1. mi a gt s J P Raise decorative cover and twist Drop decorative cover ring over light Install switch housing to light kit clockwise until tight kit Install lockwasher and hex nut pro vided and tighten securely a 4a Plug white wire from fan to white Plug connector from fan to connector wire from light kit Then plug blue from switch housing wire from fan to black wire from light kit Install glass to fitters and then install the light rings to hold glass in place gt f Install 3 x 60 watt E12 base bulbs Attach cover of remote by placing Remove cover by snaping off from over buttons and snaping into place top or bottom Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Install wall control unit to outlet box using machine screws provided Attach front cover to wall control with screws provided Fan speed Light dim control but mer for up tons and down lights Fan reverse button To control fan speed select from High Medium or low speed buttons To turn the fan off press the Fan on off button To dim upper lights press and hold U L botton To dim Lower lights press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked REV to reverse the rotation direction of the fan blades Trouble Shooting If you have difficulty operating your new ceiling fan it may be the resul
2. Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control 4 Lh Ole Install remote receiver by sliding into opening in the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig 57 for remote operation Lift canopy to ceiling aligning the key hole slots with the screws on the bottom of the mounting bracket Rotate the canopy counter clockwise to lock in place Tighten the screws to secure the canopy See inset for keyhole shape Place ball on downrod Replace pin removed earlier and pull ball up so that the pin fits in the notches in the ball Raise fan with downrod
3. assembled to the ceiling bracket and hang fan assembly Be sure to rotate the downrod ball so that the notch in the bracket engages the slot in the ball Make wiring connections as indicated above White from fan to white from remote marked N Orange from fan to Orange from remote marked Light up Blue from fan to blue from remote marked down light Black from fan to Black from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Attach blade arms to blades using the blade arm screws and washers provided Attach blades to motor and tighten screws securely using screws washers and motor pads in hardware packs Loosen 3 screws and remove 1 scre on light plate as shown Save screw Install nut to all thread into switch housing Install finial cap and finial nut onto switch housing Twist lower cover plate into place by twisting in direction of arrow Replace 1 screw removed and tighten all 3 screws securely Loosen 2 screws and remove 1 screw Save screw removed N a Remove plug from switch housing Install all thread into switch housing B x Site Install lockwasher and hex nut pro Remove finial nut and finial cap from vided and tighten securely light kit Plug connector from fan to connector from switch housing Tighten switch housing screws N J
4. before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can
5. choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING Risk of fire electric shock or personal injury The fan in this box may be either directly supported from a structural framing member of a building and or may be mounted to an outlet box marked acceptable for fan support of 31 8 kg 70 lbs or less Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHR
6. holes on the outlet box Use only the appropri ate wood screws and washers included with your fan Caution Wood screws must go through into the building joist Step Ladder Remove Safety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws 6 FAN BRACE AND BOX METHOD Install the mounting Plate to approved fan brace and box combination use only the hard ware provided with the fan brace and box Lift mounting neck to mounting Plate and align Secure mounting neck to the mounting plate Loosen set screws that holds ball screws with four screws to become a complete mount k ing bracket Pinsen Loosen lock nuts and screws on K f till you can not feel screw on insi Remove keeper from cross pin and of yoke then cross pin from yoke Replace keeper on cross pin and save Align hole in downrod with hole in Tighten 2 downrod set screws and yoke and install cross pin Install lock nuts downrod into yoke Install keeper into cross pin Place glass into cage on fan body Install 4 x 15 watt incandescent can INSE TOR cover over downrod onto delabra bulbs an Doay i Tighten set screws to hold ball in place Safety cable installation p Poe lock screw washer Fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cable must be installed into the house struc ture beams using the 3 lag screws washers and lock washers provided
7. AE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such asa tag to the service panel Remove the 4 screws attaching the Mounting neck the mounting plate Retain the 4 screws for re assembly Wire Cutters TOOLS REQUIRED Pliers OUTLET BOX METHOD Warning Risk of fire electric shock or person al injury The fan in this box may be either directly supported from a structural framing member of a building and or may be mounted to an outlet box marked acceptable for fan sup port of of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of lummi naires may not be acceptable for fan support and may need to be replaced Consult a quali fied electrician if in doubt BUILDING STRUCTURE METHOD Mounting ba f Outlet box Pa Plate E Wo Wood Secure mounting plate directly to a joist from the buliding structure via the two knock out
8. Owner s Manual Ceiling Fan Installation Instructions Total fan weigh with light For 5SCR60BR3 Fan READ AND SAVE THESE INSTRUCTIONS MONTE CARLO o Quality Ceiling fans LISTED WN Now Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJ URY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacurer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you
9. redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing WARNI NG Before attempting to replace the fuse make sure the main power is turned off to the fan Replace only with 3 amp fuse Fuse is in canopy MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092 6 21 06 REV 0O New made from 5GMR manual
10. t of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag Trouble 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work to the service panel Suggested Remedy 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off
Download Pdf Manuals
Related Search
Related Contents
TEMPORIZADORES ELETRÔNICOS CÍCLICOS REF description 334459 999001 2 9 Colonne en Alu HR-6800 Manual de usuario balanzas portátiles modelos JCM TERK Technologies LF-UNIV User's Manual SIKA® 2 - Materiales Jerez Hunter 54068 Installation Guide TRS213[14.12] S1.0E, S1.0, S1.2, S1.4, S1.4il, S1.6, S1.6il Trendnet TV-IP672PI surveillance camera Copyright © All rights reserved.