1. RECTAL USE Commonly used for babies young children or when it is difficult to take an oral or underarm temperature After placing the probe cover on the thermometer lubricate with a water soluble jelly such as K Y Jelly Gently insert the probe tip no more than 1 2 inch or 1 3 cm into the rectum Do not force the tip into the rectum if resistance is encountered Wash the thermometer as recommended Approximate measurement time is 60 seconds Once used rectally the thermometer should not be used orally for sanitary reasons CLEANING INSTRUCTIONS Wash the area extending about 2 from the tip with warm soapy water after each use and dry thoroughly OR Wipe the area extending about 2 from the tip with 70 isopropyl alcohol after each use NOTE Do not submerse the thermometer in any liquid DT703 indd 5 8 CHANGING THE BATTERY When the lll appears and blinks the battery needs to be replaced Make sure you use the same type of battery and proceed as follows Remove battery compart ment lid Use a non metal probe to remove battery Insert new equivalent battery type 1 55V or LR41 Ensure battery is correctly positioned with the facing up Carefully replace the battery compartment lid Properly dispose of the battery keep ing it from small children and heat SWITCHING BETWEEN FAHRENHEIT amp CELSIUS 1 Press START button 2 Wait until L symbol appears and F C starts flashing 3
2. Press and hold START button until F C symbol flashes five times 4 Release the START button The thermometer is now changed to C F 5 The thermometer is now ready for measurement e SPECIFICATIONS RANGE ns rd 32 0 C 44 0 C 90 0 F 110 0 F ACCURACY MEASUREMENT RANGE 0 3 F less than 95 0 F 0 2 F from 95 0 F to 107 6 F 0 3 F from 107 6 F to 109 4 F 0 2 C less than 35 0 C 0 1 C from 35 0 C to 42 0 C 0 2 C from 42 0 C to 43 0 C DISPLAY oops bed at ees 0 1 F 0 1 C BATTERY usas r a sera aa One 1 55V button size battery LR41 type of equivalent POWER CONSUMPTION Less than or equal to 0 09mW BATTERY LIFE 0000 Approximately 200 hours of continuous operation DIMENSIONS oc pins 2 2 2402 svati 5 1 x 0 6 x 0 3 13 2 x 1 65 x 0 93 cm WEIGHT ccc vicki cnet eran Learn Approximately 13 grams including battery PRECAUTIONS Do not drop unit or subject to shock Do not boil the probe Clean the probe with isopropyl alcohol Do not use solvents or thinners on the unit Do not store the unit in direct sunlight or at high temperature Do not attempt to disassemble the unit except to replace the battery WARRANTY A amp D Medical warrants to the first retail purchaser that this digital thermometer is free from defects in material and workmanship for the lifetime of the original owner This warranty does not cover batteries or da
3. s de cada uso NOTA No sumerja el term metro en ning n l quido DT703_SP indd 5 8 C MO CAMBIAR LA BATER A Cuando aparezca titilando la se al de Mila ser necesario cambiar la bater a Aseg rese de utilizar el mismo tipo de bater a y proceda de la siguiente manera Quite la tapa del compartimiento de la bater a Utilice un instrumento no met lico para quitar la bater a Introduzca un nueva bater a de tipo equivalente 1 55 V o LR41 Aseg rese de que la bater a est ubicada correctamente con el signo hacia arriba Reemplace cuidadosamente la tapa del compartimiento de la bater a Deseche la bater a en forma apropiada manteni ndola alejada del alcance de los ni os peque os y no la exponga al calor CAMBIO DE FAHRENHEIT A CELSIUS Y VICEVERSA 1 Presione el bot n de ENCENDIDO 2 Espere hasta que aparezca el simbolo L y que F C comience a titilar 3 Pulse y mantenga presionado el bot n de ENCENDIDO hasta que el s mbolo F C titile cinco veces 4 El term metro habr cambiado a C F 5 El term metro est listo para la medici n ESPECIFICACIONES RANGO DE EXACTITUD DE MEDICI N CONSUMO DE ENERG A DURACI N DE LA BATER A 32 0 C 44 0 C 90 0 F 110 0 F 0 3 F menor a 95 0 F 0 2 F desde 95 0 F hasta 107 6 F 0 3 F desde 107 6 F hasta 109 4 F 0 2 C menor a 35 0 C 0 1 C desde 35 0 C hasta 42 0 C 0 2 C
4. GARANT A EXPL CITA Algunos estados pueden tener leyes que modifiquen esta garant a A amp D Medical K Y Jelly es un marca registrada de Johnson amp Johnson Una divisi n de A amp D Engineering LifeSource es una marca registrada de A amp D Medical 1555 McCandless Drive 2006 A amp D Medical Milpitas CA 95035 Fabricado en China L nea de llamada gratuita LifeSource Health 1 888 726 9966 www LifeSourceOnline com 3 3 06 10 19 58 AM
5. desde 42 0 C hasta 43 0 C 0 1 F 0 1 C Una bateria de 1 55 V del tama o de un bot n LR41 o equivalente Menor o igual a 0 09 mW Aproximadamente 200 horas de uncionamiento continuo 5 1 x 0 6 x 0 3 pulg 13 2 x 1 65 x 0 93 cm Aproximadamente 13 gramos incluyendo la bateria PRECAUCIONES No deje caer la unidad ni la someta a golpes No hierva el dispositivo Limpie el dispositivo con alcohol isopropilico No utilice solventes o diluyentes sobre la unidad No guarde la unidad en un lugar expuesto a la luz solar directa o a temperaturas elevadas m No intente desarmar la unidad salvo para reemplazar la bater a GARANT A A amp D Medical garantiza al primer comprador minorista que este term metro digital no tendr defectos de material ni de fabricaci n durante la vida del due o original Esta garant a no cubre las bater as ni el da o resultante del manejo o uso indebido Para obtener un reemplazo por favor devuelva el producto con transporte y seguro prepago junto con la factura de compra y gastos de env o aplicables a LifeSource a la direcci n que figura m s adelante Llame sin cargo a LifeSource Health Line al 1 888 726 9966 para averiguar sobre los gastos de env o y obtener m s informaci n El producto ser reemplazado por uno nuevo o por un producto reparado de valor equivalente a criterio de LifeSource LA GARANT A Y EL RECURSO ANTERIORMENTE MENCIONADOS SON EXCLUSIVOS Y REEMPLAZAN TODA OTRA
6. e alta y prolongada superior a 100 0 F o 37 8 C en ni os peque os requi ere atenci n m dica Si se registraran temperaturas elevadas contacte a su m dico m No permita que los ni os se tomen la temperatura sin supervisi n m Lea cuidadosamente las instrucciones adjuntas para asegurarse de leer en forma cor recta la temperatura Los valores de la temperatura se ven afectados por diversos facto res como el ejercicio la ingesta de bebidas fr as o calientes antes de tomar la medici n y la t cnica que se aplique m No permita que los ni os caminen o corran mientras se les toma la temperatura La rigidez del dispositivo puede resultar riesgosa m Existe aproximadamente una diferencia de 1 F 0 5 C entre la temperatura oral axilar y rectal DT703_SP indd 1 4 CARACTER STICAS ESPECIALES DEL PRODUCTO Mide la temperatura tanto en grados Fahrenheit como en Celsius m Caracter stica de memoria muestra autom ticamente la ltima temperatura regis trada m Emite un sonido cuando alcanza la temperatura pico m Apagado autom tico en aproximadamente 9 minutos m El term metro es resistente al agua pero no 100 a prueba de agua No sumerja la unidad en ning n l quido m Bater a reemplazable de larga duraci n aproximadamente 3 000 mediciones m Indicador de bater a baja Milla m Uso oral rectal o axilar C MO CUIDAR ESTE PRODUCTO m Se debe limpiar el term metro despu s de cada uso a n cuando se u
7. emorar el resultado USO AXILAR AUXILIAR m Limpie la axila con una toalla seca m Ubique el extremo del dispositivo en la axila y baje el Desde el punto de vista m dico este m todo siempre dar un resultado inexacto y no se debe utilizar si se requiere una medici n precisa brazo contra el cuerpo El sensor de medici n debe apuntar hacia arriba paralelo al brazo El tiempo de medici n aproximado puede ser de 5 minutos o m s dependiendo de la ubicaci n del dispositivo y del cierre del brazo contra el cuerpo 3 3 06 10 19 57 AM USO RECTAL m Normalmente se utiliza en beb s ni os peque os o cuando fuera dif cil tomar la temperatura axilar u oral m Despu s de colocar la cubierta en el term metro lubr quelo con una sustancia gelatinosa soluble en agua tal como K Y Jelly m Introduzca suavemente en el recto el extremo del dispositivo no m s de 1 2 pulgada o 1 3 cm No fuerce el extremo hacia el interior del recto si encontrara resistencia m Lave el term metro tal como se recomienda m El tiempo de medici n aproximado es de 60 segundos m Cuando se haya utilizado el term metro en forma rectal no debe utilizarse en forma oral por razones sanitarias INSTRUCCIONES DE LIMPIEZA Despu s de cada uso lave el rea que se extiende a 2 pulg del extremo con agua jabonosa tibia y s quelo completamente O Limpie el rea que se extiende a 2 pulg del extremo con 70 de alcohol isopropilico despu
8. mage resulting from improper handling or use To obtain replacement product please return the product freight and insurance prepaid together with proof of purchase and applicable shipping costs to LifeSource at the address below Call the toll free LifeSource Health Line at 1 888 726 9966 for shipping costs and further information At LifeSources option the product will be replaced with a new or refurbished product of equal value THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES Some states may have laws which amend this warranty A amp D Medical A division of A amp D Engineering 1555 McCandless Drive Milpitas CA 95035 Toll free LifeSource Health Line 1 888 726 9966 www LifeSourceOnline com K Y Jelly is a registered trademark of Johnson amp Johnson LifeSource is a registered trademark of A amp D Medical 2006 A amp D Medical Made in China 3 3 06 10 20 59 AM LIFE SOURCE TERM METRO Dic PANTALLA CUBIERTA DE LA BATERIA EXTREMO DEL SENSOR BOTON DE ENCENDIDO Instrucciones MODELO DT 703 Felicitaciones por haber comprado el Term metro Digital LifeSource Por favor lea las instrucciones cuidadosamente para asegurar la exactitud de las temperaturas y operar de manera segura Si se utiliza de forma adecuada este producto de alta calidad le proporcionar a os de servicio confiable y seguro INFORMACI N DE SEGURIDAD m La fiebr
9. or en la memoria el term metro mostrar durante dos segundos la ltima temperatura registrada Aparecer titilando el s mbolo F o C seguido del s mbolo L o H indicando que el term metro est listo para la medici n Comience la medici n 3 Cuando el s mbolo F o C deje de titilar y el term metro emita ocho sonidos se habr completado la medici n de la temperatura 4 Lea y registre la temperatura y la hora a modo de referencia El registro se guardar autom ticamente en la memoria hasta que se realice otra medici n o se saque la bater a del term metro 5 Presione el bot n de ENCENDIDO para apagar la unidad Si no apaga la unidad el dispositivo se apagar en forma autom tica luego de aproximadamente 9 minutos NOTA Si la temperatura medida es superior a 99 5 F 37 5 C la alarma de fiebre emitir sonidos r pidos durante cerca de cuatro segundos USO ORAL No tome bebidas calientes o fr as no haga ejercicio ni fume ni realice otras actividades que puedan subir o bajar la temperatura La boca debe permanecer cerrada por lo menos durante 5 minutos antes de intentar la medici n Coloque el extremo del dispositivo debajo de la lengua en los lugares indicados en el W ver el diagrama Ense e a los ni os que no deben morder el dispositivo El tiempo de medici n aproximado es de 60 segundos Abrir la boca o colocar de manera inadecuada el extremo del dispositivo puede d
10. tilice el dis positivo con las cubiertas puestas m Limpie el dispositivo y la punta del term metro utilizando alcohol isopropilico o agua y jab n No hierva el term metro No sumerja el term metro en ning n quido Cons rvelo en el estuche protector mientras no lo utiliza o lo guarde en un lugar expuesto a la luz solar directa o a altas temperaturas S lo abra el term metro para reemplazar la bater a No deje caer el term metro ya que la unidad puede romperse o intente desarmar la unidad salvo para reemplazar la bater a CU L ES LA TEMPERATURA NORMAL La temperatura var a seg n la persona La temperatura normal es la temperatura promedio de cada persona mientras se encuentra sano La temperatura normal pro medio var a entre los 97 F 36 1 C a los 100 F 37 7 C cuando se toma en forma oral La temperatura rectal se considera la temperatura real o central del cuerpo La temperatura rectal es 1 F 0 5 C m s alta que la temperatura oral y la axilar es 1 F 0 5 C m s baja que la oral C MO TOMAR LA TEMPERATURA 1 Elija un lugar de medici n ya sea oral axilar o rectal ver las instrucciones siguientes 2 Presione el bot n de ENCENDIDO ubicado en la parte superior del term metro El term metro emitir un sonido y en la pantalla se mostrar n todos los simbo los Esta es una funci n de control que indica que la unidad est funcionando correctamente Si se guard un registro anteri