1. 30 76 2 cm minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or 24 60 9 cm minimum when bottom of wood or metal cabinet is protected by not less than 1 4 6 4 cm flame retardant millboard covered with not less than no 28 MSG sheet steel 0 015 0 381 mm stainless steel 0 024 0 610 mm aluminum or 0 020 0 508 mm copper 15 38 1 cm minimum between countertop and adjacent cabinet bottom 4 Part2 PREPARE TO INSTALL THE RANGE NOTE 2 INSTALLATION DRAWINGS LSE Series only SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR CLEARANCES AND DIMENSIONS Figure 1 To install range refer to the following Figure 1 For installation in CANADA a Free standing range is not to be installed closer than 15 32 12mm from any adjacent surface 4 CAUTION e Make sure that the wall covering countertop and cabinets around the range can withstand the heat up to 194 F generated by the range Discoloration delamination or melting may occur This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 F A 24 60 9cm 24 A im 1 25 Normal 63 5cm counter Acceptable Ey top depth electrical outlet area 1 1 1 i 36 9 p y Ulli A A Cabinet y 24 A opening L 60 9cm Counter 1 4cm top height 36 91 4cm
2. gt 76 2cm A 30 76 2 cm For U S A 30 76 2 cm 31 78 7 cm For CANADA FIGURE 1 MINIMUM DIMENSIONS Figure 2 4 CAUTION e Cabinet storage space located above the surface units should be avoided e Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets If cabinet storage is to be provided The risk of burns or fire by reaching over the heated surface elements can be reduced E 30 gt 76 2cm 30 76 2cm Minimum t 15 38 1cm FIGURE 2 30 76 2 cm minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or 24 60 9 cm minimum when bottom of wood or metal cabinet is protected by not less than 1 4 6 4 cm flame retardant millboard covered with not less than no 28 MSG sheet steel 0 015 0 381 mm stainless steel 0 024 0 610 mm aluminum or 0 020 0 508 mm copper 15 38 1 cm minimum between countertop and adjacent cabinet bottom 5 Part3 ELECTRICAL CONNECTIONS 3 ELECTRICAL CONNECTION REQUIREMENTS This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI NFPA NO 70 latest edition All wiring should conform to Local and NEC This range requires a singl
3. connection Black White Red Terminal block Es ae al He Wire ends HU ft Ground strap Ena Remove ground A Yr strap and discard LS gt Zl Conduit connection plate A L d H H i 1 I FIGURE 12 Part4 INSTALL THE RANGE Replace the access cover on the range back To replace the wire cover insert double projections in the pockets located below the opening and tighten the three screws Use a spirit level to check your adjustments Place the level diagonally on the oven rack and check each direction for level 5 ANTI TIP DEVICE INSTALLATION A WARNING e DO NOT step or sit on oven A idee g kk e spirit level doesn t snow A door Install the Anti Tip level on the rack adjust the gt Bracket supplied with the AS Spirit level First check direction After check direction leveling legs with a wrench range The range could be tipped and 6 FINAL INSTALLATION X injury might result from spilled hot liquid food or the range itself e Move range close enough to the opening to plug If the range is pulled away from the into the receptacle wall for cleaning service or any Slide range into position insuring that the left back other reason ensure that the Anti leg slides under the anti tip bracket Range will sit 0 Tip Device is properly reengaged away from the back wall when prop
4. 1 Remove the lower 3 screws from the terminal block and retain them Refer to Figure 8 2 Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block Make sure that the center wire white neutral is connected to the center lower position of the terminal block 3 Tighten 3 screws securely into the terminal block Do not remove the ground strap connections 4 Go to page 9 Separate Strain Relief before installation Assemble the strain relief to the 17 5 opening in Conduit connection plate FIGURE 7 3 wire connection Black White Red Terminal Conduit connection plate FIGURE 8 Part3 ELECTRICAL CONNECTIONS 4 wire connection with a power supply cord 3 wire connection conduit Install the conduit as follows 4 WARNING a Remove the Conduit connection plate from the rear of e Only a 4 conductor power supply cord kit drawer body and rotate it as shown in Figure 5 The rated 120 240 volts 50 amperes and o marked for use with ranges with closed First prepare conduit wires as shown in Figure 10 loop connectors or open end spade lugs 3 wire 4 wire with upturned ends shall be used The middle neutral wire of the power cord or 4 wire conduit has to be connected to the middle post of the main terminal block The other two wires of the power cord or conduit have to be connected to the outside posts of the main te
5. LG Life s Good TONVdS4 INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range MODELS LRE30955S LSE3094S LRE30855S LRE30915 LRE307555 LSE3092S LRE30451S LSES302ST LRE307575 LSRE307ST LRE30453S P NO MFL57205802 www lg com rare METE 1 BEFORE YOU BEGIN Remove all tape and packing materials before using the range Dispose of all plastic bags after unpacking the range Never allow children to play with packing materials IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions before using your oven to prevent the risk of fire electric shock personal injury or damage when using the range This guide does not cover all possible conditions that may occur For further assistance contact your service agent or manufacturer A This is the safety alert symbol This symbol alerts you to potential hazards that can cause personal injury to you and others All safety messages will follow the safety alert symbol with either the word WARNING or CAUTION This symbol will alert you to hazards or unsafe practices which could cause serious A WARNING bodily harm or death This symbol will alert you to hazards or unsafe practices which could cause bodily A CAUTION injury or property damage 4 WARNING The information in this manual should be followed exactly A fire or electrical shock may result causing property damage personal injury
6. e phase 3 wire A C 120 208V or 120 240V 60Hz electrical system Use only a 3 conductor or a 4 conductor UL listed range cord with closed loop terminals open end spade lugs with upturned ends or similar terminations DO NOT install the power cord without a strain relief A range cord rated at 40 amps with 120 240 minimum volt range is required If a 50 amp range cord is used it should be marked for use with 138 diameter connection openings This appliance may be connected by means of conduit or power cord If conduit is being used go to page 7 3 wire conduit connections or page 8 for 4 wire conduit connections WARNING e New branch circuit installations 1996 NEC for mobile homes recreational vehicles and installations where local codes do not allow grounding through the neutral wire require a 4 conductor UL listed range cord or 4 wire conduit connection Specified power supply cord kit rating Diameter inches of Range connection Opening Conduit Range rating watts Specified rating of power supply 120 240 volts 120 208 volts cord kit amperes Power cord 3 wire 3 wire 8 750 16 500 7 801 12 500 40 or 50A 13 3 1 0 50 1 s 1 8 3 4 Wire electrical wall Receptacle e 4 Wire receptacle 14 50R 3 Wire receptacle 10 50R FIGURE 3 4 CONNECT RANGE CORD The Rear Access cover must be removed Loosen the three screws with a scre
7. erly installed when the range is pushed back e Carefully tip range forward to insure that the anti tip against the wall oo the range back brace and prevents e Turn on electrical power Check range for proper operation as described in owner s manual Anti tip bracket Screw must enter wood or concrete bam 1 Locate the bracket using the template An Anti tip bracket is packaged with template The If the counter does not bridge the opening at the rear instructions include necessary information to wall the rear filler kit that is provided with the slide in complete the installation range will be needed Read and follow range installation instruction sheet template NOTE If the countertop depth is greater than 25 there will be a gap between the filler kit and the back 2 Level the range Level the range by adjusting the leveling legs with a wrench wall If the countertop depth is less than 24 the control panel will not sit flush with the countertop See figure 1 on page 5 10 LG Life s Good To contact LG Electronics Para comunicarse con LG Electronics 24 hours a day 7 days a week 24 horas al dia 7 dias a la semana 1 800 243 0000 U S A 1 800 243 0000 EE UU Or visit us on the Web at www lg com O visitenos en la Web en www lg com Printed in Mexico
8. ll 4 CAUTION e Put on gloves during installation procedure Failure to do so can result in bodily injury NOTE e Read all instructions contained in these installation instructions before installing range e Remove all packing materials from the oven compartments before connecting the electrical supply to the range e Observe all governing codes and ordinances Be sure to leave these instructions with the consumer NOTE Keep these instructions with your owner s manual for future reference As when using any appliance generating heat there are certain safety precautions you should follow Be sure your range is installed and grounded properly by a qualified installer or service technician Make sure the wall coverings around the range can withstand the heat generated by the range e To eliminate the need to reach over the surface elements cabinet storage space above the elements should be avoided PREPARE TO INSTALL THE RANGE TOOLS NEEDED a Phillips Screwdriver Mi Flat blade Screwdriver ES 1 4 Nut Driver SL Pliers Oh Tape Measure Safety Glasses da Pencil Gloves PARTS PROVIDED Template Anti Tip Bracket Kit aye Rear filler amp 2 Screws LSE Series only ARS Nun Anchor Sleeves Lag Bolts For Anti Tip Bracket Mounted on Concrete Floors and Walls PARTS NOT PROVIDED Strain Relief For Conduit Installations Only UL Ap
9. nter lower Do not remove ground strap connections position of the terminal block 3 Insert the two side bare wire ends into the lower left Tighten 3 screws securely into the terminal block and the lower right terminal block opening 5 Go to page 9 Tighten the 3 screws securely into the terminal block approximately 35 50 IN LB 4 wire connection 4 Go to page 9 Black White Red 3 wire connection Terminal Black White Red y E Terminal Ground strap Remove ground strap and discard Groun sorew Conduit connection plate Conduit connection plate FIGURE 9 FIGURE 11 Part3 ELECTRICAL CONNECTIONS Follow the instructions under Install the conduit as follows on page 7 to correctly install the strain relief DO NOT install the conduit without a strain relief Loosen the 2 lower left and right screws from the terminal block Refer to Figure 12 Remove the lower 2 center screws Remove ground strap and discard as shown in Figure 12 Do not discard any screws Attach the ground bare wire end to range frame and secure it in place with the ground screw Refer to figure 12 Insert the bare wire white neutral end through the center terminal block opening Insert the two side bare wire ends into the left and the right terminal block opening Tighten the 3 screws securely into the terminal block approximately 35 50 IN LB Go to page 9 4 wire
10. or death e DO NOT step or sit on oven door Install the Anti Tip Bracket supplied with the range The range could be tipped and injury might result from spilled hot liquid food or the range itself If the range is pulled away from the wall for cleaning service or any other reason ensure that the Anti Tip Device is properly reengaged when the range is pushed back against the wall e New branch circuit installations 1996 NEC for mobile homes recreational vehicles and installations where local codes do not allow grounding through the neutral wire require a 4 conductor UL listed range cord or 4 wire conduit connection e The middle neutral or ground wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block Failure to do so can result in electrical shock severe personal injury or death e Only a 4 conductor power supply cord kit rated 120 240 volts 50 amperes and marked for use with ranges with closed loop connectors or open end spade lugs with upturned ends shall be used The middle neutral wire of the power cord or 4 wire conduit has to be connected to the middle post of the main terminal block The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block The 4th ground wire mu
11. proved 40 or 50 AMP 4 Wire Cord OR 3 Wire Cord Part2 PREPARE TO INSTALL THE RANGE 2 INSTALLATION DRAWINGS LRE LSRE Series only NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR CLEARANCES AND DIMENSIONS Figure 1 To install range refer to the following Figure 1 For installation in CANADA a Free standing range is not to be installed closer than 15 32 12mm from any adjacent surface 4 CAUTION 4 CAUTION e Make sure that the wall covering e Cabinet storage space located above countertop and cabinets around the the surface units should be avoided range can withstand the heat up to e Install a range hood that projects 194 F generated by the range horizontally a minimum of 5 inches Discoloration delamination or melting may occur beyond the bottom of the cabinets If This range has been designed to comply with the cabinet storage is to be provided of 194 F heated surface elements can be reduced 3 7 6cm A D 3 7 6cm 5 Normal 1 2 r 63 5cm counter Acceptable Ey top depth electrical outlet area 30 _ 76 2cm 30 76 2cm Minimum 4 6 15 20mn 36 Counter 15 A i 38 1cm lt 24 60 9cm 36 x 91 4cm j 30 76 2cm A 30 76 2 cm For U S A 30 76 2 cm 31 78 7 cm For CANADA FIGURE 1 FIGURE 2 MINIMUM DIMENSIONS Figure 2
12. rminal connection block The 4th ground wire must be connected to the frame of the range with the ground screw FIGURE 10 Failure to do so can result in electrical shock severe Second install conduit as shown in Figure 6 personal injury or death T Pid 3ye 2 5em 0 9 cm 2 5cm 0 9 cm Conduit 31 2 connection 8 9 cm plate For conduit installations after purchasing a strain Follow the instructions under 4 CONNECT RANGE relief insert it in the conduit hole 1 s Then install CORD on page 5 to correctly install the strain relief the conduit through the body of strain relief and i fasten the strain relief with its ring Reinstall the 1 Remove the lower 3 screws from the terminal block bracket and retain them Refer to Figure 9 Remove the ground screw and retain it ld ed ra 2 Remove ground strap and discard as shown ie ane A IA RP IO eer in Figure 9 If the wire in the conduit is aluminum it must be 6 or 8 Do not discard any screws AWG wiring 3 Insert the ground screw into the power cord ground wire terminal ring and secure it to the range frame 1 Loosen the lower 3 screws from the terminal block 4 Insert the 3 screws through each power cord Pareri igure 1a terminal ring and into the lower terminals of the 2 Insert the bare wire white neutral end through the terminal block Make sure that the center wire center terminal block opening l white neutral is connected to the ce
13. st be connected to the frame of the range with the ground screw Failure to do so can result in electrical shock severe personal injury or death 4 CAUTION e Put on gloves during installation procedure Failure to do so can result in bodily injury e Make sure that the wall covering countertop and cabinets around the range can withstand the heat up to 194 F generated by the range Discoloration delamination or melting may occur This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 F e Cabinet storage space located above the surface units should be avoided e Install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets If cabinet storage is to be provided The risk of burns or fire by reaching over the heated surface elements can be reduced 4 WARNING e The information in this manual should be followed exactly A fire or electrical shock may result causing property damage personal injury or death 4 WARNING e DO NOT step or sit on oven door Install the Anti Tip Bracket supplied with the range The range could be tipped and injury might result from spilled hot liquid food or the range itself If the range is pulled away from the wall for cleaning service or any other reason ensure that the Anti Tip Device is properly reengaged when the range is pushed back against the wa
14. wdriver The terminal block will then be accessible E Drawer body Cord Conduit Drawer body cover connection plate LSE series only FIGURE 4 The Cord Conduit connection plate is used for the installation of power cord or conduit For power cord install it with the connection plate as INSTALLED For conduit remove the connection plate located below the rear of the drawer body and use the conduit hole 1 s instead of power cord hole 13 e Refer to Figure 5 and 6 11 8 Conduit 3 5 cm Remove the Conduit connection plate Cord Conduit connection Strain relief Conduit Assemble the strain relief hole Strain relief Reinstall the Cord Conduit connection plate FIGURE 6 Part3 ELECTRICAL CONNECTIONS A WARNING e The middle neutral or ground wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block Failure to do so can result in electrical shock severe personal injury or death Install the power cord as follows For power cord installations Hook the strain relief over the power cord hole 1 e located below the rear of drawer body Insert the power cord through the strain relief and tighten it Refer to Figure 7 DO NOT install the power cord without a strain relief