1. E18 NN E19 00 E20 00 E21 00 E22 NN E23 00 E24 00 E39 00 E40 00 E50 00 E51 00 Key fob transmitter low battery NN key fob transmitter number User Program memory error Dealer Program memory error System shutdown Sensor activity failure NN zone number Burglary bus failure Service message Receiver capacity error RF Self Test Fail Alarm Output Supervisory Bell Supervisory 29 Wednesday August 18 1999 14 03 NOTES 30 GEM RP3DGTL pub page 30 Wednesday August 18 1999 14 03 NOTES 31 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 31 NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS INC NAPCO warrants its products to be free from manufacturing defects in materials and workmanship for thirty six months following the date of manufacture NAPCO will within said period at its option repair or replace any product failing to operate correctly without charge to the original purchaser or user This warranty shall not apply to any equipment or any part thereof which has been repaired by others improperly installed improperly used abused altered damaged subjected to acts of God or on which any serial numbers have been altered defaced or removed Seller will not be responsible for any dismantling or reinstallation charges THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHAN
2. ADVANCED FEATURES 7 VES NO PROGRAMMING KEYPAD PANIC ENABLED KEYPAD FIRE ENABLED KEYPAD MESSAGES YES NO KEYPAD AUX ENABLED GLOSSARY e SYSTEM TROUBLE ERROR CODES FIRE HAS PRIORITY OVER BURGLARY GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 3 INTERIOR BYPASS FIRE TBL SYS TBL CHIME GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 4 KEYPAD CONTROLS amp INDICATORS Window Window Lights indicate RESET Button 1 Resets various O AREA Button Selects other ar system status messages digit display indicates related zone function or er ror message numbers STATUS Light Lights green to indi cate that the system is ready for arm ing If a zone is not secured the light will be off and the zone will display in the window If a zone has been by passed the STATUS light will blink while armed ARMED Light Lights red to indicate that the system is armed If an alarm has occurred the ARMED LED will be flashing FUNCTION Button Selects available system functions as displayed in the window The selected function is exe cuted by pressing the _ to button or the YES nero button BYPASS Button 1 Deactivates se lected zones from the system 2 Un bypasses a bypassed zone GEM RP3DGTL pub page 5 system troubles displays etc See text 2 Resets residential smoke detectors Numerical Keys 1
3. imitation of incidental or consequential damages or differentiate in their treatment of limitations of liability or ordinary or gross negligence so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may also have other rights which vary from state to state does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient the receiving antenna relocate the computer with respect to the receiver move the computer away from the receiver plug the computer into a different outlet so that computer and receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications NAPCO Security Systems 333 Bayview Avenue Amityville NY 11701 GEM RP3DGTL pub page 32 01249 6 99 Wednesday August 18 1999 14 03
4. 6 Call the Fire Department from a neighbor s telephone Would You Like More Safety Information For more information on home fire detection burn safety and home fire safety write to the National Fire Protection Association Public Affairs Dept 05A Batterymarch Plaza Quincy MA 02269 GEM RP3DGTL pub page 13 Wednesday August 18 1999 14 03 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan 14 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 14 FIRE PROTECTION LIMITATIONS OF FIRE ALARM WARNING SYSTEMS Although a fire alarm system may be of a reliable and state of the art design neither it nor its peripheral detection devices can offer guaranteed protection against fire Any such equipment may fail to warn for a variety of reasons Control panels communicators dialers smoke detectors and many other sensing de vices will not work without power Battery oper ated devices will not work without batteries with dead batteries or with improperly installed bat teries Devices powered solely by AC will not work if their power source is cut off for any reason Fires often cause a failure of electrical power If the system does not contain a working battery backup power supply and if the electrical circuit feeding the devices is cut or is not providing power for any reason the system will not detect heat or smoke or provide any warning of a pos
5. 7 Activate Chime The Chime Mode will sound a tone at the keypad when the programmed zone is opened while disarmed To deactivate the Chime Mode execute Function 7 once again Note The Chime Mode is disabled while armed 8 Activate Watch Mode Watch Mode programmed Oves LI NO This optional feature simultaneousiv turns on all zones designated as Dav Zones To deactivate the Watch Mode arm then disarm All Dav Zones will revert to regular Burglary Zones Note The Watch Mode is disabled while armed Wednesday August 18 1999 14 03 GEM RP3DGTL pub page 18 INTERIOR U INTERIOR INTERIOR O U INTERIOR INTERIOR FIRE TBL FIRE TBL FIRE TBL FIRE TBL FIRE TBL SYS TBL SYS TBL SYS TBL SYS TBL SYS TBL 9 Reset System Trouble System troubles display and sound at the keypad Correcting the trouble will clear most indications however the following error codes will require manual reset E11 E13 E19 E20 and E22 See SYSTEM TROUBLE ERROR CODES for a description of error codes 10 For installer s use only If accidentally enabled press the resm button to exit 11 Start Exit Time Start Exit Time programmed O yes LI NO In Commercial Burglary systems exit delay may have been programmed to start after a central station ringback verification signal has been received If the ringback tone has not been received within about 30 seconds after arming a communication proble
6. be restored first then the panel are l oo BA Ed BA i s 4 AN armed and disarmed all within HP moo oO oo oo FO EE the delay period l PN JIGITAL COMMUNICATOR FA GM PG FH G FB GA GG FA EB Opening and or Closing Report pni oe Xi ing Vour svstem can notifv the central A gt station every time it is disarmed or PROTECTED PREMISES PROTECTED PREMISES 21 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 21 ADVANCED FEATURES Security Bypass Unbypass Security Bypass programmed L YES LINO In high security applications zones may be bypassed or unbvpassed only if a valid code is entered first as follows ie 1 Enter a code valid for bypass then press the button IS 2 Press the button then the zone number or vice versa to deactivate that zone Similarly a bypassed zone may be unbypassed using the foregoing procedure 22 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 22 ADVANCED FEATURES Start Exit Time After Ringback for Commercial Burglary Systems only Start Exit Time programmed O YES ONO If your system reports to a central station your panel may have been programmed to start exit delay after the central station ringback verification signal Then after arming your system will communicate to the central station After the central station acknowledges receipt ringback exit delay will start If ringback is not heard within about 30 seconds a communication problem may exist call for servic
7. come on momentarily to indicate that there is a problem on the zone GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 11 FIRE PROTECTION Applicable only where local ordinance permits use of this alarm control panel for fire protection _ Fire Zone Alarm If a fire is detected the FIRE TBL light will display with the zone number and the keypad sounder will pulse 1 If a fire is in progress evacuate the premises immediately If necessary call the Fire Department from an outside phone 2 If there is no evidence of a fire enter your code and press the ILI button to turn INTERIOR BYPASS FIRE TBL SYS TBL CHIME off the alarm 3 Check smoke detector s If a smoke detector tripped its red alarm indicator light will be on 4 Press the button to silence the keypad sounder 5 After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing the button again will reset the keypad within about 10 seconds Fire Zone Trouble 5 5 e 1 Ifa problem on a fire zone is detected the zone number will display along with m the FIRE TBL fire trouble light a flashing SYS TBL light and the sounder will pulse to signal a malfunction 2 Press the button to silence the sounder Call for service immediately INTERIOR BYPASS FIRE TBL SYS TBL CHIME GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 12 FIRE PROTECTION Preparing a Fire Escape Plan Even wi
8. enabled pressing to gether with LJ 22 or L27 will alert the central station of a fire auxil iary or police emergency Partitioned System A system that has been subdivided into two or more up to eight independent subsystems areas Pre Alarm Warning A keypad sounder alert of an impending alarm This option is programmable by zone for the same duration as that pro grammed for Abort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless sys GEM RP3DGTL pub page 27 tems only Weak transmitter bat tery RF Check In Wireless systems only Periodic test report from trans mitter if a report is not received on time a supervisory failure system trouble will result Ringback A beep after arming verifying the central station s receipt of a closing report Service Code A code intended for temporary use Sounder A local warning device at each keypad to alert that a entry delay has started b an attempt was made to arm with a zone in trouble c a Day Zone condition exists see Zones Day Zone d 10 seconds exit time remaining e invalid code entered or f central station acknowledged arming see Ringback System Trouble A problem low battery power failure etc detected in the system Trouble A zone fault an open door window or o
9. testing and due to but not limited to any or all of the following criminal ampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or hat the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all cases provide adequate warning or protection A properly installed and maintained alarm may only reduce risk of burglary robbery fire or otherwise but it is not insurance or a guarantee that these events will not occur CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING Therefore the installer should in turn advise the consumer to ake any and all precautions for his or her safety including but not limited to fleeing the premises and calling police or fire department in order to mitigate the possibilities of harm and or damage NAPCO is not an insurer of either the property or safety of the user s family or employees and limits its iability for any loss or damage including incidental or consequential damages to NAPCO s original selling price of the product regardless of the cause of such loss or damage Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or
10. your system reports on arming not heard call for service digital communicator can transmit Closing Report the central station emergency signals and status reports will acknowledge arming This will to the central station 24 hours a day S NOTIFIED ONDITION Communicator Features Abort Delay Ask your installer which of your zones have abort delay a delay that enables you to reset the system before it communicates to the central station MTS e Regular Burglary Non 24 Hour Zone reports are aborted by dis BoE hie arming within the delay period NIM p m oo oo oo l e 24 Hour Zones and zones pro A rija co bo od m oo bo oo grammed to report restores must MA TETT co fo Go Go Go Go ced Go oo od
11. 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected function to be executed INTERIOR Button 1 Bypasses all Interior Zones simultaneously to allow free movement within the premises 2 Scrolls the window display forward NEXT 3 Answers YES to ques tions in the window display INSTANT Button 1 Cancels entry delay on Exit Entry Zones causing an instant alarm upon violation 2 Scrolls window display backward PRIOR 3 Answers NO to ques tions in the window display eas Emergency Buttons Used with the button to signal an emergency as follows ePress the and the buttons for Fire Emergency ePress the and the buttons for Auxiliary Emergency ePress the and the buttons for Police Emergency 3 AC Light Indicates AC Power is pre sent Wednesday August 18 1999 14 03 SETTING THE ALARM ARMING WHEN LEAVING 1 Check the keypad The green STATUS light must be on in order to arm O O O O O e If the green light is off the number s of any unsecured zone s will display in the INTERIOR BYPASS FIRETBL SYSTBL CHME window Note each problem zone and secure it by closing a window door etc When all zones are secure the green STATUS light will come on e Bypass faulted zones If you cannot locate or repair the problem yourself call for assistance If you cannot get immediate help bypass the problem zone s from the system by
12. OFF THE ALARM DISARMING WHEN RETURNING Ambush Ambush programmed LIvEs LINO The Ambush Code optional is a 2 digit code that is entered just prior to your Disarm Code If an intruder forces you to disarm your system a enter your Ambush Code b enter your Disarm Code c press the JEJ button Example If your regular Arm Disarm Code is 1234 and your Ambush Code is 99 press L3 LA LLI EI This will send a silent alarm to the central station The red ARMED light will go out and the keypad will appear as if the system were merely disarmed There will be no indication that an alarm has been sent Day Zone Day Zone s programmed J YES NO A Day Zone is used to monitor a secured exit door window foil etc A problem on this type of burglary zone will cause a pulsing keypad sounder while disarmed To silence the sounder press the button or arm and disarm if so programmed Correct the problem to reset the Day Zone 24 Hour Zone 24 Hour Zone s programmed LIYES LINO This zone is always armed even if the system is disarmed If there is no audible output bell siren etc programmed for this zone it will behave as a regular Burglary Zone however an alarm will be reported to the central station and recorded in the Alarm Event Log If an audible output is programmed a 24 Hour Zone will behave as an armed Burglary Zone If the system is subsequently armed with a 24 Hour Zone in trouble the keypad sounder will
13. OPERATING GUIDE for your GEM RP3DGTL KEYPAD o INTERIOR BYPASS FIRE TBL SYS TBL CHIME NEXT YES FUNCTION 3 J PRIOR NO BYPASS 6 kd AREA RESET 9P 0 COMPUTERIZED SECURITY SYSTEM NAPCO 1999 DESIGN PATS PENDING GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 1 INTRODUCTION The GEM RP3DGTL is a smart in teractive menu driven keypad de signed for your Napco control panel A digital display is provided to show the status of your system This booklet contains important infor mation about the operation of your sys tem with this GEM RP3DGTL Keypad Read it carefully and keep it handy for future reference Check the Glossary for an explanation of terms that may be unfamiliar to you You ll probably find subjects men tioned in this booklet that do not apply to your system Napco control panels have such a wide variety of features that few security systems if any will ever need them all Your alarm professional has chosen ap propriate features for your particular needs Regardless of how your system has been configured rest assured that it has been carefully designed and en gineered to the highest industry stan dards To assure optimum safety and security familiarize yourself with this equipment Periodically check its con dition and state of readiness by testing it at least once a week in both the ac battery and battery on
14. TABILITY OR A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ADDITIONALLY THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF NAPCO Any action for breach of warranty including but not limited to any implied warranty of merchantability must be brought within the six months following the end of the warranty period IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT In case of defect contact the security professional who installed and maintains your security system In order to exercise the warranty the product must be returned by the security professional shipping costs prepaid and insured to NAPCO After repair or replacement NAPCO assumes the cost of returning products under warranty NAPCO shall have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered defaced or removed NAPCO will not be responsible for any dismantling reassembly or reinstallation charges This warranty contains the entire warranty It is the sole warranty and any prior agreements or representa tions whether oral or written are either merged herein or are e
15. ck 3 The display will scroll the following P Program mode 4 digits identifying software versions then UP User Pro gram The keypad will continue to flash while programming user codes 4 Set the cursor to the user number with the the button 5 Using the number buttons enter a User Number as a two digit number enter 1 9 as 01 09 Wednesday August 18 1999 14 03 PROGRAMMING OPTIONAL 6 Continuing set the cursor to the To Program User Codes user code with the button and enter the new User Code using the number but the EE button hen press tons Press for any blank loca 2 Press NO STATI until 17 z O ED lt gt tions until you end up back to the flashing displays then press YES NOR BYPASS FRETA SYSTAL CHINE UP mo 7 Press the button to save the code 3 When UP displays with a flashing light use the number in memory buttons to enter a 2 digit user Repeat Steps 4 through 7 for each number followed bv a user code user of up to 6 digits Note To void a code simply enter the 4 Press the button to save 2 digit user number then press the but 5 Repeat steps 3 amp 4 to enter all user codes ton 6 Press the button to exit Programming Example Example Program User 3 s Code as NOTE Press button to clear character a
16. d to an emergency situ ation Wednesday August 18 1999 14 03 SYSTEM TROUBLE ERROR CODES Your control panel is capable of detecting a variety of troubles that may affect system performance In the unlikely event that a problem should occur the SYS TBL system trouble light will display in the window along with one or more of the following error codes Several of these messages are intended for use by your installer or servicer If any message appears that is unfamiliar to you call your security professional for service E01 00 E02 00 E03 00 E04 NN E05 NN E06 NN E07 00 E08 00 E09 00 E10 NN AC power failure System low battery Communication failure RF transmitter supervisory Failure NN transmitter number RF transmitter low battery condition NN transmitter number Receiver response failure NN receiver number Download failure Telephone line failure System cold start Keypad response failure NN keypad number GEM RP3DGTL pub page 29 E11 NN E12 NN E13 NN E14 NN E15 NN E16 NN E17 NN Keypad tamper condition NN keypad number Expansion zone module response failure NN module number Expansion zone module tamper condition NN module number Relay board response failure NN relay board number Rf transmitter tamper condition NN transmitter number Receiver jammed NN receiver number Receiver tamper condition NN receiver number
17. e Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was not programmed exit delay will start as soon as your code is entered Also note that if an exception window is programmed and the closing is within that window no ringback is provided Ask your alarm professional if this feature is enabled Exit Delay Restart Exit Delay Restart programmed L YES LINO On arming the programmed exit delay will start After the exit door has been opened and then closed exit delay will change to 60 seconds Thus a long exit delay may be programmed which will immediately be reduced to 60 seconds upon exiting If re entry occurs during that 60 seconds exit delay will restart once again and only once again at 60 seconds If so programmed re entry within 60 seconds after exit delay has expired will cause the alarm to sound a 2 second warning in addition to the entry sounder to remind the user to disarm 23 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 23 PROGRAMMING OPTIONAL Introduction The Program Mode optional is used to customize User Codes Access to the Program Mode requires a special User Code therefore not all users may have the ability to program Note elf the system contains more than one keypad only the keypad desig nated No 1 may be used for pro gramming if in doubt which
18. hour 15 minute delay press 4 then the a button Fifteen minutes prior to arming the siren will sound a 2 second warning and the keypad will begin a 15 minute countdown with the sounder pulsing During this time arming may be delayed an additional 1 to 4 hours as above or autoarming may be cancelled by arming and disarming the panel Wednesday August 18 1999 14 03 o INTERIOR BYPASS FIRE TBL SYS TBL O 5 O DU INTERIOR BYPASS FIRE TBL SYS TBL ET U VW INTERIOR BYPASS FIRE TBL SYS TBL CHIME 20 GEM RP3DGTL pub page 20 17 Activate Program Program Mode programmed for user YES LINO Activates the Program Mode from Keypad No 1 only Note This feature is disabled while armed 18 Activate Download For installer s use only If accidentally enabled press the Reser button to exit Note This feature is disabled while armed 19 Relay Control Turns on or off one or more programmed Relay Groups Press the _ button to turn the displayed group on or off press NEXT to proceed to the next group or PRIOR to scroll back to the previous group Press the Feser button when done Wednesday August 18 1999 14 03 CENTRAL STATION MONITORING Your alarm specialist may have armed Any or all of up to 96 differ signal at the keypad as a ringback programmed your system to be moni ent users can each be identified If beep Note If the ringback signal is tored by a central station The built in
19. is No 1 ask your installer e Operation of the keypad buttons in the Program Mode is different from that for normal operation Refer to the accompanying diagram for key pad functions in the Program Mode elf the selected function requires more than one screen scroll the dis play using the farma button e While in the Program Mode the ARMED and STATUS lights remain off and burglar and fire alarm func 24 GEM RP3DGTL pub page 24 tions are disabled e f the keypad detects no activity in the Program Mode for more than 4 minutes a tone will sound to silence the tone press the button e The programmed code or descrip tion will not be permanently stored until you press the button e To exit the Program Mode press the reser button Programming User Codes Do not attempt to program a code containing any blank spaces between dig its In selecting your codes do not pro gram repetitive numbers 1111 consec utive numbers 1234 your birth date address or other obvious combinations Choose a code of up to six digits a minimum of four is recommended and required in UL installations The User Program Mode is accessed from the Function Mode as follows 1 Enter your code then press the button to enter the Function Mode 2 Answer NO press the button until 17 Activate Program is displayed then press the YES furscej button Note If you pass 17 press the button to scroll ba
20. l enable you to arm in this condition Be sure to call for service as soon as possible Area Arming Optional In a system that has been partitioned into multiple areas one or more areas may be armed while others remain disarmed Manager s Mode The Manager s Mode if enabled provides quick access to other areas without the system status display This is not a high security feature To arm any area 1 Press the numerical key representing the area number 2 Press the button then the B button In effect you will now be in that area 3 Enter your code then press the _ button to arm Note Your code must be valid in that area To arm all areas simultaneously including the area you are in press CEF CJ enter your code and press the _ button If any zone is not secured the keypad will display P All problem zones in the respective area s must be secured or bypassed before the area can be armed Note If a system trouble is indicated the system cannot be armed using this method To disarm all areas press LOJ enter your code and press the _ button GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 7 PROTECTING YOURSELF WHILE ON THE PREMISES 79 Bypassing Interior Zones Interior Zones when bypassed allow free movement within the premises while the protection of armed perimeter zones is maintained If the button is pressed all Interior Zones will be bypassed upon arming Some control pa
21. ly modes ask your alarm professional how to make these tests IMPORTANT TEST YOUR SYSTEM WEEKLY 2 While disarmed enter your User Code then press the button Test your sounding device telephone line 1 While disarmed enter your User Code then press the button 2 Answer NO press nstwr button until 3 Bell Test appears in the window 3 Press YES press NERor button to execute the test The alarm will sound for about two seconds If the alarm does not sound or sounds weak call for service Test your telephone line 1 Notify your central station of the impending test GEM RP3DGTL pub page 2 3 Answer NO press nsrar button until 15 Telephone Test appears in the window 4 Press YES press irEnorj button to send a test code to the central station 5 If the test is not successful E 03 will display indicating a communi cation failure Call for service Note Any subsequent successful transmission will clear a E 03 system trouble Wednesday August 18 1999 14 03 TO SHUT OFF AN ALARM EN TABLE OF CONTENTS TER YOUR CODE THEN PRESS THE BUTTON KEYPAD CONTROLS amp INDICATORS FOR SERVICE CALL SETTING THE ALARM ARMING WHEN LEAVING ENTRAL STATION PROTECTING VOURSELF WHILE ON THE PREMISES EXIT DELAY TURNING OFF THE ALARM DISARMING WHEN RETURNING ENTRY DELAY Section KEYPAD FUNCTIONS BURGLAR ALARM SOUND CENTRAL STATION MONITORING
22. m may exist Use this function to start exit delay manually then exit the premises immediately Be sure to have your alarm specialist check communications with the central station as soon as possible 12 Activate Fault Find For installer s use only If accidentally enabled press the st button to exit 13 Activate Locate For installer s use only If accidentally enabled press the s button to exit Wednesday August 18 1999 14 03 O O INTERIOR BVPASS FIRE TBL INTERIOR BYPASS FIRE TBL O U VW INTERIOR BYPASS FIRE TBL GEM RP3DGTL pub page 19 SYS TBL U SYS TBL SYS TBL CHIME CHIME CHIME 14 Activate EZM Zone Find For installer s use only If accidentally enabled press the Reser button to exit 15 Activate Telephone Test Telephone Test programmed YES LINO Sends a communicator test to the central station A communication failure will be indicated at the keypad by a system trouble 3 display Repeat the test to attempt to correct a communication failure as any successful communication will clear this display 16 Delay Arming 1 4 Hours Not for UL listed systems Allows automatic arming to be delayed up to 4 hours 15 minutes as follows on For a 1 hour 15 minute delay press 1 then the loFF on For a 2 hour 15 minute delay press 2 then the loFF jon For a 3 hour 15 minute delay press 3 then the button lorF For a 4
23. nels have provisions for two groups of Interior Zones Enter your code then press the button The red ARMED light will come on INTERIOR BYPASS FIRE TBL SYS TBL CHIME and the green STATUS light will blink indicating zones bypassed After the exit time has elapsed the BYPASS and INTERIOR arrows will display in the window Instant Protection When retiring for the evening after everyone is at home you will probably want to cancel the entry delay on the Entry Zone s Then if armed opening the entry door will cause an instant alarm When arming exit delay will remain in effect To cancel the entry delay while on the premises merely press the button it may be pressed either before or after arming Note While armed the red ARMED light will flicker rapidly to indicate instant protection GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 8 PROTECTING YOURSELF WHILE ON THE PREMISES 1 2 5 ON INTERIOR A 4 5 6 OFF INSTANT 7F BA 9P 0 RIZED SECURITY S U tx NAFCO GEM RP3DGTL pub page 9 Emergency Buttons Only available if programmed The Blue Emergency Buttons F A and P if programmed are always active whether the system is armed or disarmed The emer gency signal will only be activated when the respective Emergency Button and the button are pressed at the same time e Fire Emergency Simul
24. pressing the button then the zone number or vice versa Note Bypassed zones are unprotected If armed with zones bypassed be sure to have the system checked as soon as possible 2 Arm the system Enter your code and press the _ button The green STATUS light will go off the red ARMED light will come on Note If you enter an invalid code the keypad will beep 4 times signifying an error Re enter your code immediately 3 Leave the premises Leave through the exit door before exit time expires Priority Arming If you attempt to arm a faulted Priority Zone a 3 second tone will sound at the keypad and P will display in the window indicating that the trouble s must be corrected O O e O jbefore the panel can be armed A zone selected as Priority Zone with Bypass check your INTERIOR ByPass FlRETBL sse ce Alarm Plan may be bypassed if in trouble If the problem cannot be corrected immediately press the button then arm the panel A 3 second beep will sound at the panel to indicate arming with a Priority Zone in trouble Be sure to have the trouble repaired as soon as possible GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 6 If you attempt to arm with a system trouble a 3 second tone will sound at the keypad O O O O See SYSTEM TROUBLE ERROR CODES for descriptions of codes The window will Nemon BVPASS Frere sse cHue Jdisplav P If you cannot correct the problem immediately pressing the button wil
25. r conditioner or other appliance or by passing traffic etc Alarm warning devices however loud may fail to warn the hearing impaired e Alarm products as all electrical devices are subject to component failure Even though the equipment is designed for many years of trouble free performance electronic compo nents could fail at any time Above are some of the reasons that fire alarm equipment could fail The most common cause of an alarm system not functioning when a fire occurs is inadequate testing and maintenance The system should be tested at least weekly to ensure that all the equipment is working properly While an alarm system may make one eligible for lower insurance rates it is not a substitute for insur ance Homeowners property owners and renters are therefore urged to maintain adequate insurance cover age of life and property 15 Wednesday August 18 1999 14 03 KEYPAD FUNCTIONS The keypad can provide a wide assortment of utility functions The functions are displayed in a prompting yes no format To skip a function answer NO press the ferm button to select and execute a function answer YES press the button or press the J J button Note Functions may be manually scrolled forward or backward using the fueraj and buttons respectively To return to normal keypad operation press the esej button The keypad will automatically return to its normal operating mode if no activity is detected fo
26. r longer than one minute Note In all UL listed applications and in high security installations only those users having valid codes can access the Function Mode e 1 Display Zone Status Identifies zones that are not secured Press the NEXT 0 0 DO DO OC and PRIOR Buttons as displayed on screen to scroll faulted zones INTERIOR FIRE TBL SYS TBL CHIME a 6 2 Display Zones Bypassed Displays manually bypassed zones Press the NEXT WNE ENIE and PRIOR Buttons to scroll bypassed zones 3 Activate Bell Test Activates the alarm while disarmed for about 2 seconds If the alarm does not sound call for service FIRE TBL SYS TBL CHIME GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 16 INTERIOR U INTERIOR U INTERIOR INTERIOR U INTERIOR GEM RP3DGTL pub page 17 FIRE TBL FIRE TBL FIRE TBL FIRE TBL FIRE TBL SYS TBL SYS TBL SYS TBL SYS TBL U SYS TBL 4 Display System Troubles Displays a 1 or 2 digit error code represeniing a problem detected in the system See SYSTEM TROUBLE ERROR CODES fora description of these codes Use NEXT and PRIOR Buttons to scroll system troubles 5 Display Fire Alarms Displays alarms that have occurred on the Fire Zone s Press the NEXT and PRIOR Buttons to scroll zones 6 Display Fire Troubles Displays trouble conditions that have been detected on the Fire Zone s Press the NEXT and PRIOR Buttons to scroll zones
27. sible fire Telephone lines needed to transmit alarm sig nals to a central monitoring station may be out of service Smoke detectors though highly effective in reducing fire deaths may not activate or provide early enough warning for a variety of reasons a they may not sense fires that start where smoke cannot reach them such as in chimneys walls roofs behind closed doors etc b they may not sense a fire on a different level of the residence GEM RP3DGTL pub page 15 or building c they have sensing limitations no smoke detector can sense every kind of fire every time Thermostatic heat detectors do not always detect fires because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen levels smoke toxic gases or flames Therefore they may only be used as part of a comprehensive fire detection system in conjunction with other devices Under no circumstances should ther mostatic heat detectors be relied upon as the sole measure to ensure fire safety e Alarm warning devices such as sirens bells or horns may not alert someone behind a closed or partially opened door Warning de vices located on one level are less likely to alert those on a different level Even those who are awake may not hear the warning if the alarm is obscured by noise from a stereo radio ai
28. t cursor 3784 To continue press or button 1 Select the Program Mode as follows a Enter your code then press the N Programming User Codes button b Answer NO mrar button repeatedly until 17 is displayed then press the YES fror button The display will scroll P followed by 4 digits for installer s use then UP indicating user programming and the lights will continue to flash 2 Press the button then to enter User No 3 then press the button again followed by L3ILTFILSEJLZJLXE JJ Le Co to program the code 25 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 25 GLOSSARY Following are brief descriptions of terms and features used herein that may be unfamiliar to you Some of the features are programmable options that may or may not apply to your particular system Abort Delay A delay period that manually remove one or more pro grammed zone descriptions stored in allows the control panel to be reset tective zones from the system memory thus aborting a report to a central sta Central Station Monitors incom Easy Arming Quick arming by tion ing reports and emergency mes pressing the l button optional Access Code A code up to 6 dig sages from a digital communicator l its used to remotelv unlock a door and notifies the proper authorities Exit Entry Delays Separate delays Ambush Code A 2 digit code en Chime A keypad beep
29. taneously press the and but tons to alert the central station of a fire emergency e Auxiliary Emergency Simultaneously press the and buttons to alert the central station of some other emergency e Police Emergency Simultaneously press the and buttons to alert the central station of a police emergency Wednesday August 18 1999 14 03 TURNING OFF THE ALARM DISARMING WHEN RETURNING 1 Upon entry the red ARMED light will be on and the keypad sounder will come on as a reminder to disarm the panel During the final 10 seconds the sounder will pulse a warning signal 2 Immediately enter your code then press the EJ button The sounder will silence and the red ARMED light will go out Note If you enter an invalid code the keypad will beep 4 times signifying an error Re enter your code immediately Alarm Indication If the red ARMED light is flashing upon entry an alarm occurred while you were out The display will scroll the number s of the violated zone s Proceed with caution If you suspect that an intruder may still be on the premises leave immediately and call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code and press the button After the system is disarmed the window will continue to display the number s of the zone s violated 2 To reset the display note the zones violated then press the esej button GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 10 TURNING
30. th the most advanced fire alarm system adequate protection re quires an escape plan To prepare your plan draw floor plans of your building Space is pro vided on the next page Show two exits a front or back door and a window from each room Make sure the window works You may need a special fire escape ladder if the win dow is high up Write down your out side meeting place Family Rehearsal Rehearse each of the following activities 1 Everyone in his room with the doors closed 2 One person sounds the alarm 3 Each person tests his door 4 Pretend the door is hot and use the alternate escape exit 5 Everyone meets outdoors at the assigned spot Important Read Carefully Discuss these escape procedures with all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the win dow If the door is cool brace your shoulder against it and open it cau tiously Be ready to slam the door if smoke or heat rushes in Crawl through smoke holding your breath Close the doors again on leaving to help prevent the fire from spreading 4 Go to your specific outdoor meeting place so you can see that everyone is safe 5 Assign someone to make sure nobody returns to the burning building
31. ther problem that may prevent arming User Code Your personalized code for arming and disarming the system It may contain up to six digits Zones Independent circuits that protect specific areas of the premises e Auto Bypass Zone A zone that will be automatically bypassed from the protection system if it is in trouble faulty when the sys tem is armed e Burglary Zone Detects intru sion eDay Zone A zone that will cause a visual and audible indica tion at the keypad if it is in trouble while disarmed 27 Wednesday August 18 1999 14 03 GLOSSARY 28 e Exit Entry Follower Zone Pro vides exit and entry delay for inte rior devices Entry delay only oc curs if re entry takes place through the normal exit entry door first e Fire Zone Detects fire alarms or trouble conditions e Interior Zones Circuits within the premises usually including space protection devices interior doors etc but not exterior doors or windows These can all be by passed simultaneously using the button Two groups of Inte riorZones may be programmed for each area e Priority Zone A zone that pre vents arming if in trouble e Priority Zone with Bypass A Pri ority Zone that can be bypassed using the Reser button GEM RP3DGTL pub page 28 e Selective Bypassed Zone A zone that can be individually bypassed using the but ton e 24 Hour Zone A zone that is armed and ready at all times to respon
32. while dis that let you exit and enter your tered just prior to the User Code when armed alerting that the programmed premises without setting off an alarm forced to disarm Sends a silent alarm zone has been opened when the system is armed to the central station with no indication Closing Window Optional A Instant Protection Arming without at the keypad time interval within which closing entry delay using the button Arming Disarming Turning the arming is permitted without report While remaining on the premises system on off by entering your code at ing to the central station INTERIOR Button Bypasses Inte the keypad then pressing the but Communicator Reports intru rior Zones on arming see Zones In sions emergencies openings clos terior Zones ton ings etc directly to the central sta Keypad Puts control panel func Battery Backup power source in tion over telephone lines tions at your fingertips It can be the control panel enclosure to provide Control Panel The brain of the mounted anywhere in your premises protection in the event of a power fail system it controls all system func ure tions BYPASS Button Enables you to Directory A listing of the pro 26 GEM RP3DGTL pub Wednesday August 18 1999 14 03 page 26 GLOSSARY Manager s Mode In a partitioned system a low securitv operating mode that allows arming bv area Panic Buttons Blue buttons on the keypad C x and C7 C89 or L If
33. xpressly cancelled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the product Seller s warranty as hereinabove set forth shall not be enlarged diminished or affected by and no obligation or liability shall arise or grow out of Seller s rendering of technical advice or service in connection with Buyer s order of the goods furnished hereunder NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY Warning Despite frequent