Home

Monte Carlo Fan Company 5CLR66XXD Series User's Manual

image

Contents

1. Use only the appropri ate wood screws and washers included with your fan Caution Wood screws must go through into the building joist Step Ladder Remove Safety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws Install the mounting Plate to approved fan brace and box combination use only the hard ware provided with the fan brace and box Lift mounting neck to mounting Plate and align Secure mounting neck to the mounting plate screws with four screws to become a complete mount ing bracket Loosen lock nuts and screws on yoke till you can not feel screw on inside of yoke Install downrod into yoke Align hole Thread leadwires and safety cable in downrod with hole in yoke and through downrod install cross pin Install keeper into cross pin AN Install yoke cover over downrod onto fan body Remove keeper from cross pin and then cross pin from yoke Replace keeper on cross pin and save Slide ball down and remove pin save pin for later Tighten 2 downrod set screws and lock nuts Tighten screw on arch hub into downrod to hold in place Tighten set screw to hold ball in place See Raise fan with downrod assembled to the ceiling bracket and hang fan assembly Be sure to rotate the downrod ball so that the notch in the bracket engages the slot in the ball House Make wiring connections as indicated above White from fan to white from remo
2. ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such asa tag to the service panel Remove the 4 screws attaching the Mounting neck the mounting plate Retain the 4 screws for re assembly Wire Cutters TOOLS REQUIRED Pliers OUTLET BOX METHOD Warning Risk of fire electric shock or person al injury The fan in this box may be either directly supported from a structural framing member of a building and or may be mounted to an outlet box marked acceptable for fan sup port of of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of lummi naires may not be acceptable for fan support and may need to be replaced Consult a quali fied electrician if in doubt BUILDING STRUCTURE METHOD Mounting Toute box peel Plate Secure mounting plate directly to a joist from the buliding structure via the two knock out holes on the outlet box
3. Owner s Manual Ceiling Fan Installation Instructions Total fan weigh with light For 5CLR66XXD Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO o Quality Ceiling fans LISTED WN Nau Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJ URY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacurer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation s
4. eight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 1 800 519 4092 6 21 06 REV 0O New made from 5GMR manual
5. g into place Twist lower cover plate into place by twisting in direction of arrow Replace 1 screw removed and tighten all 3 screws securely Place light kit over screws and twist direction of arrow into place Then tighten all 3 screws securely Install cage and finial cap and tight en in direction of arrow Install wall control unit to outlet box using machine screws provided MONTE CARLO Remote Control Transmitter Features Attach front cover to wall control with screws provided Snap battery cover in place FAN REVERSE LED LIGHT Press once to change direction of MEDIUM SPEED the fan Fanmust be running to reverse LOW SPEED HIGH SPEED FAN OFF SETTING ET Turns fan off only LIGHT ON OFF S TING AND DIMMER Press and hold to dim light infinitively FAN SPEED Depress I dot for low speed 2 dots for medium or 3 dots for high To turn fan off press square LIGHT DIMMER To turn light on press light dimmer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect as
6. ite you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING Risk of fire electric shock or personal injury The fan in this box may be either directly supported from a structural framing member of a building and or may be mounted to an outlet box marked acceptable for fan support of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers
7. oth receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control Mf Install remote receiver the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig 44 for remote operation Lift canopy to ceiling aligning the key hole slots with the screws on the bottom of the mounting bracket Rotate the canopy counter clockwise to lock in place Tighten the screws to secure the canopy See inset for keyhole shape plate with castings on motor to attach blades to motor Loosen 3 screws on light plate as shown Install 3 x 60 watt candelabra bulbs Bulbs not included Remove cover by snaping off from top or bot tom Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach cover of remote by plac ing over buttons and snap the battery cover in place Loosen 2 screws and remove 1 screw Save screw removed Plug white wire from fan to white wire from light kit Then plug black wire from fan to black wire from light kit Install glass onto light kit install rubber washer on the top side of the screw nut to hold in place and tight en in direction of arrow Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snapin
8. sembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty jin installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag Trouble 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work to the service panel Suggested Remedy 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering s
9. te marked N Blue from fan to blue from remote marked light Black from fan to Black from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Thread leadwires and safet through ball Tighten set screw to hold ball in place Safety cable installation Fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cable must be installed into the house struc ture beams using the 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Ape F 2 v Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Place ball on downrod Replace pin removed earlier and pull ball up so that the pin fits in the notches in the ball Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting b
10. witch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the w

Download Pdf Manuals

image

Related Search

Related Contents

2016 Whyte MTB Full Suspension Supplementary Service Manual  Tefal Express Anti-Calc  sweeper sr 1100 p/b sr 1200 p/b sr 5110 p/b sr 5120  1 - Access  6号圧力釜を安全にお取り扱いいただくために    REPARATURANLEITUNG FK96, FK96/4, PFK96, PFK96/4  diesis utente  

Copyright © All rights reserved.
Failed to retrieve file