1. tures and 10 f c between fixtures WASHER WALLWASHER WALLWASHER N UNITS 2 FEET FROM WALL 22 30 38 32 24 22 20 20 18 UNITS 3 FEET f lt i FROM WALL ul 5 8 3 4 6 4 4 2 1 1 DISTANCE FROM CEILING FT DISTANCE FROM CEILING FT 8 6 5 5 Footcandle values are averaged and rounded off and are based on a minimum of five units Conversion factors 150W A21 units with gold cone FC x 0 90 100W units clear cone FC x 0 60 gold cone FC x 0 55 Clear cone 100W A19 Coefficients of Utilization effective ceiling cavity reflectance Candlepow er Distribution FNE SPINI MTT 50 30 CEILING REFLECTANCE 50 30 10 50 10 30 76 75 73 a 42 A 70 69 72 69 68 69 68 67 67 67 67 65 63 66 64 62 65 63 65 61 58 63 60 58 61 59 60 56 54 59 56 54 58 55 56 53 50 55 52 50 54 52 52 49 47 52 48 47 51 48 50 47 4 49 46 44 48 AG AT 43 40 46 43 40 AB 42 10 44 40 37 43 40 37 43 39 Conversion Factors 20 FLOOR CAVITY REFLECTANCE 100W A 19 Clear C U X 1 0 100W and 150W A21 Gold C U X 0 9 1 22 3 4 gt S 5 6 27 8 w MIT S EA g For even wall washing use a maximum DOWNLIGHT SPACING RATIO 1 3 of 2 to 1 spacing distance between Job Information Type fixture distance to wall WIOLRFSOM Lightolier a Genlyte Thom
2. Reflector provides even wall wash Must be installed before ceiling is finished Other Reflector Finish Options Consult Factory 1951 Set of 2 1956 Set of 4 for 1950 amp 1951 bars 7994 Set of 2 7998 Set of 2 7997 See separate specification sheet LC add suffix to Frame in Kit 27 Mounting Bars T Bar Anchor clips Wood J oist Mounting Bars Existing Ceiling clips Step Down Transformer Chicago Air Plenum Electrical UL Listed for a maximum of 8 No 12 75 C through branch circuit conductors or C supply conductors for end of run 6 Labels UL Listed for damp locations B E W Alzak is a registered trademark of ALCOA Job Information Job Name Cat No Lamp s Notes Lightolier a Genlyte Thomas Company www lightolier com 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2002 Genlyte Thomas Group LLC Lightolier Division e A0902 WIOLRFSOM l Calculite Incandescent Open Wall Washer R7029 Page 2 of 2 6 Aperture A19 A21 3 DOUBLE EXAMPLE With multiple clear cone units using 150W A21 lamps located 3 from wall and 6 on cen ter matching downlights N P M E J4 7054 downlights 6 on cen YN ter the illumination on the N wall 3 down from the ceil N WALL INSIDE CORNER ing is 14 f c beneath fix
3. ae Page 1 of 2 Calculite Incandescent Open Wall Washer R7029 6 Aperture A19 A21 Top View yA 9 5 16 JH 10 1 4 gt Rat 13 1 4 Flush Trim Molded Overlap Self Flange Molded Trim Trim Ring Matte White Ring Removed or Polished Ceiling Runner Ceiling Cutout 6 9 16 Dia max J iling hickness Reflector Trims Frame In Kits Lamp White Polished Flush White Finish Self Flange Self Flange Molded Trim Ring Wall Washer Specular Clear R7029CLW R7029CLP R7029CL R601 Clear A19 100W Specular Gold 7029GDW 7029GDP 7029GD 602 Gold A21 150W Corner Wall Washer Specular Clear R7030CLW R7030CLP R7030CL R601 Clear A19 100W Specular Gold S7030GDW S7030GDP S7030GD S602 Gold A21 150W Double Wall Washer Specular Clear R7031CLW R7031CLP R7031CL R601 Clear A19 100W Specular Gold S7031GDW S7031GDP S7031GD S602 Gold A21 150W Features Options amp Accessories 1 Socket Cup Die cast aluminum cup effectively dissipates heat and assures 18 Mounting Bars 1950 Set of 2 lamps maintain proper optical alignment to reflector Snaps onto reflector neck for easy tool less installation Can be adjusted without tools from inside or outside of fixture to accommodate two different lamp sizes Contains medium base porcelain socket with nickel plated screw shell wired with No 18 SF1 leads to J Box 2 Mounti
4. as Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2002 Genlyte Thomas Group LLC Lightolier Division e A0902 el
5. ng Brackets Adjust vertically from inside of fixture Durable 16 ga steel construction Use with standard 3 4 or 1 1 2 lathing channels or 1 2 11 16 0 D EMT pipe by others or Lightolier accessory mounting bars 3 Retaining Springs Precision tooled springs secure reflector housing to mounting frame for quick tool less installation 4 Insert Reflector Alzak aluminum 16 ga cut window reflector allows ight to pass to a separately contoured outer housing reflector 50 visual cut off to lamp and lamp image Insert reflector contours provide even down ighting Direction of wall wash can be re oriented after installation Attaches with screws for simple installation and maintenance Reflector sup plied with white molded trim ring field paintable or self flanged reflector matte white flange or flange finish to match reflector 5 J unction Box 14 ga steel 4 x 3 1 2 x 2 box allows inspection from below 6 Thermal Protector Meets NEC and UL requirements Insulation must be kept 3 away from fixture sides and wiring compartments and must not be laced above fixture in a manner which will entrap heat 7 Mounting Frame Die cast aluminum suitable for dry or plaster ceilings Provides flangeless trim in plaster ceiling 8 Wall Wash Reflector Housing Specular clear or gold 16 ga Alzak alu minum to match insert reflector Attaches to mounting frame with springs Detachable for inspection from below fixture