1. Check Filter Display Humidistat The humidistat located on the power cord senses the percentage of humidity in the air It causes the humidifier to cycle on and off to maintain the selected humidity SET point The fan will turn on if the ROOM reading falls 3 below the SET point and will continue to run the humidifier until a reading of 1 above the SET point is achieved The fan will turn off until the ROOM reading falls 3 below the SET point again NOTE Be sure humidistat which is located on the power cord is free from obstructions and is away from any hot air source QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 11 Replacement and Care of Filters WARNING To reduce the risk of shock or injury from moving parts always unplug humidifier before removing or replacing any parts CAUTION To help retard bacteria growth and keep maximum efficiency the filter should be replaced at least once per season or more often under hard water conditions Use MoistAIR HDC 12 recommended replacement filter The filters may be rinsed periodically in clear water only Take care not to damage paper To replace evaporative wicking filters in your humidifier follow these instructions 1 Unplug humidifier before removing the filters We recommend moving the humidifier to an area where floor coverings are not susceptible to water damage i e kitchen or bath areas Open the pivoting lid and remove water bot
2. If you hear air bubbles or see leaks retighten the Side Fill Cap and repeat Steps 1 4 Wipe off excess water from the bottle Raised Section Position the water bottle back into the unit by grasping the water bottle handle and lower it into the cabinet until the bottle sits on pads at bottom of cabinet The Side Fill Cap must be facing the rear of the cabinet When positioned properly the plunger will open and water will flow into the cabinet The water level will automatically remain at approximately 1 2 until the bottles are empty Allow the filter to saturate for 30 minutes before Pivoting Lid Removed for Clarity operation QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 8 Operating the Controls Where you set your desired humidity levels depends on your personal comfort level outside temperature and inside temperature A starting set point of 30 40 ROOM humidity is recommended but there may be conditions that require a different setting IMPORTANT Water damage may result if condensation starts to form on windows or walls Humidity SET point should be lowered until condensation no longer forms We recommend room humidity levels do not exceed 50 When Outdoor Temperature is Recommended Indoor Relative Humidity is and above To Operate the Controls Digital Display Press the power speed button once to turn the unit on Initially there is a slight delay while the
3. Position them in the correct location so the humidifier can function properly The water bottles should rest in the front of the cabinet Each Side Fill Cap must be facing the rear of the unit If the plug does not fit fully in the outlet reverse plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way Fan Assembly m Pivoting Lid Bottles Rear of Humidifier Side Fill Cap Should Always Face Rear a QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 7 Water Fill continued Each water bottle is designed with a Side Fill Turn Counterclockwise Cap that is easily removable Remove the Side to Remove Cap Fill Cap on the side of the water bottle by twisting counterclockwise Place the opening of the water bottle under a water faucet the bottle should fit under a four inch clearance faucet Fill with recommended mixture of cold water and Bacteriostat if necessary only Solid debris could make the valve leak Install the Side Fill Cap by twisting clockwise Valve Cap Hand tighten only Plunger Check for possible leaks by performing the following 1 Grasp bottle handle and hold the bottle upright over a sink 2 Press up on the valve cap plunger for about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around the Side Fill Cap 5
4. Kick STD601107 Screw Pan Hd Ty AB 10 x 3 4 828515 Caster Twin Wheel 830560 1 Support Filter Lower HDC12 Filter Evaporative 828534 Support Motor 828115 1 Motor 822406 1 Fan 828197 Support Upper Filter 824101 Retainer Float 828200 3 Float Water Level 828920 Pad Caster Two SP6647 Operator s Manual not illustrated CO CO NI a oc BY cw PM gt 4 x x x x x x x x x CO OO CO NI GD AJ wy P N 87 NOTE Any attempt to repair the control assembly or motor may create a hazard unless repair is done by a qualified service technician Standard Hardware Item May be purchased locally Stock item Purchase locally or call numbers below To order parts call USA 1 800 547 3888 Canada 1 888 744 4687 QUARKSP6647 HD14070 SP6647 qxd agn 3 39 PM Page 17 Warranty Moist AIR PRODUCTS HUMIDIFIER WARRANTY POLICY EFFECTIVE APRIL 1 2008 SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS This product is warranted against defects in workmanship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to filters or wicks which are customer replaceable parts This warranty applies only to the original purchaser of the product when it is purchased from a reputable retailer dealer This warranty does not ap
5. a level surface Float will not sense water at the front of the cabinet Position unit level Some carpet padding may allow unit to sit lower in the front than rear with the additional weight of water bottles in the front of the cabinet Install caster pads under front casters see page 5 Display blinks or fan moves slightly when humidifier is plugged in Normal No action required Alternating F and room humidity displayed Reservoir is empty Fill humidifier with water Alternating CF and room humidity displayed Filter may be dirty CAUTION Use only EPA Registered Bacteriostat Use of other water treatment products may damage the filter elements Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers 14 Replace filter QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 15 Repair Parts Parts List for MoistAIR Humidifier Model No HD14070 QUARKSP6647 HD14070 SP6647 qxd agn 3 39 PM Page 16 Repair Parts Parts List for MoistAIR Humidifier Model No HD14070 Always order by part number Not by key number Za og Part No Description 828741 2 Lid Stationary 828855 2 Lid Pivoting 831680 1 Control Assembly 824690 Side Fill Cap 828192 Bottle Left Includes Key Nos 4 amp 7 828726 Bottle Right Includes Key Nos 4 amp 7 509229 1 Cap Valve Assembly 828199 10 Cabinet 823726 Rail
6. electronics calibrate Two bars appear during this time Once calibration is complete a ROOM humidity reading between 20 95 will be displayed A flashing 20 display indicates that the room humidity is less than 20 NOTE The default settings at initial startup are Ultra Quiet F1 fan speed and 65 SET humidity After desired settings are selected by the user they remain as long as the unit remains plugged in and there is no power interruption If the unit is unplugged the original default settings are employed Humidifier fan should operate at initial start up If it does not refer to Fan not operating digital display is illuminated in the Trouble Shooting section on page 14 Function Buttons Digital Display Speed Button This humidifier is equipped with a 3 speed fan control Initially depressing the speed button will display the current speed setting Each push of the speed button advances the mode through the settings of HIGH F3 MEDIUM F2 and Ultra Quiet F1 The selected setting is displayed on the digital readout The higher the setting the faster water is evaporated and released into the air F1 Ultra Quiet is the quietest setting and is provided for conditions that do not require a rapid evaporation rate Speed Button Moist AIR Humidity Control This button allows you to adjust the humidity to suit your needs This humidifier will automatically cycle o
7. for instructions Remove the packaging material from inside your humidifier and follow the instructions of this operator s manual for proper usage The packaging material is located under the fan assembly Remove the packaging material and discard QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 5 Location Instructions WARNING For your own safety do not use humidifier if any parts are damaged or missing Step 1 Place humidifier on a flat level surface in an area of your house where humidity is needed most or in an area which would likely result in moist air being circulated throughout the house such as near a cold air return Placing the unit level is very important if the humidifier is located on carpeting NOTE The humidifier contains water bottles The weight of the bottles in the front of the cabinet may cause the front casters to sink deeper into the carpet If this happens the water level will be higher towards the front of the humidifier and lower towards the back The water level float located at the rear of the cabinet may not sense the water so the flashing F will be displayed and the unit will not energize If this happens the unit will need to be leveled in order for the humidifier to be energized To level the humidifier when located on carpet place the included caster pads under the front two casters of the humidifier only NOTE Due to release of cool moist air from humidifier
8. risk of electrical hazard or damage to humidifier do not tilt jolt or tip humidifier while unit is running 9 To reduce the risk of damage to humidifier unplug when not in use 10 To reduce the risk of accidental electrical shock do not touch the cord or controls with wet hands 11 To reduce the risk of fire do not use near an open flame such as a candle or other flame source 12 Note the warning label shown below WARNING To reduce risk of fire electric shock or injury always unplug before servicing or cleaning QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 3 Know Your Humidifier Controls Filters Replacement Filter HDC12 Humidistat On Power Cord Description Output 24 hrs Capacity of Bottle Sq Ft Coverage Fan Speeds Auto Fan Speed Replacement Filter Refill Indicator Auto Shut Off Auto Humidistat Controls Control Lock Casters ETL Listed Volts Hertz Amps Watts Fan Assembly Bottles Pivoting Lid Casters Pivoting Lid Removed For Clarity HD14070 14 Gallons 53 Litres 2 3 8 Gallons 9 Litres 2900 3 Yes Set of 4 HDC12 Yes Yes Yes Electronic Push Button Yes Yes 4 Yes 120 A C 60 2 88 165 Based on an area with average insulation and an 8 ceiling height ANSI AHAM HU 1 1997 SEC 8 1 results may vary a QUARKSP6647 HD14070 SP6647 qxd ragg 3 39 PM Page 4 How Your Humidifier Works Your new MoistAIR humidifier is des
9. QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 1 CAUTION READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION SAVE THIS OWNER S MANUAL FOR FUTURE REFERENCE Model No HD14070 WY KY 4 ae HD14070 Evaporative Console Humidifier Owner s Manual Part No SP6647 12 09 Printed in U S A a QUARKSP6647 HD14070 SP6647 qxd agn 3 39 PM Page 2 GENERAL SAFETY INSTRUCTIONS Safety Signal Words DANGER means if the safety information is not followed someone will be seriously injured or killed WARNING means if the safety information is not followed someone could be seriously injured or killed CAUTION means if the safety information is not followed someone may be injured 1 To reduce the risk of fire or shock hazard plug humidifier directly into a 120V A C electrical outlet Do not use extension cords 2 Keep the electric cord out of traffic areas To reduce the risk of fire hazard never put the electric cord under rugs near heat registers radiators stoves or heaters 3 Always unplug the humidifier before moving it removing the fan assembly section before cleaning or whenever the humidifier is not in service 4 Keep the humidifier clean 5 Do not put foreign objects inside the humidifier 6 Do not allow to be used as a toy Close attention is necessary when used by or near children 7 Never use your humidifier while any part is missing or damaged in any manner 8 To reduce the
10. ed The manufacturer will repair or replace the product at its discretion at no charge to the customer with return freight paid by the manufacturer It is agreed that such repair or replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES This warranty will be null amp void if purchaser attempts to repair or replace any parts which are mechanical or electrical The warranty gives the customer specific legal rights and the customer may also have other rights which vary from province to province or state to state QUARKSP6647 HD14070 SP6647 qxd ragg 3 39 PM Page 18 FOR TECHNICAL HELP CALL 800 547 3888 FROM USA OR 888 744 4687 FROM CANADA Please have complete model number Moist AIR ame Essick Air Products For more information about MoistAIR humidifiers visit our website at www moistair com 2009 Part No SP6647 Form No SP6647 1 Printed inU S A 12 09 n
11. igned to satisfy home humidity requirements through the principle of evaporation of water into the air After water is added to the bottle the filters begin rah ko to soak up the water and become totally saturated Through in approxi mately 30 minutes Air is drawn in from the Rear Humidified Air is Then Released Through the Top ELEERI the rear of the humidifier and through the filters by means of circulation fans As air passes through the filters moisture is absorbed into the air and then released in the form of vapor No water droplets will enter the home All evaporation into the air takes place in the humidifier which means that the residue left by evaporating water is not passed into the home but remains in the filter CAUTION Use only EPA Registered Bacteriostat Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers CAUTION To reduce the risk of injury fire or damage to humidifier use only cleaners specifically recommended for humidifiers Never use flammable combustible or poisonous materials to clean your humidifier To reduce the risk of scalds and damage to humidifier never put hot water in humidifier Assembly Your new MoistAIR humidifier is completely assembled for you to use Remove the bag pack containing two plastic caster pads from top of humidifier and retain for future use if required See the following Step 1
12. it is best to direct air away from home thermostat and hot air registers It is best to position humidifier next to an inside wall Hot air registers and cold air from outside walls can affect the efficiencies of the controls Unit should not be placed where warm air from a hot air register blows directly on unit Operating Tips for Best Performance 1 Position the humidifier at least 2 inches 5 cm from any wall and away from any heat registers 2 Do not restrict airflow from entering or exiting the humidifier 3 Use only EPA registered bacteriostat to retard bacteria growth that may cause odors and may be harmful to your health Moist air humidity produced will disperse into the whole house but area closest to the unit will have the highest humidity If the unit is positioned close to a window condensation may form on the window pane If this is not appropriate the unit should be repositioned in another location Step 2 The humidifier should be positioned with the back cord exit side at least 5 centimeters away from the wall Air needs to enter through the louvers in the rear panel in order for the humidifier to operate at peak efficiency At Least 2 5 cm From Wall Front of Cabinet Front Caster F lt Caster Pad ME Carpet Surface NOTE If positioning on carpet place caster pads under front casters only to level if necessary 4 Perform regular cleaning as instructed in Cleaning a
13. n and off as required to maintain the selected setting The readout displays both actual ROOM and desired SET humidity percentage settings when humidity control button is pressed The ROOM readout has a range of 20 to 95 If the room humidity level is equal to or less than 20 the display will show a flashing 20 a QUARKSP6647 HD14070 SP6647 qxd ragg 3 39 PM Page 9 Operating the Controls continued The SET readout has a range of 25 to 65 and is adjusted in increments of 5 Initially depressing the humidity button will display the current humidity setting Each additional press of the button increases the setting by 5 A SET point of 65 operates the humidifier continuously regardless of the ROOM reading The humidistat that senses the readings is located on the power cord Insure that this humidistat is free from obstruction Humidity Button Using Your Humidifier Refill Display Function To do this simply slide the float retainer located at the back of the humidifier cabinet to the top position of the slot it is located in This will hold the float in an upward position and the fan will run until you turn the power off For maximum run time both bottles should be filled When both bottles are empty the display alternates the room humidity reading and F FILL informing additional water is required NOTE Be sure to position float retainer to the normal operating mode lowest position in slot for no
14. nd Maintenance section of this manual 5 Replace the evaporative wicking filters at least once per humidification season or more depending on water conditions in your area QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 6 Electrical Hook Up Locate nearest 120V A C wall socket in the location desired preferably on inside wall With the humidifier in the desired location route the electrical cord safely so no one will trip or upset the humidifier Plug in the electrical cord WARNING To reduce the risk of fire or shock hazard humidifier should be plugged into a 120V A C outlet Do not use extension cords To reduce the risk of electrical shock this humidifier has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way Water Fill WARNING To reduce the risk of shock always unplug humidifier before cleaning or servicing WARNING To reduce the risk of fire or shock hazard do not pour or spill water into control or motor area If controls get wet let them dry completely and have unit checked by authorized service personnel before plugging in This humidifier is designed for use with the two water bottles that are located under the pivoting lid Open the pivoting lid of the humidifier Remove the water bottles by lifting them straight up and out of the cabinet Notice the water bottles are designed as right and left hand units
15. nuously unit will not shut off ROOM humidity level is not 3 or more below SET humidity level Reservoir is empty Float is obstructed SET humidity level is 65 ROOM humidity level has not reached 1 or more above SET humidity level Raise SET humidity level if desired Increase fan speed Fill humidifier with water Free float from obstruction ASET humidity percentage of 65 operates fan continuously Adjust SET level between 25 60 Continue to run until desired humidity level is achieved This may take up to 48 hours initially Poor evaporation of water e Check filter message CF is flashing e Mineral buildup on filter Change to a fresh new filter NOTE Local water purity varies from area to area Neither bottle emptying Bottle cap plunger missing post in bottom of cabinet Dirty filters Check orientation of bottles Reposition so that bottle cap plunger stem is depressed by post in bottom of cabinet Change to fresh new filters HDC12 Bottles continues to empty Air is entering water bottle Check Side Fill Caps and valve assembly caps to ensure tightness Check for leak in water bottle Ensure gaskets for Side Fill Caps are in place Left bottle not emptying Right bottle contains water The humidifier is designed so that right bottle empties first Refill display F is on before bottles are empty Unit is not set up on
16. on the filter housings correctly Be sure that the spring tabs of filter housings are towards front of cabinet Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabinet f Position fan assembly onto the cabinet Make sure the fan venturi lowest cylinder section below the fan is placed inside the filter housing Replace water bottles Close the pivoting lid i The unit is ready for use or to be stored away for next season Cleaning and Maintenance WARNING To reduce the risk of injury fire or damage to humidifier use only cleaners specifically recommended for humidifiers Never use flammable combustible or poisonous materials to clean your humidifier To reduce the risk of scalds and damage to humidifier never put hot water in humidifier CAUTION Local water purity varies from area to area and under certain conditions water impurities and airborne bacteria may promote the growth of micro organisms in the reservoir of the humidifier To retard bacteria growth that may cause odors and be harmful to your health use only MoistAIR replacement filters We also recommend using EPA approved bacteriostat and humidifier cleaner 12 Spring Tabs Flat Portion of Filter Housing Towards Back of Cabinet Spring Tabs Towards Front of Cabinet Step 4e NOTE If it is necessary to use approved bacteriostat follow directions correc
17. ply to damage from accident misuse alterations unauthorized repairs unauthorized use mishandling unreasonable use abuse including failure to perform reasonable maintenance normal wear and tear nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipment or products being improperly installed or wired or maintained in violation of this Owner s Manual Alterations include the substitution of name brand components including but not limited to wicks and bacteria treatment THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE PRODUCTS AND TO THE MAXIMUM EXTENT PERMITTED BY LAW IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS EXPRESS OR IMPLIED ARISING BY OPERATION OF LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR PURPOSE No employee agent dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs Within the limitations of this warranty purchaser with inoperative units should contact customer service 800 547 3888 for paperwork and instructions on the return of the unit for repair A copy of the sales receipt is required before authorization to return a unit for repair is approv
18. rmal humidifier operation Below is a diagram of the slot the float retainer is located in at the back of the cabinet Refill Display Top Position Back of Cabinet is for Manual Cae ie T m Dryout Manual Dry Out i il Hill Bottom Position gig ys F is for Normal At the end of the humidification season or if you do Hen Operation Mode not plan to run the humidifier for one week or ily more a manual dry out mechanism is provided to completely dry out the humidifier cabinet ia Fici Retainer Slot QUARKSP6647 HD14070 SP6647 qxd rages 3 39 PM Page 10 Using Your Humidifier continued Check Filter Indicator The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the filter As the filter loads with impurities it gradually loses its wicking capability When this happens moisture output is reduced and the humidifier has to work longer to satisfy the selected setting This humidifier has a check filter reminder timed to appear after 720 hours of motor operation When the display shows an alternating CF and room humidity setting at 5 second intervals it is a reminder to check the filter condition NOTE Some areas have high water mineral content causing the need for more frequent filter changes Refer to Replacement and Care of Filter on page 11 If a build up of deposits or severe discoloration is evident replace the filter to restore maximum efficiency
19. soft cloth with undiluted white vinegar and wipe out reservoir to remove scale Rinse thoroughly with clean warm water to remove scale and cleaning solution before disinfecting the reservoir Disinfecting Humidifier Cabinet and Water Bottles 1 Fill humidifier cabinet with 1 teaspoon 5 ml chlorine bleach in 1 gallon 3 8 litres of water Let solution stay for 20 minutes carefully swishing every few minutes Wet all surfaces normally exposed to water Empty humidifier cabinet after 20 minutes Rinse with water until bleach smell is gone Allow unit to dry out completely Water bottles should be cleaned in the same manner End of Season Maintenance 1 Follow Bi Weekly Maintenance instructions at end of humidification season Remove and throw away filters Let humidifier dry completely before storing Do not store with water inside cabinet or water bottles Store in cool dry location Install a new filters in clean humidifier before next season begins Bi Weekly Maintenance procedure is also recommended if you do not plan to run the humidifier for one week or more 2 3 QUARKSP6647 HD14070 SP6647 qxd agn 3 39 PM Page 14 Troubleshooting Trouble Digital display not illuminated Probable Cause No Power Power button has not been depressed Check 120 volt power source Press power button once to turn on Fan not operating digital display is illuminated Fan running conti
20. the humidifier cabinet by pinching the float retainer to release it from the cabinet The cabinet should be empty before cleaning The cabinet consists of the lower areas of the humidifier where the filters are during normal operation time Empty cabinet of any remaining water e Proceed to Bi Weekly Maintenance or End of Season Maintenance f Remove old filters and dispose of properly as described on pages 11 12 Step 3 Install new filters purchase the correct evaporative wicking filter pads HDC12 for your humidifier into the location where the old filters were positioned Install the filter housings with the new filters into the correct location Reinstall the water level float NOTE Float retainer should be positioned in normal operating mode Assure that it is positioned in the bottom of the slot in the back of the cabinet See page 9 for diagram of slot Position the fan assembly on top of the cabinet and return the humidifier to the desired location for use Refill humidifier bottles with fresh cool water and return them to the cabinet Plug the unit into a 120 volt A C power outlet and set the controls per the Operating Humidifier Controls section page 8 of this manual Bi Weekly Maintenance Removing Scale 1 Fill the reservoir with water and add one 8 oz 236 ml cup of undiluted white vinegar Let solution stay for 20 minutes Clean all interior surfaces with soft brush Dampen
21. tles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a Clean flat surface The filter housings are now accessible Lift filter housing out of cabinet and place where you may work on them comfortably With a soft absorbent cloth remove any remaining water or loose mineral deposits not trapped in the filter from the humidifier cabinet To open filter housing for easy access to filters Deflect the two spring tabs on top of filter housing Lift top cover off of the filter housing and set aside b Remove the two filters and dispose of properly Clean internal parts of humidifier per the Cleaning and Maintenance section page 12 of your operator s manual 11 Pivoting Lid Fan Assembly Humidifier Cabinet Spring Tabs Filter Housing l Fixed Tabs Filter Housing Rear of Humidifier Front of Humidifier c Install new filters in the filter housing track with the glue beads of the wicking pad to the inside of the filter housing d Return the top cover of the filter housing by installing cover over the fixed tabs on the rear of the lower filter housing and pivoting the cover down over the top of the filters Snap the cover over the two spring tabs QUARKSP6647 HD14070 SP6647 qxd ragg 3 39 PM Page 12 Replacement and Care of Filters con t e Replace the filter housing in the cabinet NOTE There is a front and back orientation To positi
22. tly The bottles of the whole house humidifier will hold 2 3 8 gallons 9 litres of water each Step 1 To make cleaning easier the humidifier cabinet should be empty and completely dried out To accomplish this use the following method a On the back side of the humidifier cabinet find the float retainer In normal operating mode the retainer will be positioned in the bottom of the slot in the cabinet Push the retainer up to the top slot position in the cabinet until it locks in place See Manual Dryout section on page 9 b Allow the humidifier to run until there is no water left in the cabinet c Unplug humidifier n QUARKSP6647 HD14070 SP6647 qxd agn 3 39 PM Page 13 Cleaning and Maintenance cont d WARNING To reduce the risk of shock always unplug humidifier before cleaning or servicing If humidifier is not unplugged fan could start after housing is removed Step 2 To Remove Parts a Open the pivoting lid and remove water bottles nd set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean flat surface The filter housings are now accessible Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where floor covers are not susceptible to water damage i e kitchen or bath area Lift the filter housing assemblies out of the cabinet and set to the side Remove the water level float from
Download Pdf Manuals
Related Search
Related Contents
Nokia CK-15W - Shanghai Yaohua Weighing System Co, Ltd Tecumseh AE4430U-AA1ACK Drawing Data Fluke Thermometer 80K-40 User's Manual My Document - All Fire International 42WL55A 42WL55E 42WL55R 42WL55T BORKLER GEL IconMaster™ Master Control Switcher Functional Operation and Sony Trinitron KV-BZ213 User's Manual CAB-2 Installation Manual Copyright © All rights reserved.