Home

NEC Express5800/120Lh User's Guide

image

Contents

1. 15 16 Step 2 Preparing the Required Tools Required tools are listed below Phillips screwdriver Chapter 2 Installation This chapter describes the procedures for installing the rack mountable server into a 19 inch rack Step 1 Convert from tower type to rack mount type 1 Pull the hinge pin out Then slide the front bezel to remove it from the other hinge pin and remove the front bezel 2 Remove the bezel hinge four screws 3 Remove five nylon rivets from the top cover Front Bezel Nylon Rivet Dh TUM Bezel Hinge Hinge Pin Foot 5 Fix the device covers together with the dummy covers which were installed to blank bays in the chassis Device Cover 6 Fix the HDD cover 1 or 2 with the screw D to the inside of front cover Do not attach the HDD cover into Hot Plug SCSI HDD 6slots model 2s Fixed HDD 4slots model Fix HDD cover 1 with four screws D 8 Front Cover A f ANN 4 ACN S ANY tmn AA A ALU LY HDD Cover 1 AI ANIKI ae ae 2 Hot Plug ATA HDD 4slots model Fix HDD cover 2 with two screws D Front Cover pe HDD Cover 2 7 Fix four foot covers with four screws C to the bottom of server 8
2. 120Ef Model Name Label Icon UU 5800 120 30007120 Lh 2E 243 200671 104 A 1 N8143 56F 3 For NEC Express5800 120Lh For NEC Express5800 120Eg For NEC Express5800 120Lg For NEC Express5800 120Lh For NEC Express5800 120Ef For NEC Express5800 120Eg Chapter 3 Operation Step 1 Attaching Removing the arm stopper This cable arm is rotated to backside for connection of external cables and exchange of the power supply unit This step describes the procedures for rotating the cable arm to backside 1 Loosen the screw D and slide the arm stopper to upside and then remove the arm stopper Rotate the cable arm to backside 3 Attach remove cables and power supply units 4 Rotate the cable arm to previous position 5 Attach the arm stopper and then tighten the screw D that was loosened in 1 2 Cable Arm Arm St ae i i a Screw D O L Step 2 Sliding the server out from the rack It is necessary to slide the server out from the rack when doing maintenance of the internal components This step describes the procedures for sliding the server out from the rack Caution Note sufficiently that your fingers may not be caught between a rail and other mechanical parts or cut by a rail at installation or removal of the server from the rack 1 Loosen four captive thumbscrews on the front of the server 2 Grasp the two handles on the front of the server slowly pull it ou
3. the slide rail assembly and neighboring units Failure to follow these instructions may cause the server to operate incorrectly and or personal injury or damages of surrounding servers to occur Do not disassemble repair or modify the server Otherwise an electric shock or fire may be caused 856 122660 101 A Rev 1 2 Chapter 1 Preparation for Installation This chapter describes preparations required for installing the server on a 19 inch rack step by step Step 1 Unpacking The rack conversion kit contains the following components Make sure that everything listed below are inside and no damage is observed after unpacking FrontCover Ji S O 2 Slide Rail Assembly J2 gt S 3 CableArm JIi o O 4 ArmBracket I 5 Arm Stopper JIi O EIA Mounting Flange to Rear A SUPPONI 1 Mounting Flange 700_743mm EIA Mounting Flange to Rear A UPRONA Mounting Flange 743_900mm Foot Cover 4 3 For 5 25 bay i 3 HDD Cover 1 For Fixed HDD model HDD Cover 2 1 For Hot Plug ATA HDD model r Template A a S 1 120Lgp 120Ef 1 Model Name Label 120Lh0 120Lg J 0 T Model Name Label Icon Label e Washer __________ 8 Forfixing the slide rail assembly M4 Bind head screws 17 SoewA 8 ieoor Gol 19 Sewe 8 iorsin S color silver M4 pan head screws with Washer Coor eld 21 Cable Tie O Z o Jio S 10 11 12 13 14
4. ties not to contact the slide rails and neighboring units and the rack Tie cables slackly between the cable arm and the server to avoid of excess force to be added by pulling out the server and pushing it back in Attach cables to avoid of excess force to the plug of power cords e HESS a VA Whi LHUNDEEEES 0 ABELB ELE ELRE 9 Check to see that no excess force is applied to cables by pulling out the server and pushing it back in And this cable arm is rotated to backside for connection of cables and exchange of the power supply unit Check to see that no excess force is applied to cables by rotating it If the excess force is applied to cables tie again cables more slackly and check to see that no excess force is applied to cables and check the cable does not touch slide rails neighboring units and the rack 10 Fix the arm stopper with a screw D to the cable arm Arm Stopper Cable Arm UU Step 4 Applying the labels 1 Stick the model name label corresponding to each model on the front cover 2 Stick the icon label corresponding to each model on the front cover 10mm WRN INTEC NEC Express5800 120L8 PARES NEC NEC EXPRESSOGOO71Z20ET TAHTES For NEC Express5800 120Lg For NEC Express5800
5. Fix the front cover with four screws C to the front of server Foot Cover Front Cover Step2 Mounting the server into the rack 1 Fully slide the rails out until they lock in place And while pressing down on the release lever slide the rails to remove the inner rail Slide Rail Assembly Outer Rail Inner Rail 2 3 Place the template in the desired location of the rack and attach four core nuts that come with the rack assembly to the mount flange in the rack Core nut positions Cable Arm position Core nut positions Slide Rail Slide Rail Front side Back side 4 Loosen three screws for fixing the rear mounting bracket in order to move the rear mounting bracket Repeat this step for the other rail Rear Mounting Slide Rail Assembly Outer Rail screws for Rear Mounting bracket 5 Place slide rail assemblies to the mounting flanges of the rack Attach the washer to the screw B and then fix
6. Keep this User s Guide at hand for quick reference at any time it may be required Read SAFETY NOTES first then set up this kit Provide this User s Guide along with this kit when you transfer to the third party N8143 56F 56E Rack Conversion Kit User s Guide Preface This product is mechanical parts for installing NEC Express server into 19 inch rack system Read this document and the manual of the NEC Express server to understand installation method before installing this product to the server SAFTY NOTES Follow instructions given in this document for proper installation and safe use of the server Refer to the User s guide of the NEC Express server regarding the safety indications Caution Install this kit only to the server which define as optional parts Failure to follow these instructions may cause the server to operate incorrectly and or personal injury or damages of surrounding servers to occur More than two persons are required to carry or install the rack Failure to follow this instruction may cause the rack to fall to result in personal injury and or breakage of surrounding servers Read this document and the manual of the NEC Express server to understand installation method before installing this product to the server Failure to follow these instructions may cause the server to operate incorrectly and or personal injury or damages of surrounding servers to occur Attach cables not to contact
7. both sides of slide rails with eight screws B Refer to the template for the position Front side Back side 6 Tighten six screws that were loosened in 4 7 Slide two slide rails out from the rack until they were locked And then with three or more persons assisting you lift the server and align the inner rails attached to the both side of the server with the extended rails 8 Insert the inner rails into the extended slide rails and push the server into the rack until it stops 9 Carefully press down the release levers on the inner rails to release the locks and slide the server all the way into the rack 10 To check that the server slides in and out of the rack grasp the two handles on the front of the server slowly pull the server out and push it back in 11 Tighten the four captive thumbscrews to secure the server to the rack Caution Note sufficiently that your fingers may not be caught between a rail and other mechanical parts or cut by a rail at installation or removal of the server from the rack Front Cove Captive thumbscrews Release Lever 5 Do not connect any cables before attaching the cable arm Secure four captive thumbscrews when mounting the server to the rack Step 3 Installing the cable arm and cables 1 Fix the arm bracket with two screws D to the back of the server Server Arm Bracket eel ala IE vy a Ni 0 a 3 4 A 3 2 When th
8. e distance between the front mounting flange and the rear mounting flange is about 743mm align one end of the cable arm with the outside of the core nuts installed to the rear of the rack frame and secure it with the two screws B gl 5 al 5 Cl i 3 When the distance is from 700mm to 742mm use the arm support 1 to adjust the position of cable arm 4 When the distance is from 745mm to 900mm use the arm support 2 to adjust the position of cable arm Arm Support 2 Arm Support 1 Cable Arm Cem l Attach the cable arm il to the arm support to TI shorten this distance as much as possible Distance between the front mounting Distance between the front mounting flange and the rear mounting flange flange and the rear mounting flange 700 _ 742mm 745 _ 900mm 5 Align the small holes in the cable arm and the arm bracket and then fix the cable arm with two screws D to the arm bracket that fixed in step 1 Arm Bracket Small Hole UU 6 Check to see that no excess force is applied to the cable arm by pulling out the server and pushing it back in And this cable arm is rotated to backside for connection of cables and exchange of the power supply unit Check to see that no excess force is applied to the cable arm by rotating it 7 Attach cables to the server according to the manual of the server 8 Bundle cables to the cable arm by the repeat ties Attach cables and repeat
9. t until it stops locks by the release levers 3 Do the maintenance of internal components according to the manual of the server 4 Carefully press down the release levers on the inner rails to release the locks and slide the server all the way into the rack 5 Grasp the two handles on the front of the server slowly push it in until it stops 6 Tighten four captive thumbscrews on the front of the server Front Cove Captive thumbscrews Release Lever no 856 122660 101 A Rev 1 2