1. A packet with destination address on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Packets that are used in maintaining the operation of the network such as the occasional multi cast packet are forwarded to all ports The TN 5308 operates in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network LED Indicators Several LED indicators are located on the TN 5308 s front panel The function of each LED is described in the table below ED Color State Description Power is being supplied to the power AMBER input Off Power is not being supplied to the power input On TP ports 10 Mbps link is active dom AMBER Data is being transmitted at 10 Mbps On On ing TP port s 10 Mbps link is inactive i Off O TP port s 100 Mbps link is active TP Data is being transmitted at 100 qoom GREEN Blinking Mbps Of TP ports 100 Mbps link is inactive 10 Auto Negotiation and Speed Sensing All of the TN 5308 s Ethernet ports independently support auto negotiation for speeds in the 10BaseT and 100BaseTX modes with operation according to the IEEE 802 3u standard This means that some nodes could be operating at 10 Mbps while at the same time other nodes are operating at 100 Mbps Auto negotiation takes place when a
2. or cross over cable to connect the TN 5308 to Ethernet devices Dual Speed Functionality amp Switching The TN 5308 s 10 100 Mbps switched M12 ports auto negotiate with the connected device to use the fastest data transmission rate supported by both devices All of Moxa s ToughNet switches are plug and play devices so that software configuration is not required The half full duplex mode for the switched M12 ports is user dependent and changes by auto negotiation to full or half duplex depending on which transmission speed is supported by the attached device Switching and Address Learning The TN 5308 has a MAC address table that can hold up to 1000 node addresses which makes it suitable for use with large networks The address tables are self learning so that as nodes are added or removed or moved from one segment to another the TN 5308 automatically keeps up with new node locations An address aging algorithm causes the least used addresses to be deleted in favor of newer more frequently used addresses To reset the address buffer power down the unit and then power it back up Switching Filtering and Forwarding Each time a packet arrives at one of the switched ports a decision is made to filter or forward the packet Packets with source and destination addresses belonging to the same port segment will be filtered constraining those packets to one port and relieving the rest of the network from the need to process them
3. switch This device has ULS08 approval Use copper conductors only 60 75 C and tighten to 4 5 pound inches For use in pollution degree 2 environments ATTENTION Safety First Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Please read and follow these guidelines e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together Keep input wiring and output wiring separated e Itis strongly advised that you label wiring for all devices in the system when necessary Grounding the TN 5308 Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the grounding screw to the grounding surface prior to connecting de
4. 6 1 mm 2 36 x 8 53 x 1 42 in TN 5308 MV 60 x 216 6 x 53 7 mm 2 36 x 8 53 x 2 11 in eee ee Weight Installation Environmental Limits Operating Temperature Storage Temperature Operating Humidity Regulatory Approvals Safety Rail Traffic Traffic Control EMI EMS Shock Freefall Vibration TN 5308 LV 485 g TN 5308 MV 685 g Panel mounting DIN Rail mounting with optional kit Standard Models 0 to 60 C 32 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F 40 to 85 C 40 to 185 F 5 to 95 non condensing ULS508 Pending ENS0155 Environmental Pending EN50121 3 2 Pending EN50121 4 Pending NEMA TS2 Pending e Mark Pending FCC Part 15 CISPR EN55022 class A EN61000 4 2 ESD level 3 EN61000 4 3 RS level 4 EN61000 4 4 EFT level 3 EN61000 4 5 Surge level 3 EN61000 4 6 CS level 3 EN61000 4 8 EN61000 4 11 EN61000 4 12 IEC61373 IEC60068 2 32 IEC61373 Note Please check Moxa s website for the most up to date certification status WARRANTY 5 years Details See www moxa com warranty Technical Support Contact Information Moxa Americas Toll free 1 888 669 2872 1 714 528 6777 1 714 528 6778 Tel Fax Moxa Europe Tel Fax 49 89 3 70 03 99 0 49 89 3 70 03 99 99 Www moxa com support Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Asia Pacific Tel 8
5. 86 2 8919 1230 Fax 886 2 8919 1231 12
6. Moxa ToughNet Switch TN 5308 Series Layer 2 M12 unmanaged Ethernet switches Hardware Installation Guide First Edition May 2009 MOXAN 2009 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802053080010 Overview The ToughNet TN 5308 series M12 unmanaged Ethernet switches are designed for industrial applications in harsh environments The TN series switches use M12 connectors to ensure tight robust connections and guarantee reliable operation against environmental disturbances such as vibration and shock The TN 5308 series Ethernet switches provide 8 Fast Ethernet M12 ports support IEEE 802 3 802 3u 802 3x with 10 100M full half duplex MDI MDI X auto sensing and provide an economical solution for your industrial Ethernet network Models with an extended operating temperature range of 40 to 75 C are also available The TN 5308 series Ethernet switches are compliant with EN50155 50121 3 2 50121 4 railway applications NEMA TS2 traffic control systems and e Mark vehicles requirements making the switches suitable for a variety of industrial applications Package Checklist Your TN 5308 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance e Moxa ToughNet Switch e Panel Mounting Kit e Hardware Installation Guide e Moxa Product Warranty Statement Features High Performance Netw
7. cted to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables Pinouts for the 10 100BaseT X Ports on the TN 5308 PIN TX Housing shield Pinouts for the RJ45 8 pin Port RJ45 8 Pin MDI Port Pinouts MDI X Port Pinouts Pin Signal Pin Signal i 3 1 Tx 1 Rx 2 Tx 2 Rx 3 Rx 3 Tx 6 Rx 6 Tx M12 4 pin M to M12 4 pin M Cross Over Cable Wiring Cross Over Cable Wiring i U E pae ss Rx i 2 2 ERX oo pm e Rx 4 4 Rx M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring D D Straight through Cable Wiring Tx i 1 1 ERX Rx 2 2 TX Tx 3 3 Rx Rx 4 4 Tx M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring Cross Over Cable Wiring Tx 1 1 TX Rx 2 2 Tx Tx 3 3 Rx Rx 4 6 Rx M12 4 pin M to RJ45 8 pin Straight Trough Cable Wiring Straight through Cable Wiring Txt d 1 IR Rx 2 2 Rx TX 3 3 TX Rx 4 6 Tx Auto MDI MDI X Connection The Auto MDI MDI X function allows users to connect TN 5308 s 10 100BaseTX ports to any kind of Ethernet device without needing to pay attention to the type of Ethernet cable being used for the connection This means that you can use either a straight through cable
8. n M12 cable connection is made and then each time a LINK is enabled The TN 5308 advertises its capability for using either 10 Mbps or 100 Mbps transmission speeds with the device at the other end of the cable expected to advertise in the same way Depending on what type of device is connected this will result in agreement to operate at a speed of either 10 Mbps or 100 Mbps If a TN 5308 s Ethernet port is connected to a non negotiating device it will default to 10 Mbps speed and half duplex mode as required by the IEEE 802 3u standard Specifications Technology Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X IEEE 802 3x for Flow Control Processing Type Store and Forward Flow Control TEEE802 3x flow control back pressure flow control Interface M12 Ports 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection LED Indicators PWR 10 100M Power Requirements Input Voltage TN 5308 LV 12 24 36 48 VDC 7 to 60 VDC TN 5308 MV 72 96 110 VDC 50 4 to 154 VDC Input Current TN 5308 LV 0 19A 12 VDC 0 10A 24 VDC 0 054A 48 VDC TN 5308 MV 0 033A 72 VDC 0 024A 96 VDC 0 021A 110 VDC Connection TN 5308 LV M12 A coding 5 pin male connector TN 5308 MV M23 A coding 5 pin male connector Overload Current Present Protection Reverse Polarity recent Protection Physical Characteristics Housing Metal IP40 protection Dimensions W x H x D TN 5308 LV 60 x 216 6 x 3
9. ork Switching Technology e 8 10 100BaseT X ports Store and Forward switching process type IEEE 802 3 802 3u 802 3x e 10 100M Full Half Duplex MDI MDIX auto sensing Industrial Specific Applications Support 12 24 36 48 VDC 7 to 60 VDC power input for LV models e Support 72 96 110 VDC 50 4 to 154 VDC power input for MV models e Active circuit protection Rugged Design e M12 M23 circular connectors for vibration resistant robust connections e Operating temperature range of 0 to 60 C or extended operating temperature range of 40 to 75 C for T models IP40 rugged metal housing Panel mounting or DIN rail mounting installation capability TN 5308 LV Panel Layouts Front Panel View Rear Panel View ou ToughNot Switch suv 9 10 oN 1 TP port s 10 100 Mbps LED 2 10 100BaseT X port female 4 pin shielded M12 connector with D coding 3 Port label 4 Screw holes for panel mounting kit or DIN rail mounting kit there are 3 holes top middle bottom left and bottom right 5 Power input LED 6 Power input port male 5 pin shielded M12 connector with A coding 7 Grounding screw 8 Power input port pin assignment 9 Model name 10 TP port pin assignment 11 Model label TN 5308 MV Panel Layouts Front Panel View Rear Panel View 10 11 TP port s 10 100 Mbps LED 10 100BaseT X port female 4 pin shielded M12 connecto
10. r with D coding Port label Screw holes for panel mounting kit or DIN rail mounting kit there are 3 holes top middle bottom left and bottom right Power input LED Power input port male 5 pin shielded M23 connector with A coding Grounding screw Power input port pin assignment Model name TP port pin assignment Model label 11 Mounting Dimensions unit mm TN 5308 LV 36 4 Das je Ella e 60 ct o cf cf n co 8 e_ 37 Rear View Front View Side View DIN Rail Mounting Kit TN 5308 MV 49 5 0 Hi 128 30 SRE H 6e q OO M o d S PE E Ce p 52 9 Rear View Front View Side View DIN Rail Mounting Kit Panel Wall Mounting Mounting the TN 5308 LV MV on the wall requires 3 screws Please use the 3 screws packed in the panel mounting kit STEP 1 Prepare the 3 screw holes on the wall according to the positions of the 3 screw holes on the switch shown on the mounting dimension diagram STEP 2 Use one screw to go through the top middle screw hole on the switch and screw it into the wall STEP 3 Screw in the remaining 2 screws through the bottom left and bottom right hole
11. s on the switch to the wall NOTE The screw lengths of TN 5308 LV and TN 5308 MV are different TN 5308 LV uses M3 30 mm screws TN 5308 MV uses M3 40 mm screws Please use the screws packed in the panel mounting kit DIN Rail Mounting optional SS With the optional DIN Rail mounting kit JS E S DK TN 5308 must be purchased separately z OV a you can mount the TN 5308 LV MV ona VE a 35mm DIN Rail dl f STEP 1 I5 Fix the DIN Rail attachment plate onto the rear b panel of the switch as shown in the figure at the ol lle right ke Los _ S STEP 2 STEP 3 Position the TN 5308 LV MV on the Swing the switch down fully onto the DIN Rail tilting to hook clamps over DIN Rail until both clamps completely the top edge of the rail latch metal spring 1 DIN Rail To remove the Moxa ToughNet Switch from the DIN Rail simply reverse Steps 2 and 3 above WARNING Turn the power off before disconnecting modules or wires The correct power supply voltage is listed on the product label Check the voltage of your power source to make sure you are using the correct voltage Do NOT use a voltage greater than what is specified on the product label These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006 95 EC and 2004 108 EC ATTENTION Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa
12. vices ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Connecting the Power Supply The M12 M23 A coded 5 pin male connector on the TN 5308 LV MV front panel is used for the DC power input You have to prepare a power cord with M12 M23 A coded 5 pin female connector to connect the switch to the DC power input Pinouts for the power input port on the TN 5308 LV PIN PWR v 3 2 B Nec a 6 v 4 1 Noc B gt 2 N C Not connected Pinouts for the power input port on the TN 5308 MV PIN PWR STEP 1 Plug your power cord connector to the power input port of the TN 5308 switch STEP 2 Screw the nut on your power cord connector to the power input connector on the switch to ensure a tight connection ATTENTION Before connecting the TN 5308 to the DC power input make sure the DC power source voltage is stable Connecting the Data Lines 10 100BaseT X Ethernet Port Connection All TN 5308 models have 8 10 100BaseT X Ethernet ports 4 pin shielded M12 connectors with D coding The 10 100TX ports located on the TN 5308 s front panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type conne