image

Contents

1. box and ungrounded conductor on the other side of the outlet box Raise canopy up and align t the canopy with the two holes in the hanger bracket Secure with two screws provided Check the motor for plastic shipping stabilizer tabs and remove them if they are present Attach blade assembly to motor using the motor screws and washers provided Tighten screws securely Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mounting bracket This will allow hands free wiring Fan Black Black 0o En c77 Blue White ___ White Green _ EL NNN XXXF gt Green downrod ct YYYYYI Green Bracket For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may vary in color and may not include ground wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips Place shim on blade Place blade onto blade holder After installation of all blades you must replace the rubber grommet to ensure no water leak age through to switch housing Safety cable installation Safety Cable rere 4 y i 3 lag screw safety cable F EA flat washer lock washer For Canadian installation and for USA fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cabl
2. you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade 8 To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 9 Donot bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box 11 To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control 12 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application 13 NEVER place a switch where it can be reached from a tub or shower 14 The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 15 Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being Switched on accidentally When the service disconnecting mea
3. Owner s Mehri Ceiling Fan Installation Instructions Total fan weight For 5PE56 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO JR IL Quality Ceiling fans S Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS 1 Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer 3 After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 4 Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being Switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 5 Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 7 Make sure the installation site
4. e must be installed into the house structure beams using the 3 lag screws provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires Light Switch Fan Switch t Wall oo J Control For control of fan and optional light from wall location follow diagram above NOTE A profes sional electrician is recommended for this type of installation Install 3 screws and washers per blade and tighten securely Repeat for all 5 blades Install switch cap into switch plate housing align the 3 holes and install 3 screws and tighten securely Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag 1 If fan does not start 2 If fan sounds noisy 3 If
5. easure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make Sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
6. fan wobbles 4 If light does not work to the service panel 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping m
7. ns cannot be locked securely fasten a prominent warning device such as a tag to the service panel Note For Outdoor Fans Only Suitable for use in wet locations when installed in a GFCI protected branch circuit Use only with light kits marked suitable for use in wet locations TOOLS REQUIRED Phillips Screwdriver Wire Cutters Pliers Step Ladder Install the Mountiing Bracket to the Outlet box Before you begin installing the fan Switch power off Before installing this fan make sure the outlet Use only the screws provided with the out at Service panel and lock service disconnecting means box is properly installed to the house structure to prevent power from being switched on accidentally To reduce the risk of fire electric shock or per When the service disconnecting means cannot be sonal injury mount to outlet box or supporting locked securely fasten a prominent warning device system acceptable for fan support such as a tag to the service panel Mounting must support at least 35 Ibs rod yoke cover assembled clevis pin through yoke and downrod and secure with cotter pin see inset f ST Tighten both yoke set screws to further secure downrod Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet

Download Pdf Manuals

image

Related Search

Related Contents

Manual Fluke 1630  User Manual - Western Avionics Ltd  。 取扱説明書をご熟読のうえ、正しく安全にお使いください。 ご  USER MANUAL High Definition HDD Multimedia Player    Craftsman 18 Volt Replacement Battery for String Trimmer 071-74815 Manufacturer's Warranty  特集3 信頼性の高い製品/サービスの提供  NP2900 Swedish user manual  Fisher-Price K4563 Instruction Sheet  