Home
Lightolier EC2-5 User's Manual
Contents
1. 243 84cm Master Module 8 243 84cm Slave Module Single Set EG2EC36W End Set EC2ER36W Sensor End Set and Intermediate Cable Assembly 16 Run 8 243 84cm Master Module 8 243 84cm Slave Module Single Sensor End Set and Intermediate Cable Assembly Notes 1 See page 1 of Specification Sheet or consult Application Guide for the definition of Serial Row Linking SRL 2 Consult the matching EG specification sheet for Luminaire related specifications i e Housing materials shielding mounting dimensions and photometry Job Information Type sid 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Lighting Systems EC2 5 Page 3 of 3 Energos Control System 2 Light T5 per 4 121 92cm Nominal Louver Ballast Ordering Information Lamp Ordering Information gt Rated Output Design Lamp Type Ballast Factor Start Type THD Design Lamp Type Wattage Lumens Color K F T5 1 00 Program lt 10 M T5 28 2600 3000 G T5HO 1 00 Program lt 10 N T5 28 2600 3500 Dim T5 1 00 01 Program lt 10 0 T5 28 2600 4100 J Dim T5HO 1 00 03 Program lt 10 P T5 54 4450 3000 Q T5 54 4450 3500 R T5 54 4450 4100 25 C Rating Lamp and Ballast System Data E Lamp Type Balla
2. 120 Vac Slave 6 6 through wires slotted to 9 277 Vac Slave D Dual Switch reflector T Tandem Switch E Emergency Ordering Instructions Continuous Row Mounted ECS Systems 1 Determine run length End Cap ECS Systems 2 Order a minimum of one master per run Please see Application Guide for 1 Order Master 4 121 92cm or 8 243 84cm ECS Module master requirements on runs that exceed 16 487 68cm 2 Order Power Feed End Set 3 Order the required remaining Master and Slave modules to complete the run 4 Order Power Feed End Set 5 Order one CABLE ASSEMBLY per MODULE minus one per run 6 Order additional Single Cable amp Cord Sets for every Master Module in run ECS Sensor Sample Runs ECS End Sets 4 Run 4 121 92cm Master Module with Single Sensor End Set 2 Single Sensor Dual Sensor Single Cable amp 8 Run 8 243 84cm Master Module and standard Energos End Set End Set EC2SE36W End Set EC2DE36W Power Cord EGCC36 8 Run 8 243 84cm Master Module and Dual Sensor End Set i E E Single Sensor SRL Dual Sensor SRL 12 Run 8 243 84cm Master Module 4 121 92cm Slave Module Dual End Set EC2SR36W End Set EC2DR36W Sensor End Set and Intermediate Cable Assembly 16 Run 8 243 84cm Master Module 8 243 84cm Slave Module standard Energos End Set and Intermediate Cable Assembly Standard End SRL Standard 16 Run 8
3. Power Pack There is no limitation to the number of Power Packs that can be daisy chained to a s ingle ECS circuit ECS for emergency m of 90 minutes nction with ECS H owever the control Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off Serial Row Linking SRL provides multiple continuous row communication For every run that SRL is required order the appropriate SRL end set from page 2 of this Specification Sheet Consult Energos Application Guide for more detailed definitions and examples Mountings Cable suspension distances are on 48 121 92cm and 96 243 84cm centers and consist of a 4 1 2 11 43cm diameter canopy finished white enamel A 1 16 0 16cm diameter stainless steel aircraft cable accomplishes suspension and is adjustable from 12 30 48cm to 36 91 44cm Power feeds are 18 gauge silver braided cord with clear jacket Lightolier is a Philips group brand 0 Coverage Diameter I ccupancy Sensors Time delay is factory pre set to 30 minutes Time delay can be field adjusted from 30 minutes to a minimum of 30 seconds Daylight hold off is factory pre set to 120 ft candles 1291 67m candles Daylight hold off is field adjustable from 120 ft candles 1291 67m candles down to 10 ft candles 107 64m candles Sensors are designed for a detection area sensitivity d
4. LIGHTOLIER Page 1 of 3 Lighting Systems EC2 5 Energos Control System 2 Light T5 per 4 121 92cm Nominal Louver Feature Specifications Energos Control System For standard Energos fixtures consult appropriate EG spec sheets Feature Specifications Electrical Dedicated low voltage 24 VDC circuit controls the Energos Control Systems The line voltage circuits control all the standard ballast functions including A B switch ing Dimming and Emergency Battery Pack operations 1 End Cap Sensor Mounting 2 Mid mounted 8 243 84cm Sensor Mounting ECS occupancy sensors are available in two variations e Mounted in the end cap e The middle of an 8 243 84cm The ECS system control center is each Master Pack can control up to 600 watts module he Power Pack The Power Pack contained in 20 VAC and 130 of 10 sensors can be used on a single Emergency battery packs can be egress lighting since all listed packs operate for a minim ighting for emergency circuit for power mmended for this purpose EM Packs can be used as momen transitions and smaller packs are sed i ary reco n conjunction with Dimming ballasts can be used in conju system will only perform ON or OFF operations and will not affect the level of dim ming set by the dimming ballasts odule interrupts the circuits when parameters dictate The Power 0 watts 277 VAC A maximum
5. e the IES Ouput value shown on this table Job information tee 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS
6. iameter of 16 487 68cm when suspended 10 304 80cm AFF Lowering the sensor produces a smaller area of detection See chart and diagram for additional information Energos Occupancy Sensor Coverage Zone Chart Height of Sensor Broadcast Diameter 10 0 304 80cm 16 0 487 68cm 9 0 274 32cm 14 5 427 99cm 8 0 243 84cm 12 10 391 16cm 7 0 213 36cm 11 3 336 04cm Job Information Job Name Cat No Lamp s Notes 16 0 14 5 I 12 10 Sensor Height AFF Yo of 7 0 8 0 9 0 10 0 1 1 x i Task Diameter 8 0 243 84cm 7 3 214 12cm 6 5 184 15cm 5 7 154 18cm 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS LIGHTOLIEI Lighting Systems EG2 5 Page 2 of 3 Energos Control System 2 Light T5 per 4 121 92cm Nominal Louver Control Ordering Information Family Series Lamping amp Ballast Lamp Shielding Length Voltage Finish Options Distribution Blank EC 2 P 2 2 lamp See Chart on See Chart on P Parabolic 4 4 121 92cm 6 120 Vac Master A Aluminum 4 4 through wires open top Page 3 Page 3 Louver 8 8 243 84cm 7 277 Vac Master W White 5 5 through wires 5 2 lamp 8
7. st Ballast Lamp Rated kamp ramp IES Output system System System Start Design T8 or T5 Factor BF THD Wattage Rated Color lumens Input Efficacy Lamp Life Type Output Kelvin Watts lum watt Hours FM T5 1 lt 10 28 2600 3000 2600 31 0 83 87 20000 Program FN T5 1 lt 10 28 2600 3500 2600 31 0 83 87 20000 Program FO T5 1 lt 10 28 2600 4100 2600 31 0 83 87 20000 Program GP HO 1 lt 10 54 4450 3000 4450 58 5 76 07 20000 Program GQ HO 1 lt 10 54 4450 3500 4450 58 5 76 07 20000 Program GR HO 1 lt 10 54 4450 4100 4450 58 5 76 07 20000 Program IM T5 DIM 1 0 01 lt 10 28 2600 3000 2600 26 33 5 8 77 60 NA Program IN T5 DIM 1 0 01 lt 10 28 2600 3500 2600 26 33 5 8 77 60 NA Program 10 T5 DIM 1 0 01 lt 10 28 2600 4100 2600 26 3815748 77 60 NA Program JP T5HO DIM 1 0 03 lt 10 54 4450 3000 4450 134 63 12 5 70 60 NA Program JQ T5HO DIM 1 0 03 lt 10 54 4450 3500 4450 134 63 12 5 70 60 NA Program JR T5HO DIM 1 0 03 lt 10 54 4450 4100 4450 134 63 12 5 70 60 NA Program 25 C Rating Data is based on Osram Sylvania specifications All data is per 1 lamp on a two lamp system at 277 VAC When ordering no lamps provided by Lightolier use lamp code Z Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files Files have already been adjusted The lumen Lightolier is a Philips group brand value for the lamp within a Lighting Design program will b
Download Pdf Manuals
Related Search
Related Contents
リスクマネジメントサービス Dual WAN ADSL2+ / Broadband Firewall Router User Manual hr-xvc11b hr-xvc12s dvd player & video cassette recorder instructions Elite Screens vMax Liebert® GXT4™ UPS 230V 1000VA-3000VA Fixapart EL-CONN041S Biffi Pneumatic Actuators, Series B/C PDFファイル Grand Lyon : Rapport Tierce-Expertise études - Préconisations Copyright © All rights reserved.