Nortel Networks NN46200-301 User's Manual
Contents
1. 1 Using a Phillips screwdriver loosen the two captive screws that fasten the power filler panel to the chassis until the screws are free of the threads in the chassis frame 10454FA Pull the power filler panel out of the Ethernet Routing Switch 8300 Series chassis Save the power filler panel in case you need to operate the Ethernet Routing Switch 8300 Series chassis with a power supply removed End To install a power filler panel Step Action 1 2 Place the power filler panel in the empty power supply bay Tighten the two captive screws until the power filler panel is seated firmly Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 18 Power supply installation 10453FA End Installing the AC power supply Install the AC power supply to provide AC power for components Do not install the 88301AC power supply and the 8302AC power supply within the same chassis This configuration is not supported When you first install a 8000 Series chassis that requires two power supplies you must turn on both power supply units within 2 seconds of each other If you wait longer to turn on the second power supply both power supplies shut down To correct this condition turn off both power supplies wait at least 30 seconds and then turn on both power supplies again within 2 s
2. Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 316797 C Rev 01 Document status Standard Document version 03 01 Document date 27 August 2007 Copyright 2007 Nortel Networks All Rights Reserved Sourced in Canada and the United States of America The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Nortel Networks Inc Restricted rights legend Use duplication or disclosure by the United States Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 Notwithstanding any other license agreement that may pertain to or accompany the delivery of this computer software the rights of the United States Government regarding its use reproduction and disclosure are as set forth in the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 Statement of conditions In the interest of improving internal design operational function and or reliability Nortel Networks Inc reserves the right to make changes to the products described in
3. 20 ms DC Output Power Ratings Max output power combined 1140W 1050W 90W fans 1770 W 1680W 90W fans Non PoE 3 3 VDC 150A 3 3 VDC 150A 12 VDC 65 A 12 VDC 65 A Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 24 Appendix Electrical specifications for the AC power supply Note the following information e The maximum steady state output power is limited to a total of 1140 W for any combination of output voltages currents at low line 100 120 VAC nominal input voltage conditions e The maximum steady state output power is limited to a total of 690 W for any combination of output voltages currents excluding the 50 VDC source at low line 100 120VAC nominal input voltage conditions This limitation is required to ensure that there is sufficient PoE power or 450 W total at this input voltage condition The maximum steady state output power is limited to a total of 870W for any combination of output voltages currents excluding the 50 VDC source at high line 200 240VAC nominal input voltage conditions This limitation is required to ensure maximum PoE power or 900 W total for the 50 VDC source at this input voltage condition To obtain the full output power rating of 1770 W you must connect the power supply to a nominal 200 240VAC input voltage source The following table list the power specifi
4. a redundant power supply power available for PoE is always determined on an N 1 redundancy If you have 1 or 2 power supplies in the chassis you will be allocated PoE power equivalent to one power supply If you have 3 power supplies in the chassis you will be allocated PoE power equivalent to 2 power supplies 8306 8310 chassis available system power Number Power supply of rating power Redundancy _ 8301AC 8302AC 100 120VAC 1140W 600 W 450 W M Yes 1 1 Yes 2 1 600 W 1290 W 450 W 900 W 200 240VAC 1770W 100 120VAC 850W 200 240VAC 1400W i jN Yes 1 1 Yes 2 1 Yes 1 1 Yes 2 1 No Yes 1 1 780 W 780 W 1650 W 535 W 535 W 1160 W 860 W 860 W 900 W 900 W 1800 W 225 W 225 W 450 W 450 W 450 W Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Removing and installing a power filler panel 17 Removing and installing a power filler panel A power filler panel maintains the proper cooling airflow in the Ethernet Routing Switch 8300 Series chassis If you remove a power supply from the Ethernet Routing Switch 8300 Series chassis without replacing it you must install a power filler panel When you install a power supply you must first remove the power filler panel from the power bay To remove a filler panel Step Action
5. exit to exit to Global Configuration mode Accessing the NNCLI When you first power up the Ethernet Routing Switch 8300 the default interface is the Ethernet Routing Switch 8300 CLI To switch from the CLI to the NNCLI you must change the NNCLI boot flag to true and save the boot configuration file using the following commands ERS 8310 5 config boot flags nncli true ERS 8310 5 save boot You must reboot the switch for this change to take effect After you reboot the switch access the NNCLI using Telnet rlogin or the local console port You can log in to the switch using your password and the default privilege password nortel Use the following commands to e log in to the software using the default user name and password e access Global Configuration mode Login XXXXX Password XXXXX ERS 8310 5 gt enable Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 10 Preface Password nortel ERS 8310 5 configure terminal ERS 8310 5 config Returning to the CLI The config cfg file for the CLI and the config cfg file for the NNCLI are not compatible If you decide to change the CLI mode to NNCLI or the reverse you must use the config cfg file for the selected mode To switch from the NNCLI to the CLI enter the following commands ERS 8310 5 config no boot flags nncli ERS 8310 5 config exit ER
6. supply S 10221 FA Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Power supplies 15 The following table describes the power supply LED on the AC power supply Table 2 Power supply LEDs Meaning Power supply not operational Contact your Nortel Technical Solutions Center On green Power supply is ok The Ethernet Routing Switch 8300 chassis ships with no installed power supplies Install the first power supply in the leftmost bay Power supply bays are logically numbered 1 2 and 3 left to right as viewed from the front of the chassis for the 8306 and 8310 Do not install the 88301AC power supply and the 8302AC power supply within the same chassis This configuration is not supported For the 8306 and 8310 chassis the number of power supplies that you need to install 1 2 or 3 depends on the following e the number of modules installed in the chassis e PoE requirements e whether you want an optional redundant power supply or not Table 3 Recommended 8301 AC 8302AC power supplies page 15 lists the number of 8301AC or 8302AC power supplies to install based on the number of installed modules and your power supply redundancy choice To provide the required PoE for powered devices PDs use Table 4 8306 8310 chassis available system power page 16 to determine the source input p
7. AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 12 Preface You can print the technical manuals and release notes free directly from the Internet Use Adobe Acrobat Reader to open the manuals and release notes search for the sections you need and print them on most standard printers Go to Adobe Systems at the www adobe com URL to download a free copy of the Adobe Acrobat Reader How to get help If you purchased a service contract for your Nortel product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller for assistance If you purchased a Nortel service program contact Nortel Technical Support To obtain contact information online go to the www nortel com contactus web page and click Technical Support Information about the Nortel Technical Solutions Centers is available from the www nortel com callus web page An Express Routing Code ERC is available for many Nortel products and services When you use an ERC your call is routed to a technical support person who specializes in supporting that product or service To locate the ERC for your product or service go to the www nortel com erc web page Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Power supply installation This guide contains informat
8. S 8310 5 config save boot You must reboot the switch for this change to take effect Text conventions This guide uses the following text conventions angle brackets lt gt bold body text bold Courier text braces Indicate that you choose the text to enter based on the description inside the brackets Do not type the brackets when entering the command Example If the command syntax is ping lt ip_address gt you enter ping 192 32 10 12 Indicates objects such as window names dialog box names and icons as well as user interface objects such as buttons tabs and menu items Indicates command names options and text that you must enter Example Use the dinfo command Example Enter show ip alerts routes Indicate required elements in syntax descriptions where there is more than one option You must choose only one of the options Do not type the braces when entering the command Example If the command syntax is show ip alerts routes you must enter either show ip alerts or show ip routes but not both Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Hard copy technical manuals 11 brackets ellipsis points italic text plain Courier text separator gt vertical line Hard copy technical manuals Indicate optional elements in syntax des
9. cations for the Ethernet Routing Switch 8302AC power supply Table 6 Ethernet Routing Switch 8302AC power specifications Frequency range nominal thermal output Non PoE 3 3 VDC 150A 3 3 VDC 150A 12 VDC 65 A 12 VDC 65 A Fans 12 VDC 7 5A 12 VDC 7 5A Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Appendix Electrical specifications for the AC power supply 25 Note the following information e The maximum steady state output power is limited to a total of 850 W for any combination of output voltages currents at low line 100 120 VAC nominal input voltage conditions e The maximum steady state output power is limited to a total of 625 W for any combination of output voltages currents excluding the 50 VDC source at low line 100 120VAC nominal input voltage conditions This limitation is required to ensure that there is sufficient PoE power or 225 W total at this input voltage condition The maximum steady state output power is limited to a total of 950 W for any combination of output voltages currents excluding the 50 VDC source at high line 200 240VAC nominal input voltage conditions This limitation is required to ensure maximum PoE power or 450 W total for the 50 VDC source at this input voltage condition e To obtain the full output rating of 1400 W you must connect the power supply to a nom
10. criptions Do not type the brackets when entering the command Example If the command syntax is show ip interfaces alerts you can enter either show ip interfaces or show ip interfaces alerts Indicate that you repeat the last element of the command as needed Example If the command syntax is ethernet 2 1 lt parameter gt lt value gt you enter ethernet 2 1 and as many parameter value pairs as needed Indicates variables in command syntax descriptions Also indicates new terms and book titles Where a variable is two or more words the words are connected by an underscore Example If the command syntax is show at lt valid_route gt valid_route is one variable and you substitute one value for it Indicates command syntax and system output for example prompts and system messages Example Set Trap Monitor Filters Shows menu paths Example Protocols gt IP identifies the IP command on the Protocols menu Separates choices for command keywords and arguments Enter only one of the choices Do not type the vertical line when entering the command Example If the command syntax is show ip alerts routes you enter either show ip alerts or show ip routes but not both You can download current versions of technical documentation for your Ethernet Routing Switch 8300 from the Nortel customer support web site at www nortel com support Nortel Ethernet Routing Switch 8300 Installation
11. e or the Interface configuration mode all the configuration parameters both global and interface can be saved to a file The default name for the configuration parameters file is config cfg Alternative filenames can also be used Table 1 NNCLI command modes page 9 lists the NNCLI command modes the prompts for each mode the abbreviated name for each mode and how to enter and exit each mode Prompts are expressed in this table using the format ERS 8300 5 however prompts returned from your switch typically reflect the specific chassis you use For example if you use the 8310 chassis the prompts use the format ERS 8310 5 Prompts can be customized also using the NNCLI command snmp server name lt prompt gt Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Command line interfaces 9 Table 1 NNCLI command modes Command Mode Command mode Prompt A mode name to enter or exit mode User EXEC ERS 8300 5 gt Exec Default mode when NNCLI is started logout to exit Privileged ERS 8300 5 privExec enable to enter EXEC from User EXEC mode disable to exit to User EXEC mode Global ERS 8300 5 config config configure to enter Configuration from Privileged EXEC mode exit to exit to Privileged EXEC mode Interface ERS 8300 5 config if config if interface to Configuration enter from Global Configuration mode
12. econds DANGER Due to high energy hazards of working with components of greater than 240 VA only qualified service personnel are permitted to install and replace Ethernet Routing Switch 8300 components To install an AC power supply Step Action 1 Remove the filler panel from the power bay if necessary For instructions see Removing and installing a power filler panel page 17 Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Installing the AC power supply 19 CAUTION Save the power filler panel in case you need to operate the 8300 Series chassis with a power supply removed 2 If you are replacing a failed power supply then remove the failed supply For instructions see Removing the AC power supply page 20 3 Grasp the handle of the new power supply 4 Push the power supply firmly into the bay S958PA 6 Connect the power cord to the power supply and to an AC power outlet that is on a circuit with no other equipment connected to it Connect each power supply in the chassis to a separate AC circuit Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 20 Power supply installation S960PA 7 Turn on the power switch The power supply LED on the power supply sho
13. inal 200 240 VAC input power voltage source Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 26 Appendix Electrical specifications for the AC power supply Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Nortel Ethernet Routing Switch 8300 Installation AC Power Supply Copyright 2007 Nortel Networks All Rights Reserved Publication NN46200 301 Document status Standard Document version 03 01 Document date 27 August 2007 Sourced in Canada and the United States of America To provide feedback or report a problem in this document go to www nortel com documentfeedback Nortel the Nortel logo and the Globemark are trademarks of Nortel Networks Adobe and Acrobat Reader are trademarks of Adobe Systems Incorporated Microsoft Windows and Windows NT are trademarks of Microsoft Corporation All other trademarks are the property of their respective owners NORTEL
14. ion about installing power supplies Navigation e Power supplies page 13 e Removing and installing a power filler panel page 17 e Installing the AC power supply page 18 e Removing the AC power supply page 20 Power supplies The Ethernet Routing Switch 8306 and 8310 chassis have three bays for power supplies Use the AC power supply for AC input power The following figure shows an Ethernet Routing Switch 8301AC power supply The nominal input voltage range for the 8301AC power supply is 100 120 VAC and 200 240VAC however the output power is limited to 1140 W maximum at 100 120 VAC nominal input voltage conditions To obtain full output power 1770 W you must connect the 8301AC power supply to a 200 240 VAC nominal input voltage source Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 14 Power supply installation o _ lt SLL ee Figure 1 8301AC power supply 10221FA Figure 2 8302AC power supply page 14 shows an Ethernet Routing Switch 8302AC power supply The nominal input voltage range for the 8302AC power supply is 100 120 VAC and 200 240VAC however the output power is limited to 850 W maximum at 100 120 VAC nominal input voltage conditions To obtain full output power 1400W you must connect the 8302AC power supply to a 200 240 VAC nominal input voltage source Figure 2 8302AC power
15. nfiguration e Interface configuration Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 8 Preface SC SSCs Each mode provides a specific set of commands The command set of a higher privilege mode is a superset of a lower privilege mode That is all lower privilege mode commands are accessible when using a higher privilege mode The command modes are as follows e User EXEC mode This is the initial mode of access By default the User Access Verification Password for this mode is empty and password checking is disabled The password can be changed and password checking enabled by the system administrator in Global configuration mode Once the password is changed it is activated immediately e Privileged EXEC mode This mode is accessed from the User EXEC mode When accessing this mode you are prompted to provide a login name and password The login name and password combination determines your access level in the Privileged EXEC mode and other higher modes e Global configuration mode This mode allows you to make changes to the running configuration If the configuration is saved these settings survive reboots of the switch e Interface configuration mode This mode allows you to modify either a logical interface such as a VLAN or a physical interface such as a port slot From either the Global configuration mod
16. ower 100 120 VAC or 200 240 VAC and the number of power supplies For the input power specifications for each of the modules see Nortel Ethernet Routing Switch 8300 Installation Modules NN46200 305 Table 3 Recommended 8301AC 8302AC power supplies Number of power supplies Number of Redundant Chassis modules Required configuration 8306 1 6 1 2 8310 1 6 1 2 7 10 2 3 Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 16 Power supply installation I SLL ee Note the following information Table 4 If a power supply fails when you have a redundant power supply installed the Ethernet Routing Switch 8300 continues to operate with no interruption of service The chassis will continue to supply the same module and PoE output power with the remaining power supplies A trap and syslog message will indicate that the configuration is non redundant Nortel recommends that you operate the Ethernet Routing Switch 8300 in a redundant configuration at all times to ensure maximum network up time Nortel recommends that you install each power supply on its own dedicated branch circuit When you plug the power cord for each power supply into a separate AC circuit the redundant power supply also provides protection against the disconnection or failure of an individual branch circuit or power supply failure If you have installed
17. rtel Ethernet Routing Switch 8300 is a flexible and multifunctional Layer 2 Layer 3 switch that supports diverse network architectures and protocols The Ethernet Routing Switch 8300 provides security and control features such as Extensible Authentication Protocol over LAN EAPOL Simple Network Management Protocol Version 3 SNMP3 and Secure Shell SSH The Ethernet Routing Switch 8300 provides quality of service QoS for a high number of attached devices and supports future network requirements for QoS for critical applications such as Voice over IP VoIP This guide is intended for qualified service personnel who need to add or replace an AC power supply in an Ethernet Routing Switch 8300 Series chassis A qualified service person should have appropriate technical training and experience and be aware of the hazards involved in installing and replacing customer replaceable units This guide provides information about the AC power supply used in the Ethernet Routing Switch 8300 Series chassis and instructions for adding and replacing an AC power supply in the following Ethernet Routing Switch 8300 Series chassis models e Ethernet Routing Switch 8306 chassis e Ethernet Routing Switch 8310 chassis Command line interfaces See the following sections for information about the CLI and the NNCLI NNCLI command modes The NNCLI has four major command modes listed in order of increasing privileges e User EXEC e Privileged EXEC e Global co
18. the NNCLI 9 Returning to the CLI 10 Text conventions 10 Hard copy technical manuals 11 How to get help 12 Power supply installation 13 Navigation 13 Power supplies 13 Removing and installing a power filler panel 17 Installing the AC power supply 18 Removing the AC power supply 20 Electrical specifications for the AC power supply 23 Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 4 Contents Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks New in this release See the following sections for details about what s new in Nortel Ethernet Routing Switch 8300 Installation MAC Addresses NN46200 600 for Release 4 0 e Features page 5 e Other changes page 5 Features There are no new feature related changes for this document release Other changes This document is reformatted to comply with Nortel Customer Documentation Standards Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 6 New in this release I SC SSCs Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Preface The No
19. this document without notice Nortel Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Portions of the code in this software product may be Copyright 1988 Regents of the University of California All rights reserved Redistribution and use in source and binary forms of such portions are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation advertising materials and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California Berkeley The name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE In addition the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure that may incorporate by reference certain limitations and notices imposed by third parties Contents New in this release 5 Features 5 Other changes 5 Preface 7 Command line interfaces 7 NNCLI command modes 7 Accessing
20. uld light green BIGI FA End Removing the AC power supply DANGER Due to high energy hazards of working with components of greater than 240 VA only qualified service personnel are permitted to install and replace Ethernet Routing Switch 8300 components You can remove a redundant power supply without affecting the operation of the Ethernet Routing Switch 8300 Series switch When you remove a power supply the LED on the power supply turns off and the Ethernet Routing Switch 8300 Series Chassis automatically redistributes the load to the remaining power supplies Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Removing the AC power supply 21 You should replace a failed power supply as soon as possible to restore high availability operation CAUTION To maintain proper cooling never operate the Ethernet Routing Switch 8300 Series chassis with an empty power supply bay If you are replacing a failed power supply and you do not have a power filler panel leave the failed power supply installed until a replacement power supply is available To remove an AC power supply Step Action 1 Turn off the power switch on the power supply that you are replacing 2 Disconnect the power cord from the power outlet and from the power supply 8962FA 3 Loosen the two retaining scre
21. ws on the power supply Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks 22 Power supply installation 8963FA 4 Lift the extractor lever to disconnect the power supply from the backplane connector 9072FA 5 Pull the power supply out of the chassis 6 Install a new power supply see Installing the AC power supply page 18 or install a power filler panel see Removing and installing a power filler panel page 17 End Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 03 01 Standard 4 0 27 August 2007 Copyright 2007 Nortel Networks Appendix Electrical specifications for the AC power supply This appendix lists the electrical specifications for the Ethernet Routing Switch 8301AC power supply Refer to your chassis installation manual for system power specifications The following table list the power specifications for the Ethernet Routing Switch 8301AC power supply Table 5 Ethernet Routing Switch 8301AC power specifications AC Input Power Ratings Input voltage range nominal 100 120 VAC 200 240 VAC Input current nominal 16A 12A Frequency range nominal 50 60 Hz 50 60 Hz Input VA 1600 VA 2234 VA Input power consumption 1584 W 2212 W Heat dissipation 1515 BTU hr 1508 BTU hr thermal output Hold up time 20 ms