Maytag MEDX6STBW Dimension Guide

image

Contents

1. PRODUCT MODEL NUMBERS MEDX6STB Electric Dryer Front View 29 737 mm 1 2 13 mm NOTE Leveling legs should be 1 2 13 mm to match height of 3 6 cu ft capacity washer or 12 38 mm to match height of 3 8 cu ft capacity washer The location must be large enough to allow the dryer door to open fully Back View 43 4 141 2 43 4 141 2 121 mm 368 mm 121 mm 368 mm Steam Non Steam Minimum spacing for recessed area or closet installation The dimensions shown following are for the minimum spacing allowed Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing of 1 25 mm on all sides of the dryer is recommended to reduce noise transfer For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered Side View 223 4 273 4 lt 1 33 4 273 4 ae 578 mm 705 mm 349 mm 705 mm A B A Wide opening side swing door B Wide opening hamper door Most installations require a minimum 5 2 140 mm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Minimum Required Spacing 14 max
2. 356 mm lt Le N 51 2 NY Wk 7 va 25 mm A 3 25 mm 76 mm A Recessed area B Side view closet or confined area C Closet door with vents Required spacing W10646601A 12 2014 ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical supply if specified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit VENTING REQUIREMENTS Exhaust venting Exhaust your dryer to the outside 4 102 mm The Vent System charts provides venting requirements that diameter vent is required Rigid or flexible metal exhaust vent will help achieve best drying performance must be used Do not use plastic or metal foil vet Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust Vent System Chart Number of Type Box louvered Angled Exhaust hoods 90 turns of vent hoods hoods Recommended Styles or elbows Rigid metal 64 ft 20 m 58 ft 17 7 m Rigid metal 54 ft 16 5 m 48 ft 14 6 m Rigid metal 44 ft 13 4 m 38 ft 11 6 m Rigid metal 35 ft 10 7 m 29 ft 8 8 m Rigid metal 27 ft 8 2 m 21 ft 6 4 m Louvered Hood Box Hood Acceptable Style Vent System Chart Long Vent Models Only Number of
3. Type Box louvered or 90 turns of vent Angled hoods or elbows Rigid metal 120 ft 36 6 m Angled Hood Rigid metal 110 ft 33 5 m Rigid metal 100 ft 30 5 m Determine vent path Rigid metal 90 ft 27 4 m m Select route that will provide straightest and most direct Rigid metal 80 ft 24 4 m path outdoors Rigid metal 70 ft 21 3 m Plan installation to use fewest number of elbows and turns m When using elbows or making turns allow as much room as possible E Bend vent gradually to avoid kinking m Use as few 90 turns as possible Determine vent length and elbows needed for best drying performance E Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified will m Shorten life of dryer m Reduce performance resulting in longer drying times and increased energy usage Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only For complete details see Installation our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 (施主様向)  MAINTENANCE MANUAL OPERATION AND  Model 775 Operator`s Manual  User Manual I  Philips Classic micro music system DCM186  Voter, mode d`emploi en image - Yverdon-les  工事名 塩浜第1ポンプ場ほか防水改修工事 塩浜第1ポンプ場ほか防水  Manual do Usuário  Alpinisme et environnement - un guide    

Copyright © All rights reserved.
Failed to retrieve file