2 serial connections each Terminal Server MgmtSvr Server RE Database Management Accounting odules Oracle Monitor 2 connections per server one per layer 2 switch 3rd party gateway Application server Server Mui SIP Application Module IPCM Provisioning Module System Web Client Manager Management iPlanet Monitor Console UFTP Base Software Media Application Server IP Phone 2004 QE IP Phone 2004 UM EH xe converged desktop SIP SIP PC PC client or client Web client ATTENTION You need an uninterrupted power source UPS If a power outage occurs bring the server for the Database Module into service before bringing the other servers into ser
100. panies the MCS product for CSI and system requirements Make a copy of the CSI datasheet from Appendix E of the MCS 5100 Network Deployment and Engineering Guide NN10313 191 Fill out the datasheet with relevant information from your system administrator You must have read and understood all the Release Notes before the installation begins Nortel Networks strongly recommends the use of high speed data network connectivity for optimum remote service capability Without broadband connectivity remote service options are limited Nortel Networks recommends the Contivity Remote Access Solutions for this function Nortel Networks also recommends following standard data center conventions for having a Universal Power Supply UPS as the power backup for the servers For more information refer to the MCS 5100 Network Deployment and Engineering Guide NN10313 191 which shows how to connect servers to two different UPS systems for maximum uptime For power over Ethernet in the closet switches Nortel Networks recommends use of the Ethernet Switch 460 Power Over LAN layer 2 Ethernet switches MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 18 The procedures in this Guide assume that you are using the PuTTY VT100 terminal emulator tool ATTENTION To set up sessions download from the web the PuTTY VT100 Emulator a shareware configurator tool Download PuT
101. ployment of the imssipdb load is command line driven from the MgmtSvr Updates to the imssipdb load in future loads will be handled through the System Management Console The following section describes the steps to watch the imssipdb deployment logs as the dbdeploy pl script executes The following commands are executed on the database server using PuTTY SSH into the machine logical IP address Example Open a PuTTY SSH session to 120 120 13 22 Procedure 45 Verifying the database load imssipdb deployment ATTENTION If the database deployment has completed this file will not exist At the management pc 1 Log into the database server as nortel lt new nortel user password gt 2 Execute the following command to tail watch the imssipdb deploy log micromgmt export home nortel gt tail f tmp SQL As the dbdeploy pl script executes a temporary log is created in the tmp directory on the database server Note that the SQL file in the tmp directory will not be present until after the dbdeploy pl script begins 3 While tailing the SQL temp file look for errors in the log file These errors could include statements such as error failed and so on If any error condition is encountered do not continue Contact support immediately 4 The imssipdb deployment is successful when the Server1 s dbdeploy pl script reports deployed successfully MCS 2 server Sun Fire V210 RoHS Solaris Inst
102. pted for in this section Deploying the MCS database load imssipdb After performing the steps for installing MCS Base Platform software and Oracle software an empty imsdb1 database is all that exists A database load must be deployed on the database machine Server 1 to define all of the MCS schemas and configurations Commands are executed on each server using PUTTY SSH into the machine logical IP address ex 120 120 13 25 The procedure to install the database load for the first time is command line driven and executed from the MgmtSvr Example Open a PuTTY SSH session to Server1 120 120 13 22 Procedure 21 Deploying the initial database load imssipdb At the management pc 1 Log into the MgmtSvr User name lt nortel gt Password lt your new password gt 2 Execute the following command dbdeploy pl Enter 3 Select the correct database load and press Enter 4 Is this a Replicated Database EnterN fora non redundant system MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 76 5 You will see the following message Select the Type of Deployment 1 Initial Deployment 2 Upgrade of Database 3 Rollback of Database 4 Install Files only to Select 1 for initial deployment then press Enter Enter Machine Logical IP Address Primary DE Enter the machine logical IP address of the MgmtSvr gt or press Enter to acc
103. r management services with an IP address that is in the same subnet of the IP address range used for the Sun Fire V210 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 13 Figure 4 Example of 2 server Sun Fire V210 Solaris system configuration Hostname Servert micromgmt Machine logical IP address 120 120 13 22 bgeD 120 120 13 20 BPS port 1 bgel 120 120 13 21 BPS port 2 LOMO in Reach port 2100 Serial MGT in Reach port 2200 PC for Mgmt Services 120 120 13 25 netmask z 255 255 255 0 COM1 connected to in Reach port 20 BPS port 10 Ethernet switch layer 2 switch 120 120 13 25 netmask 255 255 255 0 5423 ed 2 connections from each 2 connections from each In Reach Terminal Server 192 168 14 3 Hostnamoe Server2 microapp P T 255 255 0 Machine logical IP address 120 120 13 25 routerIP 120 120 13 1 bge 120 120 13 23 BPS port 3 netmask 255 255 255 0 bgel 120 120 13 24 BPS port 4 LOMO in Reach port 2300 Serial MGT in Reach port 2400 Example 2 server single network configuration Restrictions and limitations The 2 server V210 Solaris system is non redundant Since redundancy is not built into the system a server failure will result in the loss of services The 2 server V210 Solaris system has a mirrored disk In the event of a disk failure the failed disk should be replaced as soon as possible The 2 server V210 Solaris s
104. r your server When this process is complete click on Continue 22 The following example shows a summary of the features represented by all the sample authcodes entered This screen shows the current features enabled and the new features to be added to your server In a new installation there are no features displayed If the list is correct click on Continue NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 93 Figure 29 Keycode Retrieval System Summary of features Nortel Networks Customer Support Keycode Retrieval System Auth Code Generate Keycode Micro File Edit View Favorites Tools Help SBack Q A Search Favorites CBuistory Es amp gt Address ei http zcarsOss ca nortel com AuthCodeKkeyGen Go Links z Product Registration ia sae i AUR eee USER Best Customer TYPE Super User Gen Temp Keycode Retrieve Keycode GROUP All Customer Groups ned Sisi System ID 00 0A 47 36 01 1A 00 04 47 36 01 1B Feature Distributor Management End User Administration Software Version Software Version 1 1 7 amp Auth Code s 05006201 erms amp 5 Conditions Customer NORTEL NETWORKS 598 Step 3 Review the features to be added to your system and select continue You can contact us at to generate the keycode Select Cancel to return to the first page without i generating a keycode North America 1
105. rch Naticape Part Sacurty Shop af Merian L WebMail af Conrectons af Birdoumsi a Smartipisie GP Mitplace F Baotnarks Ga To http 111 111 111 111 I Whet s Read 4 i 4 EZMRV Commenicetions Inc In Reach Welcome to the LX Series Configuration Console Choosing Encrypted Console means the Graphical User Interface GUI will run slower but with security Encrypted and Not Encrypted Console also require Java Runtime Environment 1 4 or later Choosing Not Encrypted Console means the GUI will run faster but without security Note The Java cache in JRE 1 4 is set to ON by default There is a known problem within JRE 1 4 0 and 1 4 1 regarding cache functionality which requires you to disable the cache On your management pc select Start gt Programs gt Settings gt Control Panel open the Java Plugin 1 4 0 icon and click the Cache tab At the Cache window click theClear Cache button and uncheck the Enable Caching checkbox Click OK This issue is fixed in JRE 1 4 2 5 Select Encrypted or Not Encrypted and then select Load A login window appears MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 36 Figure 12 Login window Username Password 6 Enter your Username and Password and click Login Note By default authentication is done against the local user database To start use the known username nReach and password
106. ress and primary machine logical IP address or type 0 0 0 0 instead Enter the lt Machine Logical IP Address of the other MgmtSvr gt in dot notation format Example 120 120 13 22 Enter the lt service logical IP address of the SysMgr gt in dot notation format Example 120 120 13 22 Enter the lt service logical IP of the AcctMgr gt in dot notation format Example 120 120 13 22 You have entered the following IP addresses Machine Logical IP Address of the other MgmtSvr 120 120 13 22 Service Logical IP Address of SysMgr 120 120 13 22 Service Logical IP Address of AcctMgr 120 120 13 22 Is this information correct y n If the information is correct press Y and Enter You are now configuring the Syslog daemon Press Enter to continue Is this the Primary Accounting Server Machine in a DUPLEX configuration Y N Select N and Enter Press Enter to configure the LOM port You will need to enter the following information e IP address for the Physical Ethernet Net Management port e Netmask for the Physical Ethernet New Management port Gateway IP address Note If the Net Management port was previously configured the IP address Netmask address and Gateway address are shown as the defaults for the entries in steps 24 25 and 26 below Press Enter to accept the default IP addresses MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks L
107. rface gt Enter Example 120 120 13 20 Enter the secondary machine physical IP address for the bge1 interface lt Physical IP address of the bgel interface gt Enter Example 120 120 13 21 Enter the lt machine logical IP addresses of the servers that are the ping targets Note Do not enter the IP address of the server you are working on IP Multipathing needs a set of reliable hosts to ping against Select a set of three IP addresses in this subnet that belong to reliable nodes such as fault tolerant servers Select the three nodes from the following list in order of preference For IPMP GROUPS e Machine Logical IP address of the database server e Machine Logical IP address of the Management server e Machine Logical IP address of the CAM server e BPS stack IP address e Other optional devices PRI Gateway host MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 58 Provide between two and six ping targets or each IPMP group for proper IPMP failover reliability Enter the address 0 0 0 0 to indicate list is complete if entering less than six targets Enter ping target 1 120 120 13 25 Enter ping target 2 120 120 13 1 Enter ping target 3 0 0 0 0 Note Do NOT use this server s own IP address as a ping target Press Enter after each IP address 14 The configuration information will come up as shown in the following figure Figur
108. s available until after CD5 completes Once CD5 has completed log out of the Net MGT LOM port Log back in through the terminal server to the Serial MGTport for the rest of the installation For installations on machines that have already had a system installed just remain on the Serial MGT port After the AppSvr IPCM reboot log into this server using the Serial MGT port and change the passwords for the sysadmin root and nortel users Change the passwords on the MgmtSvr AcctMgr server after CD6 not CD5 MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 66 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Maletolele gt le O1 Copyright Nortel Networks Limited 2006 Enabling or disabling the automatic mount Use the following procedure if you need to use the CD ROM auto mount after installation of CD5 Execute this procedure on the MgmtSvr Server1 ATTENTION Keep this procedure for future use Procedure 18 Enabling or disabling the CD ROM auto mount At the management pc 1 The system disables volmgt by default after CD5 is installed To toggle it back on to install additional CDs follow this step Log in as rootfrom the console and type the following command etc init d volmgt start 2 When you finish mounting the additional disk s remember to disable the volume manager for better security To disable it
109. s 1 5 have four copies each Disk 6 only needs to go on Server 1 the server on which the Management and Accounting Modules reside There are six Oracle disks with one copy going on Server 1 the server on which the Database Module resides NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 21 MCS Base Platform System Software disks are loaded on the following servers as indicated in Table 2 Mapping of Kit NTVWO1BD disks to servers with times Table 2 Mapping of Kit NTVWO1BD disks to servers with times CD1 Disk Partitioning amp Solaris OS 45 minutes X X Kernel CD3 Solaris Packages and Patches CL inte MCP Installation amp 30 minutes Commissioning CD5 MCP Base Platform amp 3rd Party 30 minutes Software Total approximate time for each 3 6 hours for each server server plus 90 minutes Oracle installation on Database server MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 22 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 Minimum and recommended requirements for customer provided PC Configure your management pc to have an IP address that is in the same subnet of the IP address range used for your servers Check your pc vendor s documentation to learn how to configure the PC s IP address Minimum and recommended requirements for the c
110. serial port which is set for access local or dynamic a Hit the return key several times to autobaud if autobaud is enabled the port and get the login prompt b Enter your login name The default is nHeach Enter your password The default is access Procedure 7 Changing the password defaults At the management pc 1 The default password for the MRV LX terminal server user is access If an unauthorized user knew this username password combination that user could log on to your unit For this reason you should change the user s password to something other than access The default Superuser password is system To reduce the risk of an unauthorized user gaining access to the Superuser Command Mode MRV recommends that you change this password to something other than system To change the user level password access the Configuration Command Mode Access the Subscriber Command Mode for the subscriber by entering the subscriber command with InReach as the command argument for example Config 0 gt gt subscriber InReach Enter the password command at the Subs InReach gt gt prompt NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 41 4 Enter a new user password at the Enter your NEW password prompt The password will be displayed as asterisks Re enter the new user password at the Re Enter your NEW password prompt The password will be displayed as asterisks To ch
111. ss 120 120 13 20 its subnet mask is ffffffOO which translates to 255 255 255 0 and the interface is UP active 4 Look for the entry which starts with bge1 The parameters that follow show the IP address subnet mask and whether the interface is UP This example output shows that bge1 is assigned to IP address 120 120 13 21 its subnet mask is ffffff00 which translates to 255 255 255 0 and the interface is UP active 5 Look for the entry which starts with bgeO 1 This is the machine logical interface Notice that the machine logical has attached itself to bgeO and added a suffix of 1 creating bge0 1 When a machine logical or service logical interface is created the V210 will always attempt to attach to the first interface bgeO If bgeO were unavailable or out of service the machine logical would then attach itself to bge1 creating bge1 1 The parameters which follow show the IP address subnet mask and whether the interface is UP This example output shows that bge0 1 is assigned to IP address 120 120 13 22 its subnet mask is ffffff00 which translates to 255 255 255 0 and the interface is UP active 6 Verify that the host file is correct micromgmt export home nortel gt cat etc hosts Internet host table 127 0 0 1 localhost 120 120 13 22 micromgmt loghost 120 120 13 20 micromgmtbgeO 120 120 13 21 micromgmtbge1 The first 120 address should reflect your machine logical IP addr
112. st 120 120 13 255 groupname imspub bge0 1 flags 1000843 lt UP BROADCAST RUNNING MULTICAST IPv 4 gt mtu 1500 index 2 inet 120 120 13 25 netmask ffffff00 broadcast 120 120 13 255 bge1 flags 69040843 lt UP BROADCAST RUNNING MULTICAST D EPRECATED IPv4 NOFAILOVER STANDBY INACTIVE mtu 1500 index 3 inet 120 120 13 24 netmask ffffff00 broadcast 120 120 13 255 groupname imspub Look for the entry that starts with bgeO The parameters that follow show the IP address subnet mask and whether the interface is UP This example output shows that bgeO is assigned to IP address 120 120 13 23 its subnet mask is ffffff00 which translates to 255 255 255 0 and the interface is UP active MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 166 4 Look for the entry that starts with bge1 The parameters that follow show the IP address subnet mask and whether the interface is UP This example output shows that bge1 is assigned to IP address 120 120 13 24 its subnet mask is ffffff00 which translates to 255 255 255 0 and the interface is UP active Look for the entry that starts with bge0 1 This is the machine logical interface Notice that the machine logical has attached itself to bgeO and added a suffix of 1 creating bge0 1 When a machine logical or service logical interface is created the V210 will always attempt to attach to
113. t handler name Active checked default 3 Use the values from the table that follows to complete the Database Base tab parameters The shaded rows indicate values that must be addressed by the installer Table 38 Database Base tab Connections 1 default Secondary Host leave blank default Use the values from the table that follows to complete the Oracle Listeners tab parameters NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 147 The shaded rows indicate values that must be addressed by the installer Table 39 Oracle Listeners tab SNMP request port 9161 Fo default Active checked default Component Monitoring OracleListeners default Component name Component Monitoring 1 default Polling interval min Active checked default 4 Click Apply The component will deploy Wait until you see the dialog box indicating successful installation The component will appear in the file tree MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 148 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Maletolere gt le O1 Copyright Nortel Networks Limited 2006 Installing the iPlanet Monitor Prerequisites Make sure the System Management Console has been successfully installed and started Procedures Procedure 41 Adding th
114. the first interface bgeO If bgeO were unavailable or out of service the machine logical would then attach itself to bge1 creating bge1 1 The parameters that follow show the IP address subnet mask and whether the interface is UP This example output shows that bge0 1 is assigned to IP address 120 120 13 25 its subnet mask is ffffffOO which translates to 255 255 255 0 and the interface is UP active Verify that the hosts file is correct microapp export home nortel gt cat etc hosts Internet host table 127 0 0 1 localhost 120 120 13 25 microapp loghost 120 120 13 23 microappbgeO 120 120 13 24 microappbge1 The first 120 address should reflect your machine logical IP address in addition to the hostname and the loghost tag The second 120 address should reflect the bgeO interface followed by the hostname concatenated with bgeO The third 120 address should reflect the bge1 interface followed by the hostname concatenated with bge1 Verify the defaultroute file microapp export home nortel gt cat etc defaultrouter 120 120 13 1 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 167 The only address in this file defines your default gateway route your router If this file is empty and the machine is rebooted then you will not have network access to your other servers Verifying the database load imssipdb deployment The initial de
115. tion Portfolio MCP system geared towards an environment with a maximum of 250 subscribers This system allows more effective cost management for smaller sized enterprises This document describes the installation of the 2 server Sun Fire V210 Solaris system The 2 server Sun Fire V210 Solaris system must be connected to a 100 MB full duplex Ethernet switch The IP configuration consists of one public IP address The following figures show the possible network configurations Figure 1 2 server network with redundant Ethernet switches Ethernet switch 100 BT Sun Fire V210 Power cable Crossover cascade Sun Fire V210 Ethernet switch Protected power source MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 12 Figure 2 2 server network with single Ethernet switch Sun Fire V210 sage Power cable Sun Fire V210 I Ethernet switch Protected power source Figure 3 2 server network MAS Ad hoc audio conferencing with single Ethernet switch Ethernet Switch 100 BT Power cable IBM X336 Protected Power Source The rest of this document will refer to the example data in the figure that follows Print and refer to this example while executing this installation Print and complete the CSI datasheet with your own configuration to assist in executing this installation Configure the pc you are using fo
116. ucture on the left and a general information area on the right Each folder on the management console tree is represented as a Network Element and each has a different functionality MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 102 NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 meaererele gt e O1 Copyright Nortel Networks Limited 2006 Adding a server Prerequisites The System Management Console has been successfully installed and started Adding a server Use this procedure to add each of your servers Note You should view the content of this chapter as reference information When you perform the procedures in the next three chapters in this document you will be asked to return to this chapter Procedure 27 Adding a server At the System Management Console 1 Select Sites gt MgmtSite gt Servers 2 Right click on the Servers folder 3 Select Add gt General 4 Use the following system server fields to complete the General server window that appears Note The shaded rows indicate values that must be addressed by the installer Server Name The name that will appear from the lt servername gt management console Host Name Name A name A name unique within your domain within your domain Imicronmt EE NE field Describes the physical Sa location of the server Latitude Optional field Describes the latitudinal de
117. ustomer provided management PC include assuming you are not running anything else on the pc e processor minimum 600 MHz Pentium class or equivalent processor recommended 1 0 GHz or higher Pentium class or equivalent processor e free RAM minimum 64MB of RAM This requirement is in addition to the memory requirements of the operating system and other concurrent applications recommended 64MB of RAM This requirement is in addition to the memory requirements of the operating system and other concurrent applications e free hard disk space minimum 50MB If the System Management Console is installed on a drive other than drive C then 50MB of free space is required on that drive as well In this case the free 50MB on drive C will not be used but is required for the installation to complete successfully recommended 50MB If the System Management Console is installed on a drive other than drive C then 50MB of free space is required on that drive as well In this case the free 50MB on drive C will not be used but is required for the installation to complete successfully CD ROM drive required MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 24 mouse required e Video Graphics Card minimum 640x480 8bpp 256 colors VGA recommended 800x600 Q 16bpp 65 536 colors VGA or better e sound card n
118. vice If other servers do not come up restart the server for the Management Module MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 26 Hardware required for the 2 server system consists of the following terminal server 1 MRV LX 4008 101AC including Linux based secure console standalone unit with 8 RS232 RJ45 ports internal V 90 modem and AC power software and documentation on CD ROM core servers 2 Sun Fire V210 servers including 1 1 34 GHz UltraSPARC Illi Processor with 1 MB On Chip L2 Cache 1 GB Memory 2 swappable 73 GB Ultra 160 SCSI disks second disk for mirroring CD ROM 2 10 100 Mbit Ethernet and USB Ports System configuration card Solaris 8 and ALOM v1 5 pre installed two 2 cat 5 Ethernet cables for each V210 server for a total of four 4 ethernet cables Note Each V210 server uses two 2 ethernet cables to connect the V210 servers to the layer 2 switch two 2 serial RS232 cables for each V210 server or a total of four 4 serial cables Note Serial cables are ordered with the MRV LX terminal server one 1 cable for Serial Net MGT LOM port one 1 cable for Serial MGT port Sun Fire V210 server documentation Media Application Server 1 IBM x336 2 3 6 GHz Xeon 1 GB RAM 1 73 GB SCSI drive Windows 2000 Multimedia PC Clients NN42020 3
119. x errors you receive You will set the time zone and additional information in the next procedure Solaris Installation Program Page 1 Press Esc then press the number 2 Esc 2 to continue Note f you are using a direct console connection to the SUN terminal use the F2 key 2 Press Esc 2 to continue NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 49 Network Connectivity Networked 3 Accept the default yes by pressing Esc 2 to continue DHCP Use DHCP 4 Accept the default No by pressing Esc 2 to continue Primary Network Interface Primary Network Interface 5 Choose bge0 as the primary network interface and press Esc 2 to continue Host name Host name 6 Enter the host name of the server for example micromgmt Note 1 Host name cannot start with a number Host names must be at least two characters and can contain alphanumeric characters and minus signs Note 2 Host names must be unique within your domain Creating a duplicate host name will cause problems on the network after you install Solaris Press Esc 2 to continue IP Address 7 ATTENTION Make sure you enter the machine logical IP address for this system It must be unique and follow your site s address conventions Enter the machine logical IP address Example 120 120 13 22 Press Esc 2 to continue Subnets System part of a subnet 8 Accept the default ves by pressing Esc 2 to continu
120. ystem It will cause it to revert to a blank system It will not have a name or know about other systems or networks This program will also halt the system Do you want to continue y n The system assumes the answer is Y The system will reboot and come up to the boot prompt ok The system is now ready to re configure You can type poweroff at the ok prompt if you wish to power the machine off To reconfigure the server at this point if you are at the boot prompt ok enter the boot command If you are not at the boot prompt power on the server To do so you can press the power on button on the server or connect to the LOM port and type poweron When the server is back up you will see the following question What type of terminal are you using 1 ANSI Standard CRT 2 DEC VT100 3 PC Console 4 Sun Command Tool 5 Sun Workstation 6 7 X Terminal Emulator xterms Other a Toa erro Tf NN42020 310 MCS 5100 3 5 Standard 1 0 June 2006 Copyright Nortel Networks Limited 2006 173 Type the number of your choice and press Return Select 2 and press Enter 7 See the instructions for installing Disk 1 in this document for more information on what to enter for the following items e Networked e DHCP e Primary Network Interface e Hostname You may have to backspace over the word unknown and type in the correct name e P Address e Subnet e Netmask e iPV6 e Confirm e Security Policy e Conf
121. ystem has the following limitations The system supports a maximum of 250 subscribers e Supported conference ports consist of 30 G 711 or 10 G 729 e Only Ethernet interfaces 0 and 1 are supported The system does not support live upgrades e System maintenance starting or stopping of components is not supported while the system is live Doing any maintenance while the system is live may have adverse effects on call processing e Two server to four server migration is not supported MCS 2 server Sun Fire V210 RoHS Solaris Installation and Commissioning Guide Copyright Nortel Networks Limited 2006 14 MCS 5100 documentation Refer to the MCS 5100 Network Deployment and Engineering Guide NN10313 191 that accompanies the MCS 5100 product and to your customer specific information CSI datasheet for your system requirements For more information on component installation and commissioning tasks refer to the specific component documentation MCS 5100 Accounting Module Basics NN10279 111 MCS 5100 SIP Application Module Basics NN10259 111 MCS 5100 Database Module Basics NN10267 111 MCS 5100 Management Module Basics NN10268 111 MCS 5100 Provisioning Module Basics NN10274 111 MCS 5100 Provisioning Client User Guide NN42020 105 MCS 5100 H 323 Gatekeeper Basics NN10280 111 Media Application Server Network Engineering and Deployment Guide NN10377 191 MCS 5100 Ad Hoc Audio Conferencing Service Guide NN10297 111 M