NewAir AC12000H User's Manual

image

Contents

1. Insert the filter set into the unit 6 FIG 11 OPERATING INSTRUCTIONS Control Panel 22 21 28 5 LP DANG ner eed 20 20 TIMER AL UP pe 10 SLEEP J O DOWN 41 ION lovor O 42 47 o COMP WATER FULL o 43 16 15 Fan speed ventilation button Timer button Display window Remote control receiver Heater indicator for AC 12000H only Mode selection button Automatic mode indicator Cooling mode indicator Fan mode indicator 0 Temperature increase button 1 Temperature decrease button T ee LO OR NO HOY A 0 Turning the Unit On and Off 12 13 14 15 16 17 18 19 20 21 22 44 Power indicator Full water tank indicator ON OFF power button Sleep mode button lonizer button Compressor indicator lonizer indicator Sleep mode indicator Timer indicator Low fan speed indicator High fan speed indicator e Press the ON OFF button The unit will automatically begin operating in cooling mode on low fan speed The default temperature is 75 F e At this time the indicator lights will show any functions that are in progress Please note that the display window will only show ambient room temperatures ranging from 32 F to 122 F e To turn the unit off press ON OFF button again Setting the Mode Function 1 Press the MODE button to select the desired mode cooling fan or heating Heating mode is o
2. 6 Replace the rubber plug and make sure it is firmly in place Rubber plug 7 Turn the unit back on The full tank indicator light should turn off WF A U j D AI tow N AN yy 5 Ey Oo o FIG 14 For Continuous Drainage e Remove the rubber plug from the drainage port and retain it for future use e Connect the drain tube to the drainage port as shown fig 17 e Connect the other end of the hose to a drain e The drain tube may be extended by adding an extension tube with a suitable connector Please Note 1 The drain must be at or below the level of the drainage port 2 The full water tank indicator light will not work when the unit is being continuously drained 3 To extend the drain tube you can connect it with another hose with an overall diameter of approximately 0 7 y Rubber plug Drain knob FIG 15 Drain tube NS gt FIG 16 Original drain tube Extended drain tube OD 0 7 FIG 17 10 For Heating Mode While using the heating function please note the following il In order to properly exhaust cool air make sure the exhaust hose and window kit are properly installed refer to page 6 for instructions Set up the air conditioner for continuous drainage using the drain tube refer to page 13 for instructions The working range for the heating function is 32 F to 68 F The unit may not provide optimal heating
3. F on the 1st hour another 1 F on the second hour and then maintain that temperature 3 In sleep mode the fan will automatically be set to low By pressing the SLEEP button again the set temperature and fan speed will revert back to previous settings The unit will shut down automatically after it has been in sleep mode for 12 hours 5 Sleep mode will not work when the unit is in fan dehumidification or auto mode It will only work in cooling or heating mode Heating Mode When the air conditioner is in heating mode ambient warm air is recycled and used to heat your immediate area The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed When in heating mode the machine can be set on HIGH or LOW speed lonizer Press IONIZER button to activate the ionizer function Error Messages If there is an error with the air conditioner the LCD screen will display E1 or E2 If either of these error messages appears please contact the manufacturer or a service center All of the above functions can be controlled with the included remote The remote requires 2 AAA batteries FIG 13 Please Note 1 To prolong the life of the compressor after turning off the unit please wait at least 3 minutes before turning it back on 2 The cooling system will turn off if the ambient temperature is lower than the set temperature However the fan will continue operating at the set lev
4. el Once the ambient temperature rises above the set temperature cooling will resume 3 The heating system will turn off if the ambient temperature is higher than the set temperature The ventilation fan will continue operating at the set level Once the ambient temperature drops below the set temperature heating will resume 4 This machine is equipped with an anti frost function When using the heating function in low temperatures the heater will occasionally stop heating in order to melt any frost that has accumulated within the air conditioner Normal operation will resume in a few moments DRAINING THE UNIT During the cooling process some water will be extracted from the air and stored within the unit s water reservoir If the water reservoir is full both the compressor and motor will stop and the unit will beep press any button to stop the beeping sound The full water tank indicator light will also start flashing To resume cooling empty the reservoir by following these steps 1 Turn off the air conditioner and unplug it from the wall socket To prevent water leakage avoid moving the unit when full 2 Place acontainer such as a small pan underneath the hole 3 Remove the rubber plug from the hole and allow the water to drain out 4 When the container is almost full replace the plug back into the hole 5 Repeat these steps until the water reservoir is completely empty
5. haust air outlet located on the back of the air conditioner 4 Attach one end of the hose adapter onto the exhaust hose 5 Attach the other end of the hose adapter to the window kit Positioning the Exhaust Hose e Insert the exhaust hose into the back of the unit and tighten it into place FIG 7 e Avoid kinks and bends in the exhaust hose This can cause moist air to accumulate resulting in overheating and unexpected shut offs e The exhaust hose may be extended from 12 inches 300 mm to 59 inches 1500 mm but for maximum cooling efficiency use the shortest hose length possible FIG 8 FIG 9 WARNING The included exhaust hose is specifically designed to fit the specifications of this unit Do not extend it with your own hose as this can cause the air conditioner to FIG 10 malfunction k0045 Installing the Activated Carbon Filter ds Remove the filter frame from the unit Separate the filter from the filter frame 2 Remove the activated carbon filter from its plastic bag 3 Insert the activated carbon filter into the filter frame 4 Reattach the filter onto the filter frame 5
6. iest parts of the day while the air conditioner is in operation Frequently clean the portable air conditioner s filters Once the room or area has reached your desired comfort level be sure to reduce the unit s temperature and ventilation settings VE j Siig AU PA Mh u FIG 1 FIG 2 FIG 4 k0045 PARTS LIST Front Control panel Louvers Carrying handle Casters PON Accessories 10 Exhaust hose 11 Hose adaptor goes over the hose and into the window kit 12 Extendable window kit 13 Activated carbon filter 14 Hose for continuous drainage 15 Remote control Back oS 5 Air filter 6 Air inlet 7 Cord storage 8 Exhaust air outlet 9 Rubber plug drainage point GA 0 Ce yA yo ES CD INSTALLATION INSTRUCTIONS Installing the Exhaust Hose and Window Kit Wall or Window Window Kit Adapter OI gt 14 gt FIG ae FIG 6 1 Open the window and insert the window kit into the open gap 2 Close the window until the window kit is held securely This technique may also be used for sash windows 3 Fit the exhaust hose into the ex
7. if used in temperatures outside this range 2 11 MAINTENANCE INSTRUCTIONS Always unplug the air conditioner from the power supply before cleaning To maximize the efficiency of the air conditioner regularly clean the unit Cleaning the Housing e Use a soft damp cloth to wipe the body clean e Never use harsh chemicals gasoline detergents chemically treated cloths or other cleansing solutions These all could possibly hurt the cabinet Cleaning the Filter e Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters Rinse the filter under running water no warmer than 104 F e Thoroughly dry the filter before replacing it back into the unit End of Season Storage e Completely drain any condensed water from the unit e Setthe air conditioner on fan mode ventilation only for a few hours to dry the inside of the unit e Clean or change the filter e Unplug and wrap the power cord around the cord wrap as shown fig 20 e Place the unit back in its original carton and store it in a clean dry area FIG 19 12 TROUBLESHOOTING The air conditioner does not work The unit does not produce adequate cooling The unit is noisy The compressor does not work Is the air conditioner plugged in Is the power outlet functioning cor
8. k0045 NewAir AC 12000E AC 12000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE IT ON A FLAT LEVEL SURFACE AT LEAST 14 INCHES AWAY FROM ANY OTHER OBJ ECTS Fig 1 4 DO NOT PLACE OBJ ECTS ON THE UNIT AND DO NOT COVER OR OBSTRUCT THE INLET OR OUTLET GRILLS FIG 2 CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN THE UNIT ISIN USE THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS INCLUDING CHILDREN WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING ITS USE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE ELECTRICAL SAFETY THIS APPLIANCE IS FOR INDOOR USE ONLY ALWAYS TURN OFF THE UNIT AND UNPLUG IT WHEN NOT IN USE DO NOT USE THIS UNIT IN EXCESSIVELY HUMID OR WET ENVIRONMENTS FIG 3 DO NOT PULL OR PLACE STRAIN ON THE POWER CORD WHEN MOVING THE APPLIANCE IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SPECIALIZED TECHNICIAN AUTHORIZED BY THE MANUFACTURER IN ORDER TO PREVENT FIRE FOR MAXIMUM EFFICENCY Make sure doors and windows are closed while the portable air conditioner is in use Also keep curtains and blinds closed during the sunn
9. nly available on the AC 12000H 2 The selected mode s indicator light will turn on Setting the Temperature 1 Press the Up or Down button to change the set temperature 2 The display window will indicate the set temperature If no temperature is set the display will show the ambient room temperature 3 Please note that the preset temperature for cooling is 75 F for cooling and 68 F for heating Setting the Fan Ventilation Speed Press the SPEED button to select the desired fan speed high or low The appropriate indicator light high or low will turn on accordingly Setting the Timer 1 Press TIMER button to set the desired number of operating hours from 1 to 24 hours When the set time has been reached the machine will turn off automatically The display window will show the number of hours being set as you press the TIMER button If the TIMER is not set the unit will work continuously 2 By pressing the timer but without selecting any other modes or settings you can set the number of hours to be delayed before the unit turns on For example if you set the timer to 2 the unit will automatically turn on after 2 hours Sleep Mode 1 When in cooling mode press the SLEEP button The set temperature will increase1 F on the first hour another 1 F on the second hour and then maintain that temperature 2 When in heating mode press the SLEEP button The set temperature will decrease 1
10. odel number AC 12000H 2 The data marked with may vary for technical reasons for more accurate data please refer to the rating label found on the back of the unit 3 Measuring condition for the above specifications Cooling DB 95 F 35 C WB 82 94 F 28 3 C Heating DB 68 F 20 C WB 59 F 15 C D B dry bulb temperature room temperature W B wet bulb temperature relati ve humidity N Reset Button 3 Y Test Button Green Light If you plug in the Air Conditioner and there is no green light on the plug press the reset button on the LCDI plug The green light should be lit indicating that the air conditioner is getting power from the electrical outlet If the plug continues to trip which is a USA national safety standard feature and the green light goes off the cord may be damaged preventing you from resetting the unit For your safety contact a licensed electrician 14
11. rectly Is the full water tank indicator light flashing Is the ambient room temperature lower than the set temperature Is the unit placed in direct sunlight If so close any curtains or move the unit to a more shaded area Are too many windows or doors open Are there too many people in the room Are there additional heat sources in the room Is the filter dusty or dirty Is the air inlet or air outlet blocked Is the ambient room temperature lower than the set temperature Is the machine positioned unevenly Make sure the air conditioner is positioned on an even solid surface Is the compressor s overheat protection function activated If so wait for the temperature to drop and then turn on the unit again yx Never try to repair or dismantle the unit yourself Unauthorized repairs can void your warranty and endanger the user 13 TECHNICAL SPECIFICATIONS Model Number AC 12000E AC 12000H Power Consumption for 1166W 11A 1166W 11A Cooling Power Consumption for N A 1054W 10 1A Heating Air Volume max speed 440m h 440m h Dehumidification Capacity 1 2L hour 1 2L hour Voltage Frequency 115V 60Hz Compressor Type Rotary Refrigerant Type R 410A Number of Fan Speeds 2 Timer 1 24 hours Exhaust Pipe Dimensions 5 X 59 06 Net Weight 63 9 Ibs 63 9 Ibs Dimensions 14 4 x 15 6 x 29 3 Notes 1 Heating function is only for m