Maretron TP-AAP-1 User's Manual
Contents
1. Maretron Vessel Monitoring amp Control Systems Installation Instructions Maretron TP AAP 1 TMP100 Ambient Air Temperature Probe NOTE The TP AAP 1 ambient air temperature probe is not intended for measuring the temperatures of liquids Please use the TP IP 1 immersion probe for liquid temperature measurement applications Instructions Please follow these instructions to connect the TP AAP 1 ambient air temperature probe to the NMEA 2000 network via a Maretron TMP100 Temperature Module The wiring diagram appears in Figure 1 below The diagram shows a connection to channel 4 but connections to other channels are similar Please note that the TP AAP 1 may be connected only to channels 2 3 4 and 5 It may not be connected to channels 0 and 1 1 Using a cable clamp or other means secure the TP AAP 1 so that the sensor is in the ambient air whose temperature is being measured 2 The TP AAP 1 cable contains one red and one black wire Connect the black wire to the appropriate Tx terminal on the TMP100 as shown in Figure 1 below 3 Connect the red wire to the appropriate Tx terminal on the TMP100 as shown in Figure 1 below 4 Use a DSM250 firmware 1 3 8 or greater or other Maretron display product capable of configuring the TMP100 to configure the Channel x Source to the type of temperature you are measuring 5 Use a DSM250 firmware 1 3 8 or greater or other Maretron display product capable of configuring t
2. he TMP 100 to configure the Channel x Instance to a number that is unique across the network for the source you have selected In other words if you are measuring Freezer Temperature there may be only one channel on the network that measures Freezer Temperature that has an instance number of 0 Number further Freezer Temperature channels as instance 1 2 and so on 6 If desired use DSM250 firmware 1 3 8 or greater or other Maretron display product capable of configuring the TMP100 to configure the Channel x Label to a text string that allows you to identify the particular temperature that is being measured by this probe For example if you have two freezers you may wish to label one of them Port Freezer and the other Starboard Freezer 7 Using a Maretron DSM250 or Maretron N2KView show the temperature with the source and instance you have selected and verify that you see a valid temperature on the display TP AAP 1 Ambient Air Probe s gdgesQ TMP100 Screw Terminals 123 4 5 6 7 8 9 10 11 12 1 1 Li 1 if Li O N m lt LO Pa R E A E L Figure 1 Wiring Diagram Maretron LLP 9014 N 23 Ave 10 Phoenix AZ 85021 Telephone 1 866 550 9100 E mail support maretron com Web http www maretron com Copyright 2011 Maretron LLP All Rights Reserved P N M002103 Rev 1 1 1 11
Download Pdf Manuals
Related Search
Related Contents
Five Year Limited Product Warranty PowerBay Single User Guide GER.indd Nvidia NFORCE 680I User's Manual installation fiorina 74-90-103 Tiger Jurassic Park III 71-612 User's Manual Chapter 3 - Mangd Switch Software Monitoring Cables Direct KVM-516 KVM switch Descargar Documento - Hospital Universitario San Jose Popayan Untitled - Crosscall "user manual" Copyright © All rights reserved.
Failed to retrieve file