1. Install wall control unit to outlet box using machine screws provided Reverse function for this fan is a switch on top housing of the fan body Turn fan off and flip switch this will reverse the direction of the blades TROUBLE SHOOTING If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 1 If fan does not start 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from transmitter and receiver are set on the same frequen cy CAUTION Make sure main power is turned off 4 Make sure forward reverse switch is firmly in up or down position Fan will not operate when switch is in the middle 2 If fan sounds noisy 1 Check to m
2. balancing or during cleaning Do not insert foreign object between rotating To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 1 including fire rated construction 2 ce ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 4 such as a tag to the service panel Da 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities J feet from the floor to the trailing edge of the blade 8 Use only the screws provided with the outlet box Mounting must support at least 35 Ibs 9 blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box 11 12 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application 13 NEVER place a switch where it can be reached from a tub or shower 14 15 Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to p
3. cable through downrod As Safety cable installation a ee a For Canadian installation and for USA fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the lead wires while black reer ee el a Make wiring connections as indicated above White from fan to white from remote marked N Blue from fan to blue from remote marked light Black from fan to Black from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Insert downrod into yoke on top of the Fan Body Align the hole in the Downrod with the hole in the Yoke Insert the Pin through the Yoke and Downrod until the point appears on the other side Install the keeper to pin Make sure the studs protruding from the bottom of the Mount
4. locating dimples in light fixture with the groves in glass and twisting clockwise till tight Install light plate by twisting plate with key hole slots into place Attach blanking plate to fan by twist ing into place Attach decorative cap to light fixture by twisting into place Pass leadwires and safety cable through the canopy 21 EE lt Replace screw removed and tighten the 3 screws securely Connect white wire from fan to white wire from light fixture Then plug black wire from fan to black wire from light fixture Install 1 x 100 halogen bulb E 11 Do not touch bulb surface as oily residue from skin can cause the bulb to explode exposing 4 holes 2 closed holes and 2 open L shape holes Remove 2 screws in yoke and keeper then cross pin see insert Remove 3 screws with keyhole slots from top of Hang fan from mounting bracket by the hands free hook into a closed hole on the edge of the Canopy Note For Canadian mounting refer to Step 10 Slide remote receiver into mounting bracket Align the blade and then the blade plate with castings on motor to attach blades to motor i E Place canopy on top of the fan motor allowing the yoke wires and safety cable to pass through the large hole in the center of the canopy Align the 3 larger holes around the center hole with the 3 screws still installed in the fan Install 3 screws removed into small holes in canopy to make it a flush
5. mount canopy and tighten screws securely Whibe black ireen Make wiring connections as indicated above White from fan to white from remote marked N Blue from fan to blue from remote marked light Black from fan to Black from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box remove 1 screw without slot from motor plate and save screw Install two screws corresponding with the L shaped holes in the canopy only part way so that canopy can twist into place Remove the all thread studs from the lower part of the mounting bracket Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate propery If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control Lift fan to mounti
6. OWNER S MANUAL Ceiling Fan Installation Instructions Total fan weight with light ee For 3ASR52XXD Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO LISTED QUALITY CEILING FANS Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes ANSI NFPA 70 1999 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding con Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Do not bend blade holders during installation to motor
7. ake sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 3 If fan wobbles 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied betw
8. een the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the posi tion of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistrib ute the weight and possibly result in smoother operation 4 If light does not work 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing or canopy WARNING Before attempting to replace the fuse make sure the main power is turned off to the fan Replace only with 3 amp fuse The fuse is inside the canopy Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
9. ing bracket are installed with threads all the way through the bracket Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate propery If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control Next lift the cover ring and install knurled nuts as shown Tighten the knurled nuts securely The canopy should adjust for ay irregularity in the ceiling or Outlet Ox Tighten the 2 set screws on the Yoke once the downrod is in place Hang assembled fan from the mounting bracket installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion Slide remote receiver into mounting bracket Align the blade and then the blade plate with castings on motor to attach blades to motor SS Loosen 2 screws with key slots and remove 1 screw without slot from motor plate and save screw Install light plate over all thread and use nut provided to secure in place Install light fixture over all thread and use nut provided to secure in place ae Attach glass by
10. ng bracket aligning the L shape holes with the scresws on the mount ing bracket Turn the fan clockwise to lock in position Install the other two screws and tighten securely Install light plate by twisting plate with key hole slots into place Replace screw removed and tighten the 3 screws securely Attach decorative cap to light fixture by twisting into place Remove cover by snapping off from top or bottom Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V a Attach front cover to wall control with screws provided Connect white wire from fan to white wire from light fixture Then plug black wire from fan to black wire from light fixture Install 1 x 100 halogen bulb E 11 Do not touch bulb surface as oily residue from skin can cause the bulb to explode Attach cover of remote by placing over buttons and snapping into place Fan speed Light dimmer trol i for ligh sone ae ils Fan on off To control fan speed select from nig medium or low speed buttons To turn the fan off press the Fan on off button To dim lights press and hold light but ton To turn off light press and quickly release button Install light fixture over all thread and use nut provided to secure in place r _ Attach glass by locating dimples in light fixture with the groves in glass and twisting clockwise till tight
11. revent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel For downrod mount go to step 5 For flush mount go to step 29 TOOLS REQUIRED Wire Cutters Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs F e i sl emove keeper from pin Replace keeper into pin and save for later Pliers Step Ladder Use metal outlet box suitable for fan support must support 35 Ibs Before attaching fan to outlet box ensure the outlet box is securley fastened by at least two points to a structural ceiling member a loose box will cause the fan to wabble Use only the screws provided with the outlet box Loosen the 2 set screws in yoke for downrod to slip into yoke Place canopy canopy ring and then yoke cover on downrod Thread leadwires and safety