Home

NEC Express5800/GT110e-S Configuration Guide

image

Contents

1. Drive SAS 300GB HDD N8150 301 3 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All drives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 18 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 5 Up to three Drives with RAID 5 Controller with 512 MB Cache Category Product Name Description Part Number Sto
2. Plug 2 5 inch SATA HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 500GB 7 2K Hot Plug 2 5 inch SATA HDD 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 1TB 7 2K Hot Plug 2 5 inch SATA HDD 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm 100GB Hot Plug 2 5 inch SAS SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD 1x 400 GB SAS SSD 2 5 inch 6Gb s Part Number N8103 128 N8103 141 R410 180 00 Standard N8150 301 N8150 322 N8150 304 N8150 332 N8150 302 N8150 303 N8150 331 N8150 356 N8150 357 N8150 358 N8150 709 N8150 710 N8150 711 N8150 712 e Alldrives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 17 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 4 Up to three Drives with RAID 0 1 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller RAID Controller 512MB RAID 0 1 N8103 149 Required LSI MegaRAID SAS 9267 8i RAID 0 1 512 MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays
3. SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rom SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All hard drives within a RAID array should be of the same capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 23 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 10 Up to five Drives with RAID 5 6 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller RAID Controller 512MB RAID 0 1 N8103 150 Required LSI MegaRAID SAS 9267 8i RAID 0 1 5 6 512 MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cag
4. eeeeeeeeeeeeeeen eene eenn enne nnne nnnm nannten antenne rantes rante nnns 12 4 RAID Gohflguf ation etat ote teet taedet e vadat c Erde pda 12 4 2 S 5 inch Drive Configuration nennen tnn enne nsen ten nnns 14 43 2 5 inch Drive Configuration ener entrent nennen nnne entere 16 5 Internal Optical Drive rcc reeecon rccte rtr tcer noci stie ca eon em xe EEEEEEEEAEE SC 27 6 Internal Tape RDX drives eeeseeesseeeeee seinen eene nennen nnn nnne nnn nnmnnn nnmnnn nnmnnn nnns 27 6 1 Tape RDX Drive Selection esses ener entren tenen nes 27 6 2 Tape RDX CGonftouraiion enne nnns en nennen sinn sn tenen nes 27 rM eem EE 29 7 1 Network Interface Controller sees nennen enne nnns 29 7 2 Serial Port Adapter ede ere ir ee etas Pene t etd eed vent Pose ded des s da uen 29 8 Other Add in Components m2 mm222eammnaannaananenanmnannmamanmnanmnenanmanananamanentnentnaranamenannenten 30 8 1 Internal Flash Memory eeesseseessessseseeeseeenee esent nnne en nennt innert essen 30 8 2 Flash EDD use eine beide te Bee eter rie edet et diesels 30 BiB Input Devices oe Roe e HE iet odere ede E 30 9 Ee lee EC 31 9 1 Server Management Lvense eene nnne nennen sns nnne enne 31 9 2 Dust Insect Proof ky 31 9 3 Medium and Cartridge ccccccceccececseceeeseneeeeesseeeeeeseeeeeeeseeeeesseeeseesseeeaeeeseeseeesssnsaeesseesaees 31
5. 0 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e Alldrives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 19 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 6 Up to three Drives with RAID 5 Controller with 1 GB Cache Battery Category Product Name Description Part Number Storage Coniroller RAID Controller 1GB RAIDO 1 5 6 N8103 151 Required LSI MegaRAID SAS 9267 8i RAID 0 1 5 1 GB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i SSD Caching MegaRAID CacheCade N8103 156 Recommended for LSI MegaRAID SAS 9267 8i NOTE SSD used for cache is required The SSD capacity which can be used as read cache is up to 512 GB Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Drive SAS 300GB HDD N8150 301 3 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rom 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 i
6. 128 MB Cache Category Product Name Description Part Number Storage Coniroller RAID Controller 128MB RAID 0 1 N8103 128 Required Promise SuperTrak TX8760T 128 RAID 0 1 10 128MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 3Gb s RAID BBU RAID Battery Backup Unit N8103 141 Recommended for Promise SuperTrak TX8760T Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Optional HDD Cage Additional 2 5 Inch HDD Cage N8154 37 Required 2x 2 5 inch hot plug hard drive bays Including 1x mini SAS to 1x mini SAS cable Drive SAS 300GB HDD N8150 301 5 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 S
7. 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm NOTE e Embedded SATA RAID controller is supported only on Windows operating systems An optional RAID controller is required to configure RAID array for other operating systems e All hard drives within a RAID array should be of the same capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 16 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Up to three Drives with RAID 0 1 Controller with 128 MB Cache 4 3 3 Category Storage Coniroller Required RAID BBU Recommended Cable Required Drive Cage Drive SAS 3 slots HDD available SATA HDD SAS SSD NOTE Product Name Description RAID Controller 128MB RAID 0 1 Promise SuperTrak TX8760T 128 RAID 0 1 10 128MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 3Gb s RAID Battery Backup Unit for Promise SuperTrak TX8760T Internal SAS Cable mini SAS to mini SAS 2 5 inch Drive Cage 3 x 2 5 inch hot plug hard drive bays 300GB HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 450GB HDD 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 250GB 7 2K Hot
8. 3 5 inch SATA HDD N8150 359 2 slots available 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm 1TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 360 1x1 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 2TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 361 1 x 2 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 3TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 362 1 x 3TB SATA HDD 3 5 inch 6Gb s 7 200 rpm NOTE e Allhard drives within a RAID array should be of the same capacity 4 2 4 RAID 0 1 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller RAID Controller 512MB RAID 0 1 N8103 149 Required LSI MegaRAID SAS 9267 8i RAID 0 1 512 MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i Cable Internal SATA Cable K410 253 00 Required mini SAS to 2x SATA Drive Cage 3 5 inch Drive Cage Standard 2 x 3 5 inch non hot plug fixed hard drive bays Drive 500GB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 359 2 slots available 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm 1TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 360 1 x 1 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 2TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 361 1 x 2 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 3TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 362 NOTE 1 x 3TB SATA HDD 3 5 inch 6Gb s 7 200 rpm e Al hard drives within a RAID array should be of the same capacity NEC Corporation Re
9. B2 0 2 front 4 rear 2 internal 2 1000BASE T LAN connector RJ 45 2 rear 1 100BASE TX LAN connector for Management RJ 45 1 rear EXPRESSSCOPE Engine 3 Standard 1 x 250 Watt 80 PLUSO Sliver certified non Hot plug PSU 100 240 VAC 10 50 60 Hz 3 Hz 77 VA 74 Watt 79 VA 76 Watt 166 VA 164 Watt 169 VA 166 Watt 29 5 dB 37 6 dB 37 3 dB 39 8 dB 93 0 x 386 5 x 363 0 mm 3 6 x 15 2 x 14 3 in 4U 9 kg 12 kg 19 84 Ibs 26 46 Ibs NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Model Temperature Relative Humidity non condensing Regulatory and Safety Operating Systems and Virtualization Software media bay a 5 o N by the operating environment GT110e S Operating 10 to 40 C 50 to 104 F 20 to 80 Non Operating 10 to 55 C 14 to 131 F 20 to 80 FCC CE BSMI CCC UL CB ROHS WEEE Microsoft Windows Server 2003 R2 Standard Edition SP2 or later Microsoft Windows Server 2003 R2 Enterprise Edition SP2 or later Microsoft Windows Server 2008 Standard Microsoft Windows Server 2008 Standard x64 Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2008 Enterprise x64 Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise Red Hat Enterprise Linux 5 8 or later Red Hat Enterprise Linux 5 8 or later EM64T 3 Red Hat Enterp
10. CH CUI based screen OS console aid GUI based screen OS console Remote control Remote reset power on off dump Y via LAN Remote Power Capping Y BIOS BMC FW update Y Remote BIOS setup partial configuration only Y OS shutdown y Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Y Remote control via Web browser multi user login Y at the same time Scheduling without UPS v Maintenance EXPRESSSCOPE Profile key y Backup restore BIOS BMC setup information Others Set automatic IP address via DNS DHCP Y LDAP Active Directory verification user control Y Clock synchronization of main unit and the RTC Y Access log collection Y Industry IPMI support 2 0 Standard The feature is not supported on non hot plug 3 5 inch drive The standard serial port is not available for the feature The feature is not supported on VMware systems Monitoring boot screens is not supported on VMware systems In VMware systems only the direct console user interface is supported a F oO N With Remote KVM and Media License kit Y Y Y SIS RR NEN NEN NEN NNN SIS MY SESE SIS o NEC Corporation Revision 2 0 November 7 2012 32 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model OS Support Matrix for PCI Cards and Embedded Controllers a6 SR FF TTP 23 s EE ee ee a i er Part 2 a o Number Product Name eot 5 Embedded SATA non RAID Controller VY v wv wv wv wv wv wv wv
11. Empowered by Innovation A EC NEC Express5800 GT110e S Configuration Guide Air cooling model Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server November 7 2012 Revision 2 0 NEC Corporation CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Contents TECHNICAL SPECIFICATION 2 5 eoa inan tnn annu meu nuin n nuu meu nuu mun n 3 Key FO atures es ces 3 I erect T 3 EXTERNAL eee en eee EIE EI MU MI DI EUM MI MM eee 7 diei e 7 Rear VICWS e 7 IIurapninnrduumme 8 CONFIGURATION DIAGRAM ciccssisisscnsscastsansstedssatctncsannntadsnsseaninacdndncntesstacsanesiaduancaducenades 9 Expansion SOUS ee 10 SERVER CONFIGURATION ME 11 T Base Models ie eege 11 MR Oe e 11 3 Memoly aii ee ei ieee ee ie enh 11 Maximum Available Memory ssssssseseseseeeenenneeenen nene nnne enne inen nnnn iaai nennen enne en 12 4 Internal Hard Disk Drives
12. I Slots Low Profile L Dump NMI Switch AC Inlet mo o w USB Connectors NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Dimensions mm Tower installation 10 386 5 361 5 25 e O 363 368 Lay flat installation RULES NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Configuration Diagram 3 5 inch Drive model CHASSIS CHASSIS CHASSIS FRONT REAR INSIDE 3 5 inch Drive Cage 4 DIMM Optical Drive PCle 2 0 PCle 3 0 or 2 0 pcr Cooling FAN BBU slot Legend E Minimum requirement components Standard components Q o a e T gt 9605 SAUQ uour ee 2 5 inch Drive model CHASSIS CHASSIS REAR INSIDE CHASSIS FRONT 2 5 inch Drive Cage Cooling FAN Optical Drive NVJ 5uljoo5 PCle 2 0 PCle 3 0 or 2 0 Cooling FAN BBU slot Legend E Minimum requirement components Standard components v o NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Expansion Slots CO LUN Legend 1 PCle 2 0 x4 x8 connector Low Profile up to 167 6mm length 2 PCle 2 0 x4 x8 connector Low Profile up to 167 6mm length 3 PCle 3 0 or 2 0 x16 x16 connector Low Profi
13. Linux 6 x86 64 2 TB 32 GB VMware ESXi 5 0 2TB 32 GB VMware ESXi 5 1 Up to 1 TB of the main memory is available to each virtual machine 4 internal Hard Disk Drives 4 1 RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration 4 1 1 3 5 inch Drive Available Interface Non RAID Refer to 4 2 1 SATA Embedded SATA RAID Controller Controller NOTE e Embedded SATA RAID controller is supported only on Windows operating systems An optional RAID controller is required to configure RAID array for other operating systems e All hard drives within a RAID array should be of the same capacity NEC Corporation Revision 2 0 November 7 2012 12 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 1 2 2 5 inch Drive Up to three drives Available Interface Non RAID Refer to 4 3 1 SATA Embedded SATA RAID Controller Refer to 4 3 2 SATA RAID 0 1 Optional RAID 128 MB Cache Refer to 4 3 3 SAS SATA Controller 512 MB Cache Refer to 4 3 4 SAS SATA 512 MB Cache Refer to 4 3 5 SAS SATA 1GB Cache Refer to 4 3 6 SAS SATA Battery Refer to 4 3 7 SAS SATA 1GB Cache CacheVault Up to five drives RAID 0 1 Available Interface SAS SATA 128MB Cache Refer to 4 3 8 SAS SATA Battery SAS SATA 1GB Cache CacheVault NOTE Embedded SATA RAID controller
14. November 7 2012 24 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 11 Up to five Drives with RAID 5 6 Controller with 1 GB Cache Battery Category Product Name Description Part Number Storage Coniroller RAID Controller 1GB RAIDO 1 5 6 N8103 151 Required LSI MegaRAID SAS 9267 8i RAID 0 1 5 6 1 GB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i SSD Caching MegaRAID CacheCade N8103 156 Recommended for LSI MegaRAID SAS 9267 8i NOTE SSD used for cache is required The SSD capacity which can be used as read cache is up to 512 GB Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Optional HDD Cage Additional 2 5 Inch HDD Cage N8154 37 Required 2x 2 5 inch hot plug hard drive bays Including 1x mini SAS to 1x mini SAS cable Drive SAS 300GB HDD N8150 301 5 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 r
15. O Agent and Universal RAID Utility Performance of the Test and Diagnosis Tool 8 2 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive Product Name Description Flash FDD USB flash emulating USB floppy disk Native capacity 1 44 MB NOTE e Upto one derive can be connected 8 3 Input Devices Product Name Description Keyboard and Mouse Pack US 1 x 104 keys White USB keyboard 1 x USB White Optical Wheel Mouse Part Number N8115 05 Part Number N8160 86 Part Number Standard NEC Corporation Revision 2 0 November 7 2012 30 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 9 Add on Components 9 1 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard Refer to Server Management for the standard management features For more extensive remote KVM and remote media features choose the following kit Product Name Description Part Number Remote KVM and Media License Kit N8115 04 License for one server Remote KVM and remote media are enabled regardless of OS status Remote KVM A Displays a graphics console on the web browser of the remote terminal PC server Controls keyboard and mouse via the remote terminals web browser Remote media Enables the user to use the CD DVD FD Flash memory of the remote terminals PC server as if accessing the local drives NOTE e Remote KVM and remote media
16. REFERENCES sissende 32 Server Manageme see 32 OS Support Matrix for PCI Cards and Embedded Controllers esses 33 Supported PCI cards and Installable Slots eese seen eene nennen nnne nennen nnn 33 Copyright Notice and Liability Disclaimer eseseeeeeeeeeeeeeeee sienne nennen nennen nnnm nnne natn 34 REVISION M zuenod 35 NEC Corporation Revision 2 0 November 7 2012 2 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Technical Specification Key Features e Ultra compact form of 93mm in width 13 liters in volume e Upto 32 GB of high speed DDR3 1600 memory e Full manageability by integrated EXPRESSSCOPE Engine 3 e Function in maximum 40 C 104 F ambient temperature Specification 3 5 inch Drive Model Model Part Number Processor Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Type Standard Capacity Maximum Capacity Internal Storage Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Optical Disk Drive 3 5 inch Media Bays Disk Drive Bays Expansion Slots Video Controller VRAM Resolution Color Interfaces Server Management System Fan Power Supply GT110e S N8100 1891F Intel amp Pentium amp processor Intel Xeon pro
17. SD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e Alldrives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 22 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 9 Up to five Drives with RAID 0 1 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller RAID Controller 512MB RAID 0 1 N8103 149 Required LSI MegaRAID SAS 9267 8i RAID 0 1 512 MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Optional HDD Cage Additional 2 5 Inch HDD Cage N8154 37 Required 2x 2 5 inch hot plug hard drive bays Including 1x mini SAS to 1x mini SAS cable Drive SAS 300GB HDD N8150 301 5 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB
18. available DDS3 DDS4 DAT72 Native capacity 36 GB NOTE DDS1 DDS2 format are not supported NEC Corporation Revision 2 0 November 7 2012 27 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 6 2 20 RDX Category Controller Cable Required Drive 1 bay available Product Name Description Internal USB Controller 1 x USB port or 1 x pin header for front panel USB Internal USB Cable 1x Internal USB to 1x USB device NOTE The cable is required to install USB tape drive only Internal USB Cable 1x pin header for front panel USB to 1x USB device and 1x front panel USB port NOTE The cable is required to install internal flash memory and USB tape drive A USB tape drive occupies one front USB port Internal RDX USB Part Number Standard K410 255 00 K410 245 00 N8151 105 NEC Corporation Revision 2 0 November 7 2012 28 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 7 PCI Card 7 1 Network Interface Controller Category Product Name Description Part Number 1GbE 1000BASE T Adapter N8104 138 Broadcom BCM5718 Gigabit Ethernet Controller PCle 2 0 x1 FP FH Dual Port 1000BASE T Adapter N8104 132 Broadcom BCM5718 Gigabit Ethernet Controller PCle 2 0 x1 NIC Teaming feature NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations Windows supports BASP Broadcom Advanced Server Progra
19. ber 7 2012 26 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 5 Internal Optical Drive Available Bays 1 Product Name Description Part Number Slim DVD ROM drive Standard Internal DVD Super Multi Drive N8151 104F Slim DVD Super Multi drive not including vvriting softvvare NOTE e To install internal DVD Super Multi drive the standard DVD ROM drive needs to be removed 6 Internal Tape RDX drives 6 1 Tape RDX Drive Selection Refer to the section in accordance with your type of tape drives e DAT Refer to 6 2 1 e RDX Refer to 6 2 2 NOTE e Notape drive can be installed if you install optional 2 5 inch Drive Cage e Tape devices cannot be directly connected to VMware systems For VMware systems it is recommended to connect and configure an additional backup server via network 6 2 Tape RDX Configuration 6 2 1 DAT USB Category Product Name Description Part Number Controller Internal USB Controller Standard 1 x USB port or 1 x pin header for front panel USB Cable Internal USB Cable K410 255 00 Required 1x Internal USB to 1x USB device NOTE The cable is required to install USB tape drive only Internal USB Cable K410 245 00 1x pin header for front panel USB to 1x USB device and 1x front panel USB port NOTE The cable is required to install internal flash memory and USB tape drive A USB tape drive occupies one front USB port Drive Internal DAT USB N8151 69 1 bay
20. cessor G640 E3 1220 v2 2 80 GHz 3 10 GHz 1 3 MB 8 MB 2C 2T 4C 4T Intel C204 Chipset DDR3 1600 ECC Unbuffered DIMM 0 GB 32 GB 4 x 8 GB 0 GB 6 TB 2x 3 TB SATA 6Gb s Integrated SATA RAID 0 1 DVD ROM 1 2 Total 4 slots available 1 PCle 3 0 x16 x16 connector 2 PCle 2 0 x4 x8 connector 1 32 bit 33 MHz PCI Integrated in Server Management Controller 32MB 1280 x 1024 16 7M 1 VGA 15 pin mini D sub 1 rear 1 to 2 Serial 9 pin mini D sub RS232 C 1 to 2 rear 8 USB2 0 2 front 4 rear 2 internal 2 1000BASE T LAN connector RJ 45 2 rear 1 100BASE TX LAN connector for Management RJ 45 1 rear EXPRESSSCOPE Engine 3 Standard 1 x 250 Watt 80 PLUSO Sliver certified non Hot plug PSU 100 240 VAC 10 50 60 Hz 3 Hz NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Model Power Max Config Idling Consumption Max Config Operating Acoustic Noise Minimum Config Sound Pressure Maximum Config Level Dimensions WxDxH Weight Minimum Maximum Temperature Relative Humidity non condensing Regulatory and Safety Operating Systems and Virtualization Software B OO N a GT110e S 70 VA 65 Watt 73 VA 69 Watt 157 VA 151 Watt 158 VA 153 Watt 29 1 dB 36 8 dB 30 9 dB 37 2 dB 93 0 x 386 5 x 363 0 mm 3 6 x 15 2 x 14 3 in 4U 9 kg 12 kg 19 84 Ibs 26 46 Ibs Operating 10
21. e 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Optional HDD Cage Additional 2 5 Inch HDD Cage N8154 37 Required 2x 2 5 inch hot plug hard drive bays Including 1x mini SAS to 1x mini SAS cable Drive SAS 300GB HDD N8150 301 5 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All drives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0
22. features are not available for virtual machines 9 2 Dust Insect Proof Kit The server supports the dust resistant feature Choose the following kit to install the system in dusty places Category Product Name Description Part Number Front Bezel Dust Proof Bezel with Sensor N8146 35 Including 1 set of filter replacement sensors 1 set of dust proof filters Filter Dust proof filter 5 pcs N8147 22 For N8146 35 Dust Proof filter Removal capacity of particles Up to 1 um sized 9 3 Medium and Cartridge Category Product Name Drive supported Part Number RDX RDX Cartridge 320GB N8151 105 N8152 26 RDX Cartridge 500GB N8151 105 N8152 27 RDX Cartridge 1TB N8151 105 N8152 33 DAT DAT72 36GB Medium 5 pack N8151 69 N8152 08 NEC Corporation Revision 2 0 November 7 2012 31 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model References Server Management The EXPRESSSCOPE Engine 3 integrated into the server provides superior remote control and system management features listed in the table below Standard Hardware Temperature hard drive fan voltage povver Y monitoring consumption degeneration memory hard drive Hardware configuration information collection Y Hardware event log collection Y Boot monitoring BIOS POST stall Booting OS stall shutdown v Alerting HW error Boot error and OS panic d by SNMP E Mail Remote KVM POST BIOS setup ROM utility v via LAN Panic screen Boot screen S
23. is supported only on Windows operating systems An optional RAID controller is required to configure RAID array for other operating systems All hard drives within a RAID array should be of the same capacity and rotation speed Mixing SAS and SATA hard drives in the same system is not supported All hard drives within a system should be of the same rotation speed Hot plug insertion removal is not supported with the embedded SATA non RAID controller NEC Corporation Revision 2 0 November 7 2012 13 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 2 3 5 inch Drive Configuration 4 2 1 Embedded SATA non RAID Controller Category Product Name Description Part Number Storage Coniroller Embedded SATA Controller Standard 2x 6Gb s SATA Cable Internal SATA Cable Standard Single SATA to Single SATA 2 sets Drive Cage 3 5 inch Drive Cage Standard 2 x 3 5 inch non hot plug fixed hard drive bays Drive 500GB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 359 2 slots available 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm 1TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 360 1 x 1 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 2TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 361 1 x 2 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 4 2 2 Embedded SATA RAID Controller Category Product Name Description Part Number Storage Coniroller Embedded SATA Controller Standard 2x 6Gb s SATA RAID 0 1 capable Cable Internal SATA Cable Standa
24. l 2 5 inch Drive Model Model Part Number Processor Chipset Memory Internal Storage Expansion Slots Video Interfaces Server Management System Fan Power Supply Power Consumption Acoustical Noise Sound Pressure Level Type Clock speed Number of Processors Cache Cores and Threads Type Standard Capacity Maximum Capacity Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Optical Disk Drive 3 5 inch Media Bays Disk Drive Bays Controller VRAM Resolution Color Max Config Idling Max Config Operating Minimum Config Maximum Config Dimensions WxDxH Weight Minimum Maximum GT110e S N8100 1892F Intel Pentium processor Intel Xeon processor G640 E3 1220 v2 2 80 GHz 3 10 GHz 1 3 MB 8 MB 2C 2T 4C AT Intel C204 Chipset DDR3 1600 ECC Unbuffered DIMM 0 GB 32 GB 4 x 8 GB 0 GB SAS 4 5 TB 5 x 900 GB SATA 5 TB 5 x 1 TB SSD 500 GB 5 x 100 GB SATA 6Gb s and or 3Gb s Integrated SAS 6 Gb s Optional SATA RAID 0 1 Standard RAID 5 6 Optional SAS RAID 0 1 5 6 10 Optional Supported DVD ROM 1 3105 Total 4 slots available 1 PCle 3 0 x16 x16 connector 2 PCle 2 0 x4 x8 connector 1 32 bit 33 MHz PCI Integrated in Server Management Controller 32MB 1280 x 1024 16 7M 1 VGA 15 pin mini D sub 1 rear 1 to 2 Serial 9 pin mini D sub RS232 C 1 to 2 rear 8 US
25. le up to 167 6mm length 4 32 bit 33 MHz 5 V PCI Low Profile up to 167 6mm length NOTE e The slot 3 works at PCle 3 0 speeds on Xeon processor systems NEC Corporation Revision 2 0 November 7 2012 10 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Server Configuration 1 Base Models Product Name Description NEC Express5800 GT110e S no CPU no RAM no 3 5 inch HDD no AC cable Including Slim DVD ROM drive 3 5 inch Drive Cage 250 Watt non hot plug power supply EXPRESSBUILDER DVD NEC Express5800 GT110e S no CPU no RAM no 2 5 inch HDD no AC cable Including Slim DVD ROM drive 2 5 inch Drive Cage 250 Watt non hot plug power supply EXPRESSBUILDER DVD 2 Processor Available sockets 1 Part Number N8100 1891F N8100 1892F Category Product Name Description Part Number Processors Processor Rit 2C G640 N8101 586F Required Intel Pentium Processor G640 2 80 GHz 2C 2T 3 MB Processor Kit 4C E3 1220v2 N8101 587F Intel Xeon Processor E3 1220v2 3 10 GHz 4C 4T 8 MB NOTE e One processor kit from above must be installed 3 Memory Available slots 4 Product Name Description Part Number 2GB DDR3 1600 UNB Memory Kit N8102 501F 2GB Unbuffered ECC DIMM DDR3 1600 PC3 12800 4GB DDR3 1600 UNB Memory Kit N8102 502F 4GB Unbuffered ECC DIMM DDR3 1600 PC3 12800 8GB DDR3 1600 UNB Memory Kit N8102 503F 8GB Unbuffered ECC DIMM DDR3 1600 PC3 12800 NOTE e Mini
26. m teaming while Linux supports teaming with bonding function supported by OS Network Interface Team Operating Systems 1GbE NIC Up to four teams per one system Windows Server Embedded 1GbE NIC and N8104 138 132 Up to four ports per one team Red Hat Linux Using iSCSI See the table below for supported network interfaces and OS combinations Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC Windows Server 2008 R2 N8104 138 Windows Server 2008 R2 N8104 132 Windows Server 2008 R2 NOTE e NIC Teaming feature is not supported on iSCSI interfaces 7 2 Serial Port Adapter Product Name Description Part Number Serial Port Adapter N8117 01A Serial port fixed to PCI bracket NOTE Upto one Serial Port Adapter can be installed NEC Corporation Revision 2 0 November 7 2012 29 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 8 Other Add in Components 8 1 Internal Flash Memory Available socket 1 Product Name Description Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without DVD media NOTE Before use software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory The following operations can be performed with the flash memory Installation of Windows server with express setup Installation of Starter Pack the package of NEC qualified drivers and system setting tools Installation of NEC ESMPR
27. mum one memory kit must be installed Toinstall by double of memory kit is recommended in order to increase memory transfer speed by the dual channel symmetric configuration NEC Corporation Revision 2 0 November 7 2012 11 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB PCI resource requirements vary depending on the type and the number of PCI cards you are using Maximum memory size supported by OS Maximum available memory Microsoft Windows Server 2003 R2 Standard Edition 4GB 4 GB HW DEP enabled Microsoft Windows Server 2008 Standard App 3 5 GB HW DEP disabled Microsoft Windows Server 2003 R2 Standard x64 Edition 32 GB 32 GB Microsoft Windows Server 2008 Standard x64 Microsoft Windows Server 2008 R2 Standard x64 Microsoft Windows Server 2003 R2 Enterprise Edition 64 GB 32 GB Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2003 R2 Enterprise x64 Edition 1TB 32 GB Microsoft Windows Server 2008 Enterprise x64 2TB 32 GB Microsoft Windows Server 2008 R2 Enterprise x64 Red Hat Enterprise Linux 5 16 GB 16 GB Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 5 EM64T 1TB 32 GB Red Hat Enterprise
28. nch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All drives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 20 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 7 Up to three Drives with RAID 5 Controller with 1 GB Cache CacheVault Category Product Name Description Part Number Storage Controller RAID Controller 1GB RAID 0 1 5 6 N8103 167 Required LSI MegaRAID SAS 9270CV 8i with CV RAIDO 1 5 6 10 50 60 1GB Cache Int 8ports PCle 3 0 x8 6Gb s flash cache protection modules included SSD Caching MegaRAID CacheCade N8103 156 Recommended for LSI MegaRAID SAS 9267 8i NOTE SSD used for cache is required The SSD capacity which can be used as read cache is up to 512 GB Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Dri
29. nch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Optional HDD Cage Additional 2 5 Inch HDD Cage N8154 37 Required 2x 2 5 inch hot plug hard drive bays Including 1x mini SAS to 1x mini SAS cable Drive SAS 300GB HDD N8150 301 5 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rom 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2R Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 500GB 7 2R Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All drives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 Novem
30. ndows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for technical or editorial errors or omissions contained herein For hard drive capacity measurements 1 GB 1 billion bytes Actual formatted capacity is less The USB interface is not guaranteed to work properly for all USB devices NEC Corporation Revision 2 0 November 7 2012 34 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Revision History Revision Date 2 0 1 0 November 7 2012 July 26 2012 Description New products added 200GB SSD N8150 711 400GB SSD N8150 712 RAID Controller 1GB RAID 0 1 5 6 N8103 167 Discontinued products removed 100GB SSD N8150 707 Others VMware ESXi5 1 supported Initial release NEC Corporation Revision 2 0 November 7 2012 35
31. pm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All drives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 25 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 12 Up to five Drives with RAID 5 6 Controller with 1 GB Cache CacheVault Category Product Name Description Part Number Storage Controller RAID Controller 1GB RAID 0 1 5 6 N8103 167 Required LSI MegaRAID SAS 9270CV 8i with CV RAIDO 1 5 6 10 50 60 1GB Cache Int 8ports PCle 3 0 x8 6Gb s flash cache protection modules included SSD Caching MegaRAID CacheCade N8103 156 Recommended for LSI MegaRAID SAS 9267 8i NOTE SSD used for cache is required The SSD capacity which can be used as read cache is up to 512 GB Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 i
32. rage Controller RAID Controller 512MB RAID 0 1 N8103 150 Required LSI MegaRAID SAS 9267 8i RAID 0 1 5 512 MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 6Gb s RAID BBU RAID Battery Backup Unit N8103 155 Recommended for LSI MegaRAID SAS 9267 8i Cable Internal SAS Cable K410 180 00 Required mini SAS to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Drive SAS 300GB HDD N8150 301 3 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rom 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N815
33. rd Single SATA to Single SATA 2 sets Drive Cage 3 5 inch Drive Cage Standard 2 x 3 5 inch non hot plug fixed hard drive bays Drive 500GB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 359 2 slots available 1 x 500 GB SATA HDD 3 5 inch 6Gb s 7 200 rpm 1TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 360 1 x 1 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 2TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 361 1 x 2 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 3TB 7 2K non Hot Plug 3 5 inch SATA HDD N8150 362 1 x 3TB SATA HDD 3 5 inch 6Gb s 7 200 rpm NOTE e Embedded SATA RAID controller is supported only on Windows operating systems An optional RAID controller is required to configure RAID array for other operating systems e Al hard drives within a RAID array should be of the same capacity NEC Corporation Revision 2 0 November 7 2012 14 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 2 3 RAID 0 1 Controller with 128 MB Cache Category Product Name Description Part Number Storage Controller RAID Controller 128MB RAID 0 1 N8103 128 Required Promise SuperTrak TX8760T 128 RAID 0 1 10 128MB Int 8 PCle 2 0 x8 SAS 6Gb s SATA 3Gb s RAID BBU RAID Battery Backup Unit N8103 141 Recommended for Promise SuperTrak TX8760T Cable Internal SATA Cable K410 253 00 Required mini SAS to 2x Single SATA Drive Cage 3 5 inch Drive Cage Standard 2 x 3 5 inch non hot plug fixed hard drive bays Drive 500GB 7 2K non Hot Plug
34. rise Linux 6 2 or later Red Hat Enterprise Linux 6 2 or later EM64T S VMware ESXi 5 0 update 1 VMware ESXi 5 1 7 An optional HDD Cage is required to install more than 3 hard drives The optional HDD Cage occupies 3 5 inch Embedded SATA RAID controller is supported only on Windows operating systems The PCle x16 slot works at PCle 2 0 speeds on Pentium processor systems Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 65K colors Noise emission was measured at the operator positions in accordance with ISO 7779 The actual value may vary For Linux support contact your sales representative or go to the NEC website at http www nec com global prod express linux index html VMware ESXi is supported only on Xeon processor systems NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model External Views Front View i B C D i E l F G j H 4 L 4 ol J 3 5 inch Drive Model 2 5 inch Drive Model Legend A Vent Holes Cover F USB Connectors B Power Button G Optical Disk Drive C Power LED H 3 5 inch Media Bay D Hard Drive Activity LED L 2 5 inch Drive Bay E System Status LED J Drive Bay Cover Rey Rear Views l Leged A Serial Port Connector F Management LAN Connector VGA Connector G Data LAN Connectors BMC Reset Switch H PC
35. to 40 C 50 to 104 F 20 to 80 Non Operating 10 to 55 C 14 to 131 F 20 to 80 FCC CE BSMI CCC UL CB RoHS WEEE Microsoft Windows Server 2003 R2 Standard Edition SP2 or later Microsoft Windows Server 2003 R2 Enterprise Edition SP2 or later Microsoft Windows Server 2008 Standard Microsoft Windows Server 2008 Standard x64 Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2008 Enterprise x64 Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise Red Hat Enterprise Linux 5 8 or later Red Hat Enterprise Linux 5 8 or later EM64T Red Hat Enterprise Linux 6 2 or later Red Hat Enterprise Linux 6 2 or later EM64T VMware ESXi 5 0 update 1 VMware ESXi 5 1 Embedded SATA RAID controller is supported only on Windows operating systems The PCle x16 slot works at PCle 2 0 speeds on Pentium processor systems Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 65K colors Noise emission was measured in accordance with ISO 7779 The actual value may vary by the operating environment For Linux support contact your sales representative or go to the NEC website at http www nec com global prod express linux index html VMware ESXi is supported only on Xeon processor systems NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling mode
36. ve Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Drive SAS 300GB HDD N8150 301 3 slots HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm available 450GB HDD N8150 322 1x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 600GB HDD N8150 304 1x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 900GB HDD N8150 332 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm 73 2GB HDD N8150 302 1x 73 2 GB SAS HDD 2 5 inch 6Gb s 15 000 rom 146 5GB HDD N8150 303 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm 300GB HDD N8150 331 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x 1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm SAS 100GB Hot Plug 2 5 inch SAS SSD N8150 709 SSD 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 710 1x 400 GB SAS SSD 2 5 inch 6Gb s 200GB Hot Plug 2 5 inch SAS SSD N8150 711 1x 100 GB SAS SSD 2 5 inch 6Gb s 400GB Hot Plug 2 5 inch SAS SSD N8150 712 1x 400 GB SAS SSD 2 5 inch 6Gb s NOTE e All drives within a RAID array should be of the same type capacity and rotation speed NEC Corporation Revision 2 0 November 7 2012 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 8 Up to five Drives with RAID 0 1 Controller with
37. vision 2 0 November 7 2012 15 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model 4 3 2 5 inch Drive Configuration 4 3 1 Embedded SATA non RAID Controller Category Product Name Description Part Number Storage Coniroller Embedded SATA Controller Standard 2x 6Gb s SATA 2x 3Gb s SATA Cable Internal SATA Cable K410 241 00 Required 3x Single SATA to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Drive SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 3 slots HDD 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm available 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1 x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm 1TB 7 2K Hot Plug 2 5 inch SATA HDD N8150 358 1x1 TB SATA HDD 2 5 inch 6Gb s 7 200 rpm NOTE e Hot plug insertion removal is not supported with the embedded SATA non RAID controller 4 3 2 Embedded SATA RAID Controller Category Product Name Description Part Number Storage Coniroller Embedded SATA Controller Standard 2x 6Gb s SATA 2x 3Gb s SATA RAID 0 1 capable Cable Internal SATA Cable K410 241 00 Required 3x Single SATA to mini SAS Drive Cage 2 5 inch Drive Cage Standard 3 x 2 5 inch hot plug hard drive bays Drive SATA 250GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 356 3 slots 1x 250 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm available 500GB 7 2K Hot Plug 2 5 inch SATA HDD N8150 357 1 x 500 GB SATA HDD 2 5 inch 6Gb s 7 200 rpm
38. wv Vv Embedded SATA RAID Controller v v v wv wv a s Embedded 1GbE NIC Vo wv wv wv wv wv wv wv wv wv wv N8103 128 RAID Controller 128MB RAID 0 1 Vo wv v wv wv wv wv wv wv N8103 149 RAID Controller 512MB RAID 0 1 Vo wv v wv wv wv wv wv wv wv wv N8103 150 RAID Controller 512MB RAIDO 1 5 7 v v wv wv wv wv wv wv wv wv v N8103 151 RAID Controller 1GB RAID 0 1 5 6 Vo v v v wv wv wv wv wv wv Vv N8103 167 RAID Controller 1GB RAID 0 1 5 6 Y Vv v v v wv z N8104 138 1000BASE T Adapter 1ch vov v v v Y y N8104 132 1000BASE T Adapter 2ch Vo V v wv wv wv wv wv wv wv Supported PCI cards and Installable Slots Slots Part Number Product Name 1 2 3 4 N8103 128 RAID Controller 128MB RAID 0 1 PCle 2 0 x8 Y N8103 149 RAID Controller 512MB RAID 0 1 PCIe 2 0 x8 Y N8103 150 RAID Controller 512MB RAID 0 1 5 6 PCle 2 0 x8 Y N8103 151 RAID Controller 1GB RAID 0 1 5 6 PCle 2 0 x8 Y N8103 167 RAID Controller 1GB RAID 0 1 5 6 PCle 3 0 x8 Y N8104 138 1000BASE T Adapter 1ch PCle 2 0 x1 vo Y x N8104 132 1000BASE T Adapter 2ch PCle 2 0 x1 Y Y Y N8117 01A Serial Port Adapter y Y di Y Not supported on 3 5 inch model NEC Corporation Revision 2 0 November 7 2012 33 CONFIGRATION GUIDE NEC Express5800 GT110e S Air cooling model Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice Microsoft and Wi

Download Pdf Manuals

image

Related Search

Related Contents

Ion Chamber Replacement for VS Series Leak Detector  製品の特徴 概要  File 1  72641 - Papelar  Hitachi 57F510 Projection Television User Manual  Samsung GT-S5570 Uporabniški priročnik  Service Manual  split-type air conditioners - Aire Acondicionado Mitsubishi Electric  Merit Roster Processing Instructions  Western Digital My Passport Essential 320GB  

Copyright © All rights reserved.
Failed to retrieve file