1. 8 IL1 contaminants in the intake air by generating a plasma of high charge electrons ILI i A This plasma kills and destroys the contaminants completely to provide clean and ED eunt hygienic air Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller Repressing it will deactivate the operation NOTE This feature can be used in any operation mode and any fan speed can be used while plasma filter is functioning 12 Room Air Conditioner Operating Instructions Operation procedures when the remote control can t be used The operation will be started if the ON OFF button is pressed If you want to stop operation re press the button ON OFF button Heat pump Model Cooling Model Room Temp gt 24 C 21 C lt Room Temp lt 24 C Room Temp lt 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use this operation Press and hold the ON OFF button for 3 5 seconds then the buzzer sound 1 beep If you want to stop the operation re press the button Sleep Mode
2. s a menudo en caso de necesidad Un filtro sucio reducir la eficacia del producto Si el producto sufriera fugas de gas refrigerante durante las labores de reparaci n no entre en contacto con el refrigerante El gas refrigerante puede causar lesiones por congelaci n quemaduras por fr o Si el gas refrigerante sufriera fugas durante la instalaci n ventile inmediatamente el rea De lo contrario podr a resultar perjudicial para su salud No recargue ni abra las pilas No las tire al fuego Pueden quemarse o explotar No exponga a los ni os plantas o su propia piel directamente a la corriente de aire fr o o caliente Esto podr a resultar perjudicial para su salud Utilice un taburete o escalera firme al realizar labores de limpieza mantenimiento o reparaci n del producto desde una cierta altura Tenga cuidado y evite las lesiones personales Manual del propietario 5 m Seguridad el ctrica a Seguridad el ctrica A ADVERTENCIA Este pequefio electrodom stico debe estar correctamente puesto a tierra Para reducir al m nimo el riesgo de descargas el ctricas siempre deber enchufar la unidad en una toma con puesta a tierra No corte ni quite la clavija de puesta a tierra del enchufe de alimentaci n Fijar el terminal de puesta a tierra del adaptador al tornillo de la tapa de la toma de pared no pondr a tierra la unidad a menos que el tornillo de la tap
3. There is risk of electric shock or fire Do not store or use or even allow flammable gas or combustibles near the product There is risk of fire If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire When the product is not to be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Do not place ANYTHING on the power cable There is risk of fire or electric shock When flammable gas leaks turn off the gas and open a window for ventilation before turn the product on Do not use the telephone or turn switches on or off There is risk of explosion or fire Two or more people must lift and transport the product Avoid personal injury Keep level even when installing the product To avoid vibration or noise CAUTION D Do not install the product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods It may cause a problem for your neighbors and hence dispute Install the drain hose to ensure that the condensed water is drained away properly A bad connection may cause water leakage Always c
4. de alimentaci n est demasiado caliente o dafiado 3 Se genera un c digo de error mediante el auto diagn stico 4 Fugas de agua en la unidad interior incluso con un nivel de humedad nfimo 5 Todos los interruptores de seguridad puesta a tierra o fusibles sufren aver as y por ende no funcionan correctamente El usuario debe realizar comprobaciones y labores de limpieza a fin de eliminar el riesgo de un mal funcionamiento ALIMENTACI N 220 V 60 Hz AL SER ESTE UN MANUAL MULTI MODELO ES NECESARIO VERIFICAR EL CONSUMO DE CORRIENTE Y POTENCIA EN LA ETIQUETA ADHERIDA A SU PRODUCTO Manual del propietario 17 LG Electronics Inc LG ELECTRONICS MEXICO S A DE C V Sor Juana In s de la Cruz No 555 Col San Lorenzo Tlalnepantla Estado de M xico Tel fono 55 5321 1919 Sin costo 01800 3471919 Impreso en China
5. manguera de desag e para asegurar que el agua condensada se drene correctamente Una mala conexi n puede causar fugas de agua Compruebe siempre si existen fugas de gas refrigerante tras la instalaci n o reparaci n del producto Los niveles bajos de refrigerante pueden causar aver as en el producto 4 Aire acondicionado Precauciones de seguridad No utilice el producto con prop sitos especiales como la preservaci n de alimentos obras de arte etc Este es un aire acondicionado de consumidor no un sistema de refrigeraci n de precisi n Existe el riesgo de da os o p rdidas de propiedad No toque las piezas met licas del producto al desmontar el filtro de aire Existe el riesgo de lesiones personales No introduzca las manos u otros objetos en la entrada o la salida de aire mientras el producto est en funcionamiento Existen piezas afiladas y m viles que podr an causar lesiones personales No incline la unidad durante los procesos de desmontaje o desinstalaci n El agua condensada del interior podr a verterse El desmontaje de la unidad el tratamiento del aceite refrigerante y de distintas piezas deber realizarse conforme a las normativas locales y nacionales Si el l quido de las pilas entra en contacto con su piel o ropas l vese bien con agua limpia No utilice el mando a distancia si las pilas han experimentado fugas Los productos qu micos de las pilas p
6. otro modo Siga los pasos 1 y 2 para ejecutar el funcionamiento autom tico Consulte el modo de funcionamiento Manual del propietario 11 Instrucciones de funcionamiento La funci n de chorro de aire fr o puede ser empleada para enfriar r pidamente un cuarto en un d a caluroso Cuando esta funci n est activa el aire acondicionado funcionar en modo PO operaci n de enfriamiento con una velocidad ultrarr pida del ventilador y una temperatura de ummi 18 C durante 30 minutos a fin de lograr un enfriamiento r pido y eficaz De forma similar la funci n de chorro de aire caliente disponible nicamente en algunos modelos calienta r pidamente el cuarto mediante la operaci n del ventilador a una velocidad ultrarr pida y a una temperatura de 30 C durante 60 minutos Podr activar este funcionamiento presionando el BOT N JET COOL enfriamiento por chorro de aire Para cambiar del modo enfriamiento por chorro de aire al modo enfriamiento por velocidad alta del ventilador presione de nuevo el BOT N JET COOL o BOT N SELECTOR DE VELOCIDAD DEL VENTILADOR INTERIOR o el BOT N DE AJUSTE DE TEMPERATURA AMBIENTE NOTA La funci n Jet cool function no puede ser activada durante las operaciones de cambio a de calefacci n o autom tico En el caso de los modelos Inverter Art Cool y Art Cool Wide no Deluxe podr utilizar la funci n calefacci n por chorro de aire caliente presionando el BOT N JET COOL pa
7. suave para limpiarlo 3 Si el mando a distancia opera adem s otros equipos cambie su posici n o consulte al t cnico de servicio 1 El receptor de se al se encuentra en el interior de la unidad 2 Apunte a la unidad con el mando a distancia a fin de ponerla en funcionamiento No deben existir obst culos entre ambos 8 Aire acondicionado Instrucciones de funcionamiento Los controles ser n id nticos a los siguientes 1 BOT N START STOP Utilizado para encender apagar la unidad 2 BOT N DE SELECCI N DEL MODO DE FUNCIONAMIENTO Transmisor de senal Utilizado para seleccionar el modo de funcionamiento 3 BOTONES DE AJUSTE DE LA TEMPERATURA AMBIENTE Utilizados para configurar la temperatura ambiente 4 BOT N SELECTOR DE VELOCIDAD DEL VENTILADOR INTERIOR Utilizado para seleccionar la velocidad del ventilador en cuatro pasos bajo medio alto y CAOS 5 BOT N JET COOL enfriamiento r pido Utilizado para iniciar o parar la velocidad de enfriamiento Opera el ventilador en velocidad s per r pida en modo enfriamiento m 6 BOT N CHAOS SWING 1 Utilizado para iniciar o cesar el movimiento de las palas y configurar la direcci n arriba abajo deseada del flujo de aire 7 BOTONES DE ENCENDIDO APAGADO DEL TEMPORIZADOR 3 Utilizados para configurar el tiempo de inicio y cese del r funcionamiento 8 BOTONES DE CONFIGURACI N HORARIA 10 Utilizados para ajustar
8. supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts 2 Hoom Air Conditioner Safety Precautions Bj Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed W Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications 7 AWARNING This symbol indicates the possibility of death or serious injury EN A CAUTION This symbol indicates the possibility of injury or damage M E Meanings of symbols used in this manual are as shown below NS Be sure not to do _ 0 Be sure to follow the instruction Always use a power plug and socket with a ground terminal There is a risk of electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product by yourself There is risk of fire or electric shock Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not install the product on a defective installation stand Be sure that the installation area does not deteriorate with age e It may cause product to fall In outdoor
9. the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic 10 Room Air Conditioner Operating Instructions Healthy Dehumidif ia 0 E pm During Healthy Dehumidification Operation Q If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON the product starts to run the dehumidification mn function It automatically sets the room temperature and airflow volume to H h the best condition for dehumidification based on the sensed current room ealt y temperature Dehumidification n this case however the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either XAOS Q During the healthy dehumidification function the airflow volume is V automatically set according to the optimization algorithm responding to the current room temperature status so that the room condition is kept healthy and comfortable even in the very humid season To run the healthy dehumidification mode follow steps 1 and 2 and 4 See operation mode Auto Operation In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature If you feel hot or cold press the temperature setting buttons respectively for more cooling or heating effect NOTE You cannot set the actual setting temperature and the
10. to the cool or hot air draft This could harm to your health Use a firm stool or ladder when cleaning maintaining or repairing the product at an height Be careful and avoid personal injury Owner s Manual 5 Electrical Safety E Electrical Safety A WARNING This appliance must be properly grounded To minimize the risk of electric shock you must alway plug into a grounded oulet Do not cut or remove the grounding prong from the power plug Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring If you have any doubt whether the air conditioner is properly grounded have the wall receptacle and circuit checked by a qualified electrician Temporary We strongly discourage the use of an adapter due to potential safety hazards For temporary connections use only a genuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage A WARNING Never use the appliance with a broken adapter Temporary We strongly discourage the
11. A Purification Operation Optional eee eer 12 Forced operationis e m eee 13 rocas 13 Vertical Horizontal Airflow Direction Control Optional Air Circulation Mode Auto Restart Function Self Diagnosis Function 16 Troubleshooting Tips Save time and money 17 Call the service immediately in the following situations J FOR YOUR RECORDS Write the model and serial numbers here Model Serial You can find them on a label on the side of each unit Dealer s Name Date Purchased W Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues yo READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be
12. OM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 PLASMA BUTTON Used to start or stop the plasma purification function 14 RESET BUTTON Used prior to resetting time A Owner s Manual 9 Operating Instructions Operation Mode f Press the START STOP BUTTON to O turn the unit on The unit will respond with a beep y ri i Lc uii Open the door of the remote controller and press the operation mode button Each time the button is pressed the operation mode is shifted in the direction of the arrow Pg mI 8 3j Cooling Auto Healthy Heating Operation Dehumidiicaon Heat pump muda only For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE To raise the temperature SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C To lower the temperature Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON Each time the button is pressed the fan speed mode is shifted gt E umi sull CHAOS Air Fan speed is on low Fan speed is on medium Fan speed is on high Natural wind by the CHAOS logic 1 For fresher feeling press the INDOOR FAN SPEED SELECTOR BUTTON selector and set to CHAOS mode In this mode
13. There is risk of fire electric shock explosion or injury When the product is soaked flooded or submerged in water contact an Authorized Service Center for repair before using it again There is risk of fire or eletric shock Be sure to use only those parts which are listed in the svc parts list Never attempt to modify the equipment The use of inappropriate parts can cause an electrical shock excessive heat generation or fire Owner s Manual 3 Safety Precautions Indoor outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals e Improper or loose connections can cause heat generation or fire Be sure to check the refrigerant to the used Please read the label on the product Incorrect refrigerant used can prevent the normal operation of the unit Do not place a heater or other heating appliances near the power cable There is risk of fire and electric shock Do not use the product in a tightly closed space for a long time Perform ventilation regularly Oxygen deficiency could occur and hence harm your health Ventilate the product room from time to time when operating it together with a Stove or heating element etc Oxygen deficiency can occur and hence harm your health Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit
14. This could result in personal injury and product damage Do not plug or unplug the power supply plug to turn the unit ON OFF There is risk of fire or electric shock Safely dispose off the packing materials Like screws nails batteries broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags Children may play with them and cause injury Don t use a power cord a plug or a loose socket which is damaged Otherwise it may cause a fire or electrical shock Do not allow water to run into electric parts Install the unit away from water Sources There is risk of fire failure of the product or electric shock Do not open the front grille of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric shock or product failure Turn the main power off and unplug the unit when cleaning or repairing the product There is risk of electric shock Take care to ensure that power cable could not be pulled out or damaged during operation There is risk of fire or electric shock Make sure to check that the power cable plug is not dirty loose or broken and then only insert the plug completely Dirty loose or broken power plug can cause electric shock or fire Do not touch operate or repair the product with wet hands Hold the plug by hand when taking out
15. a evitar que el aire fr o se escape de la unidad En modo descongelaci n la unidad cesa su funcionamiento de calefacci n durante diez minutos a fin de eliminar cualquier formaci n de hielo en las bobinas del intercambiador de calor y mantener as su nivel de eficacia Cables de conexi n Conductos de refrigerante Orificios de salida de aire Placa base Manguera de drenaje Manual del propietario 7 Instrucciones de funcionamiento B Instrucciones de funcionamiento 1 Desmonte la tapa de la bater a tirando de ella en la direcci n de la flecha 2 Inserte las nuevas pilas asegur ndose de que los signos y de la pila est n instalados correctamente 3 Monte de nuevo la tapa desliz ndola nuevamente en posici n NOTA 1 Utilice Sustituya siempre ambas pilas por otras del mismo tipo 2 Si no piensa utilizar el sistema durante un largo per odo de tiempo retire las pilas a fin de extender su vida util 3 Si la informaci n en la pantalla del mando a distancia comenzara a desvanecerse sustituya ambas pilas 1 Seleccione para ste un lugar seguro y de f cil acceso 2 Fije el soporte a la pared mediante los tornillos incluidos 3 Deslice el mando a distancia en su soporte NOTA 1 El mando a distancia nunca debe ser expuesto a la luz directa del sol 2 Debe mantener siempre limpio el transmisor receptor de se al a fin de asegurar una correcta comunicaci n Emplee un pafio
16. a sea met lico y no est aislado y la toma de pared est puesta a tierra a trav s del cableado de la casa Si tiene alguna duda sobre si el aire acondicionado est puesto a tierra correctamente solicite a un electricista cualificado que revise la toma de pared y el circuito Desaconsejamos firmemente el uso de un adaptador debido a los potenciales peligros de seguridad En conexiones temporales utilice Unicamente un adaptador original disponible en la mayor a de sus almacenes locales de ferreteria Aseg rese que la ranura grande del adaptador est alineada con la ranura grande de la toma para realizar una conexi n correcta de la polaridad Para desconectar el cable de alimentaci n del adaptador coloque una mano en cada uno para evitar dafiar la clavija de puesta a tierra Evite desenchufar con frecuencia el cable de alimentaci n ya que esto podr a provocar da os eventuales a la clavija de puesta a tierra A ADVERTENCIA No utilice nunca la unidad con un adaptador roto No aconsejamos el uso de una extensi n de alimentaci n debido a potenciales peligros de seguridad A ADVERTENCIA Este pequefio electrodom stico debe instalarse conforme a las normativas nacionales de cableado el ctrico Este manual act a como gu a para ayudar a explicar las caracter sticas de producto A Este simbolo le alerta del riesgo de descarga el ctrica Este s mbolo le alerta de los peligros que pueden causar da os al A aire aco
17. aci n de la unidad De lo contrario la unidad podr a caer y causar lesiones severas No utilice un multiconector Utilice siempre este electrodom stico en un circuito e interruptor dedicado De lo contrario podr a ser causa de incendio 0 descarga el ctrica Instale firmemente el panel y la cubierta de la caja de control Existe riesgo de incendio o descarga el ctrica debido a la acumulaci n de polvo agua etc Para las labores de instalaci n desmontaje o reinstalaci n entre siempre en contacto con el distribuidor o un centro de servicio autorizado Existe riesgo de incendio descarga el ctrica explosi n o lesiones Si el producto estuviera mojado debido a inundaciones etc p ngase en contacto con el centro de servicio autorizado para realizar labores de reparaci n antes de volver a utilizar el producto Existe riesgo de incendio o descarga el ctrica Aseg rese de utilizar nicamente aquellas piezas listadas en la lista de piezas del circuito virtual conmutado SVC Nunca intente modificar el equipo El uso de piezas no adecuadas puede ser causa de descarga el ctrica generaci n excesiva de calor o incluso incendio Manual del propietario 3 Precauciones de seguridad Las conexiones del cableado interior exterior deben estar firmemente aseguradas y el cable deber tenderse correctamente a fin de evitar tensiones no deseadas en los terminales de conexi n Las co
18. arantiza un fant stico rendimiento y el nivel de servicio m s adecuado para hacer su vida m s c moda y agradable IMPORTANTE Por favor lea este manual del propietario cuidadosamente y a fondo antes de instalar y hacer funcionar su aire acondicionado Por favor conserve el manual del propietario para referencias futuras tras su lectura a fondo Manual del propietario del aire acondicionado CONTENIDO A Precauciones de seguridad 3 B Seguridad el ctrica Uso temporal de un adaptador Uso temporal de una extensi n de alimentaci n S mbolos utilizados en este manual C Presentaci n del producto Unidades interiores Indicadores luminosos de funcionamiento 7 Unidad exterior D Instrucciones de funcionamiento Inserci n de pilas Mantenimiento del mando a distancia inal mbrico M todo de funcionamiento Mando a distancia inal mbrico Modo funcionamiento Funcionamiento de deshumidificaci n Funcionamiento autom tico Operaci n de cambio autom tico Operaci n del enfriamiento por chorro de aire is 12 Funcionamiento de purificaci n NEO PLASMA opcional ail Funcionamiento Forzado Modo de reposo Control de direcci n vertical horizontal del flujo de aire Opcional Modo circulaci n de aire Funci n de reinicio autom tico E Mantenimiento y servicio Unidad interior Unidad exterior Sugerencias Funci n
19. caliente por encima de los 40 C Podr a causar la deformaci n y o decoloraci n de la unidad Sustancias vol tiles Podr an da ar la superficie del aire acondicionado Filtros de aire Los filtros de aire tras el panel rejilla frontal deber n revisarse y limpiarse una vez cada 2 semanas o m s a menudo si es necesario Consulte los diagramas auto explicativos para cada tipo de modelo a fin de saber c mo retirar los filtros Limpie los filtros con una aspiradora o con agua templada y jabonosa Si la suciedad a n resulta notable lave el producto con una soluci n de detergente y agua templada D jelos secar a la sombra y vuelva a instalar los filtros en su lugar una vez secos Filtros de plasma Los filtros de plasma tras el filtro de aire deber n revisarse y limpiarse una vez cada 3 meses o m s a menudo si fuera necesario Consulte los diagramas auto explicativos para cada tipo de modelo a fin de saber c mo retirar los filtros Limpie los filtros con una aspiradora Si la suciedad a n resulta notable lave el producto con agua templada y d jelos secar a la sombra y vuelva a instalarlos en su lugar Filtros desodorantes Retire los filtros desodorantes tras el filtro de aire y exp ngalos a la luz directa del sol durante 2 horas A continuaci n vuelva a insertar los filtros en su posici n original Desmontaje de filtros Abra el panel frontal como se muestra A continuaci n extraiga levemente hacia delante la leng e
20. cionar la temperatura 22 C Operaci n de prueba Durante la OPERACI N DE PRUEBA la unidad opera en el modo de refrigeraci n con el ventilador de alta velocidad sin tener encuenta la temperatura y restaura en 18 minutos Durante la operaci n de prueba si se recibe la senal del control remoto la unidad opera como fije el control remoto Si desea utilizar esta operaci n abra hacia arriba el panel delantero y mantenga presionado el bot n ON OFF durante 3 5 segundos Despu s se emitir un pitido 1 beep Si desea detener la operaci n vuelva a presionar el bot n 1 Presione el BOT N MODO REPOSO AUTOM TICO para configurar la hora a la que desea que la unidad se lt gt apague autom ticamente 2 El temporizador se programa en incrementos de una hora presionando el BOT N MODO REPOSO AUTOM TICO de 1 a 7 veces El modo reposo est disponible de 1 a 7 veces Para alterar el per odo de tiempo en incrementos de 1 hora presione el BOT N MODO REPOSO AUTOM TICO mientras apunta con el mando al aire acondicionado 3 en el modelo sin convertidor Aseg rese de que est n iluminados los indicadores LED del modo Apagado Para cancelar el modo apagado pulse el bot n SLEEP MODE AUTO hasta que se apaguen los indicadores LED del modo Apagado NOTA El modo reposo operar el ventilador interior a baja velocidad en modo enfriamiento y a velocidad media en modo calefacci n para lograr un descanso agradable Art C
21. d Visit us at http www lgservice com LG Room Air Conditioner OWNER S MANUAL MODELS SP122CM syo SP182CM ss SP242CM ss SP122HM sv SP182HM s SP242HM ss d c PR G A AF ANM 3 ks Dear Owner Thank you for installing LG air conditioner Your best choice guarantees you a great performance and service to make your life comfortable amp pleasant IMPORTANT Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly P No MFL42996105 Room Air Conditioner Owner s Manual TABLE OF CONTENTS A Safety Precautions 3 BE emere 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction a IndoonlUnits tee eren sconce oer 7 Operation Indication Lamps all Outdoor nite secre eee 7 D Operating Instructions 8 How to insert the Batteries 8 Wireless Remote Controller Maintenance sss 8 Operating Method 8 Wireless Remote Controller 9 Operation Mode 10 Healthy Dehumidification Operation 11 INTO Operation 11 Auto Changeover Operation 11 Jet Cool Heat Operation NEO PLASM
22. de auto diagn stico Consejos de soluci n de aver as Ahorre tiempo y dinero DPD AA A Solicite servicio inmediatamente en las siguientes circunstancias 17 J PARA SUS ARCHIVOS Escriba el n mero de modelo y el n mero de serie aqu N de modelo N de serie Podr encontrarlos en una etiqueta en el lateral de cada unidad Nombre del distribuidor Fecha de compra W Adjunte y engrape su recibo a esta p gina en caso de necesitar probar la fecha de compra o por motivos de la garant a LEA ESTE MANUAL Dentro encontrar muchas sugerencias tiles sobre el uso y mantenimiento correcto del aire acondicionado Apenas unos simples cuidados preventivos de su parte pueden ahorrarle mucho tiempo y dinero a lo largo de la vida til de Su aire acondicionado Encontrar muchas respuestas a los problemas comunes en el gr fico de sugerencias para la soluci n de aver as Si examina antes su tabla de Sugerencias para la soluci n de aver as puede que no necesite llamar al servicio t cnico PRECAUCI N Entre en contacto con un t cnico de servicio autorizado para realizar la reparaci n o el mantenimiento de esta unidad Entre en contacto con el instalador para la instalaci n de esta unidad El aire acondicionado no est dise ado para su uso por nifios pequefios o personas discapacitadas sin supervisi n Los nifios pequefios debe
23. ditioner ERR T INL Clean the filter at least every 2 weeks oy a ME See the Maintenance and Service section Air W The room may have been hot When the air conditioner is first turned on conditioner you need to allow time for the room to cool does not cool down itshoud MA EE A oo eating RS tenella W Cold air is escaping Check for open furnace floor registers and cold air returns E There might be any heating Check and remove such source or turn it source in the room off while using the air conditioner Call the service n 1 1 Anything abnormal such as burning smell loud noise etc happen Stop the unit and turn the breaker off Never try to repair by yourself or restart the system in such cases 2 Main power cord is too hot or damaged 3 Error code is generated by self diagnosis 4 Water leaks from indoor unit even if the humidity is low 5 Any switch breaker safety earth or fuse fails to work properly User must carry routine checkup amp cleaning to avoid unit s poor performance In case of special situation the job must be carried out by service person only Owner s Manual 17 d Visit us at http www lgservice com LG Aire acondicionado MANUAL DEL PROPIETARIO MODELOS SP122CM svo SP182CM s51 SP242CM ss1 SP122HM sv SP182HM sso SP242HM ss c 7 gt ES AA J3 VA M IS 3 3 k Estimado usuario Gracias por instalar el aire acondicionado Su mejor selecci n le g
24. e el aire acondicionado est enchufado completamente en la salida Compruebe el fusible interruptor y sustituya el interruptor o reinicio el interruptor Si experimenta una ca da de tensi n apague el modo de control Cuando se restablezca la tensi n espere 3 minutos para reiniciar el aire acondicionado y evitar la desconexi n de sobrecarga del compresor Si la tensi n fuera inusualmente muy alta o muy baja el interruptor se desconectar a El aire acondicionad ono enfria como deberia W E flujo de aire est restringido W El cuarto puede haber estado muy caliente W Compruebe los ajustes de temperatura W Puede existir otra fuente de calor en el cuarto Aseg rese que no existen cortinas persianas o mobiliario bloqueando la parte frontal del aire acondicionado Limpie el filtro al menos cada 2 semanas Consulte la secci n Servicio y Mantenimiento Al encender por primera vez el aire acondicionado necesitar dejar pasar un tiempo hasta que el cuarto se enfr e Revise los registros de calor abierto y los retornos de aire fr o Compruebe la existencia y retire tal fuente o descon ctela durante el uso del aire acondicionado 1 Toda condici n fuera de lo com n como el olor a quemado ruidos etc debe incluir una desconexi n de la unidad y del interruptor No intente nunca reparar la unidad usted mismo o reiniciar el sistema en tales casos 2 El cable principal
25. emote controller towards the unit to operate it There should not be any blockage in between 8 Room Air Conditioner Operating Instructions The controls will look like the following P Signal transmitter LL RBBB RIBBE 5 1 6 3 4 10 9 T 12 8 13 14 L Flip up door opened Cooling Operation Us Auto Operation Us Healthy Dehumidification Operation y Heating Operation xx Cooling Model lt Heat Pump Model START STOP BUTTON Used to turn off on the unit 2 OPERATION MODE SELECTION BUTTON Used to select the operation mode 3 ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature INDOOR FAN SPEED SELECTOR BUTTON Used to select fan speed in four steps low medium high and CHAOS 5 JET COOL BUTTON Used to start or stop the speed cooling It operates fan in super high speed in cooling mode 6 CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction 7 ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation 8 TIME SETTING BUTTONS Used to adjust the time 9 TIMER SET CANCEL BUTTON Used to set and to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating 12 RO
26. from unit n defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchanger coils to maintain the efficiency Outdoor Unit Air intake vents y Connecting wires Refrigerant pipes Air outlet vents Base plate Drain hose Owner s Manual 7 Operating Instructions B Operating Instructions 1 Remove the battery cover by pulling it according to the arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by sliding it back into position NOTE 1 Always use replace both batteries of same type 2 If the system is not to be used for a long time remove the batteries to save their working life 3 If the display screen of remote controller starts fading replace both of the batteries Wireless Remi 1 Choose a suitable place where its safe amp easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder NOTE 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter amp receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case some other appliances also get operated with remote control change their position or consult your serviceman Operating M 1 The signal receiver is inside the unit 2 Aim the r
27. good idea cooling capacity when the possible to keep the cool lower cooling and to open them and fan speed is high air in the room dehumidifying effects ventilate the room now Clean at least once every and ten two weeks Self Diagn This unit has an inbuilt error diagnosis capability Unit LED DM will blink in case if thermistor fails Please contact your serviceman dealer in such a situation Error Display LED T Check Point once Indoor room temperature thermistor open short Indoor pipe temperature thermistor open short 3 sec 3 sec 3 sec 16 Room Air Conditioner Maintenance and Service Troubleshooting The air conditioner may be operating abnormally when Possible Causes What To Do W The air conditioner is Make sure the air conditioner plug is unplugged pushed completely into the outlet W The fuse is blown circuit Check the house fuse circuit breaker box breaker is tripped and replace the fuse or reset the breaker Air W Power failure If power failure occurs turn the mode conditioner control to OFF does not start When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload W High voltage If the voltage is unusually very high or low the circuit Breaker will trip Make sure there are no curtains blinds or moo tase dl furniture blocking the front of the air con
28. heck for gas refrigerant leakage after installation or repair of product Low refrigerant levels may cause failure of product 4 Hoom Air Conditioner Safety Precautions Do not use the product for special purposes such as preserving foods works of art etc It is a consumer air conditioner not a precision refrigeration system There is risk of damage or loss of property Do not touch the metal parts of the product when removing the air filter There is risk of personal injury Do not insert hands or other objects through the air inlet or outlet while the product is operating There are sharp and moving parts that could cause personal injury Do not tilt the unit when removing or uninstalling it The condensed water inside can spill Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards If the liquid from the batteries gets onto your skin or clothes wash it well with clean water Do not use the remote if the batteries have leaked The chemicals in batteries could cause burns or other health hazards Do not drink the water drained from the product Itis not sanitary and could cause serious health issues Do not block the inlet or outlet of air flow It may cause product failure Do not step on or put anyting on the product outdoor units There is risk of personal injury and failure of
29. i D 1 Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically ES 2 The timer is programmed in one hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times Sy The sleep mode is available for 1 to 7 times To alter the time period in steps of 1 hour press the SLEEP MODE AUTO BUTTON while aiming at air conditioner 3 In case of non Inverter Model Make sure the sleep mode LED lights up To cancel the sleep mode press the SLEEP MODE AUTO BUTTON several times until the sleep mode LED lights off NOTE The sleep mode will operate indoor fan at slow speed in cooling mode and at medium speed in heating mode for pleasant sleep Art Cool and Art Cool Wide non Deluxe close the lower discharge partially in sleep mode for pleasant sleep In cooling mode or healthy dehumidification mode The setting temperature will rise automatically two times by 1 C over next consecutive 30 minutes 2 C in 1 hour for a comfortable sleep Now this will be the final setting temperature as long as sleep mode is functioning Owner s Manual 13 Operating Instructions Vertical Horizontal The up down airflow Vertical airflow can be adjusted by using the remote controller 1 Press the START STOP BUTTON to start the unit i 2 Press CHAOS SWING BUTTON 3 The louvers will swing up amp down automatically 4 To stop the louver at a desired e angle press R again By press
30. indoor fan Auto speed in this operation mode But you can use the Chaos swing in this operation If the system is not operating as desired switch manually to another mode To run the auto operation follow steps 1 and 2 See operation mode Owner s Manual 11 Operating Instructions Jet Cool Heat O aK Jet cool function can be used to cool the room quickly in hot summer When this n function is turned on the air conditioner runs in cooling operation mode with super L high fan speed and 18 C setting temperature for 30 minutes for fast and effective mutt cooling Similarly jet heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes You can activate this operation by pressing the JET COOL BUTTON To change from jet cool mode to high fan speed cooling mode press the JET COOL BUTTON or INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again NOTE Jet cool function cannot be activated during heating or auto changeover operations In case of Inverter Art Cool and Art Cool Wide non Deluxe model you can use jet heat function by pressing JET COOL BUTTON for heating operation Art Cool and Art Cool Wide models close the side discharges during jet cool heat operation for strong cooling and heating NEO PLASMA le Plasma filter is a technology developed by LG to get rid of microscopic
31. ing the CHAOS SWING BUTTON the horizontal air flow direction is changed automatically based on the chaos algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying natural breeze This operation circulates the air without cooling or heating It can be activated by pressing the AIR CIRCULATION BUTTON Once the air circulation is activated you can select the air speed by pressing the INDOOR FAN SPEED SELECTOR BUTTON CHAOS Air economizes power consumption and prevents overcooling The fan speed is automatically changed from high to low or vice versa depending on the ambient temperature In case of inverter type models where there is no AIR CIRCULATION BUTTON air circulation can be operated by pressing the PLASMA BUTTON Auto Restart Fun This function is useful in the situation of power failure When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings This feature is enabled by factory default setting but you can disable it by pressing the ON OFF button for 6 seconds The unit will beep twice and the indicator lamp 2 will blink 4 times To enable it press the button again for 6 seconds The unit will beep twice and the indicator lamp 1 will blink 4 times 14 Room Air Conditioner Maintenance and Service N Maintenance and Service A CAUTION Before perfo
32. l ventilador puertas y ventanas con regularidad ocasionalmente a alta velocidad para est n bien cerradas lograr un enfriamiento r pido y eficaz En lo posible vite abrir Las obstrucciones en el filtro Como las ventanas Cuando la velocidad del puertas y ventanas para de aire reducen el flujo de permanecen cerradas ventilador sea alta la mantener el aire fr o en el aire y reduce los efectos de es buena idea abrirlas unidad proporcionar su interior del habit culo enfriamiento y para ventilar el cuarto de capacidad nominal de deshumidificaci n L mpielo vez en cuando enfriamiento al menos cada dos semanas Esta unidad tiene una prestaci n incorporada de diagn stico de error El LED D de la unidad parpadear en caso de aver a del termistor Si experimentara estas condiciones por favor contacte con su t cnico distribuidor LED de muestra de error Punto de control una vez Termistor de temperatura ambiente interior abierto cortocircuitado Termistor de temperatura de los conductos 356 3 sec 3 sec interiores abierto cortocircuitado 16 Aire acondicionado Mantenimiento y servicio El aire acondicionado puede funcionar de forma poco normal cuando El aire acondicionad o no se inicia E E aire acondicionado est desenchufado W El fusible est fundido el interruptor est activado W Ca da de tensi n W Alta tensi n Aseg rese qu
33. la hora 9 BOT N DE CONFIGURACI NICANCELACI N DEL 42 TEMPORIZADOR Utilizado para establecer y cancelar el funcionamiento del temporizador 10 BOT N DEL MODO REPOSO Utilizado para configurar el funcionamiento autom tico del modo reposo 11 BOT N DE CIRCULACI N DE AIRE Utilizado para hacer circular el aire del cuarto sin enfriarlo ni calentarlo Puerta de apertura 12 BOT N DE COMPROBACI N DE TEMPERATURA AMBIENTE independiente tipo Utilizado para comprobar la temperatura ambiente flip up abierta 13 BOTO B DE PLASMA Utilizado para configurar el inicio o cese de la funci n de purificaci n por plasma 14 BOT N RESET Utilizado antes del tiempo de restablecimiento 11 13 14 3 Modo funcionamiento Modo funcionamiento Us Funcionamiento autom tico Us Funcionamiento de deshumidificaci n sana y Funcionamiento de calefacci n Xt Modelo enfriamiento Modelo bomba de calor 4 Manual del propietario 9 Instrucciones de funcionamiento Presione el bot n Start Stop para encender la unidad La unidad responder con una se al sonora Ir Lic uii Abra la puerta del mando a distancia y presione el bot n modo de funcionamiento Cada vez que presione el bot n el modo de funcionamiento cambiar en la direcci n de la flecha Pg mI 8 35 Enfriamiento Funcionamiento Deshumidificaci n Ca
34. lefacci n autom tico sana S lo el modelo bana de calor Establezca la temperatura interior deseada para la operaci n de enfriamiento o calefacci n presionando los BOTONES DE Aumentar la temperatura AJUSTE DE TEMPERATURA AMBIENTE La temperatura de enfriamiento debe establecerse entre los 18 C y los 30 C y para la calefacci n entre los 16 C y los 30 C Reducir la temperatura Establezca la velocidad del ventilador mediante el mando a distancia Usted puede seleccionar la velocidad del ventilador en cuatro pasos bajo medio alto y CAOS Cada vez que presione el bot n cambiar el modo de velocidad del ventilador unm sull CHAOS Air La velocidad del La velocidad del La velocidad del ventilador es baja ventilador es media ventilador es alta Viento natural por l gica CAOS 1 Para lograr una sensaci n m s fresca presione el BOT N SELECTOR DE VELOCIDAD DEL VENTILADOR INTERIOR y configure el modo CAOS En este modo el viento sopla como una brisa natural cambiando autom ticamente la velocidad del ventilador seg n la l gica CAOS 10 Aire acondicionado Instrucciones de funcionamiento Funcionamiento d Durante el funcionamiento de la deshumidificaci n sana Si selecciona el modo deshumidificaci n mediante el BOT N DE SELECCI N DEL MODO DE FUNCIONAMIENTO el producto activar la funci n de mn deshumidificaci n Establece aut
35. n estar supervisados para asegurarse que no jueguen con el aire acondicionado e Si el cord n de alimentaci n es da ado ste debe sustituirse por el fabricante o su agente de servicio autorizado con el fin de evitar un peligro 2 Aire acondicionado Precauciones de seguridad Jj Precauciones de seguridad Para evitar lesiones al usuario u otras personas o dafios a la propiedad deber seguir las siguientes instrucciones HEI funcionamiento incorrecto debido a la omisi n de las instrucciones causar lesiones o da os La seriedad se clasificar mediante las siguientes indicaciones ADVERTENCIA Este s mbolo indica la posibilidad de muerte o lesi n seria A ATENCION Este s mbolo s lo indica la posibilidad de lesi n o da os a la propiedad M y W El significado de los s mbolos utilizados en este manual se muestra a continuaci n MS Aseg rese de no hacer esto 0 Aseg rese de seguir las instrucciones Utilice siempre un enchufe y una toma de alimentaci n con el terminal de tierra Existe riesgo de descarga el ctrica Para trabajos el ctricos entre en contacto con el distribuidor el vendedor un electricista cualificado o un centro de servicio autorizado No desmonte o repare el producto usted mismo Existe riesgo de incendio o descarga el ctrica Utilice un interruptor o fusible de la capacidad correcta Existe riesgo de i
36. ncendio o descarga el ctrica No instale el producto sobre un soporte de instalaci n defectuoso Aseg rese que el rea de instalaci n no se deteriora con el tiempo Podr a provocar aver as en el producto El condensador de aumento de la unidad exterior suministra electricidad de alta tensi n a los componentes el ctricos Aseg rese de descargar completamente el condensador antes de realizar tareas de reparaci n Un condensador cargado de electricidad puede causar descargas el ctricas C A ADVERTENCIA No utilice un interruptor defectuoso o de capacidad equivocada Utilice un interruptor y fusible de la capacidad correcta Existe riesgo de incendio o descarga el ctrica Ponga siempre el producto a tierra conforme al diagrama de cableado No conecte el cable de puesta a tierra a los cables de tierra de los conductos de agua gas del pararrayos o tel fono Existe riesgo de incendio o descarga el ctrica No modifique ni alargue el cable de alimentaci n Si el cable de alimentaci n sufriera da os estuviera pelado o deteriorado deber sustituirse por otro en perfecto estado Existe riesgo de incendio o descarga el ctrica No instale nunca la unidad exterior sobre una base m vil o en un lugar del que podr a caerse La ca da de la unidad exterior podr a causar da os lesiones o incluso la muerte Utilice el equipo de instalaci n incluido con el producto durante la instal
37. ndicionado NOTA Este simbolo indica notas especiales 6 Aire acondicionado Presentaci n del producto A Presentaci n del producto A continuaci n encontrar una breve presentaci n de las unidades de interior y exterior Por favor consulte la informaci n espec fica relativa al tipo de su unidad interior Tipo Split est ndar unidad separada Indicadores LED en el panel de visualizaci n Entrada de aire Leng eta de la rejilla Filtro de plasma opcional Rejilla frontal Bot n ON OFF encendido apagado Filtro de aire Salida de aire palas verticales Pesta a pala horizontal O Encendido Se encender durante el funcionamiento del sistema en caso de c digo de error apagado y ajuste de reinicio autom tico SS Modo reposo Se enciende durante el funcionamiento autom tico del modo reposo Modelo no inversor ERR Plasma La funci n ilustra su modo din mico utilizando un sistema de iluminaci n multiple x Modo Se enciende durante el modo descongelaci n o el Arranque en caliente descongelaci n S lo modelo bomba de calor OUT Funcionamiento Se enciende durante el funcionamiento al aire libre de la unidad DOOR de unidad exterior S lo modelo de enfriamiento BH Pantalla digital Indica la temperatura y el modo de funcionamiento configurado Arranque en caliente Cesa durante algunos minutos el funcionamiento del ventilador interior en la funci n de calefacci n par
38. nexiones flojas o inadecuadas pueden ser causa de una generaci n excesiva de calor o incluso incendio Aseg rese de comprobar el tipo de refrigerante empleado Por favor lea la etiqueta informativa del producto El uso de un refrigerante incorrecto podria evitar el funcionamiento normal de la unidad No coloque un radiador u otros electrodom sticos generadores de calor cerca del cable de alimentaci n Existe riesgo de incendio o descarga el ctrica No utilice el producto en un espacio cerrado durante mucho tiempo Realice peri dicamente la ventilaci n del producto e Podr a sufrir una carencia de ox geno y consecuentemente sufrir dafios en su salud Ventile peri dicamente el cuarto donde se encuentra el producto siempre que funcione cerca de una estufa elemento calefactor etc e Podr a sufrir una carencia de ox geno y consecuentemente sufrir dafios en su salud Tenga cuidado de asegurarse que nadie especialmente nifios puede caminar por encima de o caerse sobre la unidad de exterior Esto podr a causar lesiones personales y da os al producto No enchufe ni desenchufe el cable de alimentaci n a fin de ENCENDER APAGAR la unidad e Existe riesgo de incendio o descarga el ctrica Deseche los materiales de embalaje de forma segura Como tornillos clavos pilas piezas rotas etc tras la instalaci n 0 SVC y a continuaci n retire y deseche los pl sticos de embalaje Los ni
39. o el BOT N SELECTOR DE VELOCIDAD DEL VENTILADOR INTERIOR NOTA CAOS Air ahorra el consumo de energ a y evita el enfriamiento excesivo La velocidad del ventilador cambiar autom ticamente de alta a baja o viceversa dependiendo de la temperatura ambiente En el caso de modelo tipo Inverter que no cuentan con el BOT N CIRCULACI N DE AIRE la circulaci n podr ser activada presionando el BOT N PLASMA Funci n de re Esta funci n resulta util en situaciones de ca da de tensi n Una vez recuperada la tensi n esta caracter stica reanudar la condici n operativa anterior y el aire acondicionado funcionar bajo los mismos ajustes Esta caracter stica es activada por los ajustes por defecto de f brica pero siempre puede desactivarla presionado el bot n ON OFF durante 6 segundos La unidad emitir dos sefiales sonoras y la luz indicadora 2 parpadear 4 veces Presione de nuevo el bot n durante 6 segundos para activarla La unidad emitir dos se ales sonoras y la luz indicadora 1 parpadear 4 veces 14 Aire acondicionado Mantenimiento y servicio il Mantenimiento y servicio A ATENCI N Antes de realizar labores de mantenimiento desconecte la alimentaci n del sistema cierre el interruptor y desenchufe el cable de alimentaci n Limpie la unidad con un pafio seco y suave No utilice lej a o sustancias abrasivas A ATENCI N No utilice nunca los siguientes elementos Agua
40. odr an causar quemaduras u otros peligros para la salud No beba el agua de desag e del producto No es potable y podr a causar problemas serios de salud No bloquee la entrada o salida del flujo de aire Podr a provocar aver as en el producto No pise ni coloque nada sobre el producto Unidades de exterior Existe el riesgo de lesiones personales y aver as en el producto Tenga cuidado al desempaquetar e instalar el producto Los bordes afilados podr an causar lesiones No realice mezclas distintas a las especificadas por el refrigerante utilizado en el sistema Si el aire entrara en el sistema de refrigeraci n podr a causar una presi n excesivamente alta provocando dafios en el equipo o lesiones personales Sustituya las pilas del mando a distancia por otras nuevas del mismo tipo No mezcle pilas viejas y nuevas o de distintos tipos Existe riesgo de incendio o aver as en el producto No deje el aire acondicionado en funcionamiento durante mucho tiempo cuando la humedad sea muy alta y haya dejado abierta una puerta o ventana La humedad podr a condensarse y mojar o dafiar el mobiliario Emplee un pa o suave para limpiar la unidad No utilice detergentes fuertes disolventes etc Existe el riesgo de fuego descarga el ctrica o da os a las piezas pl sticas del producto Inserte siempre el filtro de forma segura tras su limpieza Limpie el filtro cada dos semanas o m
41. om ticamente la temperatura ambiente y el mm T volumen del flujo de aire a las mejores condiciones para la deshumidificaci n Deshumidificacion bas ndose en la temperatura ambiente actual detectada Sana En este caso sin embargo la temperatura establecida no se muestra en el mando a distancia y usted tampoco podr controlar la temperatura ambiente 1 Durante la funci n de deshumidificaci n sana el volumen del flujo de aire se establece autom ticamente seg n el algoritmo de optimizaci n que responde al estado actual de la temperatura ambiente para mantener las condiciones del cuarto sanas y confortables incluso en estaciones muy h medas M kA OX Siga los pasos 1 2 y 4 para ejecutar el modo de deshumidificaci n sana Consulte el modo de funcionamiento Funcionamiento autom A En este modo de funcionamiento el ajuste real de temperatura y la velocidad i i del ventilador se establecer n autom ticamente mediante la l gica de control electr nico bas ndose en la temperatura ambiente actual Si sintiera fr o o calor presione los botones de ajuste de temperatura a fin de lograr elevar o reducir la temperatura respectivamente NOTA No podr establecer la temperatura de ajuste actual y la velocidad del Autom tico ventilador interior en este modo de funcionamiento Aunque puede utilizar el cambio Chaos en esta operaci n Si el sistema no est funcionando seg n lo deseado cambie manualmente a
42. ombustibles cerca del producto Existe riesgo de incendio Si escucha ruidos percibe olores extra os o si su producto emite humo Cierre inmediatamente el interruptor o desconecte el cable de alimentaci n Existe riesgo de descarga el ctrica o incendio Cuando no piense utilizar el producto durante un largo per odo de tiempo desconecte el enchufe de suministro de alimentaci n o cierre el interruptor Existe riesgo de da os o aver as en el producto o funcionamiento involuntario No coloque NINGUN objeto sobre el cable de alimentacion Existe riesgo de incendio o descarga el ctrica Si existen fugas de gas inflamable apague el gas y abra una ventana para la ventilaci n del cuarto antes de volver a encender el producto No utilice el tel fono ni abra y cierre interruptores Existe riesgo de explosi n o incendio Son necesarias dos o m s personas para levantar y transportar el producto Evite lesiones personales Mantenga el nivel incluso durante la instalaci n del producto Para evitar vibraciones o ruido A ATENCI N No instale el producto donde pueda estar directamente expuesto al viento del mar salitre Podr a causar la oxidaci n del producto No instale el producto donde el ruido o el aire caliente de la unidad exterior pudieran ocasionar da os o molestar a los vecinos Podr a causar problemas y disputas con sus vecinos Instale la
43. ool y Art Cool Wide no Deluxe cierran parcialmente la descarga inferior en modo reposo para lograr un descanso agradable En modo enfriamiento o modo de deshumidificaci n sana La temperatura de ajuste aumentar autom ticamente dos veces en incrementos de 1 C durante los siguientes 30 minutos y de 2 C durante 1 hora para lograr un descanso agradable A partir de ahora sta ser la temperatura final siempre que el modo reposo permanezca en funcionamiento Manual del propietario 13 Instrucciones de funcionamiento Control de direccion El flujo de aire arriba abajo flujo de aire vertical puede ajustarse mediante el mando a distancia 1 Presione el BOT N START STOP para iniciar la unidad 2 Presione el BOT N CHAOS SWING 3 Las rejillas oscilan autom ticamente hacia arriba y abajo 4 Presione de nuevo para fijar la rejilla en el ngulo deseado R Si presiona el BOT N CHAOS SWING la direcci n horizontal del flujo de aire cambiar autom ticamente bas ndose en el algoritmo chaos para distribuir uniformemente el aire del cuarto y al mismo tiempo hacer que el cuerpo humano se sienta m s c modo como si disfrutara de una brisa natural Modo circulaci Esta operaci n hace circular el aire del cuarto sin enfriarlo ni calentarlo Puede ser activado presionando el BOTON CIRCULACION DE AIRE Una vez activada la circulaci n de aire usted podr seleccionar la m velocidad del aire presionand
44. os podr an jugar con los desechos y sufrir lesiones No utilice cables tomas o enchufes da ados De lo contrario podr a ser causa de incendio 0 descarga el ctrica No permita que el agua se introduzca en las piezas el ctricas Instale la unidad lejos de posibles fuentes de agua Existe riesgo de incendio aver a en el producto o descarga el ctrica No abra la rejilla de entrada frontal del producto durante su funcionamiento No toque el filtro electrost tico si la unidad est equipada con uno Existe riesgo de lesiones f sicas descarga el ctrica o aver as en el producto Desconecte la alimentaci n y desenchufe la unidad antes de realizar labores de limpieza o reparaci n del producto Existe riesgo de descarga el ctrica Tenga cuidado de asegurar que el cable de alimentaci n no pueda extraerse o da arse durante el funcionamiento Existe riesgo de incendio o descarga el ctrica Aseg rese de comprobar que el enchufe del cable de alimentaci n no est sucio flojo o roto y s lo entonces inserte el enchufe en la toma de pared Un enchufe sucio flojo o roto puede ser causa de descarga el ctrica o incendio No toque opere o repare el producto con las manos h medas Sujete el enchufe firmemente con la mano antes de tirar para extraerlo Existe riesgo de descarga el ctrica o incendio No almacene ni utilice ni tan siquiera permita la presencia de gases inflamables o c
45. product Be cautious when unpacking and installing the product Sharp edges could cause injury Do not mix air or gas other than the specified refrigerant used in the system f air enters the refrigerant system an excessively high pressure results causing equipment damage or injury Replace the all batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of batteries There is risk of fire or product failure Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open Moisture may condense and wet or damage furniture Use a soft cloth to clean Do not use harsh detergents solvents or splashing water etc There is risk of fire electric shock or damage to the plastic parts of the product Always insert the filter securely after cleaning Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficiency If the refrigerant gas leaks during the repair do not touch the leakaing refrigerant gas The refrigernat gas can cause frostbite cold burn If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Do not recharge or disassemble the batteries Do not dispose off batteries in a fire They may burn or explode Do not expose your skin or kids or plants
46. r After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward Deodorizer filter Plasma filter A CAUTION Don t touch this plasma filter within 10 seconds after opening the inlet grille it may cause an electric shock Owner s Manual 15 Maintenance and Service A CAUTION Don t touch this plasma filter within 10 seconds after opening the inlet grille it may cause an electric shock it Outdoor Uni HS The heat exchanger coils and panel vents of the outdoor unit should be checked regularly If clogged with dirt or soot the heat exchanger and panel vents may be professionally steam cleaned NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs Operation Ti Do not overcool the room Keep blinds or curtains Keep the room temperature closed uniform This is not good for the health and Do not let direct sunshine enter Adjust the vertical and horizontal wastes electricity the room when the air conditioner airflow direction to ensure a is in operation uniform temperature in the room Make sure that the Clean the air filter Ventilate the room Use high fan speed doors and windows regularly occasionally for effective and fast are shut thight cooling Avoid opening doors and Blockages in the air filter Since windows are kept The unit gives its rated windows as much as reduce the airflow and closed itis a
47. ra el funcionamiento de la calefacci n Los modelos Art Cool y Art Cool Wide cierran las descargas laterales durante el funcionamiento del chorro de aire fr o caliente a fin de lograr un enfriamiento calefacci n m s fuerte y eficaz Funcionamiento EI filtro de plasma es una tecnologia desarrollada por LG a fin de lograr eliminar los Iri contaminantes microsc picos presentes en el aire de entrada mediante la Lic generaci n de un plasma con electrones de altas cargas sull Este plasma elimina y destroza completamente los contaminantes para proporcionar un aire limpio e higi nico La purificaci n por plasma puede iniciarse presionando el BOT N PLASMA en el mano a distancia Volver a presionarlo cancelar su ejecuci n NOTA Esta caracter stica puede emplearse en cualquier modo de funcionamiento y a cualquier velocidad del ventilador 12 Aire acondicionado Instrucciones de funcionamiento Procedimientos pare el funcionamiento cuando no se puede utilizar el control remoto La unidad se pone en marcha cuando se pulsa este bot n Si desea pararla pulse el bot n de nuevo ON OFF button Modelo de Modelo de bomba de calor enfriamiento Temperatura de la habitaci n gt 24 C 21 C lt temp habit 24 C Temperatura de la habitaci n lt 21 C Modo de funcionamiento Enfriamiento Enfriamiento Deshumidificaci n saludable Calentamiento Velocidad de VENTILADOR interior Alta Selec
48. rming any maintenance turn off the main power to the system disconnect the circuit breaker and unplug the power cord Indoor Clean the unit with a soft dry cloth Do not use bleach or abrasives 44 CAUTION Never use any of these Water hotter than 40 C It may cause deformation and discoloration Volatile substances They may damage the surface of the air conditioner Air Filters The air filters behind the front panel grill should be checked and cleaned once in every 2 weeks or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Plasma Filters The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodorizer Filters Remove the deodorizer filters behind the air filter and expose them in direct sunlight for 2 hours And then insert these filters into original position Removal of Filters Open the front panel as shown Then pull the filter tab slightly forward to remove the air filte
49. ta del filtro a fin de desmontar el filtro de aire Tras desmontar el filtro de aire retire el filtro de plasma y el desodorante extray ndolo levemente hacia delante A ATENCI N No toque el filtro plasma en los 10 segundos siguientes a la apertura de la rejilla de entrada podr a causar descargas el ctricas Manual del propietario 15 Mantenimiento y servicio A ATENCI N No toque el filtro plasma en los 10 segundos siguientes a la apertura de la rejilla de entrada podr a causar descargas el ctricas Debe revisar habitualmente las bobinas del intercambiador de calor y los orificios del panel de la unidad exterior Si est n obstruidos con suciedad u holl n el intercambiador de calor y los orificios del panel pueden limpiarse profesionalmente con vapor NOTA Tener las bobinas sucias u obstruidas reduce la eficacia de funcionamiento del sistema y causa importantes gastos de funcionamiento No enfr e demasiado el Mantenga cerradas cortinas Mantenga uniforme la habit culo y persianas temperatura del habit culo Esto no es sano para su salud y No permita que la luz directa del Ajuste la direcci n del flujo de adem s representa un derroche sol entre en el habit culo mientras aire vertical y horizontal para de electricidad el aire acondicionado se asegurar una temperatura encuentre en funcionamiento uniforme en todo el habit culo Aseg rese que las Limpie el filtro de aire Ventile el habit culo Configure e
50. unit the step up capacitor supplies high voltage electricity to the electrical components Be sure to discharge the capacitor completely before conducting the repair work An charged capacitor can cause electrical Shock A WARNING Do not use a defective or underrated circuit breaker Use the correctly rated breaker and fuse There is risk of fire or electric shock Always ground the product as per the wiring diagram Do not connect the ground wire to gas or water pipes lightening rod or telephone ground wire There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock Never install the outdoor unit on a moving base or a place from where it can fall down The falling outdoor unit can cause damage or injury or even death of a person When installing the unit use the installation kit provided with the product Otherwise the unit may fall and cause severe injury Do not use a multi consent Always use this appliance on a dedicated cicuit and breaker Otherwise it can cause electric shock or fire Install the panel and the cover of control box securely There is risk of fire or electric shock due to dust water etc For installation removal or reinstall always contact the dealer or an Authorized Service Center
51. use of an extension cord due to potential safety hazards A WARNING This appliance should be installed in accordance with national wiring regulations This guide acts as a guide to help to explain product features This symbol alerts you to the risk of electric shock air conditioner This symbol alerts you to hazards that may cause harm to the egi zl This symbol indicates special notes 6 Room Air Conditioner Product Introduction B Product Introduction Here is a brief introduction of the indoor and outdoor units Please see the information specific to your indoor unit type Indoor Units Standard Split Type Display panel LED indicators Airinier Plasma filter Optional Front grille ON OFF button Air filter Air outlet Vertical blades receiver Flap Horizontal blade D On Off Lights up during the system operation error code and auto restart setting SX Sleep mode Lights up during sleep mode auto operation non Inverter Model gag Plasma The function illustrates its dynamic mode by using a multiple lighting system Defrost mode Lights up during defrost mode or hot start operation Heat pump model only OUT Outdoor unit Lights up during outdoor unit operation Cooling model only DOOR BB Power Display Indicates the setting temperature and operation mode Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out