1. gt INSTRUCTION SHEET NO INSTRUCTIONS PROCEDURE FOR LOW VOLTAGE l S m 2 0 0 0 LV NT FRAME IN KIT WITH REMOTE TRANSFORMER lt 0191 Page 1 of 2 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE This fixture is intended for installation in accordance with the National Electrical Code or local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at fuse box before proceeding Retain these instructions for maintenance reference NOTE FRAME4N KIT IS PROVIDED WITHOUT TRANSFORMER TRANSFORMER MUST BE PROVIDED BY OTHERS LIGHTOLIER CAT 8608 AND 8609 TRANSFORMERS MAY BE USED CAUTION THIS FRAME IN KIT IS RATED AT 42VA USE ONLY 12V A C INPUT FIG C FIG D 1 FRAME IN 2 CLOSE IN 3 SNAP ON 4 PUSH UP WARNING RISK OF FIRE DO NOT INSTALL INSULATION WITHIN 3 INCHES OF FIXTURE SIDES OR WIRING COMPARTMENT NOR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HEAT 1 FRAME IN Fig A Fasten MOUNTING FRAME to wood joist Line up bottom edge of ADJUSTABLE MOUNTING BAR with bottom of wood joist Fig E Wire fixture leads to secondary 12v transformer leads Connect bare fixture wire to supply ground Use wire nuts local hardware items Place all electrical connections in the J box Attach J box cover on to J box For cable use built in cable clamp in J box 4 LIN
2. E UP BOTTOM EDGE ia Le NOTE ADJUSTABLE MOUNTING BARS can be MARAME S E WITH BOTTOM OF WOOD extended for 24 mounting For suspended NAILING TAG celling make certain that the bottom of i 1 Position NAILING TABS of ADJUSTABLE MOUNTING FRAME is no higher than above je N NA LNG TARS of ADJUSTABLE nsr ceiling line Fig F spacing to finished ceiling T BAR ANCHOR CLIPS ACCESSORY NO 1956 order separately can be used tor quick mounting ADJUSTABLE MOUNTING BAR FIG E 2 CLOSE IN Fig B Install plasterboard or other dry type ceiling as required Hole in board must be cut either on the ground or after the board is nailed to the ceiling using MOUNTING FRAME opening as a cutting guide Make sure ROTO CLIPS are rotated out of hole area to be cut NOTE For wet plaster ceiling use Plaster Ring Accessory No 1959 order separately IN Fig C SEE SEPARATE a aaa ee REFLECTOR TRIM 4 PUSH UP Fig D INSTRUCTION SHEETS SEE BACK PAGE FOR LAMPING INSTRUCTIONS LICsE ITOLIE I SECAUCUS NEW JERSEY 07096 MONTREAL QUEBEC CANADA LAMPING NOTE Socket manufacturers have suggested that socket may fail after 3 to 6 relampings If this occurs socket can be replaced by disconnecting male connectors attached to socket leads from female connectors attached to fixture leads and replacing it with a new socket procured through Lightolier Fig
3. H 1 Make sure that power is OFF when lamping or relamping Remove LAMP RING from SOCKET CUP by pulling straight down 2 Insert LAMP MR 16 between LAMP SPRINGS until face of lamp sits firmly on GLASS LAMP GUARD Fig 3 Attach SOCKET to bi pin prongs on LAMP 4 Insert LAMP RING with LAMP and GLASS LAMP GUARD back into SOCKET CUP WARNING 1 LAMP MANUFACTURERS REQUIRE THE GLASS LAMP GUARD BE IN PLACE BEFORE ENERGIZING LAMP AND THAT GREAT CARE MUST BE TAKEN THAT LAMP IS FULLY COOLED BEFORE RELAMPING AVOID FINGER MARKS ON INSIDE OF Asan FAD TLEY BAA PALIOR GUAT ALAN l IEI ANI rVvn Ie MAL VAVUOE OIVN LAM LIFE AND POSSIBLE BREAKAGE 2 USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER INC USE OF OTHER MANUFAC TURER S REFLECTOR TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD AIMING ANGLE ADJUSTMENT Fig J 1 For vertical adjustment insert blade of snrawarivar intan tha anan alat nf VOWE VVIVYVMEEPYOL Ll lit VCH eR VI TWING 2 Using the screwdriver as a lever tilt the entire LAMP HOLDER to the desired angle 3 For horizontal adjustment rotate the LAMP HOLDER NOTE 1 LOW VOLTAGE FIXTURES should be dimmed only with special dimmers intended specifically for that purpose Use Lightolier Lytemode Scenist Crescendo VA Neptune VA Precision VA Easyset VA Sunrise VA Radiant VA or equivalent products by others or variable autotransformers or elect
4. ronic dimmers intended for use with low voltage fixtures 2 Low voltage fixtures may produce audible sound when used with dimmers which may be objectional In acoustically critical areas NOTE Follow the max wire length recommended below to minimize voltage drop Voltage drop will affart tha hrinhtnace and anian af the Hehe mtiwwe BEE COS ERC REE QNM WIE wi tG Hylite WIRE GA WIRE LENGTH FT INSULATING SLEEVING 1S 2000LVNT 0191 Page 2 of 2 MALE CONNECTORS Attached to Socket Wires AIA esetenseenens RELLA FEMALE CONNECTORS Attached to Fixture Wires MR16 SOCKET FIG H SOCKET LAMP LAMP SPRING GLASS LAMP GLASS LAMP RING FIG LAMP HOLDER APERTURE TRIM ASSEMBLY

Download Pdf Manuals

image

Related Search

Related Contents

ATELIERS FORMATIONS & AUTRES RENCONTRES  Sweex Graphics Tablet USB  Sunny Boy 2500 Inversor String para sistemas fotovoltaicos  PDF file created from a TIFF document. - Support  User Manual  Manual - Black & Decker  第27期 平成22年3月31日 PDF 形式 417 KB  Samsung LS22A13W دليل المستخدم  

Copyright © All rights reserved.
Failed to retrieve file