Home
MD C300 User's Manual
Contents
1. WARRANTY AirMaster warranties all its power units against electrical component failure for a period of five 5 years Any parts excluding filters required within the first five years will be furnished free of charge by the Authorized Dealer from whom the power unit was originally purchased Additionally all AirMaster units are guaranteed for life against defects in materials and workmanship In the event an Authorized Dealer is not nearby AirMaster will honor and perform warranty services provided the power unit is returned to the factory freight pre paid This warranty is non transferrable and does not apply to commercial applications misuse abuse acts of God operating without the filter or if the unit has been worked on by an unauthorized person Please read this manual before operating Congratulations on the purchase of your new MD Air Master Central Vacuum System This manual covers safety operation and maintenance features built into this system We recommend that you carefully read this instruction book so that you may take best advantage of them BEFORE YOU BEGIN This system has been designed to be fitted by the home user but if in doubt please consult an approved installer This product must be operated in accordance with these instructions and used only for domestic cleaning to remove DRY dirt and dust from household carpets flooring and fabrics This system is intended for domestic household use only and
2. cord If using an extension cord please ensure that it is UL approved and that it is fully extended Failure to do so could cause your central vacuum to overheat and become damaged NOTES CARE AND MAINTENANCE This product once correctly fitted will give you years of trouble free operation Maximum performance will depend on keeping the filters clean or replacing when they have reached their operational life Filters must always be fitted to prevent motor damage The dust container should be emptied when full or when indicated by the light Make sure unit is switched off and power cord removed TO EMPTY DUST CONTAINER There are two clips on either side of the container Place your hand underneath the container to support it and undo the clips Empty container Refit making sure the clips are fully secured TO REPLACE FILTER Your MD Air Master Central Vacuum System has an efficient HEPA filter fitted for maximum cleaning performance and it should be cleaned when the suction level falls or when dirty Follow the same procedures for removing the bottom container You will see that the HEPA filter is held in place by a locking device Turn anti clockwise to remove the HEPA filter Tapping the filter or using a soft bristle brush will dislodge dirt To refit or replace a new HEPA filter replace locking device by turning clockwise Refit bottom section of container making sure clips are fully secured FAULTS Do not conti
3. is not designed for the collection of vitreous building material including particle board construction products and similar products such as wood fibers sand cement fillers fiber glass etc Picking up these materials may be harmful to your system and may void the manufacturers warranty SAFETY REMINDERS AND TAKING CARE OF YOUR MD AIR MASTER CENTRAL VACUUM SYSTEM Please read these instructions thoroughly This will ensure that you obtain full benefit from your system Keep this instruction book in a handy place for future reference IMPORTANT Always switch the system off and remove the plug from the electricity supply before cleaning when not in use or when attempting any maintenance task The system must only be connected to an AC supply at the voltage shown on the rating plate This system should only be used for its intended purpose as described in these instructions Never operate this system without filters DO NOT pick up hard or sharp objects matches hot ashes cigarette ends or similar items DO NOT pick up flammable liquids such as cleaning fluids petroleum products etc or use in the presence of such vapors DO NOT use out of doors or on any wet surface or for WET pick up DO NOT allow children elderly or the ill to operate this system without supervision It must not be used on people or animals Always disconnect the system from the power outlet by pulling out the plug directly NEVER by pulling on the supply
4. iner Retaining Clips Bust Container SERVICE CONTROL PANEL The C300 vacuum system is equipped with a diagnostic control panel that will tell at a glance by the corresponding indicator light if there is a fault It will also tell when the HEPA filter needs cleaning or changing when the dust container is full or when service is needed etc POWER Green Ready for operation AC Switch turns the POWER light on DC Switch turns the vacuum suction on there may be 5 SECOND DELAY SERVICE After 400 hours call for maintenance CLEAN After 60 hours clean HEPA filter FAULT Overload protection triggered Unplug unit and plug in again If it continues to happen the motor is most likely expiring BAG FULL Empty the bottom container CHANGE BRUSHES After 500 hours have a professional change the motor brushes Before making any changes make sure the system is turned off and disconnected from the main power supply REMOVE THE PLUG FROM THE POWER SOURCE TO RESET THE SYSTEM INSERT PLUG BACK INTO THE POWER SOURCE S SOCKET SWITCH ON FLIP THE ON OFF SWITCH LOCATED ON THE UNIT TO THE ON POSITION The system is now reset and ready If a diagnostic light still indicates a fault etc repeat the above procedures Refer to an authorized central vacuum dealer if a fault cannot be corrected or if an indicator light remains on
5. nue to use this system if it appears to be faulty or the supply cord is damaged If a fault cannot be rectified please return to the location of purchase If damaged return the canister for repair to an authorized central vacuum dealer location in order to avoid a safety hazard Consult the trouble shooting guide in this manual if your system fails to operate properly Contact an authorized dealer if your problem persists AFTER USE Switch the system off and remove the plug from the electricity supply Always switch off and remove the plug before attaching any accessories or cleaning the system M D Manufacturing AirMaster Model C300 TROUBLE SHOOTING PROBLEM CAUSE REMEDY Motor does not start or stops No power supply Check cable plug and socket If still inoper ative contact authorized central vacuum dealer Suction force gradually Dust container is full Empty dust container decreases suction hose wand is remove objects from blocked or dirty filters hose wand replace or clean filters Due to our commitment to continuous product improvement and innovation sometimes the product you buy may differ slightly from the one shown on this product carton AE am 1 Motor 2 Exhaust 7A P 3 Air Intake 4 HEPA Filter 5 Filter Latch alle 6 Funnel Sain 7 Debris Container 8 Hook Stand ay Exhaust Diagnostic Control Panel Low Voltage Switch OnOff Swibeh Dust Conta