Home
Lyngdorf Audio CD-1 User's Manual
Contents
1. 96 kHz with sample rate conversion e Stereo DAC output balanced and unbalanced e IR remote control e Firmware upgradeable from PC Performance e Frequency response L R 20 20000 Hz 0 02 dB e Signal to noise ratio A wgt infinity zero track 115 dBA e Dynamic Range A wgt output 60 dBFS 1kHz 100 dBA e Distortion THD N 20 20000 Hz 0 0018 e Crosstalk 125 16000 Hz 114 dB e Odb analog output level 3 8 Vrms e Unbalanced analog output impedance 75 Ohm e Balanced analog output impedance 100 Ohm Front panel Fig 1 CD 1 front panel Front panel controls and functions The buttons controls on the front panel of the CD 1 can all be used either by directly pressing them on the front panel or by operating the similar keys on the included remote control All keys on the front panel except the Mains switch 1 can be found on the remote control Additional buttons on the remote control include the following random repeat A B and the digits 0 9 Please note the left lt and right gt arrows in the center button area of the remote control work exactly like the Skip Search buttons lt lt gt gt on the front panel The play pause buttons and the Enter button also work in exactly the same way 1 Mains switch Powers the CD 1 on off 2 Standby button Standby mode this can also be selected on the remote control 3 Eject The CD Loader Tray can be opened and closed
2. Mains lead supplied Mains voltage range 100 120V AC 50 60Hz Mains selector on 115V Mains voltage range 200 240V AC 50 60Hz Mains selector on 230V Internal mains fuse T1Ah Power consumption 2 5W STANDBY mode Power consumption 20W OPERATE mode Playing CD 19 Mechanical Parameter Value Note Width 450mm 17 72 Depth 352 mm 13 86 including skip wheel excluding connectors Depth 357 mm 14 06 including skip wheel including connectors Height 89 mm 3 5039 Excluding feet Height 100 mm 3 9370 Including feet Net weight 7 1 Kg 1 65 lbs Shipping weight 9 1 Kg 6 06 Ibs Discs Parameter Value Note Compatible disc types CD DA CD R Compatible disc sizes 8 cm 12cm Other Non audio discs such as discs with DTS encoded sound can be played back via digital interfaces only and only at 44 1 kHz The connected amplifier needs to support the encoded format 20 Technical assistance If you have any problems with or questions regarding your Lyngdorf Audio product please contact Lyngdorf Audio or your nearest representative Support Please check the Lyngdorf Audio Denmark website under Support for latest version of control software newest version of this document and Questions and Answers Lyngdorf Audio Denmark Nordhavnsvej 12 DK7800 Skive Denmark E mail info lyngdorf com Web htt
3. the remote for operation with a Lyngdorf Amplifier RCS Selects the remote for operation with a Lyngdorf Room Correction System CD Selects the remote for operation with a Lyngdorf CD Player Tuner Selects the remote for operation with a Lyngdorf Tuner unit 11 Standby The standby button toggles the CD 1 between active On and standby mode Numbered buttons 0 9 The numeric keys allow direct selection and input of tracks on CD Left Right lt gt Allows you to Skip tracks and scroll through the menu functions Enter Allows you to confirm actions in menu mode When not in menu mode this button also functions like the play pause button Skip Scan lt lt gt gt Allows you to Skip to specific tracks Scan allows you to Search through individual tracks for a specific part of a track Stop Pressing stop during play or pause mode will stop the CD Play Pause Pressing the play pause button will start playing the CD Pressing the button again will toggle between play mode and pause mode A B This button is used for controlling the A B Repeat Mode Random Switches Random play mode on or off Repeat Toggles the CD 1 repeat function between None Repeat One and Repeat All Eject Opens or closes the CD loader tray 12 Main Display The Main Display on the front panel of the CD 1 is the users feedback of all functionality and current status of the CD 1 When the Player is powered up t
4. track number the Random Play mode will cause the CD 1 to create a new play list with the selected track as the first The CD 1 will then start playing this track Using the skip wheel 11 8 12 on the front panel or the Skip Scan lt lt gt gt buttons during Random Play mode will skip to the previous or next track in the random play list The skip functions will not skip past the beginning or end of this play list unless Repeat All is selected then the next and previous functions will loop around at the beginning or end of the play list Selecting Repeat All during Random Play mode will repeat the random play list after the last track in the list The play list is not affected Selecting Repeat One during Random Play mode will repeat the current track playing without affecting the play list If the Stop button is pressed during Random play mode a new random play list will be generated when Play mode is entered again Turning Random Play mode off and on again will cause the CD 1 to generate a new random play list Repeat mode Selecting Repeat mode will allow the CD 1 to skip to the first track again when the end of the last track is reached Repeat One mode Selecting Repeat One mode will allow the CD 1 to restart playing the track when the end of that track is reached Rear panel OUTPUTS O r JM crass 1 LASER PRODUCT Fig 2 CD 1 rear panel 1 amp 2 Analog output right and left RCA Comn
5. using the eject button If the button is pressed during play mode the disc will be stopped before the tray is opened 4 The CD Loader Tray While the tray is opened pressing play will cause the tray to close and start playback Selecting a track with the digits on the remote control will also close the tray and start playback at the selected track 5 Indicator light Power on indicator LED 6 Play Pause Pressing the play pause button or the skip wheel 11 amp 12 see below instructions will start playing the CD Pressing the button again will toggle between play mode and pause mode You can select a new track with the skip buttons the skip wheel 11 8 12 see below instructions or directly with digits during pause mode This will cause the CD 1 to position J itself at the start of the selected track but it remains in pause mode until the play pause button is pressed again 7 Stop Pressing stop during play or pause mode will stop the CD 8 amp 9 Skip Scan Pressing briefly on the Left lt lt Skip Scan button or turning the skip wheel left will restart the current track or if currently playing within the first two seconds of the current track skip to the previous track Turning the skip wheel right or pressing shortly on the gt gt button will skip to the next track Skipping left from the first track will always restart this track while skipping right from the last track will have no effect unless the C
6. wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as when the power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on the apparatus 16 To completely disconnect this apparatus from the AC Mains disconnect the power supply cord plug from the AC receptacle 17 The mains plug of the power supply cord shall rema
7. CD 1 Compact Disc Player Owners Manual BANIGDORF Table of Contents WARNING S E eN 3 Explanation of graphical symDoIs 0 eeeeeccceessececeesseececesseeecesssneeecseaeecessuaceeesssaeeceesaeeceesneeeeeaaes 3 Important safety iNstructiONS ce eesececesssecceessneeecessteececessaeecesseaeeeessaeecessueeeessssatecesesaeeeeeeaeeeesenas 4 Unpacking the CDA A a a A T 4 ACCES a a A ES 5 Operating Volta id rr A it did id tada 5 Product Registrations mrene A A 5 TIO AA A A tE AS 6 Front PM A a A geen iss 7 Front panel controls and functions ocoococcconoccccnnonacncnnnoncnnnonnnnnononnnnnnnonnnnncnnnnnnnnnnn nano nnnn iaa ae Seenaa 7 A A NN 10 Remote Co e eee a Rees 11 Main Display cesses seditacstestuase os bcsusnesavalagiestesdanenis ceca gives A EE wan E A EEEE a EE 13 Menu System Displaynv cestissescrseiteessetestedelagonsctestenuecasss bees lonebepaeghseastsatadageezded E na A A E ea CREEA 15 Firm Ware A AO A A A A EE 17 COMME CLOTS at nag thats a a E saves A T A as do 17 Mans Comme Ctor EEEE E E EE E E A E 17 Analog Uttar re Aea a aaa a ronte taae gioa 17 Digital Outputs adas 18 Cleaning andimaintemance cies A te Ah ee cae ae ed eg ence 18 Technical Specifications iii ad EE AAE EEE aA EEn 19 O ET E E E Ss diana 19 ProtectiOn ce 88 A A aaa se a 19 MAS A Wa eign iu a i eeepc 19 Mechanical adi 20 A OS OSO tess 20 echnical assistance innr a Ra a a a Ae a aaa A aha na EEA EE AE E AE ER E A
8. D 1 is in Repeat All mode In this case the CD 1 will loop around to the last first track Holding the lt lt or gt gt buttons down for more than half a second will start the CD searching Scan in the indicated direction The CD starts at approximately twice the normal speed but after a few seconds the speed will increase further Searching Scan past the end of the disc or before the start of the disc will stop the disc playing unless the CD 1 is in Repeat All mode In this case the disc will loop around to the start or the end of the disc 10 Menu functions In the menu there are several options for setting up the CD 1 press Menu to enter In the main menu the different menu items can be selected with the lt lt and gt gt keys or with the skip wheel Once the correct menu item has been found pressing the play pause button or the skip wheel will enter the sub menu In the sub menus the current value of the setting is shown A new value can be selected using the lt lt and gt gt keys or the skip wheel To accept the change press the play pause button or the skip wheel Pressing the menu button again or selecting lt Exit Menu gt will exit the menu without saving changes 11 amp 12 Play Select also referred to as the Skip Wheel The Play Select button is a skip wheel which allows you to Skip left lt lt and Skip right gt gt by turning the wheel in either direction The button in the centre works in
9. a E SS 21 DUPPOLE orea a Teel ede a E wed E T a h O ET EE Maeda 21 WARNINGS CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE Explanation of graphical symbols Exclamation symbol A The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Lightning symbol The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated Dangerous Voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electrical shock to persons Important safety instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat 9 Do not defeat the safety purpose of the grounding type plug A polarized plug has two blades with one
10. ectors 3 amp 4 Analog balanced output right and left XLR Connectors for balanced output 5 Optical output Toslink Connector for digital output 6 AES Output XLR Connector for AES output 7 SPDIF SPDIF output 8 RS232 INPUT AUX AUX and INPUT RJ45 connectors The RS232 communication connectors are for communication to a PC or remote control from Lyngdorf equipment with broadcast commands or linked control between other components The Input is looped to Aux for daisy chaining of components The INPUT is used for connection to a PC computer to upgrade the firmware 9 MAINS INPUT 1EC320 type connector 10 POWER MODE SELECTION SWITCH The CD 1 has a large switch above the MAINS INPUT 9 selected to the correct voltage for your location or Country s power supply This switch is selected to either 115V or 230V operation been selected for the voltage in your location or country Failure to do this may result in serious damage to your CD 1 component WARNING Always check the correct voltage 115V or 230V operation has 10 Remote Control The remote control is used to access the menu system and replicate the buttons directly accessible on the front panel The four buttons used for selecting which device to control are described below To control the CD player the CD key should be pressed please note the volume and mute buttons will still work with a Lyngdorf Amplifier even in CD mode Amp Selects
11. exactly the same way as the play pause button During play mode it toggles between play and pause In the menu mode the button is used as the select function A B Repeat mode A B Repeat mode is entered by pressing the A B button on the remote once to mark the start time A then pressing it again to mark the end time B Pressing the A B button a third time will return the CD 1 to normal playing mode Using other functions such as skip scan or direct track selection from the remote control will also exit to normal playing mode If the A B button is pressed during Random mode and or Repeat One mode these modes will be cancelled A B Repeat mode is indicated in the lower left hand corner of the display When A time has been set and CD 1 is waiting for B time the symbol A will be displayed Once B time has been selected and the CD 1 is playing in A B Repeat mode the symbol will be changed to AB Random Play mode When the Random button is pressed on the remote control or Random mode is activated in the menu the Random Play mode is entered and CD 1 creates a random play list This starts playing from the list instead of playing the tracks in numeric order If a track has already been selected or a track is playing this track will automatically become the first in the random play list so no new track is selected by enabling Random Play mode Using the number buttons on the remote control to select a specific
12. he Main display screen shows the current firmware version If no disc has been inserted the following text will appear When opening the tray the display will indicate this The next screen will show the Tray Open ready for you to carefully insert a compact disc The screen will state Closing when you have placed a disc into the empty tray and pressed the eject button or the Play Pause button The next screen states Reading this means the CD 1 is reading the TOC Table of contents of your compact disc When table of contents has been read the CD 1 will display the number of tracks and the total playing time of the CD When playing the CD 1 will display the current track the number of tracks and the elapsed time of the current track Track time is displayed as it progresses through the track 13 When skipping between tracks the time will disappear and be displayed again once the requested track has been found If you press pause the CD 1 will display the time at which the track has been paused Pressing A B on the remote control will show A in the bottom left hand corner of the display this indicates that the start time has been selected and the CD 1 is now waiting for the stop time Once A B has been pressed again and the CD 1 is playing in A B Repeat Mode the display will show AB in the bottom left hand corner of the display When CD 1 is playing in Repeat All mode rep is dis
13. in readily operable 18 Do not expose batteries to excessive heat such as sunshine fire or the like 19 Do not connect any output from this Compact disc player to any other Compact disc player s output or any other voltage source Unpacking the CD 1 Carefully remove the unit and accessory kit from the carton visually check for shipping damage Contact both the shipper and Lyngdorf Audio immediately if the unit bears any sign of damage from mishandling All Lyngdorf Audio equipment is carefully inspected before leaving our factory the unlikely event that the unit needs servicing If this unit is shipped without the KEEP SHIPPING CARTON AND PACKING MATERIALS for future use or in original packing damage could occur and void the warranty Accessories You should find the following in the accessory kit o A One mains cord This manual Customer registration form Remote control RS232 Cable for firmware upgrade from a PC Operating voltage The CD 1 is selectable to one of the following power ratings 100V 120V at 50 60Hz with a power rating of 20W 220V 240V at 50 60Hz with a power rating of 20W label and the setting shown on the voltage selector switch The warranty WARNING Connect the power input only to the AC source printed on the will not cover any damage caused by connecting to the wrong type of AC mains The CD 1 has three power modes 1 ON The power button will turn the CD 1 on The CD 1
14. p www lyngdorf com 21
15. played in the bottom right hand corner of the display Repeat One mode is indicated by the text rep1 in the lower right hand corner of the CD 1 display Random mode is displayed as shown below rnd stands for Random 14 Menu System Display The Menu system shown in the display of CD 1 is the user s feedback of all functionality in the menu and sub menu system When entering menu mode the first item is shown as The user can browse through the menu items using the right and left arrows or the skip wheel The available menu items are The functionality of each of the menu items are Chooses the sample rate of the digital outputs 44 1 kHz 16 bit no sample rate conversion e 48 kHz 24 bit e 96 kHz 24 bit default e 192kHz 24bit Adjusts the gain on the analog outputs in 0 5 dB steps from 6 0 dB to 0 0 dB Enables or disables the analog section of the CD 1 hardware 15 Selects the address used for the CD 1 when communicating with PC s or other devices via the RS 232 port Selects the speed used when communicating with PC s or other devices via the RS 232 port Disables or enables the IR remote control The brightness of the display can be set to 25 50 75 or 100 Chooses repeat mode No repeat repeat one track or repeat all Disables or enables random mode Exits the menu when selected e Firmware Lyngdorf Audio supplies a free PC tool for upgrading the firm
16. plug the unit from the electrical outlet before cleaning This unit does not require any regular maintenance except to keep its exterior clean Simply wipe its exterior with a clean soft cloth A small amount of non abrasive cleaner may be used on the cloth to remove any excessive dirt or fingerprints Do not use abrasive cleaners or cleaners containing liquid solvents 18 Technical specifications All audio measurements except frequency response are measured with a 20KHz low pass filter in accordance with AES 17 Measured on Unbalanced outputs RCA phono Audio Parameter Value Note Frequency response L R 0 02 dB 20 20000 Hz Signal to noise ratio 115 dBA infinity zero track A wgt Dynamic Range 100 dBA output 60 dBFS 1kHz A wgt Distortion THD N 0 0018 Crosstalk 114 dB 125 16000 Hz Odb analog output level 3 8 Vrms Unbalanced analog output 75 Ohm impedance Balanced analog output 100 Ohm impedance 3 digital outputs AES SPDIF Toslink Selectable sample rates on digital outputs 44 1kHz 16 bits 48 96 192 kHz 24bits Protection Parameter Value Note Grounding Mains earth chassis and audio ground are connected internally Over temperature All heat sinks and mains Auto resetting thermal fuse in transformer mains transformer Mains Parameter Value Note Mains input connector IEC 320 cold type
17. ware of the CD 1 The latest revision of the tool as well as the firmware can be downloaded from www Lyngdorf com Connectors Mains Connector Mains voltage to the CD 1 is applied via an IEC320 type connector The supplied cable with safety ground should be used to connect the CD 1 to a mains outlet A WARNING Connect the power input only to the AC source printed on the label and the setting shown on the voltage selector switch The warranty will not cover any damage caused by connecting to the wrong type of AC mains WARNING Always check the correct voltage 115V or 230V operation has been selected for the voltage in your location or country Failure to do this may result in serious damage to your CD 1 component WARNING Always disconnect the CD 1 from the mains before changing any connections to its inputs or outputs Analog outputs The unbalanced RCA outputs are wired in accordance with normal practice Shell Chassis and ground Pin Hot Unbalanced analog output impedance 75 Ohm The balanced XLR outputs are wired in accordance with IEC268 Pin 1 Chassis and ground Pin 2 Hot Pin 3 Cold Shell Chassis and ground Balanced analog output impedance 100 Ohm 17 Digital outputs RCA output SPDIF Shell Chassis and Ground Pin Hot XLR output AES Pin 1 Chassis and Ground Pin 2 Hot Pin 3 Cold Shell Chassis and Ground Toslink Cleaning and maintenance Always un
18. will start up in standby mode STANDBY The standby button will put the CD 1 in standby mode or bring the CD 1 back from standby mode If standby mode is requested while the tray is open the CD 1 will close the tray before entering standby mode OFF After Power off or Standby the settings of CD 1 are retained If the CD 1 was in random mode and or repeat all mode this mode will also be retained Please note that some parts of the mains entry section still carry live mains Product Registration Please record the serial number of your product here for future reference The serial number is printed on the label on the CD 1 rear panel You will need this serial number should you ever require service for your CD 1 Compact disc player CD 1 serial number Audio so we can register you as owner of the unit and keep you informed of Please fill out the enclosed customer registration form and submit it to Lyngdorf future upgrades of the product Introduction Lyngdorf CD 1 is an audio optimized upsampling Compact Disc Player with low jitter clock and a High Performance DAC section Features e Audio optimized CD transport mechanism with low jitter clock e Linear Low Noise power supply based on Holmgren Transformer technology e 3 digital outputs AES SPDIF Toslink selectable sample rate 44 1 48 96 192 kHz e Transformer coupled digital interconnects eliminates ground loops e High Performance DAC section operating at
Download Pdf Manuals
Related Search
Related Contents
Manual de Instalación ECG de 24h 20.10.2015 No.1528 - 国立病院機構 仙台医療センター Eiqueta Web - Ecuador CUIDADO MKZ Primer MKZ Primer MKZ Primer ED9532NV User Manual Copyright © All rights reserved.
Failed to retrieve file