1. within measuring range 89 6 F 109 3 F or 32 0 C 42 9 C the temperature will be displayed If ameasurement is above measuring range Hi will be displayed If below measuring range Lo will be displayed 6 The measurement will be displayed for approximately one minute then the 2216 will return to clock mode 7 The digital display will shut off automatically three minutes after the last key press Switching Between F and C To switch between measuring in F and C insert an unfolded paperclip or similar object in the button hole labeled C F on the back of the thermometer Fig 2 Memory Recall Recorded readings may be scrolled through while the thermometer is on To scroll through readings press the Memo button If no reading is stored in any ofthe 30 available memories the display will read To scroll through the readings rapidly press and hold Memo If no button is pressed for one minute the 2216 will return to clock mode Clock Mode 1 The 2216 will enter clock mode when the thermometer is on and no key is pressed for more than one minute 2 The time will be displayed in Year Month Date Day Hour and Minute with a flashing for seconds 3 Press Talk to speak current time aloud 4 Press and hold Memo for 2 seconds to enter setup mode and change the Date and Time Press Talk to switch between the hour minute year month and day
2. LUMISCOPE the Doctor s Choice Model 2216 Talking Digital Ear Thermometer Instruction Manual 2216 INS LAB RevA09 Congratulations on purchasing the Lumiscope Model 2216 Talking Digital Ear Thermometer Please be sure to read this manual carefully before using this new state of the art device Keep this manual handy for reference Parts Identification Take Reading Memo Button Talk Button About Taking Temperature From The Ear What is Ear Temperature Body temperature means interior or core temperature which is controlled by a lower thalamus subordinate to a hypophysis The eardrum and 2 lower thalamus have a common blood vessel Because of this shared vessel ear temperature can accurately tell fluctuation of body temperature How to Use The Ear Thermometer Properly For children younger than one year gently pull the ear in an inclined backward direction to straighten the auditory canal before inserting the temperature probe for measurement What is a Normal Ear Temperature Users body temperatures vary by age time and ambient temperature Clinical studies have shown few exceptions to the rule that the ear shows a higher temperature than the armpit axillary method For accurate fever identification it is recommended to have an understanding or baseline of patients temperatures in normal situations Preparation 1 For the most accurate measurements leave the thermomet
3. Talking Digital Ear Thermometer please contact the Lumiscope Repair Department at 1 800 672 8293 There is a 15 fee for return shipping and handling Please make checks payable to GF Health Products Inc Upon receipt we will repair or replace as appropriate the Talking Digital Ear Thermometer and return it to you Warranty is solely through the Lumiscope Repair Department Service of this product by anyone other than the Repair Department voids warranty Distributed By GF Health Products Inc Atlanta GA 30360 www grahamfield com Repair Department 1 800 672 8293 Made and Printed in China 11
4. er in the room in which it will be used for 30 minutes prior to use to acclimate the thermometer to ambient temperature Always use a clean new probe cover Only take readings from a clean ear Only take measurements during periods of rest A recent bath or exercise is likely to increase body temperature Taking Measurements 1 Thoroughly clean ear and apply a clean new probe cover to thermometer 2 Insert the temperature probe along the ear canal as deep as is comfortable into the ear press the button once to start the measurement and you will hear a single beep In about a second the temperature reading OCT EN Memory No Figure 1 will be complete and you will hear a short melody The 2216 will then speak the temperature reading aloud and display it on the large digital display Fig 1 Note If using the 2216 for the first time it is recommended that 3 consecutive measurements are taken from the same ear The maximum ofthe three readings will be recorded to memory as the readings will not likely be exactly the same This will help you get a feeling of how to use the thermometer 3 The reading will be stored into memory automatically If 30 sets of memory are stored already the first reading will be overwritten as will each existing memory with the new reading as they are taken 4 For the most accurate temperature readings wait 10 minutes between consecutive uses 5 If a measurement falls
5. r IR Sensor Measuring Range 89 6 109 37 32 0 C 42 9 C Measuring Accuracy 0 4 F 0 2 C from 96 7 F to 102 2 F 36 0 C to 39 0 C 0 5 F 0 3 C from 89 6 F to 96 6 F 32 0 C to 35 9 C 0 5 F 0 3 C from 102 3 F to 109 37 39 1 C to 42 9 C Dimensions 35 x 2 5 2 25 LxWxH 90mm x 65mm x 55mm Weight 18 lb 82g Operating 50 0 104 0 F 10 0 C 40 0 C Environment 30 80 RH Storage Environment 4 F 104 0 F 20 C 40 C 30 80 RH Accessories 10 probe covers Instruction Manual Notes 10 Warranty GF Health Products Inc guarantees this product free from defects in material and workmanship for a period of two years from the date of purchase except as noted below This product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized accessory alteration to the product or any other conditions whatsoever that are beyond the control of GF Health Products Inc GF Health Products Inc shall not be responsible for any type of incidental consequential or special damage All implied warranties including but not limited to those implied warranties of fitness and merchantability are limited to the total duration of two years from the original date of purchase To obtain warranty service on your Lumiscope Model 2216
6. settings Press Memo to advance numbers System will automatically resume clock mode if no buttons are pressed for one minute Replacing The Battery Tool needed small screwdriver Remove screw on underside of unit and remove battery cover Insert two new AAA batteries as shown in figure 2 Replace battery cover and reinstall screw Reset Button Hole C F Button Hole Troubleshooting Symptom Checklist Solution No response Is battery dead Change battery Is battery in place Check orientation of properly battery Battery symbol Low battery Change battery on screen Lo on screen Has the ther Follow instruction temperature is mometer been manual for correct below 89 6 F or positioned positioning 32 0 C correctly for a reading Hi on screen temperature is above 109 3 F Is probe cover new Change probe cover or 42 9 C ErrE on Thermometer is Allow thermometer screen outside of oper to acclimate to room ating tempera temperature ture range Erru Doesn t measure Follow instruction after pressing manual for correct measure button operating procedure ErrH Errors detected Contact Repair during self check Department at 1 800 672 8293 Specifications Model Number 2216 Power Supply DC3V AAA x 2 Power Consumption lt 0 05W for Talk Function Temperature Senso
Download Pdf Manuals
Related Search
Related Contents
DT-500GC Glass Crusher User-/service manual VIVA CMS Manual - National Centre for the Protection of Older CL 400 Benutzerhandbuch ClickReader v4 SLC Servo Module - Rockwell Automation Manual - Ventisol - Aires - Lumiar - Fênix Ref. 4801 Ref. 4802 Ref. 4804 Ref. 4881* Ref. 4808 Ref. 4809 Ref Service Manual A05-075 Copyright © All rights reserved.