Home
Lightolier IS_PTS5-6-8 User's Manual
Contents
1. or corners in row 10 Install right hand end plate to last fixture in row using supplied hardware 3 8 screws and nuts 11 Make necessary electrical connections to fixture that provides power to row and reinstall reflector Make sure not to exceed more than 20 amps per feed 12 Install all lamps and shielding if applicable to fixtures in row Fig 3 See Detail A ca Figure 3 Detail A 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B1108 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Lighting Systems IS_PTS5 6 8 Page 4 of 6 Instruction Sheet for Assembly and Installation of Perimeter Trough System 5 6 amp 8 ADJUSTABLE FIXTURE 1 Note Adjustable fixtures are shipped extended to maximum length They will retract down 11 on the non staggered versions and 9 on the staggered versions 2 To determine which adjustable fixture will fit in the ceiling opening measure from last non adjustable fixture to wall or last non adjustable fixture to corner fixture 3A For Fixture Using non Staggered Lamps Use the 4 adjustable fixtures in opening from 48 75 60 Use the 3 adjustable fixtures in opening from 36 75 48 Use the 2 adjustable fixtures in opening from 24 75 36 3B For Fixture Using Staggered Lamps Use
2. the 4 staggered fixtures in opening from 51 60 Use the 3 staggered fixtures in opening from 39 48 Use the 2 staggered fixtures in opening from 27 36 4 To adjust fixture to proper length remove the number 8 screws on T Trim and Hang Bracket that keep Sliding Sleeve from moving Fig 4 5 Push on Sliding Sleeve to proper length Fig 5 T Trim Hang Bracket and reflector will not move Figure 4 Figure 5 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B1108 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Lighting Systems IS_PTS5 6 8 Page 5 of 6 Instruction Sheet for Assembly and Installation of Perimeter Trough System 5 6 amp 8 ADJUSTABLE FIXTURE CONT D 6 Next push on Adjustable Reflector until flush with end of Sliding Sleeve Fig 6 7 Remove and cut T Trim and Hanging Bracket to proper length Fig 7 8 Install right hand end plate to Adjustable fixture in row using supplied hardware 3 8 screws and nuts Re attach T Trim and Hanging Bracket to Sliding Sleeve using number 8 screws Fig 7 Hang Bracket j oars Screws New Location Figure 6 Figure 7 9 Lift Adjustable fixture into position and hook to J Rail Hang from Suspension Wire 10 Join electrical Quick Connectors together and make sure fixture is properly level
3. 11 Secure fixtures together using supplied hardware 3 8 screws and nuts 12 Install all lamps and shielding if applicable to fixtures in row Fig 3 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B1108 Lightolier is a Philips group brand PHILIPS LICH TOLIER Lighting Systems IS _PTS5 6 8 Page 6 of 6 Instruction Sheet for Assembly and Installation of Perimeter Trough System 5 6 amp 8 LAMPING PROCEDURE 1 Remove the louver or lens if applicable Fig 8 Figure 8 2 Reach into the fixture and pull the top of the lamp shield downward and towards the wall Fig 9 cae Shield Figure 9 3 Rotate and remove the lamp Fig 10 4 Replace with new lamp Fig 11 SN Lamp Figure 10 Figure 11 5 Push the lamp shield up and away from the wall until it snaps into place Fig 12 Figure 13 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B1108 Lightolier is a Philips group brand PHILIPS
4. LIGHTOLIEI Lighting Systems IS_PTS5 6 8 Page 1 of 6 Instruction Sheet for Assembly and Installation of Perimeter Trough System 5 6 amp 8 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE PROCEEDING RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE This fixture is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at electrical panel before proceeding DO NOT INSTALL THIS SYSTEM IN A WET OR DAMP LOCATION DO NOT ENERGIZE ANYTHING OTHER THAN THE FIXTURES IN THE SYSTEM CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY REINFORCING WALL AND CEILING TO SUPPORT FIXTURE WEIGHT ol ON TN PTS 5 One Ligt 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B1108 Lightolier is a Philips group brand PHILIPS LICHTOLIER Lighting Systems IS _PTS5 6 8 Page 2 of 6 Instruction Sheet for Assembly and Installation of Perimeter Trough System 5 6 amp 8 INSTALL FIXTURE HOUSING 1 Install J Rail s to wall using adequate hardware by others 3 1 2 above the room ceiling line Properly level along the length of the row Fig 1 2 Determine which fixtu
5. re will provide power to row and remove a 7 8 KO from top of housing Also remove the reflector from fixture Note install fixtures from left to right as installer faces the wall Wall 10 Minimum j Wall to T Trim e Wei 3 1 2 from Screw to Bottom of T Trim a 6 1 8 Opening from Wall to Tile Figure 1 3 Hang Suspension Wire from structure above spaced according to fixture lengths 4 Install left hand end plate to first fixture in row using supplied hardware 3 8 screws and nuts 5 Lift first fixture into position and hook to J Rail also hang from Suspension Wire Making sure it is properly leveled Fig 2 Fig 2 Suspension Wire EN Figure 2 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B1108 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Lighting Systems IS_PTS5 6 8 Page 3 of 6 Instruction Sheet for Assembly and Installation of Perimeter Trough System 5 6 amp 8 INSTALL FIXTURE HOUSING CONT D 6 Lift second fixture into position and hook to J Rail also hang from Suspension Wire 7 Snap electrical Quick Connectors together and make sure fixture is properly level 8 Secure fixtures together using supplied hardware 3 8 screws and nuts 9 Repeat these steps for following fixtures and
Download Pdf Manuals
Related Search
Related Contents
Pêra Rocha do Oeste - RUN - Universidade Nova de Lisboa KR7A-133/KR7A-133R German User's Manual Rev. 1.01 for WEB Lenco DPA-24 DIGITAL PHOTO ALBUM Agilent 1200 Series Fluorescence Detector Avaya DBM32 User's Manual Copyright © All rights reserved.
Failed to retrieve file