1. The POTS splitter can be placed m On the outside of the structure near the NID or punchdown block or m Inside the building When mounted outside the POTS splitter must be installed at or above the height of the NID and should be a minimum of three feet above ground At the front of the housing align the housing to open from the right with the rubber grommet for cable access facing downward Place the housing upright as shown Use a Phillips head or combination Phillips slotted head screwdriver and the screws included in the package If mounting to POTS Splitter Housing Cement or cinder block use a drill and and 3 16 masonry drill bit to install the two plastic anchors first Then install the two 8 15 x 1 Type A screws Wood install only the two 8 15 x 1 Type A screws and discard the plastic anchors A 97 15247 Preparing the POTS Splitter B gt Procedure 1 Unscrew the closure screw and open the housing by pressing on the lever on the right above the closure screw 2 Remove the rubber grommet at the base of the POTS splitter 3 Make a small diagonal cut in the rubber grommet to feed the wiring through 4 Replace the rubber grommet at the base of the POTS splitter Rubber Grommet Closure Screw 97 15437 01 Installing the POTS Splitter Wiring The local loop ends at the punchdown block or NID Wiring must be connected from the customer
2. But if advance notice is not practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with the Telephone Line Filter for repair or warranty information please refer to Warranty Sales and Service Information No repairs may be performed by the end user The equipment can not be used on public coin phone service provided by the telephone company Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Warranty Sales and Service Information Contact your sales or service representative directly for any help needed For additional information concerning warranty sales service repair installation documentation or training use one of the following methods Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com Via Telephone Call our automated call system to receive current information via fax or to speak with a company representative
3. Within the U S A call 1 800 870 2221 International call 813 530 2340 5030 A2 GN10 10 12
4. premises CP side of the punchdown block or NID to the DSL jack Typically the punchdown block is installed in commercial locations and the NID is installed in residential locations The following is an example of a punchdown block Punchdown Block Customer Premises Wiring to Demarcation Point DSL Jack Jumper Wiring to POTS Splitter for POTS Bridge Clip DSL POTS From Local Loop L D LD Ls L D L D D 97 15349 B gt Procedure 1 Access the punchdown block or NID 2 Disconnect the POTS access wiring from the local loop A WARNING Do not continue unless the DSL access line from the local loop has been disconnected at the NID or punchdown block Refer to Important Safety Instructions page 10 Green T1 and Red R1 are the standard pair wiring colors used in the next two NID illustrations for Tip T1 and Ring R1 Your wiring may differ Telephone Network Interface Device NID Customer Premises Demarcation Point aN ee a S ll Z Tip L T1 Uii Green mi Ring ral rea ll i Red z 0 0 _ DSL POTS Existing POTS From Local Wiring to Loop Telephone Ground as Disconnect the POTS wiring to the telephone from the T1 R1 connectors on the customer premises side Feed the disconnected POTS wiring through the POTS splitter r
5. PARADYNE HotWire 5030 POTS Splitter Customer Premises Installation Instructions Document Number 5030 A2 GN10 10 October 1997 Before You Begin Verify that L The local loop POTS service is connected to the POTS DSL network at the punchdown block or network interface device NID 1 New or existing unshielded twisted pair wiring CATS or better is used with this product The CAT3 wiring must meet EIA TIA 568 specifications with 24 AWG 5 mm or 26 AWG 4 mm For RADSL Rate Adaptive Digital Subscriber Line RTU installation information refer to the appropriate RTU document Document Number Document Title 5216 A2 GN10 HotWire 5216 Remote Termination Unit RTU Customer Premises Installation Instructions 5246 A2 GN10 HotWire 5246 Remote Termination Unit RTU Customer Premises Installation Instructions 5446 A2 GN10 HotWire 5446 Remote Termination Unit RTU Customer Premises Installation Instructions Package Checklist Verify that your package contains the following 1 POTS splitter and housing with closure screw _1 Small plastic bag with two 8 15 x 1 Type A combination Phillips slotted head screws and two 1 plastic anchors 1 Warranty card Tools Required L Flat blade screwdriver to tighten terminal screws L 3 8 nut driver to close housing securely J Phillips head or combination Phillips slotted head screwdriver to mount the housing J Drill and 3 16 drill bit to mount the housing in ce
6. ment or cinder block 1 What Does the POTS Splitter Do The POTS splitter and HotWire Remote Termination Unit RTU are components in the RADSL Access System This system provides high speed Internet or corporate LAN access over traditional twisted pair copper telephone wiring The POTS splitter filters out the DSL signal and allows the POTS frequencies to pass through The RADSL RTU and telephone can function simultaneously over the same pair of copper wires at the customer premises when a POTS splitter is used at both ends of the local loop Copper pairs run from the central office to the customer premises to create the local loop The local loop terminates on the customer premises at the demarcation point in a punchdown block or NID Wiring is connected from the demarcation point to the POTS splitter and to the DSL jack Wiring also connects the demarcation point to an RJ11 wall jack for DSL access by the RTU Customer Premises CP m Se 7 Demarcation Point 1 CP cf x Oe cue Pon TENS 1 plitter Central M fi B F Office nd user CO Systems Local Loop Network Service Ethernet Provider Cable Cable NSP Punchdown Block or NID HUB le ee ee 97 15346 01 DSL Digital Subscriber Line POTS Plain Old Telephone Service NID Network Interface Device RTU Remote Termination Unit Baie sin New Wiring Connections Existing Wiring POTS Mounting the POTS Splitter Housing
7. s Four terminal screws Technical Specifications subject to change without notification 10 Important Safety Instructions 1 Read and follow all warning notices and instructions marked on the product or included in the manual 2 This product is intended to be connected to Listed Certified telephone wiring with a minimum of 24 AWG 5 mm behind a Listed Certified primary protector 3 Do not attempt to install or service this product yourself as opening or removing covers may expose you to dangerous high voltage points or other risks Refer all installation and servicing to qualified service personnel 4 When installed in the final configuration the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 5 In addition since the equipment is to be used with telecommunications circuits take the following precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Avoid using a telephone other than a cordless
8. type during an electrical storm There may be a remote risk of electric shock from lightning Do not use the telephone to report a gas leak in the vicinity of the leak Notice to Users of the Telephone Network This equipment complies with Part 68 of the FCC rules On the inside of the equipment s enclosure is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipment If requested this information must be provided to the telephone company This equipment is intended to be hard wired to the telephone line s primary protector and to the inside building wiring If the primary protector utilizes an RJ11C jack for the inside building wiring connection connection to the protector must be made using a Part 68 compliant telephone line cord spade terminal to RJ11C plug The REN is used to determine the quantity of devices which may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total RENs contact the local telephone company 11 If the Model 5030 Telephone Line Filter causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required
9. ubber grommet access opening created at the base of the POTS splitter Connect the wiring to the right side labeled PHONE Attach green to P3 and red to P4 Tighten both terminal screws with a flat blade screwdriver POTS Splitter LINE PHONE P4 To Telephone 97 15257a Reconnecting to the Local Loop B gt Procedure 1 Feed new jumper wiring through the POTS splitter rubber grommet Remove the insulation at the end of the wiring 2 On the left side labeled LINE attach red to terminal screw P1 and green to terminal screw P2 Tighten both terminal screws with a flat blade screwdriver POTS Splitter PHONE New Wiring from Punchdown Block or NID To Telephone 97 15257 01 3 Locate the T1 R1 connectors on the customer premises side of the punchdown block or NID where the existing POTS wiring was removed in Step 3 on page 6 Attach the jumper pair from P1 P2 labeled LINE in the POTS splitter to the T1 R1 connectors Telephone Network Interface Device NID Customer Premises Demarcation Point 2 me No i T1 Green I 2 l li Ring E R1 Z Red i 0 Wiring to I DSL POTS Jumper Wiring to een a POTS Splitter 5 for POTS roun S 4 Snap the lever shut to close the POTS splitter 5 Use the 3 8 nut driver on the closure screw to securely close the housing Lever X Clos
10. ure Screw 97 15251 DSL Access Wiring B gt Procedure 1 Attach new wiring to the T1 R1 connectors that will go to the DSL jack from the punchdown block or NID 2 Tighten the T1 R1 terminal screws with a flat blade screwdriver POTS Splitter Customer Premises Punchdown Block or NID a Central DSL Office v RJ11 6 Jack POTS DSL ve Local Loop Twisted Pair Wiring Demarcation Point 97 15485 You are now ready to run the specified wiring to the RTU location and install a DSL wall jack To install an RTU refer to the HotWire 5446 Remote Termination Unit RTU Customer Premises Installation Instructions If the RTU is not being installed at this time reconnect the local loop wiring at the demarcation point 5030 POTS Splitter Technical Specifications Item Specification Height x Width x Depth 6 65 x 5 44 x 2 25 16 89 cm x 13 82 cm x 5 72 cm Weight 10 2 ounces 289 2 grams Approvals FCC Part 68 Safety Certifications Refer to the equipments label for Registration Number Refer to the equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 40 F to 140 F 40 C to 60 C 40 F to 158 F 40 C to 70 C 5 to 95 noncondensing Withstands normal shipping and handling Interface Connector
Download Pdf Manuals
Related Search
Related Contents
Hypertec N15848KHY User's Manual 231641f Own Man Deep Well Sub - Les Puits Deux miRZip™ Lentivirus Pool of Anti- MicroRNAs User Manual Franke CPX 611-96 Extron electronic DA2 User's Manual Service manual - free boiler manuals Operating Instructions - Mahlkönig GmbH & Co KG VOTRE RÉGION Ils veulent piéger les sangliers Copyright © All rights reserved.