1. RETAINER BATTERY PACK 1000 300 007 VO 1 Remove screw securing the battery retainer 2 Remove the battery retainer 3 Insert battery pack into back plate 4 Install battery retainer 5 Install screw to secure the battery retainer 6 Connect battery connector to receptacle on PC board 7 After all wiring connections have been made snap the front assembly to the back plate so it is held by the locking tabs 8 Plug the transformer into a 24 hour 110VAC unswitched outlet Note Rechargeable batteries may take up to 48 hours to fully charge LOW BAT message should clear within four hours or by entering Test Mode WARRANTY INFORMATION For the latest warranty information please go to www honeywell com security hsc resources wa 4 Program the Control Change the Installer Code The factory default Installer Code for the Lynx Plus Series Control is set to 4 1 1 2 To change this code you must enter Expert Programming mode 1 After Power up enter Installer Code 8 0 0 or press both the and simultaneously within 50 seconds after power is applied to the control The system will enter the Expert Programming Mode and 20 INSTALLER CODE will be displayed Note Upon power up or after exiting program mode the system takes up to a minute to reset To bypass the reset delay enter 0 2 Enter 20 3 Enter a new four digit Install
2. Lynx Plus Series Control Quick Installation Guide This Quick Installation Guide can help you install the rechargeable Lynx Plus Series Control quickly and easily by providing the basic steps for installation using the built in defaults and the Voice Prompt Programming mode The Voice Prompt Programming mode allows you to quickly program the system by responding to a series of voice prompts FOR DOCUMENTATION AND ONLINE SUPPORT http www security honeywell com hsc resources MyWebTech see Lynx Plus Series Installation and Setup Guide P N 800 03857 or higher 1 Install the Control MOUNTING TELEPHONE CONNECTION ROTATE FRONT CASE UPWARD TO RELEASE PLCD CONNECTOR in BATTERY CONNECTIONS ca eR ILH 2 te 4 pa ON yA esmuesmve a Li COMMUNICATIONS 7 IH PORT A S J GSMVL AUDIO CABLE CONNECTOR FRONT CASE LOCKING TABS 1000 300 011 VO Separate the front case from the rear case by rotating the front case and releasing the hooks from the rear case Feed the wiring through the openings provided in the rear case Mount the rear case to a sturdy wall and secure with the provided screws Reconnect the front case and rear case 800 03860 9 09 Rev A 2 Make Wiring Connections WARNING l UL NOTE I I Rik PREJENT 1 1 THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE 26 GAGE 1 DISCONNECT TELEPHONE LINE A
3. T TELECOM l JACK BEFORE 1 SERVICING THIS UNIT INCOMING TELEPHONE 2k EARTH HNE PREMISES OHMS C Z GROUND 4 TELEPHONE EOLR pL TIP RING TIP RING ALL OUTPUT CIRCUITS ARE POWER LIMITED HARD WIRED ZONE USE ONLY THE K10145WH K10145X10 OR K10145CN TRANSFORMER PROVIDED 6 14VDC 6 14VDC 30mA max 120mA max PIEZO K10145WH K10145X10 H WWZ OR K10145CN F T ZONE L SQ a ae T T SOUNDERS AC TRANSFORMER 9VAC 25VA 1000 100 004 VO Note For the complete Summary of Connections refer to the Lynx Plus Series Installation and Setup Guide P N 800 03857 or higher Make earth ground connections to terminal 1 Connect the incoming phone line to either the 8 position jack or terminals 2 TIP and 3 RING Connect the handset phone lines to terminals 4 TIP and 5 RING Note For full line seize operation refer to the Lynx Plus Series Installation and Setup Guide 4 If used connect a piezo sounder or bell to terminals 8 and 9 5 Connect the sensors contacts to the hardwired zone terminals 6 and 7 6 If used connect the GSML or GSMVL communications device to the GSML GSMVL communications port 7 Connect wires from the K10145WH K10145 OR K10145CN Transformer to terminals 10 and 11 Note If using Powerline Carrier Devices refer to the Lynx Plus Series Installation Guide P N 800 03857 or higher 3 Make Battery Connections SCREW NOTE WALYNXRCHKIT SHA BATTERY PACK SHOWN
4. al Station Account Number Select Enter second Second Central central station Station Account account number Number up to 4 or 10 digits Press Press SELECT ADD Select First Central Station Account Number Press ADD Press SELECT Bedroom Basement Bathroom Master Bedroom Utility Room Nursery Den Garage 8 Program Additional Options Enter Expert Programming Mode 4 The Lynx Plus Series is configured with Factory Default Settings You can revise these settings using the Expert Programming Mode Refer to the Installation and Setup Guide to view these defaults and to continue programming the individual fields using this mode Fire Detection Once you have entered the Expert Programming Mode the ESCAPE key can be used to return to the Voice Prompt Programming mode If you are in any of the Interactive Menu Modes 56 x80 x81 x83 x84 or x85 you must return to the main menu in that field before pressing the ESCAPE key Select Expert programming mode Press SELECT Exit Expert Programming Mode When programming is complete enter x99 9 Perform Go No Go Test Temporarily mount wireless devices in the preferred mounting location and perform a Go No Go test to ensure adequate signal strength is available 1 Enter Installer Code 8 and run Go No Go Test 2 Fault each transmitter to ensure all programmed zones are received 3 Mount the transmitter in its permanent lo
5. cation System switches to Expert Programming Mode Refer to the L3000 Series Installation and Setup Guide for additional programming instructions Laundry Room Upstairs First Second Third Rear Side 10 Program User Functions Set the Real Time Clock 1 Enter the Installer Code FUNCTION 63 2 Follow the Voice Prompts to program the Clock Calendar Change the Master User Code 1 Enter the Installer Code CODE _8 02 desired 4 digit Master Code Add User Codes 1 By following the procedures in the Lynx Plus Series User Guide show the User how to add additional User Codes 11 Test the system 1 Enter the User Code TEST key The external sounder will sound for two seconds and all the LCD segments on the keypad display light for 3 seconds Open each protected door and listen for three beeps from the keypad followed by the zone s Voice Descriptor Identification of each faulted protection point should appear on the display and clear when the door is closed Walk in front of the motion sensor and listen for three beeps and the zone s voice descriptor 4 When testing is complete enter User Code key Press each key on the key fob to confirm it performs its assigned function Note Refer to the Lynx Plus Series User Guide for additional information
6. ce System announces descriptors for the programmed pendant Select Emergency Press Press Press SELECT SELECT ADD 5 Pendant Type Medical Fire Silent Police Police Add a Wireless Key When adding wireless keys wait 5 seconds between transmissions A Select Keys Press Press SELECT ADD 6b Delete Sensors Delete Sensors Activate transmitter twice System announces the key number Select Sensor to be Deleted Press Press SELECT DELETE Select Delete Sensors 7 Add Central Station Accounts Add First Central Station Phone Number Select Enter first First Central central station Station Phone phone number Number up to 20 digits Press Press Press SELECT ADD ADD Add First Central Station Account Number j All four digits of the Central Station Account numbers must be Enter first central station account number up to 4 digits entered For ten digit format all ten digits must be entered Refer to the Lynx Plus Series Installation and Setup Guide for additional information regarding these programming options Enter first central station account number up to 4 or 10 digits Press Press SELECT ADD Add Second Central Station Phone Number Select Enter second Enter second Second Central central station central station Station Phone phone number account number Number up to 24 digits up to 4 digits Press ADD Add Second Centr
7. er Code Program variable data fields If required enter 24 to program the desired 2 digit RF House ID for wireless keypads If required enter 40 to program a PABX Access Code or to Disable Call Waiting LynxSIA Plus only Enter 94 to program the downloading computer phone number Press the ESCAPE OFF key to enter Voice Prompt Program mode The system will announce Programming use arrowsto scroll choices press select to accept press escape to quit The system will announce the available options 5 Follow the directions provided by each voice prompt to make your selections 4 6 When you have completed each programming procedure the system will return to the Main Programming Menu Viewing data fields 1 To view data entered in field press plus the field that you wish to view e g 21 The system will beep three times and data programmed for that field will be displayed to the right of the field number The system will scroll through the data for longer numbers and a beep will sound after each number is displayed or three times after the final digit is displayed The FU NCTION key can be used to repeat a voice prompt as required Continued on reverse side 2 Corporate Center Drive Suite 100 Honeywell P O Box 9040 Melville NY 11747 Copyright 2009 Honeywell International Inc www honeywell com security Programming Notes Entering Voice Prompt Programming Power
8. nds 1 Delay Door Location Front Back Sliding Hall Side Kitchen Basement Add a Window Motion Detector or Fire Detection Sensor Select sensor location See 3 Press SELECT Entering Central Station Account Numbers Enter 0 9 11 B 12 C 13 D 14 E 15 F key Used to scroll forward through menu choices To add Select Activate l location modifier transmitter descriptors for the modifier Loo See 4 twice programmed sensor Press Press Press SELECT SELECT ADD Activate transmitter l To enroll twice transmitter L a Select Select sensor type Add Sensors See 2 Press Press SELECT SELECT System announces key Used to scroll backward through menu choices Programming Zone Types The Voice Prompt Programming feature can not be used to program Zone Types 02 05 10 14 and 24 Programming these zone types must be done using the Expert Programming Mode FUNCTION key Used to repeat a voice prompt This function cannot be used while entering phone or account numbers System announces descriptors for the programmed sensor 2 Sensor Type Window Motion Detector 3 Sensor Location Living room Kitchen Dining room Hall 4 Location Modifiers Upstairs Downstairs Attic Office Second Floor Front Family Room Guest Room 6a Add Sensors Continued Add an Emergency Pendant Select pendant type See 5 Activate transmitter twi
9. up the control and enter the Installer Code 8 8 8 When you have completed each programming procedure the system will return to the Main Programming Menu 5 Voice Prompt Programming 6a Add Sensors Add a Door Sensor Navigating the Voice Prompt Programming Mode Scroll through the voice menu and follow the instructions provided to continue using the Voice Prompt Programming Mode The following keys are used to navigate through this feature 1 ESCAPE OFF key Used at any time to exit the current menu and return to the previous prompt ADD AWAY key Used to add sensors or keys or save data when entering phone or account numbers DELETE STAY key Used to delete a sensor when in the delete Sensors Menu SELECT AUX key Used to confirm a selection The Lynx Plus Series will enroll a sensor once the transmitter has been activated two times The system will confirm the enrollment following each subsequent activation of the same transmitter Activate transmitter twice Select delay Select door location Add Sensors See 1 Press Press Press Press SELECT SELECT SELECT ADD Garage Patio System announces descriptors for the programmed sensor Select Delay Door Exiting Voice Prompt Programming Once you have returned to the Main Programming Menu press the ESCAPE OFF key Entering Central Station Phone Numbers Enter 0 9 11 x 12 13 a pause of 2 seco