Home
Linear 212LS-C26DCR-LT User's Manual
Contents
1. 9 9 H 2 Enter Master Code XXXXXX 3 Press Green LED flashes 4 Enter User Number 3 120 5 Press 4 6 Press Green LED stops flashing Enable any Key Access 1 Press 9 9 E 2 Enter Master Code H H 4 H H 2 3 Press any key to activate lock Disable any Key Access 1 Press 9 9 H 2 Enter Master Code x Hagu AeA 3 Code Required to Activate Lock Specifications e Programs the SAME as all DoorGard 1 Q OR GARD IEI Keypads e Temperature Rating 30 to 70C 22 to 158F e Battery Life up to 15 000 uses or UP to FIVE years e Powered by 4 AA Alkaline Batteries Batteries NOT included e Grade 2 Lockset ANSI 151 8 Medium e Commercially Rated e Interchangeable United States Standard Core e Left and Right Handle Models Available Colors e 26D Stainless Steel and US3 Polished Brass Finishes 212LS Electronic Access Control Cylindrical Lockset Installation amp Programming Guide DOOR GARD Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twenty four 24 months This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealer s warranty if any There are no obligations or liabilities on the part of Linear LLC for consequent
2. Features Simple to Install The DoorGard 212LS Lockset installs in 15 minutes and programs the same as all DoorGard IEl keypads It includes all mounting hardware and easily retrofits into any standard cylindrical door prep ANSI BHMA A 156 2 2003 The 212LS has a replaceable core for the manual key override The sleek design fits with any d cor and is available in 26D Stainless and US3 Polished Brass right or left handed crescent door handles Right Hand 212LS C26DCR Rt F G DoorGard Grade 2 Lockset Cylindrical Stainless Crescent handle Right handed 212LS CUS3CR Rt F G DoorGard Grade 2 Lockset Cylindrical Stainless Crescent handle Right handed Left Hand 212LS C26DCR Lt F G DoorGard Grade 2 Lockset Cylindrical Stainless Crescent handle Left handed 212LS CUS3CR Lt F G DoorGard Grade 2 Lockset Cylindrical Stainless Crescent handle Left handed Easy to Maintain Change the battery in three minutes The 212LS Lockset uses four 4 1 5V AA batteries for up to 15 000 uses or up to five years An alarm activates Low Battery Alert allowing for 30 more uses User Codes The 212LS lock recognizes up to 120 users with a different code for each and the lockset retains codes without batteries Codes can be one to six digits in length and digits can be repeated The Master Code is always stored in user location one 1 A reset button is provided inside the lock which restores factory defaults and remov
3. es codes already stored The lockset is equipped with an override mechanical key The code toggles to allow passage for an event so any key will open the lock Security and Protection The 212LS Lockset is designed with a safeguard against forced entry since the outside lever is not mechanically connected to the latch until the lock activates Also after three invalid code attempts there is a 20 second lockout period for the keypad Rugged Design The 212LS is designed for both commercial and industrial use Lockset Parts List 1 Spanner wrench 2 T Strike Door Latch 2 3 8 Backset 3 T Strike Door Latch 2 3 4 Backset Strike Plate Strike Plate Cover Latch Strikeplate Screws Allen Wrench Exterior Door Handle keypad 9 Exterior Gasket 10 Interior Gasket ONDA 11 12 13 14 Interior Faceplate Door Handle w battery case Interior Faceplate Override Keys 2 Pin Wrench pries open key slot cover Key Slot Cover Screws 2 sets Lock Assembly screws thick thin doors Sealing Washer Faceplate Assembly Nut Figure 1 Parts Diagram Installation Steps Door amp Frame Prep e Remove existing Lock from door e If itis new door with no holes use template provided e Measure backset Installation 1 Unpack the lockset and inventory all parts Remove mount ing screws separate lock assembly and both interior exterior handle plates and the two rubber gaskets 2 Insert the
4. ial damages arising out ny EI z of or in connection with use or performance of this product or other indirect gt EE bi near Building On Innovation damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation All implied warranties including implied warranties for merchantability and implied warranties for fitness are valid only until the warranty n e a r expires This Linear LLC Warranty is in lieu of all other warranties express ka or implied All products returned for warranty service require a Return Product A ne l USA amp Canada 800 421 1587 amp 800 392 0123 Authorization Number RPA Contact Linear Technical Services at 1 800 421 760 438 7000 Toll Free FAX 800 468 1340 1587 for an RPA and other important details www linearcorp com P1345
5. strike plate hole cover 5 and attach strike plate 4 in the door jam frame securing with two Phillips head SCrews 3 Install T Strike Door Latch 2 or 3 into doorjam frame and secure with two Phillips head screws 4 Assemble locks inserting two Rubber Gaskets 8 9 10 11 5 Thread battery wires through hole in Interior Faceplate Door Handle 11 6 Attach Interior Faceplate Door Handle 11 to Exterior Door Handle 8 securing with two short or long assembly screws 16 7 Insert batteries and connect battery clip 8 Secure Interior Faceplate 12 with clear plastic washer with Nut 17 18 9 Use spanner wrench 1 to tighten nut 15 10 Program the system as described in this manual 11 Instruct the users on lockset operation e Use Pin Wrench 14 to pull off cover 15 e Use override key 13 e Turn left twice P1345 Programming Steps Default Master Code 1234 Maximum Number of Users per Lockset is 120 Change Master Code Press 9 9 H Enter Master Code 1234 Press Green LED flashes Press 1 Enter NEW Master Code XXXXXX 1 to six digits Press Enter New Master Code again Press Green LED stops flashing ONAHAWN Add Users 1 Press 9 9 H 2 Enter Master Code XXXXXX 3 Press Green LED flashes 4 Enter User Number 3 120 5 Press 6 Enter User Code 1 to 6 digits 7 Press Green LED stops flashing 8 Enter User Code again 9 Press 1 Press
Download Pdf Manuals
Related Search
Related Contents
HP EZ-KIT User's Manual Edge® Juice with Attitude CTS2 Programmer Manual Copyright © All rights reserved.
Failed to retrieve file