DevCom2000 User Manual
Contents
1. English Z DevCom2000 is restarted 7 Don t Connect to Device On Startup Ok Cancel Restore Defaults 3 Click either Device DD or Generic DD depending on which DD is to be loaded when connecting to a device 4 Check the Don t Connect to Device On Startup to start DevCom2000 without connecting to a device Clicking New Device will connect to a device after this start up Click OK to save the changed settings Click Yes if you want to save the changes Clicking no will not save the changes DevCom2000 Are you sure you want to save the changes you made to your preferences No 7 Restart DevCom2000 for the changes to take place 8 If Don t Connect to Device On Startup is checked the following message will be displayed on start up MAN 1010 05 01 2014 Our Quality Management System is Page 54 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action DevCom2000 a Not Connecting to Device Click New Device to connect 6 12 4 4 Default Settings The Default button on the Advanced tab Options resets all the advanced options to their default settings To return the settings to their default settings perform the following steps Step Action l Ensure that the application is running DevCom2000 Explorer et a Device Options View Enhanced Trending DD License Wi
2. Expand the menu by clicking the sign and double click to view the device parameters 2 Select the menu where the method is present and double click to execute it 3 Below is an example of a Method dialog box MAN 1010 05 01 2014 Our Quality Management System is Page 28 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action A DevCeen2000 Explores Tag P10 longtagiDesc TEST UNIT Device 3051 DO OLONO unam hodan NM Click Set to open a Method dialog box Send warning Variables which use this as the units code will be in the previous units until this value is sent to the device Press OK button to continue method execution or Abort button to abort method execution 4 Click OK to move to the next dialog in the Method sequence Or click Abort to cancel the Method execution 6 Click Help to get specific help for that step of the Method This Help information is provided by the device DD 6 4 Calibrating HART Field Devices Calibration of field devices and loop test are achieved by executing the Methods or Standard Operating Procedures that are specific to device Methods are defined based on the test parameters specific to the device providing information for the calibration of that device See the previous section for Method execution MAN 1010 05 01 2014 Our Quality Management System is Page 29 ISO 9001 2008 Certified A PROCOMSOL
3. DevCom2000 is restarted Don t Connectto Device On Startup Cancel Restore Defaults 3 Under the section HART Master select either Primary or Secondary 4 Click OK to save the changed settings Click Yes if you want to save the changes Clicking no will not save the changes DevCom2000 Are you sure you want to save the changes you made to your preferences 6 Restart DevCom2000 for the changes to take place 6 12 4 2 Language Certain DD s can be used in different languages English is the default setting but some support other languages Note that main program frame will always be English Only the DD based items menus variables etc will change language And will only change if the DD supports that language In order to change the Language setting perform the following steps Step Action 1 Ensure that the application is running MAN 1010 05 01 2014 Our Quality Management System is Page 51 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manual Step Action A DevCom2000 Explorer E s a Device Options View Enhanced Trending DD License Window Help a x RiP S Qa a Online Item Value Units Overview Device Status Good Configure Comm Status Burst Service Tools f Pressure 2 1 inH20 Analog Output 11 331 mA upper Range
4. MAN 1010 05 01 2014 Our Quality Management System is Page 47 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action DevCom2000 Are you sure you want to save the changes you made to your preferences No 6 Reconnect to a new device 6 12 3 2 Short Tag The Search menu can also be used to search by a specific Tag name or Description To search for a device based on a Tag name or a Description perform the following steps Step Action 1 Ensure that the application is running DevCom2000 Explorer la Device Options View Enhanced Trending DD License Window Help e x 81 3 5 3 Online Item Value Units a a Overview Device Status Good Configure Comm Status Burst G Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA upper Range valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 Device Information m Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 2 Select Options gt Search from the main window The Options Dialog Box is displayed with the Search By tab selected MAN 1010 05 01 2014 Our Quality Management System is Page 48 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Options Basic Search By Advanced Se
5. ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions Step Action DevCom2000 User Manual Enter Location of File DD Info Device Label Manufacturer No Device No Device Rev DD Rev Type Add DD Update Label Close 4 Click Browse and go to the location of the DD that is to have the label updated 5 The DD Info section will be populated Confirm that it is the correct DD Below is an example of 0000c2 0021 0201 fm6 DD Info Manufacturer No O000c2 Device No 0021 Device Rev 02 DD Rev 0 Type fmb6 6 Input a Label for the DD if necessary Click Update Label to update the label 7 Below is the new Available DDs sections where 000013 0002 is given the label Updated Label B 43 DD Library MAN 1010 05 01 2014 a eal E PERA DODO 2 Standard 000 C Ametek 0x03 3 Brooks Instrument 0x04 4 Daniel Industries Ox0D 4 Endress amp Hauser 0x11 C ABB 0x12 isher Controls 0x13 Position gt lt mitter 0x00 CI Updated Label 0x02 4 D YC6000 0x03 4 0 04 4 D C2000 0x05 0x07 Foxboro 014 Fuji 0x15 ABB 0x16 Honeywell 0x17 7 D 2 B 8 8 a Ej Our Quality Management System is ISO 9001 2008 Certified xl Page 69 Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual 6 15 HART IP Communication Step Action 1 Ensure that se
6. Process Communications Solutions DevCom2000 User Manual 6 5 Viewing the Device Status DevCom2000 provides the user with the ability to monitor the device specific status of the device and the communication network When there is error communicating with the device it is recognized and indicated to the user The user can view more details of such errors using the View gt Device Condition from the main window To view the device and communication status perform the following steps Step Action 1 Ensure that the application is running and communications have been established 2 DevCom2000 Explorer i Device Options View Enhanced Trending DD License Window Help e x lalese 5 6 Online Item Value Units a a EN Device Status Good Configure 2 Comm Status Burst amp Service Tools amp Pressure 21inH20 Analog Output 11 331 mA upper Range valu 40 0 inH20 Lower Range Value 4 ma 30 0 inH20 4 Device Information Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM Expand the menu by clicking the sign and double click to view the device parameters 3 Select View gt Device Condition from the main window or choose the status icon amp from the toolbar Following window is displayed MAN 1010 05 01 2014 Our Quality Management System is Page 30 ISO 9001 2008 Certified Y PROCOMSOL Proc
7. Communications Solutions DevCom2000 User Manu al Options Basic Search By Advanced Modem Server Preferences SerialPort COM40 available Online DevCom2000 Use TCP IP with WirelessHART Gateway IP Address 192 168 1 1 Advanced Settings Port 5094 7 Use HART Server with WirelessHART Gateway or HART Multiplexer Note HART Server must be purchased from the HART Foundation Restore Defaults 3 You may also change the polling options for the computer If you do not know the poll address of the device you are trying to communicate with use the default address 0 setting To do this either click on the Search By tab or go to Options gt Search Options Basic Search By Advanced Search By Poll Address v Search by Tag Search by Poll Address WirelessHART Adapter Default use poll address 0 only C ABB FieldKey 15 find first poll addres saana a M Emerson THUM 63 M use poll address 63 gt Endress Hauser SWA 0 15 search 0 15 MACTek BULLET 15 search 0 31 C Pepperl Fuchs WHA ADP 15 search 0 63 oa Phoenix Contact RAD WHA 63 search range 0 through C Siemens SITRANS AW200 15 Restore Defaults Make sure that Poll Address under Search By is selected MAN 1010 05 01 2014 Our Quality Management System is Page 15 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual 4 When the dev
8. Event Status Log menu option or click on the E icon to go back to the original window 6 8 Saving Device Configuration to Disk HART Device configurations can be saved to disk as a text file to document the device Fields are delimited with a comma so that the data can be imported into configuration management software packages A PDF version of the configuration is also created To save device configurations to disk perform the following steps Step Action Ensure that the application is running and communications have been established DevCom2000 Explorer E Device Options View Enhanced Trending DD License Window Help ai x ai ej ae G3 Online Item Value Units ERS Overview Kd Device Status Good H Configure 2 Comm Status Burst Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA 2 upper Range Valu 40 0 inH20 30 0 inH20 Lower Range Value 4 mA 1 Device Information m 4 Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM Tag P 101 LongTag Desc TEST UNIT MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Page 34 A PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action 2 Select Device gt Document Device from the main window The Document Device Dialog Box is displayed Document Device File Name C ProgramFiles ProComSofDevCom200
9. HCF DDL Library xxxxxx yyyy where XXXXxXx represents the manufacturer ID and yyyy represents the device ID The user does not need to add the directory structure DevCom2000 does that automatically To add a DD perform the following steps Step Action 1 Ensure that the application is running you do not have to be connected to a device to use Add DD A DevCom2000 fexploeer o Device Optons View Entancec Trending OO Lxense Window Help ex 2 250 8 ERROR Failed to acquire a Gevice identity HART Acowt Trend Activit 2 Select DD gt Add DD from the main window The Add DD dialog will open MAN 1010 05 01 2014 Our Quality Management System is Page 66 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Enter Location of File DD Info Device Label Manufacturer No Device No Device Rev DD Rev Type i Add DD Update Label Close 4 Click Browse and go to the location of the DD that is to be added The DD Info section will be populated Confirm that it is the correct DD Below is an example of 0000c2 0021 0201 fm6 DD Info Manufacturer No O000c2 Device No 0021 Device Rev 02 DD Rev 01 Type fm amp 6 Input a Label for the DD if necessary If not Click Add DD to add the DD to the library 6 14 2 Updating a DD Label DevCom2000 all
10. Page 26 y PROGOMSOL Process Communications Solutions DevCom2000 User Manual Step Action 5 6 Make the change to the value as required Click Set to accept the changes Or press Cancel to cancel the changes Click OK to close the dialog box Device Options View Enhanced Trending DD DTM Window Help mi P 2 ia Online tem vue Puts QJ Device setup 09 Process variables H Diag Service 0 Basic setup B Detailed setup H Sensors 3 Signal condition QJ Output condition 29 Analog output 20 HART output J Meter Options 5 0 Device information E Revision s E Status 0 Review lol x l lxi Tag TestDev LongTag Desc Dev Desc Here Device 3144 Temp DD 26 HART Activity Trace Activity Again the yellow means the parameter is changed and ready to be sent to the device Click on the Send icon to commit the changes to the device Device Options View Enhanced Trending DD DTM Window Help 10 x ieixi lal el aQale Online Device setup Device setup E n aar 00 Process variables K2 Pe 0 00 degC H Diag Service a Pv AO 0 00 m 23 Basic setup hd PY LRY 0 00 degC 5 Detailed setup A PvURY 10 00 degC 29 Sensors 9 Signal condition Output condition 9 Analog output 9 HART output J Meter Options 5 0 Device information Q Revision s E Status D Review Tag TESTDEV LongTag Desc DEV DESC HERE Device 3144 Temp DE H
11. Review Tag TestDev LongTag Desc Dev Desc Here Device 3144 Temp DD 26 HART Activity Trace Activity Double click the parameter you wish to edit The following dialog box appears on the screen Devcom2000 Online lol x C Device Options View Enhanced Trending DD DTM Window Help lj xj 12 3 Bib Online tem vue furits S 5 Device setup Devire sehun 09 Process variable PgR Sag te ayers EV Vxj o 00 deac Diag Service 0 00 m Basic setup Edit Display 5 5 Detailed setup item il 00 degC 9 Sensors 0 00 degC Signal condi 0 00 degC B Output con 9 Analog E HART o Q Meter 5 Device infor 0 Revisior 9 Status 9 Review Tag TestDev LongTag Desc Dev Desc Here Device 3144 Temp DD 26 HART Activity Trace Activity eal Double click the parameter you wish to edit The following dialog box appears on the screen iojxi Z Device Options View Enhanced Trending DD DTM Window Help la x A2 8 2 b B EE erie tem tue units B Device setup a 0 00 degC k 0 00 m ptt rite As One Ea 0 00 dege 0 00 degC S Detailec Edit Display T00 C ce Tag TestDev LongTag Desc Dev Desc Here Device 3144 Temp DD 26 HART Activity Trace Activity MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified DevCom2000 User Manual
12. Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al Problem Active Windows not shown in Windows drop down list Try the following 1 Select Window gt Cascade or Window gt Tile 2 All Windows will now be shown Problem When using HART Server for WirelessHART in Windows 7 the device selection screen does not appear Try the following 1 Start Windows Explorer 2 Go to directory C Program Files ProComSol Common 3 Run RegisterSELECT bat as an Administrator MAN 1010 05 01 2014 Our Quality Management System is Page 75 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al Appendix B Contact Information ProComSol Ltd Process Communications Solutions 13001 Athens Ave Suite 220 Lakewood OH 44107 USA Phone 216 221 1550 Fax 216 221 1554 Email sales procomsol com support procomsol com Web www procomsol com MAN 1010 05 01 2014 Our Quality Management System is Page 76 ISO 9001 2008 Certified
13. be Checked Out by other users This enables the license to be shared by many users 6 11 1 Check In To Check In the license from the current computer to the License Server perform the following steps Step Action 1 Verify your PC is connected to the Internet 2 Select Check In from the License Menu If the current computer is not licensed an error message will appear If licensed the program will contact the License Server via the internet It will check in the license using the License ID and Password used in Activation The current computer will MAN 1010 05 01 2014 Our Quality Management System is Page 39 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action then become un activated 6 12 Options Menu 6 12 1 Options gt Basic 6 12 1 1 Changing the COM port The Basic menu is used to set the COM port to the correct one that the device is connected to To change the COM port perform the following steps Step Action 1 Ensure that the application is running 4 DevCom2000 Explorer So Device Options View Enhanced Trending DD License Window Help a x a 3a 5 8 Online Item Value Units a a Overview Device Status Good M Configure 2 Comm Status Burst Service Tools Pressure 2 1 inH20 f Analog Output 11 331 mA upper Range valu 40 0 inH20 Lower Range Value 4 ma 30 0 inH2
14. for you use a USB to HART modem ProComSol Ltd model HM USB ISO if you do not have an RS232 port Step 3 Connect to the field device Find a connection point for the device s 2 wire 4 20mA loop you wish to communicate with For communications you must have a suitable load resistance or a 250Q resistor must be placed in series with the device Using the clips from the HART interface connect to the HART device While the HART Communication signal is available anywhere along the 4 20mA wiring it is often easiest to connect across the field device s terminals caution should be observed when working in a hazardous area many PC s are not rated for intrinsic safety and should only be connected in a safe area Step 4 Activate DevCom2000 Launch DevCom2000 by selecting the DevCom2000 icon on your desktop You can also start the application by going to your computer s Start Menu and selecting Start gt Programs gt ProComSol gt DevCom2000 gt DevCom2000 to launch the program You will now be asked to Activate DevCom2000 If you have Activation Codes located on the CD case select the Activation method of your choice Manual or Online Select the Evaluate option if you do not have Activation Codes You can use DevCom2000 for 10 days before you need to Activate it If you are Activating DevCom2000 by the online method select online activation You will be asked to enter the Activation Codes on the next screen Once entered DevCom2000 will
15. is not required for HART IP communications to a WirelessHART Gateway In this case an Ethernet connection is required MAN 1010 05 01 2014 Our Quality Management System is Page 7 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al 3 SYSTEM REQUIREMENTS The following minimum system requirements are recommended for operation of DevCom2000 PC Processor Speed Pentium 600 Mhz Memory 256 MB Hard Disk Space 500 MB Monitor 256 color VGA HART Modem USB to HART modem or Bluetooth to HART modem or RS 232 to HART modem ProComSol Ltd supplies HART modems Not needed for HART IP Communication Port USB Bluetooth or RS 232 Ethernet for HART IP Operating System Windows XP Windows Vista Windows 7 Windows 8 MAN 1010 05 01 2014 Our Quality Management System is Page 8 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al 4 DEVCOM2000 INSTALLATION 4 1 Prerequisites You need to be familiar with the basic functions of the following when installing the DevCom2000 tool e Microsoft Windows e HART communication interface e HART field device 4 2 Installing the DevCom2000 Application To install the DevCom2000 application in a standalone system perform the following steps Step Action 1 Insert the DevCom2000 CD into the CD ROM drive Auto run should begin installation if not 2 Click Start and choose Run From
16. of the connected device perform the following steps Step Action 1 Ensure that the application is running and communications have been established A DevCoen2000 JExplorer 3 Device oan manced trending OO License Window Help a Sow z Ja e 1D upper Range vate 20 0 an0 1D Lower kange vaiue 4 ma 220 eNO LD Dew mat Tag P10 LengTag Dese TEST UNIT Device 3051 OO 26 06 03 07 HART Actes Teens Activin Nu Expand the menu by clicking the sign and double click to view the device parameters 2 Select the menu where the editable parameter is present as shown below NY DevGorn2000 Explorer Device Options View Enhanced Trending DD License Window Help a e ba E BH Online a nem Value Units D Overview 12 Pressure Units into Device Information 12 Damping 0 00 sec F Transfer Function Unear I Semsor Temperature Units degC 1 i Guided Setup Basic Setup Configure Display Manual Setup a Analog Output Display HART Security Device information Kentification Flange i Tag P 101 longt DeC TEST UNIT Device 3051 DO 26 06 03 07 HART Activit Trend Activit NUM 3 Double click the variable to edit it The following dialog box appears on the screen MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified DevCom2000 User Manual Page 23 Ay PROGOMSOL Process Communications Solutions DevCom2000 User Manual St
17. perform the following a Open the hosts file using Notepad Itis located in the following directory C WINDOWS system32 drivers etc hosts b Make sure this line appears without preceding character 127 0 0 1 localhost c Make sure the following line does NOT appear 1 localhost If it is there comment it out by placing character in front like this 1 localhost d Restart the Communication logger Note To modify this file you may need to perform the following in Windows a Go to Control Panel gt Folder Options b Select the View tab c Remove the check next to Hide extensions for known file types d Make the edit changes above e Save the document to your documents f copy the saved document to the above directory g Delete the original hosts file h remove the txt extension from the new hosts file 3 Turn off firewall protection temporarily to see if it is blocking the TCP IP communications between DevCom2000 and the Communication Logger Problem The system cannot find the path specified error box Try the following 1 Verify that the device library C HCF DDL Library is on Drive C 2 If not copy to drive C Problem Activation by Internet blocked by Firewall Try the following 1 Allow one time access to internet via your computer s Firewall settings 2 Disable Firewall 3 Use manual activation method MAN 1010 05 01 2014 Our Quality Management System is Page 74 ISO 9001 2008 Certified
18. text file where the data has been saved Delete Deletes a previous trend from the database Close Closes the dialog box Trend Opens the saved Trend and displays it graphically Select a trend to graph and click Trend 4 The DevCom2000 Trend dialog opens up when Trend is selected gt iW e QQ Ck SESR 13 30 00 13 40 00 13 50 00 14 00 00 14 10 00 14 20 00 Pressure inH20 I Graph 3 I Graph 2 Graph 4 ReDraw The user can manipulate the graph as desired Tracking is the term used to describe how the graph control follows the data MAN 1010 05 01 2014 Our Quality Management System is Page 62 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action changing the axis in real time so that all of the data is shown Below are the specific parts of the graph Tool Bar There are multiple things that the user can do with the graph gt i ite QQ OD Ba ted a Resume All Tracking The Resume All button A is grayed out while tracking If either axis is changed or the Pause button is pressed this will be come green a Pressing Resume All Tracking will resume the tracking on the graph Pause All Tracking The Pause button i pauses the graph in its current state Data is still added however the current X axis and Y axis spans no longer change Pressing the Resume but
19. the Run window click Browse In the Look In box browse to your CD drive 4 Double click the drive to access the CD content Look for the DevCom2000Setup exe file and double click the same This process will take you through a sequence of installation wizard steps 6 Follow the instructions on the upcoming screens to complete the Installation 43 Activating DevCom2000 DevCom2000 must be activated before use If the program is not activated it will not run after 10 days The following procedure will activate the software MAN 1010 05 01 2014 Our Quality Management System is Page 9 ISO 9001 2008 Certified Na PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action 1 Start the DevCom2000 Application The following Activation window is displayed xi DevCom2000 Purchase DevCom2000 Online Open my browser to the online ordering page Activate DevCom2000 have already purchased and would like to activate the product Evaluate DevCom2000 You have 10 days left in your evaluation period Go To Website Exit If you want to evaluate DevCom2000 before purchasing select the Evaluate DevCom2000 option You will have 10 days of unlimited program use before you will need to purchase a license Select Purchase DevCom2000 Online to go to the ProComSol Ltd website to purchase a license 2 If Activate DevCom2000 is selected the following window appears M
20. valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 5 Device Information u i gt Tag P 101_ LongTag Desc TEST UNIT _ Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 2 Select Options gt Advanced from the main window The Options Dialog Box is displayed with the Advanced tab selected Options Basic SearchBy Advenced HART Master OD Startup Primary Device DD C Secondary C Genenc DO Select Language Change in language will not take effect until English Z Devcom2000 is restarted Don t Connect to Device On Startup Restore Defaults 3 Click the Select Language drop down to select a different language Select Language Engin z Change in language will not take effect until DevCom2000 is restarted English French Italian Japanese Spanish On Startup MAN 1010 05 01 2014 Our Quality Management System is Page 52 ISO 9001 2008 Certified A PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action 4 Select a language to translate the DD into Click Okay to save the changed settings 5 Click Yes if you want to save the changes Clicking no will not save the changes DevCom2000 Are you sure you want to save the changes you made to your preferences No 6 Restart DevCom2000 for the changes to take place If the language is supported the DD will be translated If
21. 0 Are you sure you want to save the changes you made to your preferences 8 Restart DevCom2000 for the changes to take place 6 13 Trending 6 13 1 Define Trend The Trending menu is used to track dynamic device parameters over a specified period of time Once a parameter is tracked it can be graphed and compared against other parameters tracked on the same time period Before a parameter can be graphed a trend must first be created To create a trend perform the following steps MAN 1010 05 01 2014 Our Quality Management System is Page 56 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action 1 Ensure that the application is running and is connected to a device A DevCom2000 Explorer t Device Options View Enhanced Trending DD License Window Help E Ex KARRAR A 5 Online Item Value Units ERS Overview Device Status Good Configure 2 Comm Status Burst E Service Tools N Pressure 2 1 inH20 a Analog Output 11 331 mA D upper Range valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 2 Device Information lt m j r Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM j 2 Select Trending gt Define Trend from the main window The Define Trend Dialog Box is displayed Define Trend Select parameter s Maxamum 4 use CNT
22. 0 3 Device Information it r LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM Tag P 101 2 Select Options gt Basic from the main window The Options Dialog Box is displayed with the Basic tab selected MAN 1010 05 01 2014 Our Quality Management System is Page 40 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Options Basic Search By Advanced Modem Server Preferences Serial Port COM40 v available Online DevCom2000 Use TCP IP with WirelessHART Gateway IPAddress 192 168 1 2 11 Advanced Settings Port 5094 Use HART Server with WirelessHART Gateway or HART Multiplexer Note HART Server must be purchased from the HART Foundation Cancel Restore Defaults 3 To change serial ports Click on the drop down box SerialPort COMS51 fi COM49 a line DevCom200 COM50 COM52 x Use with WirelessHART Gateway or HART Mult 4 Once the desired COM port is selected click OK to save the changed settings 5 Click Yes if you want to save the changes Clicking No will not save the changes DevCom2000 Are you sure you want to save the changes you made to your preferences No 6 Select New Device from the Main screen to connect using the new COM port MAN 1010 05 01 2014 Our Quality Management Sy
23. 0 TESTDEV_1_ tet Notes Notes must be less than 250 characters Save Device Contig POF Setup 3 The default directory is based on Windows User Accounts The default file name is Tag_Device ID The directory and filename can be changed by the user Use the Browse button to change directories and or filenames also 4 Enter a Note in the Notes field if desired Maximum of 250 characters Press the Save Device Config button to save device configuration 6 If the filename has already been used the following Dialog Box is displayed when Save Device Config is pressed File Exists f xj File Exists Please choose from below C Append 12 C Overwrite C Cancel Append Adds the number shown to the end of the file name Overwrite Deletes and writes over the existing file Cancel Returns to the previous menu MAN 1010 05 01 2014 Our Quality Management System is Page 35 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual 6 9 Download Configuration to Device Saved configuration files can be downloaded back to devices This is useful for Cloning a device either for replacement or plant setup To save device configurations to disk perform the following steps Step Action 1 Ensure that the application is running and communications have been established A4 DevCom2000 Explorer oS a Devic
24. 00 Are you sure you want to save the changes you made to your gt preferences 7 Reconnect to a new device 6 12 4 Options gt Advanced 6 12 4 1 HART Master The Advanced menu is used to change DevCom2000 settings DevCom2000 can be a Primary or Secondary HART Master To change the HART Master setting perform the following steps Step Action l Ensure that the application is running mo DevCom2000 Explorer o baa m Device Options View Enhanced Trending DD License Window Help s x A 3a Online Item Value Units SRS Overview Device Status Good Configure 2 Comm Status Burst Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA upper Range Valu 40 0 inH20 Lower Range Value 4 ma 30 0 inH20 Device Information lt nL Tag P 101 _ LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM A 2 Select Options gt Advanced from the main window The Options Dialog Box is displayed with the Advanced tab selected Our Quality Management System is MAN 1010 05 01 2014 ISO 9001 2008 Certified Page 50 Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Options Basic Search By Advanced HART Master DD Startup Primary Device DD Secondary Generic DD Select Language Engin x Change in language will nottake effect until E
25. 078 86636908 Activation Code 1 Activation Code 2 ee ae Click here for support Back Exit Continue m You will then need to contact ProComSol Ltd to obtain the Activation Codes You must supply the User Codes to ProComSol Ltd support personnel Your user codes will be different than those shown here You can register manually in any of the following ways 1 Call ProComSol Ltd at 216 221 1550 Have the program License ID and User Codes ready 2 Or send an email to support procomsol com containing your company name License ID and User Codes 3 Or send a fax to ProComSol Ltd 216 221 1554 containing your company name License ID and User Codes The above information will be processed at ProComSol Ltd and an appropriate response will contain the required Activation Code information that the user will need to enter If successful the program continues as normal You will not need to perform the activation process again 5 We have tried to make the Activation process as easy as possible Contact ProComSol Ltd if you have any difficulties MAN 1010 05 01 2014 Our Quality Management System is Page 12 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manu al 4 4 Connecting to the HART Network The DevCom2000 application communicates with the HART Field Devices through a HART compatible communication interface e g a HART Modem Using this communication interf
26. 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action 44 DevCom2000 Explorer Le a Device Options View Enhanced Trending DD License Window Help ex Agl M 5 Online Item Value Units Overview Device Status Good Configure Comm Status Burst G3 Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA upper Range Valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 E Device Information lt i m r Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM j Expand the menu by clicking the sign and double click to view the device parameters 2 Select View gt Communication Log from the main window or choose the communications log icon from the toolbar Following window is displayed ie Communication Log A File Edit View Window Help De A Serial j Data Stream Note The communications log lists actual HART commands and the responses from the unit A good understanding of the HART protocol is required to interpret this data 3 Select File gt Exit to get back to the main window Or close the Communication Log window by clicking on the X MAN 1010 05 01 2014 Our Quality Management System is Page 32 ISO 9001 2008 Certified XN PROCOMSOL Process Communications Solutions DevCom2000 User Manual 6 7 Viewing the Event Sta
27. AN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Page 10 Ay PROGOMSOL Process Communications Solutions DevCom2000 User Manual Bi vevcomzooo activation S DevCom2000 Activating DevCom2000 is simple and quick Please select an activation option Activate DevCom2000 Online have a valid License ID Activate Manually will contact a support representative Click here for support Back 3 Exit 3 If the Activate DevCom2000 Online option is selected the following window appears x DevCom2000 Please enter your License ID and Password found on the CD Label or received through your email Please enter your License ID Where is my License ID Please enter your Password Ao Click here for support Back gt 4 Exit Continue m Enter the information from the Activation label on the CD case Select Continue to process the information If the codes were successfully entered the program will continue as normal You will not need to perform the activation process again MAN 1010 05 01 2014 Our Quality Management System is Page 11 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual 4 If the Activate Manually option is selected the following window appears MB DevCom2000 Activation J x DevCom2000 Activation Please call 216 221 1550 to activate DevCom2000 User Code 1 User Code 2 295962
28. ART Activity Trace Activity ld 7 After being sent the change is reflected in the device info 6 3 4 Executing Methods or Standard Operating Procedures Methods are defined in the DD file for the device that DevCom2000 is connected to You can select the Method and execute it for calibrating the device trouble shooting etc Method execution leads you through a number of steps like in a wizard MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Page 27 Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual A Few examples of methods include Setting high and low range calibration points Calibration of the device Run the advanced diagnostic test procedure Execute tests to gather information on device operation To execute a Method perform the following steps Step Action 1 Ensure that the application is running and communications have been established DevCom2000 Explorer be W Device Options View Enhanced Trending DD License Window Help azale Online Item Value Units ERS Overview Device Status Good 2 Configure 2 Comm Status Burst Service Tools Pressure Analog Output upper Range valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 2 Device Information lt m Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM
29. Cancel Restore Defaults MAN 1010 05 01 2014 Our Quality Management System is Page 42 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action 3 Click Use TCP IP with Wireless HART Gateway Options Basic Search By Advanced Modem Server Preferences Serial Port COM40 7 available Online DevCom2000 v Use TCP IP with WirelessHART Gateway IP Address 192 168 1 Advanced Settings Port 5094 Use HART Server with WirelessHART Gateway or HART Multiplexer Note HART Server must be purchased from the HART Foundation Cancel Restore Defaults The Serial Port option will now be grayed out Un checking will make Serial Port selectable again 4 Enter the IP Address of the WirelessHART Gateway in the IP Address Field Also enter the Port assigned to HART IP in the Gateway Itis typically 5094 5 For more advanced settings related to HART IP click the Advanced button The following dialog box appears Advanced HART IP Setup Gateway Addressing Gateway URL Resolve Enter Gateway URL as text then press Resolve to find IP Address Gateway HART Address 0 Communicating to a WirelessHART Gateway via its URL MAN 1010 05 01 2014 Our Quality Management System is Page 43 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Ma
30. LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HARTActint Trend Activit NUM 6 Click on the Send icon to commit the changes to the device 7 When the value is no longer yellow the variable has been changed in the device MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Page 24 Y PROCOMSOL Process Communications Solutions Step Action DevCom2000 User Manual DevCom2000 Explorer Sal Device Options View Enhanced Trending DD License Window Help ojx td e 08B Ontine a Item Value Units Overview 2 Pressure Unas ent20 1B Device Information 2 Damping 0 00 sec Configure 12 transfer Function Linear Guided Setup ND Sensor Temperature Units deur Basic Setup tea Configure Display Manual Setup S Process Variables Analog Output Display Service Tools O Alerts Variables Trends Maintenance Aa Simdata Tag P 101 LongTag Dese TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM The Send and Cancel Icon will now be grey as well This indicates that there are no new changes to be sent to the device 6 3 3 Edit Display The Edit Display is a variation on the Variable edit An additional window helps the user view a group of parameters based on the DD You can also modify a single parameter from this group Parameters linked to the edited field will be updated automatically To view and
31. Process Communications Solutions DevCom2000 User Manual Step Action Device Opoom View Enhanced Trending DD License Window Heip x 295298 oR te Value Units The left pane of the window shows the menu structure and the right pane of the window displays corresponding parameters of the menu selected The menus are displayed depending on the type of device that is being connected These menus are displayed based on the DD file of the particular device If no DD is available for the device the DevCom2000 will select the standard DD This should provide limited functionality for the device NOTE If a parameter is updated that is not supported by the device you will receive an error 2 Expand the menu by clicking the sign and double click to view the device parameters Below is an example of an expanded menu O ua Wend aaa 3 Select the menu and view the associated parameters to view the device information MAN 1010 05 01 2014 Our Quality Management System is Page 21 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual 6 3 Configuring Device Information 6 3 1 Overview DevCom2000 allows you to view and configure the field device parameters based on the device description However the device vendor defines most of the parameters at the factory These parameters become read only for the users and the user cannot modify the values The related variables are gr
32. Protocol HART devices are capable of providing functions and features far beyond the basic task of providing a process input or accepting a control output to manipulate process conditions Many HART compatible device manufactures create a DD Device Description describing all of these functions and features specific to that device The DD also provides information essential to the successful configuration and calibration of the device DevCom2000 uses these DD s to access the data stored in a device providing full configuration and setup support for all registered HART DD s DevCom2000 accesses and presents field device data based solely on its DD No other files information or custom drivers are required DevCom2000 is intended to monitor and configure a single device at a time it is directly connected to the current loop of the particular device and e Provides user interface to configure the HART field device e Provides a means to configure and view all the parameters related to HART field device and e Provides an option to view the detailed status and diagnostic capability of the device DevCom2000 allows viewing and modifying of field device parameters based on the DD Using the device s DD DevCom2000 performs various tests to verify the proper operation of the HART device DevCom2000 runs as a standalone software package and must have a HART compatible modem attached to the system to interrogate the HART base devices A HART modem
33. RL key to select mulitple Analog Output Custom Meter Value Percent of Range Pressure Sensor Temperature Status group 1 Status group 2 Status group 3 Enter Interval 1 Seconds X For how long Second Continuous Enter Filename saved as a tt file e Users ProComSo TESTDEV 1 11 00 Notes 3 Select the information for the log file Select Parameters Select up to four parameters to log at a time Press the CNTRL key to select multiple parameters Enter Interval Input a number and select an interval from the drop MAN 1010 05 01 2014 Our Quality Management System is Page 57 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action down box i e Seconds Minutes Hours Days For How Long Input duration for how long to log the parameter s This part will be grayed out if the Continuous check box is selected Unselect it for a finite duration Filename The default directory is based on Windows User Accounts however a log file can be saved anywhere Notes The section can only be 250 characters long Click the Start button to start logging The logging will then be started At the lower right hand corner of DevCom2000 the Trend Activity light will come on This indicates that there is logging going on You cannot start another log until this one is finished or the user stops the trend manually HART Activi
34. This section explains different aspects of the DevCom2000 application and its functionalities 1 4 Getting Help If you need help or encounter problems when using DevCom2000 or this guide please contact ProComSol Ltd See Appendix B for contact information Please provide the following information Create a text description of the problem If possible provide the text in event sequence which will enable the duplication of the problem Provide information about the system This information must include e DevCom2000 version and License ID e Computer information make model CPU type clock speed attached peripherals and operating environment Windows version e Device information make model and device revision e Point of contact complete mailing address telephone number and e mail address e The date and time of the problem occurrence MAN 1010 05 01 2014 Our Quality Management System is Page 6 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ey C O m2 000 U ser M anu al 2 OVERVIEW OF DEVCOM2000 Field devices such as flow pressure level temperature transmitters and valve positioners provide the physical connection to the process These devices allow the control system to monitor and manipulate process conditions HART devices maintain a real time database of process configuration identification and diagnostic information This information can be accessed using the HART Field Communications
35. Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al QUICK START DevCom2000 uses Device Descriptions DDs to access data stored in the memory of the smart field device These DDs are developed by the manufacturer for their products and in turn distributed by the HART Communication Foundation HCF worldwide The latest DDs are included as part of the DevCom2000 installation Visit the HCF website www hartcomm org or the ProComSol website www procomsol com for update information The following steps will allow you to install and quickly begin using DevCom2000 Step 1 Install the DevCom2000 application Insert the DevCom2000 installation CD into the CD drive on your computer The DevCom2000 installation will automatically start and guide you through the installation process Install DevCom2000 in its default location If the installation program does not begin automatically please go to Start gt Run gt and enter CDRom drive letter DevCom2000Setup exe This will begin the installation program Step 2 Connect the communication interface Connecting to a HART device requires special interface hardware to be attached to your computer These interfaces HART Modems are available from ProComSol Ltd and other sources The interface should be connected and configured Note Many USB to RS232 converters will not work with the HART protocol Due to concerns about port replicators it may be necessary
36. ace you will transmit real time HART data between DevCom2000 and the connected HART compatible field device There are a wide variety of HART compatible interfaces Please follow the manufacturer s instruction for connecting your interface to the PC This manual uses the HART modem manufactured by ProComSol Ltd called the HM USB ISO It uses the USB interface Insert the USB connector on the HM USB ISO into your computer s USB port Using the clips on the wires from the HART interface connect to the device across the 4 20ma signal If a suitable load resistance is not available a 250Q resistor must be placed in series with the device power supply DeyCom 2000 HART Field Device Windows PC HART Interface Figure 1 Typical DevCom2000 Hardware Setup 4 5 Uninstalling the DevCom2000 Application To uninstall the DevCom2000 application perform the following steps Step Action 1 Click Start gt Programs gt ProComSol gt DevCom2000 gt Uninstall DevCom2000 2 Or Click Start gt Settings gt Control Panel gt Add Remove Programs 3 In the Add Remove Programs dialog window select the DevCom2000 program that you want to uninstall 4 Click Remove Click OK to confirm the removing of the selected application MAN 1010 05 01 2014 Our Quality Management System is Page 13 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ey C O m2 000 U ser M anu al 5 USING DEVCOM2000 5 1 S
37. arch By Poll Address v Search by Tag Search by Poll Address WirelessHART Adapter Default use poll address 0 only C ABB Fieldkey 15 C find first poll address Emerson THUM 63 C use polladdress 63 p C Endress Hauser SWA70 15 C search 0 15 search 0 31 search 0 63 Phoeni tact RAD WHA 63 C searchrange 0 through p C Phoenix Contact RAD C Siemens SITRANS AW200 15 MACTek BULLET 15 C Pepperl Fuchs WHA ADP 15 Restore Defaults 3 Select Short Tag from the Search By drop down box Options Basic Search By Advanced Search By Poi Address z Search by Tag Poll Address Search by Poll Address use poll address 0 only find first poll address 4 The poll address options will now be grayed out Enter the tag to be searched for in the Search by Tag edit box Options Basic Search By Advanced Search By Short Tag _z SearchbyTag TESTDEV r Search by Poll Address WirelessHART Adapter Default o a tay a tes tay 2 PP through eo Cancel Restore Defaults MAN 1010 05 01 2014 Our Quality Management System is Page 49 ISO 9001 2008 Certified XN PROCOMSOL DevCom2000 User Manual Process Communications Solutions Step Action Click OK to save the changed settings 5 6 Click Yes if you want to save the changes Clicking No will not save the changes DevCom20
38. ardware 2 Loop power supply is on 3 Loop resistance between 250 ohms and 1Kohms 4 Loop current within HART limits 5 If multi drop configuration all transmitters in loop have unique addresses 6 HART interface hardware connected across loop resistor or across transmitter terminals Software Check Sometimes the application does not end cleanly and the communication process is still running in an unknown state When this happens it must be closed out before restarting DevCom2000 Perform the following 1 Close DevCom2000 2 Press CTRL ALT DEL to bring up the Windows Security Screen 3 Click on Task Manager 4 Select the Processes tab 5 In the list of running tasks select HModemSvr exe 6 Click on the End Process button on the dialog box 7 Restart DevCom2000 Problem Get the message Error opening COMx Verify the following 1 Com port number on Preferences Dialog box matches HART interface hardware 2 HART interface hardware installed MAN 1010 05 01 2014 Our Quality Management System is Page 73 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ey C O m2 000 U ser M anu al Problem No data in the Communication Log Verify the following 1 Verify that the HART Activity LED indicator on the bottom of the screen is flashing red If not open a menu that has dynamic data that is being refreshed like PV or AO 2 For Windows Vista and Windows 7 users you may need to
39. asic Select what COM port the device is connected to and use WirelessHART gateway Search Search by Poll Address Long or Short Tag Advanced Select HART Master Language and DD Startup v Toolbar The View Menu offers the following sub v Status Bar menu options Communication Log Toolbar Hide or show the Tool Bar Device Condition Status Bar Hide or show the Status Bar aaia Communication Log Open the Communication Log window Device Condition View detailed device status Event Status Log View log of events and status changes Example of available The Enhanced menu offers enhanced Enhanced Menus device menus Some devices do not have Enhanced View Below iF available enhanced menus and this menu will only Start say Enhanced View Below if available Device Diagnostics Process Variables No Enhanced Menus available Enhanced View Below if available Define Trend The Trending menu offers the following view Current Trend sub menu options k Ena oe d Define Trend Brings up the Define Trend dialog box where a trend is started View Current Trend Brings up a real time graph of values currently being trended View Past Trends Brings up the View Trend dialog which contains past trend files Selected trend files can then be graphed Stop Current Trend Stops the current log in process MAN 1010 05 01 2014 Our Quality Management System is Page 17 ISO 9001 2008 Certified Na PROCOMSOL Process Commun
40. configure these variables perform the following steps Step Action 1 Ensure that the application is running and communications have been established 4 DevCom2000 Explorer gt i Device Options View Enhanced Trending DD License Window Help e x jale ale 2 6 Online Item Value Units Device Status Good 2 Comm Status Burst a OYE a Configure Ga Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA Upper Range Valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 Device Information A allig r Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM Expand the menu by clicking the sign and double click to view the device parameters Page 25 MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions Step Action 2 4 Select the menu where the required variable is present as shown below PE Online 7 I Device Options View Enhanced Trending DD DTM Window Help 6 xj Ri 3 Balb QJ Device setup GB Process variables 0 00 degC QQ Diag Service PV AO 0 00 m wa PY LRY 0 00 degC Basic set Basic setup Dy PY UR 0 00 degC Detailed setup Sensors J Signal condition H Output condition 9 Analog output E HART output Q Meter Options 5 Device information E Revision s 09 Status D
41. connect the HART interface hardware MAN 1010 05 01 2014 Our Quality Management System is Page 2 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Table of Contents OUICK STAR Do E ate emer eee ene Pee a ee ee eee 1 l APOC LOG praesens enin a EA E E EEE EEA EEEE A TEETER ENE 5 1 1 Acronyms and Definitions eessesseeeeseeseesresressrssessressrsstesrisstssttsressresrenissrestensessresressresresees 5 1 2 Conventions Used in This Manual eeeeeseeseesseeseeseesesresrrssrsssrsrissrssreerrssresrensessresrereessresees 5 1 3 D c ment OrfaniZaON esiis peidar eini ea ka iiaee ESEE se i iiaii iiai 6 L4 Getme TMS esc coca seca patos E EE EE E EE E EEE 6 2 Ov rview oft D eyCom2000 sesiis unrin a E e o a aia E PREi 7 3 System R iremMmentS sssri nieee E ER AE N E ERER E TEE AEE EE EEES 8 4 DevComZ000 Installation sessetessseiressrive ieee re EEE E E E EE AERE 9 Ali Preregtisites sentieri E E R E E aE EEEE AAEE EES 9 4 2 Installing the DevCom2000 Application eseeessesseseessssessessrssrtssissresrtssessresrersrssteseresesrese 9 4 3 Act vating DeyCom2000 ssiri las gl nea E A g eo oon E 9 4 4 Connecting to the HART Network s essesssesseseeeseesessrserrsensessrestersrsstrstnstestensrssresesereseenee 13 4 5 Uninstalling the DevCom2000 Application seesseseeeseseeseresesressrssrrsrersrssessrssressrsereseenee 13 5 Usm Deve Oi ZOO sciens aneen e a E E A koe E E eee 14 5 Startin
42. connect to the Internet to verify the Activation Codes If you do not have an internet connection you can activate it by email or phone using the Manual Activation method Activation details are fully explained later in this manual Activation only needs to occur once MAN 1010 05 01 2014 Our Quality Management System is Page 1 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ey C O m2 000 U ser M anu al Step 5 Set the DevCom2000 Serial Port DevCom2000 uses a default serial port of COM99 The serial port should be changed from Options gt Basic on the DevCom2000 menu to the appropriate serial port for the HART Modem The other settings on the Options tabs typically do not need to be changed Step 6 Browse the Device Operating DevCom2000 is similar to working with Windows Explorer DevCom2000 communicates to the field device establishes a connection and learns its identity Once DevCom2000 knows its identity DevCom2000 locates the device s DD and loads it From this point forward operation of DevCom2000 is determined by the DD provided by the product s manufacturer If a DD for the device is not present a generic DD will be used By default DevCom2000 will open the Browser window The organization of the data in this explorer style window is dictated by the device DD The left hand tree pane of this window shows the logical groups of field device data These are called Menus The right hand data pane sho
43. d 48 status ED amp of By View Communication log View gt Communication log MAN 1010 05 01 2014 Our Quality Management System is Page 18 ISO 9001 2008 Certified XN PROCOMSOL Process Communications Solutions D ey C O m2 000 U ser M anu al View Event log View gt Event Status log amp Launch FDT Frame Future DTM gt Launch FDT Frame 5 2 3 Familiarizing with Icons DevCom2000 application uses different icons to represent different elements of the application Following table lists the icons and their meanings Icon Meaning Indicates a menu or submenu in the navigation tree navigation tree Indicates a currently selected menu or submenu in the pe Online menu icon The actual DD menu comes under this wh Indicates a Variable item uy Indicates a Method Standard Operating Procedure item Eh Indicates an Edit Display item MAN 1010 05 01 2014 Our Quality Management System is Page 19 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al 6 FUNCTIONS AND BASIC OPERATIONS 6 1 Overview DevCom2000 allows the user to monitor and configure a single device at a time in the field Each device is associated with the DD when the device information is present A DD may contain any of the following parameters elements Variable A variable is defined as the data contained in the device e g Device Firmware Version There are two types of va
44. e Options View Enhanced Trending DD License Window Help e x Ri 8 G Online Item Value Units f Overview Device Status Good Configure Comm Status Burst G2 Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA upper Range Valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 1 Device Information lt mg F r Tag P 101_ LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 2 Select Device gt Download from the main window The Download Dialog Box is displayed MAN 1010 05 01 2014 Our Quality Management System is Page 36 ISO 9001 2008 Certified Niu PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Download File Available Sonfguratons Double Click to Selec Configuration Fie Tag mer new ag if desired 6 Cheracer Me LongTaq Descipton TEST UNIT Config ile LoigTagDesc 3 The available configurations are displayed You can sort on each column by clicking it To get details about a configuration select the desired configuration and double click it The details will be displayed below 4 You can change the desired Tag by editing the Configuration File Tag box You can change the desired Description by editing the Config File LongTag Desc box 5 Press the Write button to write device configuration The device must be the same type as the configuration file If they are different the write operation wil
45. e a E E E TE E E 40 6 13 Trending ct cS tae E EE wade En E T 56 MAN 1010 05 01 2014 Our Quality Management System is Page 3 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions Dev Com2000 U ser Man u al 014 DD FUNCHONS isesend a EE a TEE E ETA RE E EEE 66 6 15 HART IP Communication asc cccsecsccepstendsthersioctecseenteusteeys Error Bookmark not defined Appendix A Troubleshooting Guide eseeeeeeseeseeeseesissrsstssessrsstestessrestenserstestestisstestssessteseeeseesresereset 68 Appendix B Contact Information isseire atlieade centile ne adie cn alae 71 MAN 1010 05 01 2014 Our Quality Management System is Page 4 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al 1 INTRODUCTION The Smart Device Communicator DevCom2000 allows access to and management of a HART compatible field device s configuration and calibration This manual provides the information about the Hardware setup Communication with Smart devices and functions of DevCom2000 DevCom2000 is unique in that it uses the DD of the connected device to determine what information to display what variables are available for edit and what procedures to follow for calibration setup and maintenance 1 1 Acronyms and Definitions Acronym Definition COTS Commercial off the Shelf DD Device Description File This contains the device information DDL Device Description Lan
46. e graph as desired Below is an example of one of the Properties tabs Plot Control Layout Channels Cursors Limits Labels X Axes Y Axes Legend Tables ToolBar Data View General Tite Background Print Hints File YO Annotation Detaults Border Style Outer Margin Copy To ClipBoerd Format Meta File Ed C None 5 2 File Column Separator Tab vj C Raised 5 S 5 Lowered 5 Cip Annotations To Axes Update Frame Rate 60 4 Auto Frame Rate Copy To Clipboard The Copy To Clipboard button copies the graph to the clipboard to allow the graph to be pasted into documents like a report Save The Save button el _ saves the graph as a bmp Print The Print button prints the graph Preview The Preview button L gives a print preview of the graph Title The title gives the name of the parameter being trended the units that the parameter is being measured in and the date s of the graph Parameter Units Date Axis The Y axis is the units of the parameter The X axis is the time in HH MM SS format MAN 1010 05 01 2014 Our Quality Management System is Page 64 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions Step Action Redraw Up to four parameters can be trended at the same time By clicking the check box for a parameter u can show one or four at the same time for easy compari
47. ep Action A DevCom2000 Explorer e pt View a 93 2 88 B Online item Value Units Overview Pressure Units intt20 Device information Dampeng 0 80 see Identification Transfer function Linear HART gt Sensor Temperature Units degt Materials of Construction RS Materials of Construction Analog Alarm Security Configure Guided Setup Q Basic Setup Configure Display 5 Manual Setup amp Process Variables Analog Output Display HART Security Device Information Identification flange Ma Remate Casi Tag P 101 _ LongTag Desc TEST UNIT Device 3051 DO 26 06 03 07 HART Activit Trend Activit NUM Sensor Temperature Units 4 Make the changes to the parameter value as required 5 Click Set to accept the changed value The change gets reflected as shown A DevComn2000 Explorer E Device Options View Enhanced Trending DD License Window Help a2e2e2 028 Online a Tem Value Units amp Overview 1D Pressure Units inn20 Device Information 12 Damping 0 00 sec Identification Transfer Function linear HART 2 BensorTemperstere Units a Materials of Construction fe RS Materials of Construction je Analog Alarm Security Configure Guided Setup Basic Setup Configure Display Manual Setup amp Process Variables Analog Output Display HART Security Device information Kentification Flange n Qamara Cesl Tag P 101
48. ess Communications Solutions DevCom2000 User Manual Step Action Device Condition Device Status Status group 1 Status group 2 Status group 3 Device Status Device malfunctioning lt Configuration changed lt Cold start lt More status available PV AO fxed PVAO saturated e o Non primary variable out of limits lt Primary variable out of limits The Device Status tab option shows the status of the device and the communication network The individual status is indicated by green and red LEDs 4 Additional tabs may be available depending on the DD Click X to close the Status window 6 6 Viewing the Communication Log DevCom2000 allows the user to view the actual communications between DevCom2000 and the device You can view send commands and received responses If your computer is running an anti virus program such as McAfee you may get a message about a program wanting to access the internet when you open the Communication Log This is normal DevCom2000 uses TCP IP to communicate with the Communication Log program If no data appears in the Communication Log this may be due to an anti virus program Close the Log window and re launch To view the communication log perform the following steps Step Action 1 Ensure that the application is running and communications have been established MAN 1010 05 01 2014 Our Quality Management System is Page 31 ISO 9001
49. g DeyCom2000 scaseccastiavdeeeatys custvasesiea vesie cxsdchnssedeatasscenebsusuczaiaavacdasbadeueses wababaseuciueied 14 5 2 Getting Familiarized with DevCom2000 Explorer eee eeseeseeeneeeseeeeneceseeeseeeeeeesnes 16 6 Functions and Basic Operating oy oai tc csacsianenassecasaacsstonsseacaenesisdacpnanasagensnadanbeaieaatuusasanennieeetenseceene 20 Gil SVC VIC Ws E atin csecedsecnnans secon ES 20 6 2 Viewing Device Configuration typical actual view may change based on DD 20 6 3 Configuring Device IniiormiathOi a a ca ctacenccorsqpcstesaderacstedanneseeneceteeoaleeadieacieeinettaiaestacks 22 6 4 Calibrating HART Field Dye yes icc sco scbcabeesytaseasiutustencyacveccepeabtecpta ees Ere eA EEA 29 6 5 Viewing the Device and Communication Status s cscccssscsseasseeescnescensaseareaesanseenansenne 30 6 6 Viewing the Communication LOg cicccccassccccccsecascntescesnsnsstecsatesececansovastasucceessasseavansseensates 31 6 7 Viewing the Event Stats Log ages spoccetocestvcusy csv satees erisir Eea NE EEEE i 33 6 8 Saving Device Configuration to Disk eseesssessessesrrsrreresrersresrrssrssresererssrersrseresrensessresees 34 6 9 Download Configuration to Device ssesessesesseeesissrrsrssrisrersessriserssttsreserestenriseresrensessresres 36 6 10 C stomizing PDF File Output sisii cerieisa eioan kiani n iii s 37 GM License File TransferS viscriccd rehier oti ekeni EEEN EEEE aE SEERE R KRE REKEN EEEak 39 6 12 Options Men ee e
50. guage HCF HART Communication Foundation DevCom2000 Smart Device Communicator Software 1 2 Conventions Used in This Manual Following formatting conventions are used in this guide Convention Description Words in bold type Field names including buttons in the display or important phrases gt Arrow Windows pull down menus and their options are separated by gt For example click Device gt New Device to connect to a new device Courier font Information that you type parts of the code quoted for explanations or as examples UPPERCASE Acronyms UPPERCASE within Command keys angle brackets For example press lt ENTER gt MAN 1010 05 01 2014 Our Quality Management System is Page 5 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ev C O m2 000 U ser M anu al 1 3 Document Organization DevCom2000 user manual is organized into the following sections Section 1 Describes the scope and objective of DevCom2000 user manual along with the organization of the remaining part of the manual Section 2 Provides an overview of the DevCom2000 application and its architecture Section 3 Provides the information pertaining to hardware and software requirements for the DevCom2000 application Section 4 Provides the steps to install activate and uninstall the DevCom2000 application Section 5 Provides the steps to start the DevCom2000 application and connecting to field devices Section 6
51. guration details Detailed Scan Close 4 Click on Detailed Scan to display all the devices as a heirarchy This will show what transmitters are connected to each WirelessHART adapter Note that this listing takes significantly longer to generate than the Quick Scan Below is a sample screen ja Device Options View Enhanced Trending DD License Window Help AlE 3 2 VvirelessHART Network Device Selection a g wihartgw 6 BULLET WITH 3095 HANNOVER MESSE 2013 B MODEM TEST S E THUM WITH 3144 3144 ON THUM B WIRELESS 648 Status 0 0 13 0 74 084 0 Click Quick Scan to display all devices in Network Click Detailed Scan to display all devices in Network Heirarchy Note Yill be significantly slower than Quick Scan Double Click on desired device above for configuration details Close Quick Scan MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Page 71 Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual For both types of list displays the following icons are used HART IP Icons Gateway q Adapter WirelessHART g Transmitter 5 Once a device list has been created double click on the desired device to configure review using DevCom2000 Below is a sample screen A4 DevCom2000 Explorer m Device Options View Enhanced Trending DD License Window Help R12 39 2 a 5 3 Online amp Overview G2 Device Informati
52. ications Solutions DevCom2000 User Manual Add DD The DD menu offers the following sub Available DDs menu options Add DD Brings up the dialog that adds a DD to the library Also used to give labels to non standard library DDs Available DDs Brings up a browser of all the DDs installed in the library Launch FDT Frame The DTM menu offers the following sub menu options Launch FDT Frame launches the FDT Future Frame program DevCom2000 Help The Help menu offers the following sub Com Troubleshooter menu options pene _ DevCom2000 Help Brings up Help HEE information for the DevCom2000 application Com Troubleshooter Brings up the DevCom2000 Com Troubleshooter Device Help Brings up help information for the connected device if available About DevCom2000 Shows copyright information support information and application Version Number 5 2 2 Using the Toolbar When you start the application by default the toolbar buttons appears on the main window If it fails to display click View gt Toolbar option from the menu bar to bring up the toolbar Following are the buttons available in the DevCom2000 application toolbar to perform the necessary tasks Button Description Corresponding Menu Option Connect to a new device Device gt New Device Send parameter changes to the device Cancel parameter changes View more status on Device View gt Device Condition and Communication Comman
53. ice is connected to DevCom2000 the browser window appears with online i e root menu selected 5 si 8 a 7 i The left pane of the window shows the menu structure and the right pane of the window displays corresponding parameters of the menu selected The DevCom2000 screens shown in this document are only an example of what you may see when connected to your field device What you see is actually controlled by the DD and the device The menus data status and configurations displayed are specified by the field device s manufacturer in the DD itself 5 Select the required menu to configure or review the field device s data 5 2 Getting Familiarized with DevCom2000 Explorer 5 2 1 Using the Menus DevCom2000 Explorer provides visual representation and structure of the application window Menu Explanation New Device Ctrl N The Device Menu offers the following Document Device sub menu options Download View New Device Connect to a new device or reconnect to the same device Exit Document Device Brings up the Document Device dialog box Download View Brings up the Download dialog box which provides Configuration File features Exit Exit DevCom2000 MAN 1010 05 01 2014 Our Quality Management System is Page 16 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Basic The Options Menu offers the following Search sub menu options pateta B
54. ith the Basic tab selected MAN 1010 05 01 2014 Our Quality Management System is Page 44 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action Options Basic Search By Advanced Modern Server Preferences Serial Port COM40 h available Online DevCom2000 Use TCP IP with WirelessHART Gateway IP Address 192 168 1 1 Advanced Settings Port 5094 Use HART Server with WirelessHART Gateway or HART Multiplexer Note HART Server must be purchased from the HART Foundation Cancel Restore Defaults 3 Click Use HART server with WirelessHART Gateway or HART Multiplexer Options Basic Search By Advanced Modem Server Preferences Serial Port COM40 v available Online DevCom2000 I Use TCP IP with WirelessHART Gateway IP Address 192 168 1 2 1 Advanced Settings Port 5094 v Use HART Server with WirelessHART Gateway or HART Multiplexer Note HART Server must be purchased from the HART Foundation Cancel Restore Defaults 4 The Serial Port option will now be grayed out Un checking will make Serial Port selectable again Click OK to save the changed settings 5 Click Yes if you want to save the changes Clicking No will not save the changes MAN 1010 05 01 2014 Our Quality Management System is Page 45 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Soluti
55. l button A is grayed out while tracking If either axis is changed or the Pause button is pressed this will be come green B Pressing Resume All Tracking will resume the tracking on the graph Pause All Tracking The Pause button Il pauses the graph in its current state Data is still added however the current X axis and Y axis spans no longer change Pressing the Resume button will continue tracking Scroll Axis This is the default way to scroll both the X and Y axis The Scroll Axis button a allows the user to scroll in both directions on the graph MAN 1010 05 01 2014 Our Quality Management System is Page 59 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Zoom Axis The Zoom Axis button amp allows the user to shrink or enlarge the scale of either axis By moving up or down left or right the span of each axis is changed Zoom Out All Axis The Zoom Out All Axis button ee zooms out both the X axis and Y axis at the same time giving the user a broader look at the graph Zoom In All Axis The Zoom In All Axis button Ei zooms in both the X axis and Y axis at the same time giving the user view over a smaller time period peeeney Zoom Box The Zoom Box button t i changes the cursor allowing the user to select a specific area of the graph to zoom in on for a mo
56. l be aborted 6 You can view the PDF file for the configuration file by double clicking on the desired configuration and pressing View 7 You can delete configurations by double clicking on the desired configuration and pressing Delete 6 10 Customizing PDF File Output HART Device configurations can also be saved to disk as PDF Files to document the device The header footer and technician name can be entered to customize the PDF file to make it into a configuration report To customize the PDF output perform the following steps MAN 1010 05 01 2014 Our Quality Management System is Page 37 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 User Manu al Step Action 1 Press the PDF Setup button on Document Device Dialog Box Document Device File Name CAProgramFiles ProComSoh DevCom2000 PDFT est_l tt Notes Notes must be less than 250 characters Save Device Config PDF Setup Close 2 The PDF Setup Dialog box is displayed PDF Setup Header User Manual Device Config Footer Footer for Device Config Tech Guyinetument PDF Text Scaling Scale Value 98 Note Larger the value the smaller the text 96 is default value use 120 on small screens 3 Enter data as needed and press OK The data is saved for future configuration saves 4 Below is a sample PDF file MAN 1010 05 01 2014 Our Quality Management S
57. ndow Help ei x al sla B 5 6 Online Item Value Units E overview 1 Device Status Good 9 Configure Comm Status Burst amp Service Tools Pressure 2 1 inH20 f amp Analog Output 11 331 mA 2 upper Range Valu 40 0 inH20 ND Lower Range Value 4 mA 30 0 inH20 2 Device Information lt u r Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 e HART Activit Trend Activit NUM 2 Select Options gt Advanced from the main window The Options Dialog Box is displayed with the Advanced tab selected Options mer Basic Search By Advenced HART Master DD Startup Primoy Device DD C Secondary C Genenc DOO Select Language Change in language will not take effect until English DevCom2000 is restarted Dont Connect to Device On Startup OK Cancel Restore Detouts MAN 1010 05 01 2014 Our Quality Management System is Page 55 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action 3 Click the Restore Defaults button 4 DevCom2000 will ask if you want to restore the default settings Click Yes DevCom2000 A Restore to Default Settings 5 If the restore was successful the following dialog box will be shown 6 Click OK to save the changed settings 7 Click Yes if you want to save the changes Clicking no will not save the changes DevCom200
58. not the DD with default to English 6 12 4 3 DD Startup During normal startup of DevCom2000 the device is found and then the DD is loaded If the DD cannot be found then a generic DD is loaded Advanced has settings that can change what DD DevCom2000 loads with loading a device To load a generic DD at start up or to not load a DD at all perform the following steps Step Action 1 Ensure that the application is running A DevCom2000 Explorer Lo S E Device Options View Enhanced Trending DD License Window Help a x ai 3 5 Online Item Value Units ERS Overview Device Status Good 2 Configure 2 Comm Status Burst amp Service Tools f Pressure 2 1 inH20 amp Analog Output 11 331 mA upper Range valu 40 0 inH20 2 Lower Range Value 4 ma 30 0 inH20 2 Device Information lt m Tag P 101 _ LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM MAN 1010 05 01 2014 Our Quality Management System is Page 53 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action 2 Select Options gt Advanced from the main window The Options Dialog Box is displayed with the Advanced tab selected Basic Search By Advanced HART Master OD Startup Primary Device DD Secondary C Generic DO Select Language Change in language will not take effect until ie
59. nual Step Action Enter a URL text address in the URL field and click the Resolve button to convert it into an IP Address The IP Address will populate the IP Address box if a successful conversion occurs Gateway Address Some WirelessHART Gateways do not use the default address of 0 For these Gateways you must enter the correct Gateway Address in this field 6 12 1 3 Using HART Server The Basic menu is used to set DevCom2000 to communicate with a WirelessHART gateway or HART multiplexer This requires an external program called HART Server Although DevCom2000 can use HART Server for WirelessHART communications it is recommended that HART IP be used To communicate with a WirelessHART Gateway or a HART multiplexer perform the following steps Step Action 1 Ensure that the application is running A4 DevCom2000 Explorer a Device Options View Enhanced Trending DD License Window Help e x AIle Online Item Value Units aie Overview Device Status Good H Configure 2 Comm Status Burst amp Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA upper Range Valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 4 Device Information lt m r Tag P 101 _ LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 2 Select Options gt Basic from the main window The Options Dialog Box is displayed w
60. on 2 Configure amp Guided Setup Basic Setup Configure Display Item Value Units d Pressure Units Damping 2 Transfer Function 2 Sensor Temperature Units amp Pressure f Sensor Temperature inH20 0 80 sec Linear degF 0 6 inH20 70 8 degF 5 Manual Setup amp Process Variables Analog Output Display a HART Security amp Q Device Information Identification Flange Remote Seal amp Service Tools Alerts Variables Trends G Maintenance a Simulate Tag P 101 _ LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 6 To switch to a different device on the WirelessHART network Select Window on the MENU bar then click on HART IP Device Selection to bring up the Device Menu Tree again g DD License Help Cascade Tile 1 Explorer 2 HART IP Device Selection Page 72 MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions D ey C O m2 000 U ser M anu al Appendix A Troubleshooting Guide For most error messages there is a selection for Com Troubleshooter This program will guide you through the steps to solve your communication problems Below is a quick summary Problem Will not communicate Hardware Check Verify the following 1 Com port number on Preferences Dialog box matches HART interface h
61. ons DevCom2000 User Manual Step Action 6 DevCom2000 Are you sure you want to save the changes you made to your preferences No Restart DevCom2000 for the changes to take place 6 12 3 Options gt Search 6 12 3 1 Poll Address The Search menu is used to change how DevCom2000 searches for a Device The first option is to search by Poll Address This searches for a specific poll address or set of addresses To search for a device using Poll Address perform these steps Step Action l Ensure that the application is running DevCom2000 Explorer a Device Options View Enhanced Trending DD License Window Help AIF E G3 Online Item Value Units Sa Overview Device Status Good Configure Comm Status Burst Service Tools Pressure 2 1 inH20 Analog Output 11 331 mA Upper Range Valu 40 0 inH20 Lower Range Value 4 mA 30 0 inH20 5 Device Information 4 uli Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 2 Select Options gt Search from the main window The Options Dialog Box is displayed with the Search By tab selected MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified Page 46 XN PROCOMSOL Process Communications Solutions Step Action Options Basic Search By Advanced Search By Search by Poll Address use
62. ouped under various menus of different levels as defined in the DD file Expand or collapse the tree view using the or sign to access the device configuration parameters Following table describes the details about the device configuration Step Action 1 Ensure that the application is running and communications have been established Device Options 2 238 E EE TILL Tag Dese TEST UNIT device 3051 26 06 HARI Acton Teens Actwit The left pane of the window shows the menu structure and the right pane of the window displays corresponding parameters of the menu selected 2 Expand the menu by clicking the sign and double click to view the device parameters 3 There are three types of variables dynamic read write and read only The parameters that are grayed out indicate that these are dynamic variables variables that get updated online by the device or read only variables Following points describe how the device parameters represents their status when connected to DevCom2000 Bold Font Modifiable Values Normal Font Menu Item 4 Select the parameter and configure the values as required MAN 1010 05 01 2014 Our Quality Management System is Page 22 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions Step Action 5 The subsequent topics explain how to configure device parameters 6 3 2 Variable To edit the parameter variables
63. ows the user to add a Label for a DD if there is not one already defined Below is an example MAN 1010 05 01 2014 Our Quality Management System is Page 67 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 User Manu al xl D Library DD Revision Standard 000 Ametek 0x03 Brooks Instrument 0x04 Daniel Industries 0x0D Endress amp Hauser 0x11 ABB 0x12 Fisher Controls 013 5 Position Xmitter 0x00 C 0x02 9 DYC6E000 0x03 4 0x04 4 D C2000 0x05 H 0x07 C Foxboro 0x14 4 Fuji 015 4 ABB 0x16 CI Honeywell 0x17 CODDOD a 2 8 8 The manufacturer ID of Fisher Controls is 000013 Device IDs 0002 0004 and 0007 all do not have a label This is when updating a DD label is useful To update the label perform the following steps Step Action 1 Ensure that the application is running you do not have to be connected to a device to use Add DD A DevCom2000 Explorer la Device Options View Enhanced Trending DD License Window Help CEREALE Item ERROR Failed to acquire a device identity HART Activit Trend Activit 2 Select DD gt Add DD from the main window 3 The Add DD dialog will open MAN 1010 05 01 2014 Our Quality Management System is Page 68
64. poll address 0 only find first poll address use poll address 63 C search 0 15 search 0 31 C search 0 63 C seerchrange 0 Poll Address v Search by Tag WirelessHART Adapter Default ABB FieldKey 15 Emerson THUM 63 Endress Hauser SWA70 15 MACTek BULLET 15 Pepperl Fuchs WHA ADP 15 Phoenix Contact RAD WHA 63 DevCom2000 User Manual Siemens SITRANS AW 200 15 Restore Defaults 3 There are currently nine options for Poll address e use poll address 0 only only searches at poll address 0 before not finding a device This is the default setting e find first poll address searches poll addresses until it finds the first device it comes across e use poll address ___ If the poll address is know this options searches at a specific address i e 5 e search 0 15 searches poll addresses 0 through 15 e search 0 31 searches poll addresses 0 through 31 e search 0 63 searches poll addresses 0 through 63 e search range through __ searches between a user identified range of poll addresses e MACTek Bullet 15 searches poll address 15 e Emerson Process Management THUM 63 searches poll address 63 4 The Search by Tag option is grayed out when searching by poll address Select a search by poll address option and Click OK to save the changed settings 5 Click Yes if you want to save the changes Clicking No will not save the changes
65. re detailed look Cursor The Cursor button rl _ adds a cursor to the screen that gives the coordinates of the graph at a certain time Clicking and moving the cursor can give the coordinates of any point on the graph See below for an example of using the Cursor tool ee 0 0 E Properties The Properties button brings up the Properties dialog box which gives the user the ability to customize the graph as desired Below is an example of one of the Properties tabs Plot Control Layout Channels Cursors Limits Labels x Aves Y Axes Legend Tables ToolBar Data View Generel Title Background Prim Hints File yO Annotation Detoults Border Style Outer Margin Copy To ClipBoard Format Meta File X C None 5 File Column Separator Tab ha 5 Ai 5 2J J Cip Annotations To Axes Update Frame Rate 60 a F Ato Frame Rate MAN 1010 05 01 2014 Our Quality Management System is Page 60 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Copy To Clipboard The Copy To Clipboard button copies the graph to the clipboard to allow the graph to be pasted into documents like a report Save The Save button saves the graph as a bmp Print The Print button amp prints the graph Preview The Preview button L amp gives a print preview of
66. riables Editable Variable It allows the operator to modify the value and download it to the device Non Editable Variable It is a read only data from the device Edit Display This option is used to view a group of parameters You can also modify a single parameter from this group based on which other parameters of the device get altered For example if the Engineering Unit of the device is modified the corresponding Low Limits and High Limits change as per the Engineering Unit set Method Standard Operating Procedure SOP This option helps to perform various tests on the device for instance Self Test and Loop Test A Method or SOP is a series of steps that are executed in a sequence results in the completion of some device related tasks When a method gets invoked it gives various warning messages and options to the user by which the user can thoroughly test the device If a test is aborted by operator command at any stage of the sequence the method invokes additional steps to bring the device back to its original state before the test 6 2 Viewing Device Configuration typical actual view may change based on DD To view the configuration of the device that is connected to DevCom2000 perform the following steps Step Action 1 Ensure that the application is running and communications have been established MAN 1010 05 01 2014 Our Quality Management System is Page 20 ISO 9001 2008 Certified AY PROCOMSOL
67. son over a period of time IV Pressure inH20 l Graph 3 M Graph 2 l Graph 4 Click Redraw and the parameters checked will be shown 6 13 4 Stop Current Trend Step Action 1 Ensure that the application is running and is connected to a device Ny DevCoen2000 fexplorer Device Options View Enhanced Trending DO Liemse Window Help x 2 e 28 D Orne 3 CESSES 1 _ LongTag Dese TEST UNIT Device 3051 00 26 06 007 HARI Acn Teens Acowit Ensure that a trend is in progress The Trend Activity light at the bottom of the screen is on if a trend is in progress If not then the light will be off HART Activit Trend Activit NUM Select Trending gt Stop Current Trend from the main window You will be asked if you want to stop the current trend Click Yes This will stop the current trend MAN 1010 05 01 2014 Our Quality Management System is ISO 9001 2008 Certified DevCom2000 User Manual Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action DevCom2000 freer al Q Do you want to stop the current Trend in progress vs No 5 The Trend Activity light will now be off HART Activit Trend Activit NUN m M O 6 14 DD Functions 6 14 1 Adding a DD DevCom2000 allows the user to add a DD to the library when necessary Each DD must be in its appropriate destination for DevCom2000 to find the DD The format is C
68. stem is Page 41 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manu al 6 12 1 2 Use HART IP with a WirelessHART Gateway The Basic menu is where DevCom2000 can be set to use HART IP to communicate with a WirelessHART Gateway To communicate using HART IP with WirelessHART Gateway perform the following steps Step Action 1 Ensure that the application is running a 4 DevCom2000 Explorer gt a jm Device Options View Enhanced Trending DD License Window Help a x A 8 5G Online Item Value Units m Overview Device Status Good 2 Configure 2 Comm Status Burst G Service Tools f Pressure 2 1 inH20 Analog Output 11 331 mA upper Range valu 40 0 inH20 2 Lower Range Value 4 ma 30 0 inH20 Device Information lt m r Tag P 101 _ LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM 2 Select Options gt Basic from the main window The Options Dialog Box is displayed with the Basic tab selected Options Basic Search By Advanced Modem Server Preferences Serial Port COM40 bd available Online DevCom2000 I Use TCP IP with WirelessHART Gateway IP Address 192 168 1 11 Advanced Settings Port 5094 Use HART Server with WirelessHART Gateway or HART Multiplexer Note HART Server must be purchased from the HART Foundation
69. t Trend Activit NUM 6 13 2 View Current Trend When a trend is created DevCom2000 creates a window that shows the graph of the current trend To view this trend perform the following steps Step Action 1 Ensure that the application is running and is connected to a device Ef CSSEEIT i ati F 2 Ensure that a trend is in progress The Trend Activity light at the bottom of the screen is on if a trend is in progress If not then the MAN 1010 05 01 2014 Our Quality Management System is Page 58 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action light will be off HART Activit Trend Activit NUM 3 Select Trending gt View Current Trend from the main window 4 The DevCom2000 Trend dialog opens up A DevCom2000 Trending Waveform Device Options View Entarxed Trending OD License Window Help 2 28 Dt k QQ Or F RES P 101__ LongTag Desx TEST UNIT Device 3051 DO 26 06 03 07 HART Activit Trend Activit NUM The user can manipulate the graph as desired Tracking is the term used to describe how the graph control follows the data changing the axis in real time so that all of the data is shown Below are the specific parts of the graph Tool Bar There are multiple things that the user can do with the graph N e QQ e SHER Resume All Tracking The Resume Al
70. tarting DevCom2000 The HART compatible field device must be connected to a PC or tablet running DevCom2000 to configure or calibrate the field device or to view the field device s data Make sure to establish the physical connection between the field device and the DevCom2000 computer With the physical connection established launch DevCom2000 by clicking the DevCom2000 icon on your desktop You can also start the application by going to your computer s Start Menu and selecting Start gt Programs gt ProComSol gt DevCom2000 gt DevCom2000 If your computer is running an anti virus program such as McAfee you may get a message about a program wanting to access the internet This is normal DevCom2000 uses TCP IP to communicate with the Communication Log program Step Action l Start the DevCom2000 Application The following application window is displayed ewe Opoors View Enhanced Trending DD License Window Help 2 e 2 JE DevCom2000 will then automatically identify the field device and open a communication channel to i e a connection with the field device 2 Setting Options Options gt Basic If communications cannot be established you may need to change the communication settings using the Options dialog box The serial port box will show the available com ports Select the one your HART modem is using MAN 1010 05 01 2014 Our Quality Management System is Page 14 ISO 9001 2008 Certified Ay PROGOMSOL Process
71. the graph Title The title gives the name of the parameter being trended the units that the parameter is being measured in and the date s of the graph Parameter Units Date Axis The Y axis is the units of the parameter The X axis is the time in HH MM SS format Redraw This section is disabled for View Current Trend 6 13 3 View Past Trends DevCom2000 keeps a list of trends that have been done in the past These trends are saved so that they can be viewed at a later date To select a trend to be viewed perform the following steps Step Action 1 Ensure that the application is running you do not have to be connected to a device to use View Past Trends eo ERROR Failed to acquire a Gewice identity HART Act Trend Activit 2 Select Trending gt View Past Trends from the main window 3 The Select Trend To Graph dialog will open MAN 1010 05 01 2014 Our Quality Management System is Page 61 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action LongTagDese 0 TEST 15 4024 15 4451 155718 16 4239 101208 10 15 48 10 31 31 TEST TEST TEST VERIFY DES VERIFY DESC r Parameters Logged cnpton Parameter 1 A Porometer 2 Device Parameter 3 Porometer 4 File Nome Notes secton cannot be longer than 250 characters Graph x Detete This dialog box is very similar to the Download View dialog box Data Opens the
72. ton will continue tracking Scroll Axis This is the default way to scroll both the X and Y axis The Scroll Axis button F allows the user to scroll in both directions on the graph Zoom Axis The Zoom Axis button amp allows the user to shrink or enlarge the scale of either axis By moving up or down left or right the span of each axis is changed Zoom Out All Axis The Zoom Out All Axis button amp zooms out both the X axis and Y axis at the same time giving the user a broader look at the graph Zoom In All Axis The Zoom In All Axis button Q zooms in both the X axis and Y axis at the same time giving the user view over a smaller time period peveney Zoom Box The Zoom Box button i changes the cursor allowing the user to select a specific area of the graph to zoom in on for a more detailed look Cursor The Cursor button rl adds a cursor to the screen that gives the coordinates of the graph at a certain time Clicking and moving the cursor can give the coordinates of any point on the graph See below for an example of using the Cursor tool MAN 1010 05 01 2014 Our Quality Management System is Page 63 ISO 9001 2008 Certified Na PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action Properties The Properties button brings up the Properties dialog box which gives the user the ability to customize th
73. ttings for HART IP have been made in the Options gt Basic menu Note that a HART Modem is NOT required only Ethernet access to the WirelessHART Gateway 2 Click on New Device icon to start the connection process The following screen will appear E Device Options View Enhanced Trending DD License Window Help Al 3 2 VvirelessHART Network Device Selection Status Click Quick Scan to display all devices in Network Click Detailed Scan to display all devices in Network Heirarchy Note Will be significantly slower than Quick Scan Double Click on desired device above for configuration details Detailed Scan Close 3 Click on Quick Scan to provide a simple list of all the devices on the WirelessHART network Below is a sample screen MAN 1010 05 01 2014 Our Quality Management System is Page 70 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manu al jm Device Options View Enhanced Trending DD License Window Help rli8 3 2 WirelessHART Network Device Selection a g wihatgw 3144 ON THUM BULLET WITH 3095 HANNOVER MESSE 2013 MODEM TEST THUM WITH 3144 WIRELESS 648 Status 0 013 0 74 0 84 0 Click Quick Scan to display all devices in Network Click Detailed Scan to display all devices in Network Heirarchy Note Will be significantly slower than Quick Scan Double Click on desired device above for confi
74. tus Log DevCom2000 allows the user to view the error conditions of the device and the communication network To view the Event Status Log perform the following steps Step Action 1 Ensure that the application is running and communications have been established A DevCom2000 Explorer Lo S E Device Options View Enhanced Trending DD License Window Help x A232 5G Online Item Value Units ERS Overview Device Status Good 2 Configure 2 Comm Status Burst amp Service Tools N Pressure 2 1 inH20 amp Analog Output 11 331 mA upper Range valu 40 0 inH20 2 Lower Range Value 4 ma 30 0 inH20 2 Device Information lt m Tag P 101 LongTag Desc TEST UNIT Device 3051 DD 26 06 03 07 HART Activit Trend Activit NUM Expand the menu by clicking the sign and double click to view the device parameters 2 Select View gt Event Status Log from the main window or choose the Event Status log icon amp from the toolbar An additional Event Status window is displayed MAN 1010 05 01 2014 Our Quality Management System is Page 33 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 User Manual Step Action N Devcom2eex Exgiorer ee ner Gmund Trending OO License Window Help Tag P 101 _ LoagTag Dese TEST UNIT Device 3051 DO 26 06 03 0 HART sete Tresa Active 3 To close go to View gt
75. ws the data any sub groups and any standard operating procedures found on a given menu You can browse through the field device data by expanding click symbol or collapsing click the the menus in the tree pane You can also double click the folder symbol when seen on the data pane symbol Step 7 Modify the Device s Configuration The Browser allows access to all of the data exactly as described by the product s manufacturer s DD When you find elements of the field device s configuration you want to change simply double click and edit the data Once you have changed the configuration to suit your needs press the Send icon 2 to commit the data and transfer it to the field device Step 8 Performing Maintenance and Testing the Field Device Many devices perform Methods or Standard Operating Procedures SOPs that may need to be performed to ensure the device is in peak condition These Methods may include calibrating the loop current trimming the transducer values or performing some diagnostic test on the field device Methods appear in the data pane just like data does Double click on the Method and it will start running in a separate window The Method will guide you through the process ensuring the procedure is completely and consistently performed When the Method is complete the window will disappear Step 9 Exit When you are through working on the field device simply exit DevCom2000 Once the program exits you can then dis
76. ystem is Page 38 ISO 9001 2008 Certified Y PROCOMSOL Process Communications Solutions DevCom2000 User Manual Step Action User Manual Device Config DevCom2000 Rev 4 6 Device Configuration File File C Program Files ProComSoliDevCom2000 TESTDEV _1 1 pdf Tag TESTDEV LongTag Desc DEV DESC HERE Device ID 1 DD 26 19 01 08 Date vyvv mm dd 2011 02 17 Time hr mn sc 03 58 57 PM Tech Guy Instrument Notes this is a saved device config Label Value Units Xfer fnetn Linear AO 0 00 mA AO alrm typ H Unit ohm Term temp unit degR rage 0 00 Term temp 0 00 deac Term Upr Rna 10 00 deac Term Lor Rna 0 00 deac Term temp USL 0 00 degC Term temp LSL 0 00 degC Term temp damp 0 00 s Dif min span 0 00 Snsrt 0 00 ohm Snsr1 snsr s n 1 Snsr1 Upr Rng 0 00 ohm Snsr1 Lor Rng 0 00 ohm Snsr1 USL 0 00 ohm Snsrt LSL 0 00 ohm Snsrt damp 0 00 s Snsr1 Min Span 0 00 ohm Snsr 1 Type Ohms Snsr 1 Conn 2 Wire Meter typ Eng unit Meter decimal pt Floating decimal pt Meter bar graph Bar graph off 50 60 Hz filter 60 Hz Snsr 1 Cal Mode Factory Trim Footer for Dev Config Page 1 of 3 6 11 License File Transfers The license file can be transferred easily to other computers The process is a Check In Check Out process When a license is on the computer it is considered Checked Out When the license is on the license server it is considered Checked In When the license is Checked in it can