1. MODELS 2600 2700 5401 62600 62700 72615 72700 and MODEL SERIES T471 MT662C T473 T555 T666 T777 T888 TL470 TL471 TL473 L2600 L2700 _ QJIMOEN INSTALLATION INSTRUCTIONS THESE INSTRUCTIONS MUST BE LEFT WITH HOMEOWNER TUB AND SHOWER VALVES Available with three or four port castings with and without stops Connections are either 1 2 inch I P S pipe or 1 2 inch copper sweat connections If the Moen Slip Fit spout is used a 1 2 inch copper drop and lookout may be used These are shown in the drawings The depth measurement is critical IMPORTANT SEE FLUSHING Use the front face of the plaster ground as a reference point for the fin INSTRUCTIONS PAGE 2 ished wall position including tile 2 1 16 52mm The center line of the supply and discharge piping should be a maximum of 2 3 16 66mm and a minimum of 1 7 16 37mm behind the finished wall surface TUB SHOWER FLANGE lt FINISHED WALL TUB FILLER COMBINATION INE OR SHOWER MN 4 SHOWERHEAD N A NX SHOWER ARM J 2 1 16 l e 2 1 16 HANDLE HANDLE 52mm 52mm A COVER KNOB WasHER PLASTER GROUND e e P 4 1 4 1981mm ooo J 7777775 i l ESCUTCHEON 32mm HANDLE HANDLE Sa SUPPLY SCREW LEVER i SUPPLY i iR i m i i Bo aA a N i m gt 15 16 STOP TUBE 24
2. cartridge turn to the full hot position notched flat pointing to the left and turn on the hot supply for 15 seconds 4 Turn the cartridge to the mixed position notched flat pointing up divert water to the shower and run for an additional 15 seconds 5 Close cartridge 6 Install showerhead MT662C Plaster Ground TO REMOVE STOP TUBE COVER PROTECTIVE CAP Place a flat bladed screwdriver into the slot at the base of the stop tube cover near a support tab as you did when removing protective cap Twist the screwdriver until tab breaks Repeat for remaining tabs a AS TO REMOVE THE PLASTER GROUND aw j HOLE J ACCESS SNAP ON STYLE S Insert a flat bladed screwdriver into the screw hole access Push the retaining arm E towards the outside of the plaster ground until it disengages from the valve body Repeat for other side and remove plaster ground SCREW STYLE Remove screw holding plaster ground in place Discard plaster ground Assembly Use pliers to operate the cartridge Turn on water and check system for leaks If there are no leaks turn OFF water ALWAYS KEEP POINTER UP NOTCHED FLAT 0 For style A amp B Install escutcheon plate and stop tube onstem PUU The notched flat on the cartridge stem must point UP Install t handle parts as shown in the exploded parts view RETAINER CLIP fl STOP HANDLE HANDLE HANDLE C A For style C Attach stop tube to the valve body Ne
3. to the basic shower casting and is actuated SUPPLY by screwdriver The stop is opened by rotating in a counterclockwise direc tion until it stops and closed by rotating in a clockwise direction until it bot toms f SUPPLY SUPPLY F SUPPLY TUB 2 1 8 CC 54MM RUBBER STOP VALVE WITH SCREW DRIVER SLOT 4 1 2 114mm PLASTER GROUND 3 3 4 IPS SIZE AND WALL 95MM OPENING 4 5 8 FOR C C 117mm Rough In 6 FOR P S MAKE SURE ALL WATER SUPPLIES ARE OFF samm 4 port 2700 SERIES Install casting with UP at the top arrow pointing up If the valve is to be used CAUTION for both a shower and a tub connect the top outlet to the shower 36 minimum riser and the bottom out These valves are equipped with let to the tub 6 minimum drop using 1 2 iron pipe size or 1 2 copper water tube 5 8 O D If the valve Moen s long life 1225 cartridge is to be used for a shower only or a tub only plug the outlet not being used designed for smooth trouble free operation When soldering do not 3 port 2600 SERIES These models may be used as either a shower or a tub filler Since they are fac heat valve any higher than neces tory set in the shower position with the outlet up you must reverse the position of the cartridge retainer sary to flow the solder Overheating clip when using the valve as a tub filler Accomplish this change during the assembly process Remove may damage the cartri
4. wall and finish tightening the clamp screw by hand The use of pliers or another wrench on the hex wrench is not necessary Do not overtighten IPS SPOUT CAUTION This spout is A B S plastic and will crack when in contact with some pipe thread compounds C C I P S Please read the pipe compound label to be certain We recommend using thread seal tape thread sealant BO SCREW ON Gs O Screw tub spout onto pipe and tighten by hand If final turn by wrench is needed use small wrench with smooth jaws otherwise pad wrench teeth with rag Pull outward on spout while tightening to avoid scratching the wall DO NOT INSERT TOOL INTO SPOUT END TO TURN SPOUT Flushing IMPORTANT Before closing all wall openings pressure test valve and complete system using flushing instructions IMPORTANT Pipe chips sand stones and other solids found in new or renovated plumbing can damage the sealing surface of the cartridge and cause a leak To avoid dam age DO NOT TURN ON SUPPLY VALVES until instructed below 1 Break off the protective cap on the plaster ground at the top end of the stop tube cover see illustration page 3 Place a flat bladed screwdriver into one of the slots near a support tab and twist to break Repeat at remaining tabs 2 Use pliers to operate cartridge 3 Open the cartridge in the full cold position notched flat pointing to the right and turn on the cold supply for 15 seconds Without closing the
5. dge or rubber the stop tube pull the clip out from the bottom of the casting rotate cartridge stem 180 and replace clip in stop valves Following this direc the top then proceed with assembly using 1 2 iron pipe size or 1 2 copper water tube tion will allow you to solder without g removing the cartridge or rubber WARNING Secure all pipes and the shower and tub drop ells Use thread seal tape on all threads stop valves Use a plain ell on the tub drop A twin ell is not needed CHECK SYSTEM FOR LEAKS BEFORE WARNING The cartridge and rub CLOSING WALL ber stop valves MUST be removed before either brazing or resistance electric soldering For stop valve Install Shower Arm amp Tub Spout removal instructions see last MAKE SURE ALL WATER SUPPLIES ARE OFF SHOWER Install flange on long end of arm Wrap threads on both ends of shower arm with thread seal tape Screw long end of shower arm into wall Do not install showerhead prior to flushing see Flushing C C SPOUT The Moen Slip Fit spout is designed with an O ring seal It is specifically designed for installation with copper water tube Lookout must be free from burrs inside and out The edge must not be rolled inward from a dull tubing cutter The outside surface must be free from nicks and scratches Press and twist the spout onto the lookout upside down Tighten the clamp screw with a 5 32 hex wrench until it just starts to bind Turn spout upright into position against the
6. ientation of stop valve for water flow Stop is in the off position when screwdriver slot is vertical 5 Turn water supply on To Eliminate Cross Piping On Back To Back Installations or To Correct Reversed Rough In Where Hot and Cold Positions Are Reversed Remove handle knob or handle lever and handle parts see Disassembly Turn valve stem around so that the notched flat is turned one half turn or 180 degrees Re install handle parts and handle knob or lever Tighten handle screw securely replace handle parts HELPLINE Call our toll free Helpline number 800 BUY MOEN 289 6636 for answers to any product installation replacement parts or warranty questions Uy MOEN Moen Incorporated 1996 MT662C MARO1 25300 Al Moen Dr North Olmsted OH 44070 8022 U S A Printed in U S A
7. mm 32 HANDLE LEVER 813mm ae HANDLE SCREW HEXAGONAL 1143mm WRENCH 4 48 C dp am ere 1219mm CAUTION WASHER USE 1 2 SET SCREW STOP TUBE RON PIPE HANDLE ADAPTER amp MINIMUM 4 BRAKE ASSEMBLY FLOOR OR1 2 TUBING Always turn water off before installing or disassembling the valve Open CAUTION valve handle to relieve water pressure and to insure that complete water shut off has been accomplished Before turning water on during either rough in or trim out make sure that cartridge retainer clip is in place The cartridge and retainer clip were properly installed and tested before leaving the factory Although it is unlikely it is nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed This should be carefully checked at time of rough in and trim out If the retainer clip is not properly installed water pressure could force the cartridge out of the casting Personal injury or water damage to the premises could result Sto p O pe rat i Oo n WITHOUT STOPS WITH STOPS 7 DIA q 7 DIA 4 4 178mm 178mm CC This type is integral with casting actuated by screwdriver and require a 90 turn to open or close When the screwdriver slot is vertical the rubber stop is closed and when the slot is horizontal the rubber stop is open SHOWER SHOWER IPS This type has been added
8. xt attach the escutcheon using provided hardware Place the washer on the cartridge stem and attach the adapter and brake assembly using the screw Attach handle using set screw i i i i i i i i i TUBE KNOB SCREW COVER i i i i i i i i NS HANDLE LEVER 1 1 1 i 1 1 i 1 1 i HANDLE ADAPTER amp i 1 1 i 1 1 5 1 CARTRIDGE HANDLE BRAKE ASSEMBLY LEVER E STOP TUBE SET screw IMPORTANT FINAL CHECK ALL INSTALLATIONS If above instructions have been followed correctly there will be clearance between the handle and the escutcheon when the handle is pushed into the closed position otherwise the valve will not shut off TO UTILIZE THE MAXIMUM TEMPERATURE LIMIT FEATURE AVAILABLE WITH THE STYLE C LEVER MODELS SEE INSTRUCTIONS ON BACK PAGE To Remove Stop Valve Always turn water supply OFF before disassembly Open faucet to relieve pressure Removal of stop valve 1 Remove handle assembly as shown above and escutcheon 2 Using snap ring pliers remove retaining ring from valve body 3 Grip stop valve stem with pliers and rotate slightly to remove from valve body Re Installation of new stop valve 1 Check to be sure that stop valve stem is fully seated in plug 2 Insert stop valve until fully seated beyond retaining ring groove in valve body 3 Using snap ring pliers place retaining ring in valve body making sure that ring is fully seated 4 Check or

Download Pdf Manuals

image

Related Search

Related Contents

ECOSTEP54 Handbuch_de.indd - Jenaer Antriebstechnik GmbH  es fr de gb it friggitrice gas gas fryer gas  User Manual - J.P. Leisure  HOBART HL200 ERROR CODES AND TROUBLE SHOOTING  Sommario Sony Ericsson W660i  SEPTODONT petite  MANUAL DEL OPERADOR  P.42C-14 - Evo X Service Manuals  4034 630 087 0a MBA TC511 es ME 14.06.10.indd    