1. Page 10 The R FR 5010 R FR 5011 is a high quality 2 RU high 19 inch rack frame enclosure for the LYNX Series 5000 CardModules designed primarily for broadcast and professional applications The rack frame can accept up to 10 Series 5000 CardModules plus an optional controller card All modules are installed from the front Module connection plates are supplied with each CardModule and are mounted on the rear of the rack to align CardModule installed All CardModules and power supplies are hot swappable The R FR 5010 R FR 5011 features connections for remote alarming serial control and a local extension port ALAN connection is also provided for use with the optional R CT 5030 Master Controller Optional redundant power capability can be installed and two separate AC power connections are provided for maximum isolation The power supplies have sophisticated power filtering with microprocessor control for power monitoring and communication with the control system An on board multifunction LED has various states to indicate different alarm conditions and a separate GPO alarm output is provided for connection to an external monitoring system The system is convection cooled plus forced air cooling low noise fans so it can be used in areas where noise level is critical Power supplies have a small temperature controlled DC micro fan which is only used when needed and is also low noise when operating The R FR 5011 ra
2. Power Supply The R FR 5010 R FR 5011 includes the primary power supply second identical power supply can be added for redundancy The Power supply is a sophisticated design designed for critical applications and includes power filtering and integral microprocessor This monitors the supply operation and reports into the control system Should a fault develop the errors are alarmed in the following ways e Via the LED located on the front of the supply Figure 4 e Via a GPO alarm via the alarm connector on the termination panel figure 5 if a controller option is fitted e Via the control system if installed If the redundant power supply is installed the system will switch supplies automatically in the event of primary supply failure with no interruption to the normal operation of the rack The supply has a noiseless integral DC fan for cooling The supply is installed and removed from the front of the rack Removing the rack front cover plate provides access The supply is secured firmly in place with a screw located at the bottom front of the unit figure 4 Page 14 Integral Fan Handle for removal D LED Alarm indicator gt 0 gen Securing Screw Power Supply seen from Front Figure 4 Power Supply Page 15 Reference Manual R FR 5010 Version1 4 Rear Termination Panel The R FR 5010 R FR 5011 has an integral termination panel on the rear of the rack for the conne
3. into the rack and make sure the edge connector from the CardModule is aligned correctly with the connection plate When alignment is correct tighten the two screws Remove and insert the CardModule a few times to check installation If the CardModule sticks or installation is in anyway difficult loosen the connection pate screws and check alignment Repeat this process for each CardModule Note It is important to note the order of the CardModules on the front of the rack Redundant Power Supply The basic RFR 5010 R FR 5011 is supplied with the primary power supply installed The redundant supply option is installed next to the primary supply Remote Controller Depending on your system design you may have one of the LYNX controller options available RCT 5010 R CT 5020 or R CT 5030 Install the controller into the first module slot next to the power supply s Please refer to documentation supplied with the controller CardModule on the configuration and use of the LYNX controller options Page 25 Reference Manual R FR 5010 Version1 4 ejdwexa ue jsnf si umoys U01 99J8S xew DL Sue 4981 UO pajunou sjaued uoosuuo I 1281 a npoN N FR SS aj P doo las paaa TF yz 1no De D mon a mo pin S A doo ias no pua s A Figure 10 Rear Rack with connector plates ES a E o LYNX Tochik AG E a Ei LYNX Tockmik AG 8 BIT SDI TO ANALOG CONVERTER a EI a 2 o yno pia
4. our web site for more product information LYNX TECHNIK AG Notes Page 39
5. s A oo E y O 0 mo01 9 mo SAAD z dool jas E D no SEAD 5 Y mo as dool as zmoias zno Jas z mo jas 6 so oo o AA A s CARE Mozeevva zizexad ooe vao coos vao DUAL AUDIO ANALOG DIST AMP DUAL AES AUDIO DEMULTIPLEXER al 00000000 0000000 y A E o y I E Le mo sand 6 N Ss 7 O 2109q suoyon4 su uopejjejsuj 88S NOILN E o E E OD EI DUAL SDI DISTRIBUTION AMP 8 BIT SDI TO ANALOG CONVERTER 8 BIT SDI TO ANALOG CONVERTER DUAL SDI DISTRIBUTION AMP Sy z 0 0 0 a E wo DUAL SDI DISTRIBUTION AMP DUAL SDI DISTRIBUTION AMP o 8 3 5 o 2 ES a 3 E Es E DUAL ANALOG AUDIO DISTRIBUTION AMP ox a Q SISSeyo 0 ejd uoljoeuuos andes woyoq eu u suo pue do y ul suo eweg Burjunow OM Spied jnpow p jjezsu y9 eu 0 p zunow sjaued uor2eouuos 189 Page 26 Hot Swapping Power Supplies The Series 5000 CardModules and Power Supplies are fully hot swappable in the event of a fault or failure Power Supply Failure A failure in the Primary power supply will automatically trigger the use of the redundant supply if fitted and will trigger the following alarm conditions indications requires controller option e Reported fault on the monitoring system e Alarm GPO trigger on the alarm connector see Alarm Connections section e
6. zum Trennen leicht zug nglich sind ACHTUNG Das Ger t ist nach der Schutzklasse aufgebaut Vor der ersten Inbetriepnahme muss sichergestellt werden dass der Schutzleiter mit dem zentralen Schutzleiter des Geb udes verbunden ist und spannungsfrel ist Der Erdanschlussbolzen an der Netzanschlussr ckseite ist intern mit dem Schutzleiter verbunden Falls erforderlich kann er f r den Potentialausgleich mit anderen Ger ten verwendet werden Page 33 Settings and Control Page 34 There are no specific setting and control parameters for the card rack This is provided via controller option if fitted and the individual CardModule assemblies Please refer to the reference manuals supplied with these items for details on specific settings and controls available Reference Manual R FR 5010 Version1 4 Specifications R FR 5010 R FR 5011 Size 2 RU high x 32 5 cm deep including connectors and front cover 31 cm without front cover Standard 19 rack mount Weight empty R FR 5010 4 kg with single power supply R FR 5011 4 25 kg with single power supply Connections All connections made on rear of rack Performance Available Card Slots 10 x CardModules 1 x Controller 2 x Power Supplies primary and redundant Power Indication alarm One multifunction LED per supply and GPO output Fan Alarm through front cover R FR 5011 only Module alarm LEDs visible through front cover Controller alarm LED bar Connections rear co
7. 55103 2 1996 EN 60950 2001 following the provisions of 89 336 EEC and 73 23 EEC directives Winfried Deckelmann eee 7 ER Weiterstadt January 2004 Place and date of issue Legal Signature USA FCC 47 Part 15 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to the part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in aresidential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Page Contents WOMAN aiii Regulatory information ss 7 EUITIO sais 7 Declaration of CONO 7 Contents nono A Getting Started WEEN 10 PARADIS rs i 10 Prod ct Re DEE 10 RACK Layout ia 12 Power SUDDIY EE Rear Termination Panel 16 Rack COMES Me duds ae nr 16 Power Connection E
8. Alarm LED Status Indicators There are a number of status alarm indicators visible through the front panel of the R FR 5010 Rack frame Figure 9 Thumbscrews to remove cover Fan Alarm LED R FR 5011 only eries 5000 Individual Module Alarm Function is determined by the module installed Please refer to the manual for the specific module Controller Function Continuos up and down cycle of LEDs indicates _ normal operation If a gt problem occurs then the LEDs will freeze with a certain pattern indicating the fault condition Please refer to the controller manual for details OOOO OO OOO kA BEK BOK a JEK JOK KA kA ra 600 0 0 EA JEK Sr e 6 9000000000000000 60 0 0 0 0 0 EOS EA JEK JEK JEK KA kA 000000000000000 000000000000000 KE EF PA PA EA EA EA EA FA FA PA PA PA EL 0 KT EL SA KA kt KA KA kA KA A KA KSC ra ka e ri ra rr ka kA EA EA EA SA PC ra KA OOOO OOOO OOO OOD PS 8 8 8 SCC rr rt OOOO ROC ECONOMIC DAC e FA SA PA PA PA PA EA EA EA PA 6 0000000000 ze a Power Supply Indicators One LED per supply Primary and Redundant refer to table below for indication states Figure 9 LEDs and indicator locations and function Page 22 Reference Manual R FR 5010 Version1 4 Power Supply LED Indicators The Table below shows the error conditions for the LED on the power supply units These are visible through the ventilation holes on the left side of
9. E 16 Alarm Connection ER na ee 17 Alarm Runcti n seen 18 ESPIAS 19 Control Connection ESA SRE deco 20 LAN Cometa 21 External Sync Connection nr 21 Alarm LED Status Indicators 22 Power Supply LED Indicators 23 Fan Alarm LED OR FR 5011 only 23 Rack Configuration sense 24 O 24 Rack Layout Considerations 24 Rear Connection Plates nee 24 Redundant Power Supply ss 25 Remote Controller AAA dd re 25 Hot Swapping DEES 27 Se TEE 27 Power Supply Falta 27 Card Module tes RE eben 27 ie teil te UE e BEE LOCAAOM A ee 28 E e 28 Mechanical Installation ccccccccnnnnnnnnnnnononancnnanananananacanananon 29 Front Panel Removal R FR 5010 29 Front Panel Removal R FR 5011 29 Page 8 Electrical Installation ooooocoocooccocooccoccoccnccnncnocos 31 Installation Instructions 32 Installations Anweisung ss 33 Settings and Control dao 34 Specifications R FR 5010 R FR 5011 35 Available OPTIONS nine sense 36 Parts LISE le ed email vestes 37 A 37 Contact Information anne een 38 Page 9 Get ting Started Packaging The shipping carton and packaging materials provide protection for the module during transit Please retain the shipping cartons in case subsequent shipping of the product becomes necessary Product Description
10. Front Panel LED normally green will go out See Alarm Status indication section Once identified the defective supply can be removed and replaced with power connected with no interruption to the operation of the CardModules CardModules If a CardModule fails the error will be reported over the monitoring system and via the front side alarm LED Alarm function is module dependant so please refer to the CardModule manual for failure conditions and indications The defective CardModule can be removed and replaced with an identical replacement without removing power from the frame Page 27 Rack Installation Page 28 If you have an empty R FR 5010 rack frame we recommend you assemble the connection plates and modules as well as any options such as the redundant power supply and controller before mounting the Rack Frame into a 19 inch rack Please refer to assembly section Location The R FR 5010 Rack frame can be located anywhere there is available 19 inch rack space The rack will take up 2 Rack Units RU of vertical rack space Ventilation Depending on the installed modules up to three R FR 5010 rack frames can be mounted stacked with no space in between Allowance has been made in the design providing space between the racks for adequate air ventilation Every third rack there should be 1 RU space provided for additional airflow NOTE In case of modules with higher power dissipation e g P VD 5010 appropri
11. LYNX TECHNIK AG Ver 2 0 Reference Manual R FR 5010 R FR 5011 Series 5000 Rack Frame LILLO HHH us Dan A IAS wn LU HELM u m m m m mw wm won DUH UHH 54 ee wn ml PT HHH LA SE ap 333 333 223 a za za ri Page 2 Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without express written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except as expressly written by LYNX Technik AG the furnishing of this document does not give you any license to patents trademarks copyrights or other intellectual property of LYNX Technik AG or any ofits affiliates LYNX Technik AG 2002 2005 all rights reserved WARNING Electrical supplies in excess of 50 fifty volts peak value are potentially hazardous or lethal AC supplies between 100 and 250 peak volts exist within the rack frame chassis when connected to AC power Only qualified personnel should service the rack frame assembly Removal of technical earth may render the equipment dangerous and intentional removal is prohibited This unit has to be separated from mains by disconnecting the power supply cords This unit may have two power supplies and two power supply cords D
12. ate cooling is required We recommend in these cases to add 1 RU space in between each rack The R FR 5011 with a front cover with integrated fans should be used for critical applications where external cooling is not sufficient Note Airflow through the R FR 5010 rack frame is from bottom to top Forced fan cooling may be required in case of modules with higher power dissipation Please consider other surrounding equipment when designing rack layout Placing the R FR 5010 directly above another piece of equipment with heat exhaust from the top may cause the Card Modules to malfunction due to excessive heat Like wise if placed below another piece of equipment with bottom air intake the R FR 5101 rack frame may due to the small airflow gap restrict the flow of air to this piece of equipment Also do not place equipment or objects on top of the R FR 5010 rack frame that could restrict airflow from the top of the rack This may cause malfunction and damage due to excessive heat buildup Mechanical Installation The R FR 5010 R FR 501 1 is secured into a standard 19 inch rack using 4 standard rack screws Remove front cover panel for installation which allows access to the rack ears figure 3 shows location Rear support of the rack using rack rails is recommended but not necessary Front Panel Removal R FR 5010 The front panel is removed by simply rotating the thumbscrews one turn counterclockwise and pulling the panel outward
13. aufrechtzuerhalten sind bei Sicherungswechsel nur Sicherungen des gleichen Typs mit gleichen Daten zul ssig Fl F4 T2AH250V Page 4 This Page is intentionally left blank Page 5 Warranty Page 6 LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of two 2 years from the date of shipment If this product proves defective during the warranty period LYNX Technik AG at its option will either repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product In order to obtain service under this warranty customer must notify LYNX Technik of the defect before expiration of the warranty period and make suitable arrangements for the performance of service Customer shall be responsible for packaging and shipping the defective product to the service center designated by LYNX Technik with shipping charges prepaid LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located Customer shall be responsible for payment of all shipping charges duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under th
14. ble from the rack This is a 9 pin SUbD male connector Function and connection information is described below rin Connection Pin Connection Number gt Number GND Shield E INC Alarm Major GPI in A GND Shield GND 3 AlamMinr_ 8 GPIinB EM Figure 6 Alarm Connector Page 17 Page 18 Alarm Function This function requires the controller option The user can assign triggers for the preferred Major Minor and No Alarm conditions using the controller and supplied software The alarm connector provides GPO contacts for 2 alarm levels and a GPI input for future use This allows for the connection of an external monitoring system Alarm conditions are triggered by the optional control system and will vary depending on the configuration of the system and user preferences For critical failures in the rack a contact can be closed between Alarm Minor and Alarm Common Some examples of critical type failures are listed below e Over temperature e Redundant Power Supply Failure For major failures in the rack a contact can be closed between Alarm Major and Alarm Common Some examples of major failures in the rack are e Loss of Power Extend Connection Bus Extension This connection is used to interface racks together when using the optional LYNX control system This is a simple and inexpensive way to extend the reach of the host RCT 5020 controller into several more ra
15. ck frame has a front cover with integrated fans for applications where no external forced cooling is available or if modules with high power dissipation are used in this rack frame All electrical contacts inside the R FR 5010 R FR 5011 the CardModules and power supplies are gold plated ensuring maximum reliability and protection from corrosion The R FR 5010 is the primary building block in the LYNX Series 5000 CardModule system that provides high quality modularity and flexibility in a very small form factor Page 11 Reference Manual R FR 5010 Version1 4 Rack Layout Figure 2 and 3 shows exploded views of the R FR 5010 R FR 5011 The Front cover is removed and not shown Caution Do not obstruct ventialtion holes on top and bottom sides of rack Refer to mounting instructions for more details A Mounting rails on rear of rack for connection panels Mid Rack Vertical Support Figure 2 Exploded rack view Page 12 Reference Manual R FR 5010 Version1 4 Caution Do not obstruct ventilation holes on top and bottom sides of rack Refer to mounting instructions for more details Support CardModule Note Exploded views are shown for reference only It is not necessary to disassemble the rack as shown Figure 3 Exploded rack view For clarity to show rack construction power supplies rear termination panel and connection panels for the modules have been omitted Page 13
16. cks fitted with RCT 5010 bus expanders lt uses a proprietary LYNX control interface and this connection is physically daisy chained between all connected racks Connection details can be seen in the table below The connection is a 9 pin SubD female connector Function and connection information is described below Connector wiring detail when used for the Bus Extension Pin rs me mas Pin EE Number Connection Number Connection 1 PropCLKA 6 Prop CLKB 2 PropTXA 7 Prop TXB 3 Prop RXB 8 PropRXA 4 on Prop SEL 2 Prop SEL 1 Note the prop term refers to proprietary for the LYNX interface 4 Figure 7 Extend Connector Note When using this interface all connected racks must be mounted close together preferably with no space in between racks as the distance of this interface is restricted Please refer to the R CT 5010 Rack Bus Expander reference manual for more details on this interface and the cables required Page 19 Reference Manual R FR 5010 Version1 4 Control Connection An external Control Interface is provided on the rear termination panel When an R CT 5020 Rack Controller or R CT 5030 Master Controller is fitted to the rack this port can be used for two primary functions 1 When configured as a RS 232 serial port this can be connected directly to a PC running the LYNX control software 2 When configured for RS 422 operation this port is used to daisy chain oth
17. ction of power and various other connections for expansion and interfacing Figure 5 Ox TEND CONTROL a a or Th s umit has more than one po supply cord Disconnect both power supply cords before servicing to void electrical shock E E gt d Only with same type and rating of u against risk of fire replace fuses CAUTION Double pole T2AHISOV ral fusing Figure 5 Rear Panel Connections Rack Connections Power Connection There are two power connections provided for the rack One is for primary power and the other for the optional redundant power supply Input power range is 100 to 240VAC 50 to 60Hz Connection is made using an IEC power cable For systems without redundant power connection is made to ACT in only The power fuse is in the connector assembly Figure 5 and removal of this small module will enable fuse exchange Please ensure you use the correct fuse rating 2A Page 16 A stud is provided on the termination panel for the connection of an external ground Figure 5 Note the chassis is permanently grounded via the AC connections Caution Service to be performed by qualified personnel only Caution Please remove power before attempting to exchange a power fuse Only replace the fuse with a correctly rated replacement For safety DO NOT physically disconnect or isolate the rack from earth for any reason Alarm Connection An external alarm connection is availa
18. e parts list below shows high level sub assemblies used in this rack which can be ordered separately for maintenance purposes R FR 5010 Rack Frame complete Description Series 5000 Rack Frame Model Number R FR 5010 Part Number 6 155 001 000 Main sub assemblies Main term panel Part Number 6 155 001 030 Front Cover Part Number 6 155 001 013 R FR 5011 Rack Frame complete Description Series 5000 Rack Frame Model Number R FR 5011 Part Number 6 155 002 000 Main sub assemblies Main term panel Part Number 6 155 001 030 Front Cover w fans Part Number 6 155 001 010 Service If you are experiencing problems or have questions concerning your R FR 5010 R FR 5011 rack assembly please contact your local distributor for assistance More detailed information and product updates may be available on our web site www lynx technik com You will also find links to contact us directly for assistance Page 37 Contact Information Page 38 Please contact your local distributor this is your local and fastest method for obtaining support and sales information Lynx Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets please contact your local representative or visit
19. ements of the country where the rack frame is used and has to be approved in this country e g e CE Mark in Europe e UL listed in USA e CSA certified in Canada CAUTION The power supply cords are used to disconnect the R FR 5010 R FR 5011 from the mains supplies make sure that the socket outlets are located installed near the equipment and are easily accessible CAUTION The rack frame chassis is a CLASS EQUIPMENT ensure before initial operation that protective earth is connected to the building wiring and zero potential is established The functional earth connection at the rear termination panel is connected internally to protective earth If necessary it may be used for potential equalization to other units Page 32 Installations Anweisung Das Ger t R FR 5010 R FR 5011 ist f r Anwendungen in Fernsehstudios vorgesehen Der Einsatz in erh hter staubiger und feuchter Umgebung oder au ergew hnlichen Temperaturen erfordert besondere Ma nahmen wie e Klimatisierung e Staubfilter e Vermeiden von Kondenswasser Die Netzkabel m ssen den Sicherheits Anforderungen in dem Land entsprechen in dem das Ger t verwendet werden soll und in dem Land zugelassen sein z B e CE Zeichen in Europa e UL gelistet in USA e CSA Zulassung in Kanada ACHTUNG Die Netzkabel dienen zur Trennung des Ger ts vom Netz Es ist sicherzustellen dass die Steckdosen f r den Netzanschluss in der N he des Ger tes angebracht und
20. er racks fitted with R CT 5020 Rack controllers up to 15 additional racks Note Please refer to the R CT 5020 Reference Manual for details on how to re configure the port and more detail on the use of this control interface The connection is a 9 pin SubD female connector Function and connection information is described below Connections for RS 422 Pin Pin Number Connection Number Connection 1 GND Shield Oe BND 2 TXA 422 7 TX B 422 3 RX B 422 8 RX A 422 4 GND 9 GND Shield 5 GND Connections for RS 232 Pin Connection Connection Number GND Shield 6 GND ___ TX 232 Figure 8 Control Connector LAN Connection This is a standard RJ48 connection and is used to provide standard TCP IP network control connectivity into a control system To be operational this port requires the R CT 5030 Master Controller is fitted to the rack Please see the reference manual for the R CT 5030 for more details on the use of this connection External Sync Connection An external sync reference loop through connection can be connected for the rack This provides a common genlock reference for the modules installed in the chassis Sync signal can be black or composite analog sync NTSC or PAL This is to provide a common reference to all modules installed in the rack and can simplify the distribution of the reference signal in some system applications Page 21 Reference Manual R FR 5010 Version1 4
21. is warranty a to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install repair or service the product b to repair damage resulting from improper use or connection to incompatible equipment c to repair any damage or malfunction caused by the use of non LYNX Technik supplies or d to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE LYNX TECHNIK S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTAL DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES Regulatory information Europe Declaration of Conformity LYNX Technik AG Brunnenweg 3 D 64331 Weiterstadt Germany Declare under our sole responsibility that the product TYPE R FR 5010 R FR 5011 To which this declaration relates is in conformity with the following standards Environments E1 E3 EN 55103 1 1996 EN
22. isconnect all power supply cords before servicing to avoid electric shock DOUBLE POLE NEUTRALE FUSING After operation of the fuse parts of equipment that remain energized might represent a hazard during servicing For continued protection against risk of fire replace only with same type and rating of fuse Fl F4 T2AH250V Replacement AC fuses must be of the specified type and rating Fl F4 T2AH250V The use of repaired fuses or shorting links is to be avoided WARNING CAUTION Page 3 WARNUNG Wenn das Ger t an das Wechselstromnetz angeschlossen ist treten innerhalb des Ger tes Wechselspannungen zwischen 100 und 250 V auf die potentiell gef hrlich oder t dlich sein k nnen Deshalb darf Reparatur und Instandhaltung nur von qualifiziertem Personal durchgef hrt werden Das Entfernen des Schutzleiters kann das Ger t in einen gef hrlichen Zustand bringen vors tzliches Entfernen des Schutzleiters 1st verboten Das Ger t ist durch Abziehen der Netzstecker vom Netz zu trennen Das Ger t kann 2 Netzger te mit 2 Netzkabeln haben Vor Servicearbeiten m ssen alle Netzkabel abgezogen werden um elektrischen Schlag zu vermeiden Die Netzzuf hrung 1st 2 polig abgesichert Nach Ausfall einer Sicherung k nnen Teile der Schaltung weiter unter Spannung bleiben und bei Servicearbeiten zu Gefahren f hren Vor Servicearbeiten Stromversorgung unterbrechen und Teile vor Ber hrung pr fen Um Schutz gegen Feuer
23. nnections LAN Connector RJ 48 Control 9 Pin female SubD RS 485 Extend 9 pin female SubD RS 232 Alarm Connector 9 Pin male Sub D GPO and GPI Ref In BNC connection for rack reference with loop output Primary AC IEC power connector fused 2A Redundant AC IEC Power connector fused 2A Electrical Specifications Power Input 100 240VAC 50Hz 60Hz Two separate and isolated connections for Primary and Redundant supplies Power Consumption 130W max Safety IEC 60950 EN 60950 VDE 0805 Temperature 5 C to 40 C Maintaining specifications 0 C to 50 C Operating Humidity Max 90 non condensing Supplied Accessories Documentation R FR 5010 R FR 5011 Reference Manual Page 35 Available Options Below is a list of available options for the R FR 5010 rack frame Please refer to product brochures or our web site for more detailed information Model Description RFR5010 Series 5000 Rack Frame empty with single R FR 5011 power supply R PS 5010 Redundant power supply for the R FR 5010 Card Frame R FR 5001 Front Cover with integrated fans for upgrade of R FR 5010 R CT 5020 Rack controller for the R FR 5010 Card Frame R CT 5030 Master controller with TCP IP Inteface for the R FR 5010 Card Frame R CT 5010 Rack Bus Extension for the R FR 5010 Card Frame In combination with R CT 5020 5030 Page 36 Parts List There are no user serviceable electronic assemblies within the R FR 5010 module Th
24. s Front Panel Removal R FR 5011 The front panel is removed by simply rotating the thumbscrews one turn counterclockwise and pulling the panel outwards If you put back the Fan Front Cover of the R FR 5011 please make sure that the 9 Pin Sub D connector is connected correctly see pictures below Page 29 Reference Manual R FR 5010 Version1 4 Fig 12 Sub D 9 Connector on right side of R FR 5011 Page 30 Electrical Installation Electrical power is connected to the R FR 5010 R FR 5011 chassis via the two IEC power connectors located on the termination panel on the rear of the rack There is no power switch provided Two separate and isolated power connections are available one for the primary power and one for the optional redundant power supply Primary power is connected to AC in 1 Caution Please remove power before attempting to exchange a power fuse Only replace the fuse with a correctly rated replacement For safety DO NOT physically disconnect or isolate the rack from earth for any reason Caution Service to be performed by qualified personnel only Page 31 Installation Instructions The rack frame chassis R FR 5010 R FR 5011 is intended for operation in broadcast environments The operation in excessive dust and moisture or extreme temperature requires special provisions like e dust filters e air conditioning e avoidance of condensed water Caution The power cords must meet the safety requir
25. the front of the rack figure 9 LED Color Condition Green Normal Operation Yellow Warning High Temperature Red Flashing Warning Over Temperature Red Continuous Warning Voltage out of range Failure Exchange Supply Fan Alarm LED R FR 5011 only The Table below shows fhe error conditions for the LED on the fan front cover of the R FR 501 1 This is visible on the right side of the front of the rack figure 9 LED Color Condition D Normal Operation all fans working 1 or 2 fans failed Red Continuous all fans failed Page 23 Rack Configuration Assembly Page 24 If starting with an empty R FR 5010 R FR 5011 rack frame please follow the following steps for correct installation of the Series 5000 Card Modules Rack Layout Considerations If you have a variety of module types it s a good idea to plan the order in which you install the various CardModules While a module can occupy any of the 10 available slots provided consideration can be given to the position of the modules in the rack to facilitate external wiring Figure 10 shows a layout example Rear Connection Plates The series 5000 CardModule is supplied with a connection plate and two screws This is fitted to the rear of the rack frame behind the module Position the connection pate on the rear mounting rails figure 2 and secure with the two screws provided Do not fully tighten the screws initially Test fit the module