1. Backbone Smart DeskStream Technical Presentation 5 The slide shows part of a typical network with CAUs providing a shared medium interface for the workstations The CAUs are connected to Ringswitches as are the servers Ultimately some users will complain of slow responses especially as both programs and data files get bigger M Easy Integration into existing networks 2 Reduce size of shared ring shared User Ring Greater bandwidth for remaining shared 0 S users 3 Introduce 32Mbps Full Duplex uplink Higher performance access to mi backbone resources Ss 1 Move users to switched DeskStream ports Simple reconnection of ports m Immediate bandwidth upgrade for 23 users Improved manageability and reliability Backbone Smart DeskStream Technical Presentation 6 Switching to the workgroup can help alleviate this problem The DeskStream can be connected between the CAU and the Ringswitch using the single Master or node port 24 on the DeskStream to connect to the CAU and one of the Direct or concentrator ports or an uplink port to connect to the Ringswitch Once the DeskStream is connected and operational the power users can be moved across simply by moving the cable connection no other configuration activity is required These users now get a dedicated connection and will also release bandwidth for the workstations remaining on the shared medium ring
2. Smart DeskStream Technical Presentation 19 Flashing red e g module installed as node but with nothing connected 19 M Connectivity Stacking Module Stacking Module and Cable Installed into stacking slot on rear of each DeskStream in a stack e module has two mini SCSI connectors Supplied with short mini SCSI cable Top port connects to DeskStream above Bottom port connects to DeskStream below Unused ports do not need to be terminated 8 DeskStreams can be stacked Stacking bus has 640Mbps data throughput Smart DeskStream Technical Presentation 20 The stacking bus is not configurable in any way It uses a cell based communications technology similar to ATM The cells are 53 bytes long including an 8 byte header and 45 bytes of payload The bus has 640Mbps of bandwidth available and each DeskStream can access up to 350Mbps 20 M Connectivity Stacking Module 2 Bottom DeskStream Automatically configures itself as Master Assumes responsibility for stack management TrueView sees the stack as a single icon Uses Master mgmt MAC address or LAA e Mgmt MAC is same as base MAC address Single IP address per stack m Single download image e Master takes care of upgrade to all DeskStreams in the stack e Active download e Uses this microcode after reset Smart DeskStream Technical Presentation 21 Trueview displays a single icon for each stack Opening the icon shows the individual units i
3. M High Speed Token Ring HSTR Copper and Fiber Modules 1 Dual Link HSTR Connectivity Each link supports 100Mbps Full Duplex DTR Compatible with IEEE 802 5t Copper module uses RJ45 connectors Fiber module uses SC connectors Links operate independently Offer redundant links load sharing Each link can be set to Master or Slave mode cae ane sis K DP T ifs EN fie ie oe ie e e kh A Ve UPLINK Smart DeskStream Token Ring Switch HSTR Copper ie 2 W B 20 21 22 23 24 Osa u L2 fe ie ke ie ie ke ik AK Ve UPLINK As with the Ringswitch HSTR module this only supports 100Mbps full duplex DTR and is fully compatible with IEEE 802 5t the HSTR specification There are two HSTR modules Copper which uses RJ45 connectors and Fibre which uses SC connectors As we saw with the standard TR module each port is independent and can be used in the same ways with other HSTR components 30 M HSTR Connectivity HSTR Copper and Fiber Modules 2 Allows HSTR connection to HSTR adapters for servers amp power users Backbone HSTR switch ports Other DeskStream HSTR modules e In back to back mode e One DeskStream Link set as master the other set as slave Smart DeskStream Technical Presentation 31 31 M HSTR Connectivity HSTR Fiber Module m HSTR Fiber port Specifications Uses standard IEEE 802 5t specifications Operates at wavelength 1300 nm same as FDDI Supports Multi mode Fiber cabling e 62 5 125
4. 10 Quit Enter selection number 2 3 4 5 6 7 8 9 Smart DeskStream Technical Presentation 37 The CLI is divided into a number of sections each of which is divided further Each will have some Show and Set commands possibly function Enable and Disable 1 General system values system health field values name contact location set passwords 2 Versions version numbers and build time 3 IP IP values set address subnet gateway enable BOOTP DHCP RARP 4 Port Show configure various port parameters on a per port basis 5 Port Group Show configure port group parameters 6 Bridge Show set bridge no hop limit SR or SRT 7 Spanning Tree Show set spanning tree protocol parameters 8 Download Set IP IPX address of binary file host Start IP or IPX download 9 Debug Set address for uploading file dump or configuration data Show last reset last dump last saved data 10 Quit Guess 37 M Smart DeskStream Diagnostic Features Diagnostic Downloads Self tests run on every reboot Output is sent over serial port as it runs m On failing e The test will halt e The Status LEDs will flash to signify an error e The failing test message will be re sent to the serial port every 15 seconds e A terminal can then be connected to see the error Output can be provided to Madge Support for problem diagnosis Allows simple and quick diagnosis of problems Smart DeskStream Technical Presentation 38 38
5. M Spanning Tree IEEE Spanning Tree Support m DeskStream supports IEEE DeskStream participates in negotiation DeskStream CRF and BRF send out and respond to IEEE spanning tree frames CRF to BRF link has a very low path cost to avoid blocking within the DeskStream Blocking will therefore occur at backbone port Ring Number 101 CRF R i ng N u m ber 1 02 Smart DeskStream Technical Presentation 55 In a more complex resilient network the CRF BRF takes part in the bridging conversations since it is a bridge The responses to Spanning Tree management frames is completely normal and so will it will depend on path cost ring number or MAC address as to which ports are designated or standby forwarding or blocking Note on internal blocking This is not a problem if the only BRF port is an uplink but ALL BRF ports will use this interface so if it is blocking this may impact other connections dual attached servers for instance If the BRF or Local interface blocks it may result in the majority of traffic taking a longer less efficient route For that reason it is important that all blocking standby ports are external to the DeskStream i e in a Ringswitch 55 M Spanning Tree IBM Spanning Tree Support DeskStream DOES NOT participate in IBM Spanning Tree negotiation Switch 1 sends IBM Spanning Tree BPDU DeskStream forwards BPDU to all ports including other uplinks
6. Switch 2 receives BPDU and appears as direct link To prevent a loop one backbone port will then block MAAGDEN MARAAAAR BARRERA TS ESTEN Er a pen MAAGRGER KARAARAR ARAB OATS eenst sed veen s on TrItiiieriiiiiie iii n itii Ta Smart DeskStream Technical Presentation 56 A DeskStream stack with only CRF ports doesn t take part in any bridging conversations it acts in the same that a CAU would 56 M Spanning Tree IBM Spanning Tree Support 2 BRF can be configured to participate in IBM Spanning Tree negotiation BRF negotiates with other switches in the network to configure the spanning tree CRF to BRF link has a very low path cost to avoid blocking within the DeskStream Blocking will therefore occur at backbone port Ring Number 101 CRF i tu iojo iojo tatuta s os 3 j iD 7 R i ng N u m ber 1 02 Smart Deskstream Technical Presentation 5 As we saw in an earlier slide 57 58
7. known as the Local Interface and the BRF interface known as the Source Route Bridging SRB Interface is via the virtual port 47 M Source Route Switching Setting up the BRF interfaces m Use the Set icon F EET ing Number Spanning tree 2 Select Advan ed 10 Ren BBA Priority 33024 Specify I Advanced Management address IPX Network 04012002 Hard wired OOOOFEBA1 300 Current ooaoreBA1 300 Reset Cancel Apply Help i DeskStream Barbara aC Ol lll Ale 2 M Madge Networks Smart DeskStream Token Ring Switch ieee Beer ar BN ROW MTR Ae ee Oe ae ae PTT TTT TT E Hi Wie Ta Mie Me ee Ue Smart DeskStream Technical Presentation 48 Setting up the BRF is a global function using the indicated icon The port grouping dialogue box specifies the CRF parameters but the Advanced button takes us to the internal interfaces local and SRB 48 Local IF parameters SRB IF Advanced Spannmg Tree Options Source Route Switching Setting up the BRF interfaces DeskStream Thais we Zinema interfaces to ellect a SR bridge between the croup ol al baio ron SA bridge porte and the other SR This cov then d rebed pats The fits interface is a LOCAL intestace to fre group of al basc pits rietacss lo Ihe And rretace schie ha SA Bidongrteilacs Accodteph thors aie ino sets of Sparring Tres paremelers ono set for each of these interlaces Lo
8. Presentation 9 If bandwidth still needs to be extended the DeskStream supports HSTR uplink modules both copper and fibre These only work as a point to point full duplex link and so potentially will allow a 200Mbps connection M Smart DeskStream Family Summary Smart DeskStream Token Ring Switch 24 workstation ports with two module slots Smart DeskStream Stacking Module One required for each DeskStream to be stacked Smart DeskStream TR Fibre Module Dual ports 4 16Mbps and DTR load sharing and redundancy Smart DeskStream HSTR Copper Module amp Smart DeskStream HSTR Fiber Module Dual ports 100Mbps load sharing and redundancy Smart DeskStream Technical Presentation 10 10 M Smart DeskStream Background Positioning Smart DeskStream behaves like a hub When integrating DeskStream into an existing network use it as if it was a CAU LAM Smart DeskStream is designed for simplicity DeskStream offers full auto configuration for simple installation Smart DeskStream Technical Presentation 11 11 M Smart DeskStream Background Positioning Smart DeskStream is NOT designed as a backbone applications switch You can only support a shared device on one port a It does NOT offer Active Broadcast Control full RMON or protocol filtering e These are backbone features not required at the workgroup level m Smart Ringswitch Family is for backbone solutions DeskStreams
9. Smart DeskStream Token Ring Switch Source Route Switching M Smart DeskStream Objectives At the end of this session you will be able to Explain Source Route Switching including Concentrator Relay Function Bridge Relay Function Demonstrate IBM amp IEEE Spanning Tree support m Use the built in Diagnostics Smart DeskStream Technical Presentation 40 40 Source Route Switching What is Source Route Switching Industry term for using switching in the workgroup Refers to IEEE 802 5 Annex K specification Supports Transparent and Source Route traffic How does it work Switch behaves like a transparent switch e Matches the MAC address and route descriptors to ports Source Route information is preserved Smart DeskStream Technical Presentation 41 41 M Source Route Switching Annex K Components of Annex K Concentrator Relay Function CRF e Handles switching process e All ports access the network using the same ring number source routing e Includes all ports by default within a stack of DeskStreams Bridge Relay Function BRF e Allows bridging between CRF and ports on different ring numbers e Equivalent to an IEEE SRT switch Smart DeskStream Technical Presentation 42 The CRF manages all the basic ports including a virtual port which gives a link to the BRF interface and any ports which have been transferred to that inter
10. can also set an LAA if we want to 51 M Source Route Switching Combining CRF and BRF functions CRF is operational on all ports in stack by default CRF will attempt to learn ring number a the CRF ring number can be manually configured BRF will only function on master DeskStream only ports on master DeskStream are supported on BRF a Each port can be designated as a BRF port including option module ports Each BRF port has its own ring number BRF ports can auto detect ring number Internal virtual port links between the CRF and BRF Smart DeskStream Technical Presentation 52 Summary CRF will attempt to learn the ring number from the RIF in passing frames as will the BRF 52 M Source Route Switching Introducing multiple uplinks 3 Load sharing resilient connectivity Dual uplinks to the same backbone switch This is an illegal configuration two ports on the same switch cannot connect to the same ring Use BRF to set one of the ports to a different ring number This is a legal configuration both uplinks will be active If middle DeskStream fails both DeskStrea retain backbone connectivity 101 pa aap Saran kamen Teho MAAGDEN MARAGRAR AAAARARG ES gn Saranan MAAGR GER MARAAAAR AA R i ng N u m ber 1 02 Smart DeskStream Technical Presentation 53 What do we need the BRF for One use is in resilient networks The DeskStream replaces the shared medium hubs which are oft
11. CAUs and RAMs can t use full duplex DTR but the DeskStream can So the uplink to the Ringswitch is a more efficient link than the original CAU link M Easy Integration Hub Replacement Switched User Ring mi fo AL 1 Add DeskStreams as needed bassas wikken a Easily scalable solution High port density releases rack 2 Move all users to switched ports Performance security and manageability for each user connection i i Network Backbone Smart DeskStream Technical Presentation 7 As time and money permits the remaining workstations can be phased over to a switched environment as more DeskStreams are installed and stacked M Powerful Flexible Connectivity Resilience Switched User Ring 1 Add additional links to GB backbone E Resilience load sharing and higher access speeds Network Backbone Smart DeskStream Technical Presentation 8 CAUs can be connected to two Ringswitches to give a resilient link so can the DeskStream either as a standalone device or as shown in the slide as part of a stack M Powerful Flexible Connectivity Resilience and Performance Switched User Ring 1 Use HSTR uplinks to increase backbone access Resilience load sharing and higher access speeds E E D 10 1 si JAD A ina o oN 2 x 100Mbps l i 0 B i i Backbone Smart DeskStream Technical
12. Smart DeskStream Token Ring Switch M Smart DeskStream Objectives At the end of this session you will be able to a Describe the Smart DeskStream features a Demonstrate its connectivity options including e Ports and LEDs e Stacking module e TR fiber module e HSTR modules a Explain the DeskStream s management options using e TrueView 32 amp DeskStream Manager e Command Line Interface e Power on self test diagnostics Smart DeskStream Technical Presentation 2 What is Desktop Switching Conventional Shared Token Ring Shared User Ring Users share the Token Ring os network T Gea R s O O Often up to 80 users share 16Mbps sos CAU LAM or Chassis Switched ring Fully Switched Token Ring Each user has their own dedicated Token Ring No need to share 16Mbps with other Desktop users Switch Connections can be Full Duplex 32Mbps Smart DeskStream Technical Presentation 3 The CAU LAM is the ring Users share the bandwidth available on that ring typically 16Mbps these days A ring can support over 250 users in theory but in practice this number is better limited to around 80 Even at this reduced number power users may suffer from bandwidth starvation The DeskStream allows them to each have a full 16Mbps since each port is its own ring If the adapter driver will support it the connection can be full duplex DTR which allows a maximum through
13. Transparently bridged network one port will be forwarding the other blocking Blocking ports allow no frames to pass 45 M Source Route Switching Bridging using BRF What is the Bridge Relay Function Provides SRT bridging between SR ring numbers on different ports Allows a different ring number to be set on each port a Ports cannot share a ring number Smart DeskStream Token Ring Switch 18 19 en et EI 24 s 5 5 a fart DeskStream Technical Presentation 46 The BRF allows us to set up ports outside the CRF These have individual ring numbers which cannot be shared The BRF allows these ports to communicate with each other and through the CRF with the ports using the shared ring number 46 M Source Route Switching Bridging using BRF m What is the Bridge Relay Function i i i DeskSiream ports j CRF Port Interface Local Virtual port BRF Port Interface SRB bzi 17 20 Fa 23 ils 107 jn 108 re 109 Smart DeskStream Technical Presentation 47 The CRF manages switched communication between its ports The BRF is only available on the Master DeskStream the bottom one in a stack and manages switched communications for the BRF ports By default all ports in a DeskStream stack are in the CRF but we can enable the BRF interface on any or all of the Master DeskStream ports including the uplink modules Communication between the CRF interface
14. and Ringswitches can be integrated to provide a TR switching solution Smart DeskStream Technical Presentation 12 As we Saw in the slides on integrating into an existing network the DeskStream has only one workstation port which is capable of being connected to a shared medium hub Uplink ports can be connected to CAUs either as nodes or if using fibre as RI RO ports This connectivity option is not recommended 12 Smart DeskStream Token Ring Switch Connectivity Connectivity Ports m 24 RJ45 ports Each behaves EXACTLY like a shared hub port Each port has its own MAC address Ports 1 23 are direct each can be connected to e Adapters e Bridges Routers e Backbone TR switches Direct ports are also known as slave or concentrator on Ringswitches ports Smart DeskStream Token Eine Switch ir ie ie ie ee Me gn Ze Smart DeskStream Technical Presentation 14 The DeskStream workstation ports are RJ45 connectors and are ports which work like a shared medium hub port i e in classic mode they will require the phantom drive to be present Each port has its own MAC address so whether working in classic mode or full duplex DTR the connection there will be only two addresses on the link Ports 1 23 are called direct ports and are similar to concentrator ports on a Ringswitch They are also sometimes known as slave ports They will accept a connection to a TR adapter a bridge o
15. bled or disabled No other port parameters except port mode on port 24 can be configured 16 Connectivity Ports LEDs Left Port LED Green Port open Flashing green Disabled m Right Port LED Red Port closed Flashing red Error Port 24 will flash red by default because it is master as default Smart DeskStream Token Fi rT 20 es ze TTT Smart DeskStream Technical Presentation 17 Left LED flashing green disabled by management software Right LED red This happens when a connection is made against the configured set up e g workstation connects with a non DTR driver into a manually configured DTR port 17 Connectivity Status LEDs m First LED on right of unit Status Green Normal operation Flashing green Diagnostic self test Red Error e System Failure Flashing Red Warning e E g Fan Failure Smart Deskitream Token Fing Switch ihe ie ie i ie Toa Se Smart DeskStream Technical Presentation 18 System failure e g CPU crash i e will require a replacement DeskStream Warning failure which allows the DeskStream to continue working at least temporarily 18 Connectivity Status LEDs 2 Second LED Module Link 1 Green Port open Red Port closed Flashing green Disabled Flashing red Error Third LED Module Link 2 As for Link 1 Smart Deskitream Token Fing Switch ihe ee i ire Toa Se
16. ca intetface Spanreng Troe Paranators Pel pronty he 02 Pai pah Clot Hems G Auromaticaly select cost Lona interface Spanreng Tree Status State Blocking SA Endor tofas Spwreg Tree Paraman Port priy h 0 25 Pat path Teat 1 535 Sutonaiosdy select cost iian plefnce Sparing Tree Stann BU OEF TAC ES parameters DeskStream Barbara Eal M Madse Network A oh ohe h Designated port 8000 MOOEFZACAIS Osagisted bike Han dele alii l Decodeddas 33024 OONIFERBF4EO 8107 DONSFOD FN Desyaed ot 100 8039 hed 32768 4 O000FREE 1340 Designed bridge Raw dete Decoded data NT BDD 3304 ODOFEARFAAD Des greed coat 100 Desgrtedpat DI heul be Smart DeskStream Technical Presentation 49 The main use of the two parts of this dialogue box is to vary the path cost These two interfaces are within the DeskStream and for optimal network management we don t want these to be standby or blocking bridges The local interface by default will have a very low path cost 2 and so should always be designated or forwarding The SRB interface is currently defaulted to auto path cost and so will get a value based on the ring speed divided into 1000 62 for 16Mbps 10 for 100Mbps It might be sensible to lower this manually 49 M Source Route Switching Setting up BRF on a port Select a port dge Hed ozel DexkS te aba Cy T J I Madge Naima Sria
17. e uplink ports on all the Deskstreams in the stack Smart DeskStream Technical Presentation 25 Managing the Uplink Module The uplink is a function of the stack so selecting the uplink icon will display all the uplinks in the stack 25 Uplink Connectivity Ing Madge Networks Smart DeskStream Token Ring Switch sa 18 20 21 22 23 2 PTT Tt ii ii ie ie ie ie ie ie ie SS 84 Madge Networks Smart DeskStream Token Ring Switch HSTR Copper st 1 8 19 20 21 2 2 24 oe u L KAAN Ze EUN The icon will display all the uplink ports which exist on the stack Select individual ports for management Link 1 is port 25 and Link 2 is port 26 Smart DeskStream Technical Presentation 26 Managing the Uplink Module The uplinks are to a large extent just two more ports similar to port 24 in that the port type can be configured They are numbered 25 and 26 In a stack each port is known by the DeskStream number in the stack followed by the port number e g 2 21 this is the second Deskstream counting up from the master 1 and port 21 26 M Fiber Connectivity TR Fiber Module 1 Dual Link Fiber Connectivity Each link supports 4Mbps 16Mbps and Full Duplex DTR Links operate independently Allows redundant links load sharing in Fiber environments Each link can be set to Master or Direct mode Node or Concentrator mode Smart DeskStream Token Ring Switch KEIN ta 48 20 Mt zz En Ba RE Er BE Br fee
18. ee ee ee AK La ve UPLINK The two uplink ports although physically mounted on the same module are in fact separate entities which will operate independently This means that they can each be used for different functions if necessary one could be an uplink to a Ringswitch the other could have a server attached for example they could each be connected to different Ringswitches to allow a dual path not very resilient if the DS fails or one could be used to connect to another remote DeskStream while the other had a server attached and so on More examples on the next slide This is possible because the port type can be configured 27 M Fiber Connectivity TR Fiber Module 2 Allows Fiber connection to TR Fiber adapters Backbone TR switch fiber ports Third party Fiber TR shared hub ports TR CAU Fiber Trunk Link e configure for Ring In Ring Out mode Other DeskStream Fiber modules e In back to back mode One DeskStream Link set as master the other set as direct Kk Fiber R foe fat ie Er ES ee UPLIME Can be configured in the same way as a Ringswitch fibre port for attachment to a CAU fibre RI RO port 28 M Fiber Connectivity TR Fiber Module 3 m Fiber port Specifications Uses standard IEEE 802 5j specifications Operates at wavelength 850 nm Supports Multi mode Fiber cabling e 62 5 125um or 50 125um acceptable Distances of 2Km ST connectors Kk Fiber R foe fat ie Er ES Er UPLIME 29
19. en connected to two backbone switches to ensure a connection As we have seen connecting two CRF ports to one Ringswitch is an illegal configuration and will fail If we need to connect this way perhaps to ensure maximum connectivity for a DeskStream stack if one fails catastrophically then the BRF with a different ring number makes this an allowable configuration We will need to manage the path costs to ensure that standby SR or blocking Transparent ports are in the Ringswitch 53 M Source Route Switching Introducing multiple uplinks 3 m Setting Spanning Tree mode Bet copy tt on al varierend treme Select icon ELLES Blobalopland 11 14 IEEE or IBM m Farma ding node RT or SR only Ce coc we DeskStream Barbara AI eh saae Balls 2 ws Manan iy hia Smart Dr oe REN Switch ze 6 6 1 8 15 i fe ie eT ie ee et Ze Smart DeskStream Technical Presentation 54 Selecting the bridge icon brings up the Bridging Information dialogue box In this we can set the Bridge Number in a resilient network and the global hop count limit this has a maximum of 7 for the IBM spanning tree option and 13 for IEEE 802 1d We can choose the spanning tree option we want to use Don t forget that this must be consistent over all relevant devices on the network We can also choose whether the switch will support SRT or SR only Selecting SR only will change the spanning tree mode to IBM SR 54
20. face Ports within the CRF all use the same ring number although they are not in a ring this is a switched environment This allows an SR frame in an SR network to find the correct DeskStream stack the CRF will sort out from its Address Descriptor table which port to pass the frame to The BRF allows us to take some ports out of the CRF and assign a different ring number to each The BRF manages the switching between these ports and via the CRF to the basic ports 42 M Source Route Switching Frame Forwarding using CRF DeskStream behaves as a transparent bridge It learns the MAC and RIF information in passing frames and builds up an address table e Also known as Active Learning As frames arrive the next hop or destination MAC address is looked up in the table to determine which port to forward the frame e If the destination MAC address or route descriptor is not listed against a port the DeskStream forwards the frame to all ports Up to 2048 entries of MAC or route descriptor in each DeskStream Smart DeskStream Technical Presentation 43 43 Source Route Switching Introducing multiple uplinks 1 Resilient links Dual uplinks to the same backbone switch A Smart Ringswitch Plus This is an illegal configuration two ports on the same switch cannot connect to the same ring Note SRT will not overcome this SRT learns configuration from ring poll process which DeskStream only perform
21. ll divide around the failing DeskStream resulting in two stacks each of which will be detected by Trueview if both stacks have an uplink The Master will detect this failure and reboot the remains of its stack stack 2 in the slide A new master will take control of the new stack and start with a reboot If the network is using IP and a secondary uplink exists it will be necessary to give the upper part of the defective stack an IP address if both parts are to continue working A DHCP server will be helpful here 23 M Connectivity Stacking Module 5 DeskStream Resilience If stacking module remains operative Stack will reboot If failing unit is in the stack center stack continues to operate DeskStream will be shown as failed under TrueView 32 MAAGDEN iii ti aii ire MAAGDEN MARAKEAR BARRERA ES Raabe Dae h kaddkdakiakangts MORGAN MARARKAR AAAARANGT Smart DeskStream Technical Presentation 24 In the second case the Master will detect the failure and attempt to recover the failing unit by rebooting the stack Assuming this doesn t solve the problem Trueview will show the stack with a failed module but the stack will continue to operate Of course users on the failed module will be off the network 24 Uplink Connectivity ma Tolis Switek ae TL rn en KREEK KAKKEN ERAAN Ee its dee Networks Smart Dakota To amp ite se he ie te ee ie ie ee fe i re te ee i ie ie i The icon will display th
22. n the stack 21 M Connectivity Stacking Module 3 m Stacking Module cannot be hot swapped DeskStream unit must be powered off before installing stacking module Cable may be connected to another DeskStream while it is powered on Stacking becomes active on reboot of all DeskStream units in stack Smart DeskStream Technical Presentation 22 It is important to remember that any installation or removal of modules must be done with power off this device has no hot swappable units Cabling is of course movable at any time and this includes the stacking bus cables Removing a stacking bus cable will be detected by the Master unit and this will cause a reboot adding a cable is not detected by the Master so a manual stack reboot will be required 22 M Connectivity Stacking Module 4 DeskStream Resilience Lost power or stacking module failure Stack will reboot a If failing unit is in the stack center two separate stacks will form New stack appears under TrueView 32 If secondary uplink exists Fn men Tek LLL Lait tier its peony Sao an PLUILIL EAP tii ti iin VTE ren They PTritetiietitiitiatiiiiy wg ara a aaran AAAA AARAA AAA RARA RAAG A DeskStream may fail in two ways one in which the stacking bus is taken down usually a total power failure and another where the DeskStream fails but keeps the stack active Smart DeskStream Technical Presentation 23 In the first case the stack wi
23. nt frame option Simplified support Menu icon to view all microcode versions Configuration downloads and uploads Switch status report Smart DeskStream Technical Presentation 36 We can set up to five write and read passwords to give several people different levels of management access to the DeskStream The Dynamic table or port configurations allows us to change any one of the configurable port parameters on one or more ports at one time The contents of this table can also be saved to file clipboard or to a printer for archiving When saving this table wait until it has finished its dynamic restore Bridges and switches sometimes have a problem with the setting of the Address Recognised Frame Copied bits when using transparent bridging This can be manually configured on the DeskStream A Trueview icon will display the hard and software versions this information can be saved to a file clipboard or to a printer Dump and Configuration data is also noted in this table which can be uploaded and subsequently if necessary downloaded back to the DeskStream Opening the I field icon will show a status report for the DeskStream if there is a problem a Details button will give more information 36 Smart DeskStream Manager Command Line Interface Telnet and serial interface menu is easy DeskStream Terminal Configuration 1 General Versions IP Port Port Group Spanning Tree Bridge Download Debug
24. put of 32Mbps M Smart DeskStream Product Overview Designed as a shared hub replacement m 1 U high m 24 ports with auto ring speed and protocol detect Plug n Play installation Easily stacked to offer up to 192 ports High performance switching Simple graphical management Smart DeskStream Technical Presentation 4 The DeskStream is a workgroup switch i e There is no internal ring data is switched between ports It is designed to replace the shared medium hubs e g CAUs and RAMs It is 1U high which saves space in the rack The racking lugs are user installable since it can be a free standing unit as well By default all ports are speed detecting and can also negotiate full duplex or classic mode token ring Both of these parameters can be manually configured if necessary In general the default setting allows us to connect it up and it just works Up to eight DeskStreams can be stacked using the stacking bus this means that a single stack can support up to 192 workstations in a completely switched environment The stack can also support up to 16 uplink ports All ports can providing that the drivers support it run in full duplex DTR mode Managing via the Trueview GUI is straightforward Each stack shows as a single icon opening the icon reveals each DeskStream and allows them to be managed individually M Easy Integration into existing networks Shared User Ring T ypical Network O Layout
25. r router port or a Ringswitch port set up as a node 14 Connectivity Ports 2 m 24th RJ45 port a 24th port is a master and can be e connected to a shared Hub port any type vendor e re configured as a direct port Master port is also known as node on Ringswitches Master port can therefore be configured as node or concentrator similar to a Ringswitch port Smart Deskitream Token Fing Switch ie ie ie A ej 0 Smart DeskStream Technical Presentation 15 Port 24 is configurable but by default it is a master or node port This can be connected to a CAU or RAM port or to a Ringswitch port that is in concentrator mode 15 M Connectivity Ports 3 m Ring Speed Protocol Detect a Each port supports 4Mbps 16Mbps and Full Duplex Dedicated TR e Default is auto speed sensing e Ring speed may be manually configured on a per port basis Impedance is matched to support UTP STP cabling e No requirement for a separate media filter Balun a Negotiates Classic TR or full duplex DTR on insertion Pot ran Pot 6 Dreri Firg Speed 1E M bas Rosini FingSpesd Sto Pot mode Smart Deskitream Token Fing roin Certan Ato xj 17 18 19 eo z1 te ed out Aing stu Nowesi ht dupi ll ll lal all ll ee o Smart DeskStream Technical Presentation 16 The port can be given a name and the ring speed and protocol can be left as Auto or can be configured manually The port can also be ena
26. rt Disk tmaz Tokan Ring Seriele Ni ed bie Ge nd Ge Nagios ak le ia is di men i Ee a ARR aAe LLET IT A os PES Spare Ts Kaleici Select SR bridging DeskStream Barbara M Madge Networks Smart DeskStream Token Ring Switch eek ENE eee ee 1 48 198 z0 21 22 23 Hie ie ie ie the Toa Wie te ie ie tga So Smart DeskStream Technical Presentation 50 Once the interfaces are set up enabling SRB on individual ports on the Master DeskStream is simple The SR Bridging entry in the menu will only appear on ports on the Master DeskStream Select this entry 50 M Source Route Switching Setting up BRF on a port 2 a Enable SRB Se V Fling Murter Bridge Liras m Auto learn or n A a i I C Speci po Specify ring number Haired ODOFA M n Furcsa fo Bridge toat Sise Diobisd Carcel Apoi Help DeskStream Barbara Sal Ol 8 3 zadel 3 2 M Madge Networks Smart DeskStream Token Ring Switch eek ENE eee ee mo on 2 139 14 1 16 1 18 19 20 21 22 21 24 PTT TTT TT E tie Wie Ta Mie Mie ee Ue Smart DeskStream Technical Presentation 51 The resulting dialogue box is similar to that for the CRF except that we can enable Source Route Bridging and there is no Advanced button We can choose to enter a ring number or let the device find it for itself we can set the maximum hop count this will vary depending on whether we are using the IBM spanning tree specification 7 or the IEEE 13 We
27. s on each port Spanning tree will close one of the ports Ring Number 101 MAAGDEN AERARRAE CARRERA TS ma wee GEESA en Backbone MAAGDEN MARAGRAR AARARANG ES Smart DeskStream Technical Presentation 44 Duplicate links to the same Ringswitch will usually result in a bridging error bridging a ring to itself makes no sense and spanning tree will close one of the ports 44 M Source Route Switching Introducing multiple uplinks 2 Load sharing connectivity Dual uplinks to different backbone switches Both uplinks will be active allowing load sharing of source route traffic AREs and specifically routed frames will pass through Transparent traffic will still be blocked on one pow Activ Ring Number 101 MAAGDEN MARA ARAA BARRERA ES MAAGDEN MARA ARAA CARRERA ES g PEE Pp en Backbone Smart DeskStream Technical Presentation 45 Dual connection to two Ringswitches each with its own bridge number and both ports having the same ring number assigned is a valid and normal resilient operation On a Source Routed network one of the Ringswitch ports will be designated the other standby Standby ports will not pass Spanning Tree Explorer frames sometimes called Single Route Explorers but will pass All Routes Explorers and Specifically Routed frames In a
28. t DeskStream Management Features Software Downloads Download in active mode e Download becomes active on reboot Single download file for all flash and microcode files e TFTP over IPX or IP e SNMP over IPX or IP e Flash memory to run diagnostics MAC and boot sequence Smart DeskStream Technical Presentation 35 All downloads are performed via a normal network connection when the DeskStream is active The new microcode is stored in flash memory until the next stack reset when it is stored permanently There is a single binary file for all required software for the DeskStream The process can be managed from within Trueview when we specify TFTP over IP or IPX or the serial port or Telnet which uses raw SNMP commands IP only of course over Telnet Using the serial port or Telnet to manage the process is simple over IP we just need to specify the IP address of the machine hosting the binary file and the path to the file It is a little more complex over IPX since we will need to specify the Network id 8 hex digits the node id MAC address 12 hex digits and the socket id 4 hex digits E g 00000002 Network id 0000F63D1836 Node id 5400 Socket id Use the Trueview Tools Services Configuration to discover these values 35 M Smart DeskStream Manager Advanced Functionality Easy to configure options Up to 5 write and read passwords Dynamic table of port configurations Copy bit on transpare
29. um or 50 125um acceptable Distances of 2Km SC connectors Smart DeskStream Technical Presentation 32 32 Smart DeskStream Token Ring Switch Management Network Management Smart DeskStream Manager Graphical Windows based management Uses Madge s TrueView 32 platform e 16 bit TrueView does not support DeskStream Easy to use Will integrate with other platforms e DeskStream Mgr for HP OpenView for HP UX and NT e DeskStream Mgr for Tivoli NetView for IBM AIX Command Line Interface CLI Text based via Telnet session or Direct serial connection Allows access to more complex operations Smart DeskStream Technical Presentation 34 There are two major ways of managing the DeskStream 1 Using Trueview 32 2 Using the command line interface There is no 16 bit Trueview device manager for DeskStream and so it can only be managed with Trueview 32 the 32 bit version This is just another device manager and is used in the same way that other device managers are used in Trueview Trueview itself can be integrated into higher level network management software e g HP OpenView and Tivoli NetView Using one of these to access a Madge device will bring up the Trueview device manager The command line interface can be used via a null modem connection to the 9 pin serial interface on the back of the DeskStream or using IP and Telnet through the normal network ports The content is the same 34 M Smar