1. LIGHTOLIER Lighting Systems IS EG2 Page 1 of 4 Instruction Sheet for Assembly and Installation of Energos EG2 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE PROCEEDING RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE This fixture is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at electrical panel before proceeding DO NOT INSTALL THIS SYSTEM IN A WET OR DAMP LOCATION DO NOT ENERGIZE ANYTHING OTHER THAN THE FIXTURES IN THE SYSTEM DO NOT OVERLOAD FEED CABLE 10 AMP MAX FOR SJT 18 3 AND 7 AMP MAX FOR SJT 18 4 amp 18 5 THE FIXTURES IN THIS SYSTEM HAVE A POLARIZED MALE AND FEMALE PLUG AT EACH END THESE PLUGS WILL SNAP TOGETHER SIMPLY BY PUSHING FIXTURES TOGETHER CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY REINFORCING CEILING TO SUPPORT FIXTURE WEIGHT OO 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Lighting Systems IS EG2 Page 2 of 4 Instruction Sheet for Assembly and Installation of Energos EG2 P 48 or 96 48 or 96 lt d Junction Box l
2. and pushing or pulling on cables as required then cut excess cable If necessary level fixture widthwise by loosening the small screw at bottom of cable gripper and adjust sideways Be sure to re tighten the screw Do not over tighten Step3 Installing the Remaining Fixtures moommr F Orient the next fixture s female plug so it faces the previous fixture s male plug Insert the Hanging Clips from second and third suspension assemblies into the second fixture Push fixtures together Tighten each of the 1 4 20 bolts in both fixtures Level fixture lengthwise by pressing down on top of cable grippers and pushing or pulling on cables as required then cut excess cable If necessary level fixture widthwise by loosening the small screw at bottom of cable gripper and adjust sideways Be sure to re tighten set screw Do not over tighten Repeat step 3 as many times as required to complete row Step 4 End of Row A B C Lightolier is a Philips group brand Remove the cover from non Power End Cap by removing two no 8 screws Hold the End Cap flush with the last fixture in row Tighten the 1 4 20 bolts replace cover 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lighting Systems IS EG2 Instruction Sheet for Assembly and Installation of Energos EG2 PHILIPS LIGHTOLIER Li
3. ghting Systems IS EG2 Page 4 of 4 Instruction Sheet for Assembly and Installation of Energos EG2 Depending on voltage lamps and row length the need for additional Power Drops may arise A minor modification must be made to the fixture receiving the Power Drop Step 1 Modifying the Unit Remove reflector to gain access to Line Voltage splice compartment Remove 1 2 dia k o from reflector Cut the appropriate wires from wire harness and cap wires going to previous fixture See note below Tap appropriate wires from power cord into modified fixture s wire harness Route cord through hole in socket bracket then through reflector hole and finally through canopy Make all necessary connections at the ceiling j box Continue attaching fixtures until a new Power Drop unit is required QnmMooODD NOTE In some instances some of the wires in the fixture are required to remain uncut DALI SHARING DAYLIGHT SENSOR ETC In this case only cut and tap into the hot and neutral wires in the wire harness Power Cord 1st Power Drop Figure 3 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS
4. l n By Others amp Negi a Cahbby Canopy Canopy AN Figure 1 Power Cord 8 Screws E a Cover Male Plug 1 4 20 Bolt Cable Gripper Power Cord Female Plug 1 4 20 Bolt 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Page 3 of 4 Step 1 Installing the Suspension Cables A B C D Install the power cable suspension assembly to the junction box Fig 1 Make sure to secure the green ground wire from Power Cord to the cross bar The first suspension in each row should be from the power feed end which contains a male power cord and an end cap Fig 1 Install the remaining cable suspension assemblies to the ceiling structure spaced at 48 or 96 apart as required Step2 Installing the First Fixture A B C D Hold the end cap flush with the end of the first fixture Tighten the 1 4 20 bolt from fixture and 1 4 20 bolt from E Remove the cover from Power End Cap by removing two no 8 screws Orient fixture so female plug in fixture faces the Power cord male plug Insert the Hanging Clips from first and second cable suspension assemblies into the fixture Fig 2 Power End Cap Fig 2 Replace cover Level fixture lengthwise by pressing down on top of cable grippers

Download Pdf Manuals

image

Related Search

Related Contents

Internetbasiertes System zur energetischen Optimierung der  Owner`s Manual CY-5 - Music Media Centar  LEC-SD01N10シリーズ取扱説明書 [PDF形式]    Lire le communiqué de presse  Acer TravelMate P2 253-MG-32344G50Mak  Instruction Manual  gefen ext-hdmi1-3-2-3gsdi product manual  Elite EIM-506 Use and Care Manual  NOTICE OF TEMPORARY APPROVAL  

Copyright © All rights reserved.
Failed to retrieve file