Home
Lightolier IS-EG1 User's Manual
Contents
1. Level fixture lengthwise by pressing down on top of cable grippers and pushing or pulling on cables as required then cut excess cable If necessary level fixture widthwise by loosening the small screw at bottom of cable gripper and adjust sideways Be sure to re tighten screw Do not over tighten Step3 Installing the Remaining Fixtures moommr F Orient the next fixture s female plug in fixture so it faces the previous fixture s male plug Insert the Hanging Clips from second and third suspension assemblies into the second fixture Push fixtures together Tighten each of the 1 4 20 bolt in both fixtures Level fixture lengthwise by pressing down on top of cable grippers and pushing or pulling on cables as required then cut excess cable If necessary level fixture widthwise by loosening the small screw at bottom of cable gripper and adjust sideways Be sure to re tighten screw Do not over tighten Repeat Step 3 as many times as required to complete row Step 4 End of Row A B Hold the end cap flush with the last fixture in row Tighten the 1 4 20 bolts and 10 32 screw 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Lighting Systems IS EG1 Page 4 of 4 Instruction Sheet for Assembly and Installation of Energos EG
2. 1 Depending on voltage lamps and row length the need for additional Power Drops may arise A minor modification must be made to the fixture receiving the Power Drop Step 1 Modifying the Unit Remove reflector to gain access to Line Voltage splice compartment Remove 1 2 dia k o from reflector Cut the appropriate wires from wire harness and cap wires going to previous fixture See note below Tap appropriate wires from power cord into modified fixture s wire harness Route cord through hole in socket bracket then through reflector hole and finally through canopy Make all necessary connections at the ceiling j box Continue attaching fixtures until a new Power Drop unit is required Q5 rm C 625 P NOTE In some instances some of the wires in the fixture are required to remain uncut DALI SHARING DAYLIGHT SENSOR ETC In this case only cut and tap into the hot and neutral wires in the wire harness 1st Power Drop E Power Cord 96 ae Figure 3 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS
3. LIGHTOLIER Lighting Systems IS EG1 Page 1 of 4 Instruction Sheet for Assembly and Installation of Energos EG1 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE PROCEEDING RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE This fixture is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at electrical panel before proceeding DO NOT INSTALL THIS SYSTEM IN A WET OR DAMP LOCATION DO NOT ENERGIZE ANYTHING OTHER THAN THE FIXTURES IN THE SYSTEM DO NOT OVERLOAD FEED CABLE 10 AMP MAX FOR SJT 18 3 AND 7 AMP MAX FOR SJT 18 4 amp 18 5 THE FIXTURES IN THIS SYSTEM HAVE A POLARIZED MALE AND FEMALE PLUG AT EACH END THESE PLUGS WILL SNAP TOGETHER SIMPLY BY PUSHING FIXTURES TOGETHER CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY REINFORCING CEILING TO SUPPORT FIXTURE WEIGHT 2121 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Lighting Systems IS EG1 Page 2 of 4 Instruction Sheet for Assembly and Installation of Energos EG1 P 48 or 96 48 or 96 rs p a Junction Box l 4 By O
4. thers 4 TD a ER amp Nusa Cahbby Canopy Canopy DS Figure 1 Power Cord Male Plug Cable 4 Female Plug 10 32 Screw Cable Gripper Screw Do Not Over Tighten Figure 2 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group e B0608 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Lighting Systems IS EG1 Page 3 of 4 Instruction Sheet for Assembly and Installation of Energos EG1 Step 1 Installing the Suspension Cables A B C D Install the power cable suspension assembly to the junction box Fig 1 Make sure to secure the green ground wire from Power Cord to the cross bar The first suspension in each row should be from the power feed end which contains a male power cord and an end cap Fig 1 Install the remaining cable suspension assemblies to the ceiling structure spaced at 48 or 96 apart as required Step2 Installing the First Fixture mmoou zr Orient fixture so female plug in fixture faces the Power cord male plug Insert the Hanging Clips from first and second cable suspension assemblies into the fixture Fig 2 Connect the Power male cord plug into the first fixture female plug Hold the end cap flush with the end of the first fixture Tighten the 1 4 20 bolt and the 13 32 screw Fig 2
Download Pdf Manuals
Related Search
Related Contents
User manual DT-TS WiFi Leica CM1850 UV Descargar Copyright © All rights reserved.
Failed to retrieve file