LG LRE30451S User's Manual
Contents
1. LG Website http us lge com installation Manual Electric Range LRE30451S LRE30755S Please read these instructions thoroughly before installing and operating the range P No 3828W5U0512 rare METE 1 BEFORE YOU BEGIN Remove all tape and packing materials before using the range Dispose all plastic bags after unpacking the range Never allow children to play with packing materials IMPORTANT SAFETY INSTRUCTIONS A WARNING Ifthe information in this manual is not followed exactly a fire or electrical shock may result causing property damage personal injury or death E A Important Notes to the Installer Read all instructions contained in these installation instructions before installing range e Remove all packing materials from the oven compartments before connecting the electrical supply to the range e Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions with your owner s manual for future reference As when using any appliance generating heat there are certain safety precautions you should follow Be sure your range is installed and grounded properly by a qualified installer or service technician Make sure the wall coverings around the range can withstand the heat generated by the range To eliminate the need to reach over the surface elements cabinet storage space above the
2. 508 mm de cobre 15 38 1 cm como m nimo entre la cubierta de los gabinetes y la parte inferior del gabinete adyacente Secci n 3 3 REQUISITOS DE LAS CONEXIONES EL CTRICAS Este artefacto deber instalarse y conectarse a tierra en un circuito de red por un t cnico certificado de acuerdo con la edici n m s reciente del c digo de la National Electrical code ANSI NFPA NO 70 Todo el alambrado deber conformarse a Local y NEC Esta estufa requiere de un sistema el ctrico monof sico de 3 alambres 120 208 V C A o 120 240 V 60Hz Use solamente un cable de 3 o 4 alambres para estufa reconocido por la UL con terminales de ojillo cerrado leng etas de pala con extremos doblados o terminales parecidas El cable deber tener un tensor de alivio montado correctamente Es necesario un cable para estufa con capacidad nominal de 120 240 V a 40 amps Si se llegara a usar un cable de estufa de 50 amps deber estar marcado como para ser utilizado en aberturas de conexi n de 13 8 3 5 cm de di metro Este artefacto puede conectarse usando un conductor de cable o cable de alimentaci n Si se utilizan conductos portacables consulte la p gina 6 Conexiones de conductos portacables con 3 alambres O la p gina 7 para las conexiones de conductos portacables con 4 conductores A ADVERTENCIA Todas las instalaciones de red nuevas 1996 NEC remolques veh culos recreativos e instalaciones donde los c digos loca
3. 7777 Cut and 8 Attach the lug with red wire L1 to the right f 4 discard terminal block bolt 9 Tighten 3 nuts removed earlier securely into the Games cara 4 wire connection gt Conduit terminal block and washer connection plate 10 Go to page 8 FIGURE 13 Part4 INSTALL THE RANGE Replace the access cover on the range back To replace the wire cover insert double projections in the pockets located below the opening and tighten the three screws 5 ANTI TIP DEVICE INSTALLATION A WARNING e To reduce the risk of tipping the appliance must be secured by properly installed anti tip devices packed with the appliance e See instructions to install supplied with bracket e Unless properly installed the range could be tipped by stepping or sitting on the door Injury may result from spilled hot liquids or from the range itself Screw must enter wood approximately p or concrete 0 65 16 5mm Anti tip bracket Note To install Anti tip bracket release the leveling leg A minimum clearance of 0 65 16 5mm is required between the range bottom and the kitchen floor 1 Locate the bracket using the template An Anti tip bracket is packaged with template The instructions include necessary information to complete the installation Read and follow range installation instruction sheet template 2 Level the range Level
4. firmemente las 3 tuercas que retir JA de apriete 20 IN LB anteriormente al bloque de terminales PRA 25 IN LB E Paar ambre A 7 Dir jase a la p gina 8 desnudo Sl ler FIGURA 11 Conexion de 4 alambres Conexi n de 3 alambres conducto portacables Negro Blanco Rojo A Lote p f Bloque de 1 Para instalar correctamente el tensor de alivio siga E terminales las instrucciones Instale el cable de alimentaci n como sigue en la p gina 6 El conducto portacables deber instalarse con un tensor de alivio 2 Corte la parte central de la cinta de tierra como se muestra en la figura 13 No deseche los tornillos Si usa alambre desnudo conecte con adaptadores Placa de conexi n de orejetas como se muestra en las Figuras 11 y 13 de conductos portacables 3 Inserte el extremo del alambre verde tierra del conducto portacables en la orejeta y apriete el tornillo de apriete Afiance la orejeta al orificio GND debajo del bloque de terminales con el tornillo Conexi n de 4 alambres de tierra que retir anteriormente 4 Inserte el extremo de cada alambre L1 L2 Neutral en FIGURA 12 Negro Blanco Rojo cada orejeta separada Apriete el tornillo de apriete gt Pogue de 5 Quita las 3 tuercas del bloque de terminales 4 AVE Orejeta Quite el tornillo de tierra y gu rdelo adaptadora 6 Afiance la orejeta con el alambre blanco Neutral al AN
5. Cinta perno central del bloque de terminales SIN d de tierra 7 Afiance la orejeta con el alambre negro L2 al J dl ek perno izquierdo del bloque de terminales 8 Afiance la orejeta con el alambre rojo L1 al perno recho del bloque de terminales Tornillo de tierra Placa de conexi n de j q H i y arandela de conductos portacables 9 Apriete las 3 tuercas que retir anteriormente firmemente al bloque de terminales FIGURA 13 10 Dir jase a la p gina 8 Secci n 4 Reponga la cubierta de acceso en la parte posterior de la estufa Para reponer la cubierta de alambre inserte las salientes dobles en las cavidades ubicadas debajo de la abertura y apriete los tres tornillos Cubierta de acceso 5 INSTALACI N DEL DISPOSITIVO ANTI VOLCADURAS A ADVERTENCIA e Con el fin de reducir el riesgo de volcaduras el artefacto deber asegurarse usando los dispositivos anti volcaduras provistos junto con el artefacto e Consulte las instrucciones para la instalaci n provistas con la m nsula e Si no se instal correctamente la estufa podr a volcarse si se pisa o se sienta en la puerta Podr an producirse lesiones por el derrame de l quidos calientes o por la estufa misma El tornillo debe introducirse en la madera o en el concreto M nsula aproximadamente p anti volcaduras 0 65 16 5 mm 4i Nota Para la instalaci n de la m nsula anti volcaduras libere la pa
6. a BARE WIRE TORQUE SPECIFICATIONS 5 Attach the lug with red wire L1 to the right terminal 5 LUG ATTACHED TO TERMINAL BLOCK 6 Tighten 3 nuts removed earlier securely onto the Lug A S E terminal block l Stripped wire 8 25 IN LB 7 Go to page 8 4 6 35 IN LB FIGURE 11 4 wire connection conduit 3 wire connection Black White Red Follow the instructions under Install the conduit HI Termin l cord as follows on page 6 to correctly install the IE LESA block DANAN strain relief Ada a z pter You must install the conduit with a strain o Ie gt lug relief lol 2 Cut the center portion of ground strap as shown Figure 13 Do not discard any screws If bare wire is used connect with adapter lugs as shown in Figures 11 and 13 Cone c gie 3 Insert the end of green wire ground from conduit into the lug and tighten the clamping screw Attach FIGURE 12 the lug to the GND hole below terminal block with ground screw removed earlier Insert the end of each wire L1 L2 Neutral into each separate lug Tighten the clamping screw Black White Red 5 Remove the 3 nuts from the terminal block 5 Terminal Remove the ground screw and retain them 7 Eyer block 6 Attach the lug with white wire Neutral to the ARA WA P Adapter center terminal block bolt SL gt lug Cai 7 Attach the lug with black wire L2 to the left E 1 strap terminal block bolt
7. ales y gu rdelas Consulte la Figura 6 Afiance los 3 alambres L1 Neutral L2 a cada perno del bloque de terminales Cerci rese de que el alambre central neutral se conecta al poste central del bloque de terminales Apriete las 3 tuercas firmemente al bloque de terminales No quite la conexi n de la cinta de conexi n a tierra Dir jase a la p gina 8 Conexi n de 4 alambres con un cable de alimentaci n A ADVERTENCIA Use solamente un cable de alimentaci n de 4 alambres con capacidad nominal de 120 240 voltios 50 amperios y marcado para ser utilizado en una estufa con terminales de ojillo cerrado o leng etas de pala con extremos doblados El cable central neutro o tierra del cable de alimentaci n o conducto portacables de 4 alambres debe conectarse al poste central del bloque de terminales principal Los dos alambres restantes del cable de alimentaci n o conducto portacables deber n conectarse a los postes externos del bloque de terminales principal El 4 alambre de tierra deber conectarse al marco de la estufa usando el tornillo de tierra Conexi n de 3 alambres Negro Blanco Rojo Bloque de terminales Placa de conexi n para conectar a conductos portacables FIGURA 6 Conexi n de 4 alambres Negro Blanco Rojo Bloque de terminales Cinta de tierra Tornillo de tierra Placa de conexi n para conectar y arandela a conductos portacables Para ins
8. block bolts Be certain that the center wire white neutral is connected to the center position of the terminal block Tighten the 3 nuts securely onto the terminal block 5 Go to page 8 Install the conduit as follows 13 8 Remove the Conduit connection plate from the rear of drawer body and rotate it as shown in Figure 8 The conduit hole 1 e must be used First prepare conduit cord as shown in Figure 9 3 wire 4 wire 1 3j 1 ola 2 5cm 0 9 cm 2 5cm 0 9 cm Conduit connection Knockout 31 2 31 2 suface 8 9 cm 8 9 cm FIGURE 9 Second install conduit cord as shown in Figure 10 For conduit installations after purchasing a strain QZ relief insert it in the conduit hole 1 s Then install VA Assemble the the conduit cord through the body of strain relief and strain relief hole fasten the strain relief with its ring Reinstall the bracket FIGURE 10 Part3 ELECTRICAL CONNECTIONS Third connect the wires If bare wire is used connect with adapter lugs as shown in Figures 11 and 12 1 Insert the end of each wire L1 L2 Neutral into the each lug Tighten the clamping screw o relle 2 Remove the 3 nuts from the terminal block and retain them 3 Attach the lug with white wire Neutral to the center Reinstall the terminal block bolt Conduit connection plate 4 Attach the lug with black wire L2 to the left terimnal block bolt i i
9. e 1 2 31 2 removible 8 9 cm 8 9 cm Conducto FIGURA 9 O portacables Ensamble el orificio Seguidamente instale el cable del conducto del tensor de alivio portacables tal como se muestra en la figura 10 FIGURA 10 Para las instalaciones de conducto portacables compre un tensor de alivio e ins rtelo en el orificio del conducto portacables 1 2 9 cm Luego instale el cable del conducto portacables por el cuerpo del tensor de alivio y afiance el tensor de alivio usando su anillo Vuelva a instalar la m nsula SEA CONEXIONES EL CTRICAS En tercer lugar conecte los alambres Si usa alambre desnudo conecte con adaptadores de orejetas como se muestra en las Figuras 11 y 12 1 Inserte el extremo de cada alambre L1 L2 Neutral en cada orejeta Apriete los tornillos de apriete 2 Quite las 3 tuercas del bloque de terminales y gu rdelas 3 Afiance la orejeta con el alambre blanco Neutral al Vuelva a instalar la placa de conexi n para perno central del bloque de terminales conectar a conductos portacables 4 Afiance la orejeta con el alambre negro L2 al perno ESPECIFICACIONES DELPARDE izquierdo del bloque de terminales TORSI N DEL ALAMBRE DESNUDO A z OREJETA AFIANZADA AL BLOQUE DE 5 Afiance la orejeta con el alambre rojo L1 al perno TERMINALES 20 IN LB de alivio derecho del bloque de terminales Tornillo ALAMBRE CALIBRE AWG PAR DE TORSI N 6 Apriete
10. elements should be avoided A WARNING ALL RANGES CAN TIP e INJURY TO PERSONS COULD RESULT e INSTALL ANTI TIP BRACKET PACKED WITH RANGE e SEE INSTALLATION INSTRUCTIONS PREPARE TO INSTALL THE RANGE TOOLS NEEDED Tr Phillips Screwdriver Flat blade Screwdriver Es 3 8 Nut Driver AAA Pliers PARTS PROVIDED Template Anti Tip Bracket Kit For conduit connection wo Anchor Sleeves Lag Bolts For Anti Tip Bracket Mounted on Concrete Floors Only PARTS NOT PROVIDED Strain Relief For Conduit Installations Only UL Approved 40 or 50 AMP 4 Wire Cord OR 3 Wire Cord Part2 PREPARE TO INSTALL THE RANGE 2 INSTALLATION DRAWINGS IMPORTANT SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR CLEARANCES AND DIMENSIONS Figure 1 To install range refer to the following Figure 1 For installation in CANADA a Free standing range is not to be installed closer than 12 mm from any adjacent surface CAUTION This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 F Make sure the wall covering countertop and cabinets around the range can withstand the heat up to 194 F generated by the range If not discoloration delamination or melting may occur 3 7 6cm 3 7 6cm 25 Norma 63 5cm counter Acceptable E top depth electrical 1 outlet area i 1 36 y 0 15 2cm y 15 2cm NI ae e ma he
11. i metro en pulgadas de la abertura de conexi n de la estufa 120 240 voltios 120 208 voltios Juego de cable de alimentaci n Cable de 3 alambres 3 alambres Conducto alimentaci n portacables amperios 8 750 16 500 7 801 12 500 40 o 50A 1 8 1 8 50 1 8 1 8 SEA CONEXIONES EL CTRICAS Conexi n de 3 alambres con un cable de alimentaci n A ADVERTENCIA El cable central neutro o tierra del cable de alimentaci n o conducto portacables de 3 alambres debe conectarse al poste central del bloque de terminales principal Los dos alambres restantes del cable de alimentaci n o conducto portacables de 3 alambres deber n conectarse a los postes externos del bloque de terminales principal Placa de conexi n para conectar a conductos portacables Instale el cable de alimentaci n como sigue Para las instalaciones del cable de alimentaci n enganche el tensor de alivio al orificio del cable de alimentaci n 1 s 3 5 cm ubicado debajo de la parte posterior del cuerpo del caj n Inserte el cable de alimentaci n a trav s del tensor de alivio y apri telo Consulte la Figura 5 Afiance el tensor de alivio Al orificio de 1 3 5 cm en la Cable de alimentaci n placa del conducto portacables FIGURA 5 El cable de alimentaci n deber instalarse con un tensor de alivio 1 Quite las 3 tuercas del bloque de termin
12. ide que la estufa se vuelque Encienda la alimentaci n de energ a el ctrica Verifique que la estufa est orientada correctamente tal como se describe en el manual del propietario
13. ight E DIS Cabinet ol e 3 24 60 9cm 36 x 91 4cm pe 30 76 2cm A 30 76 2 cm For U S A 30 76 2 cm 31 78 7 cm For CANADA FIGURE 1 MINIMUM DIMENSIONS Figure 2 IMPORTANT To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoided If cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets 30 _ 76 2cm 30 76 2cm Minimum FIGURE 2 30 76 2 cm minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or 24 60 9 cm minimum when bottom of wood or metal cabinet is protected by not less than 1 4 6 4 cm flame retardant millboard covered with not less than no 28 MSG sheet steel 0 015 0 381 mm stainless steel 0 024 0 610 mm aluminum or 0 020 0 508 mm copper 15 38 1 cm minimum between countertop and adjacent cabinet bottom Part3 ELECTRICAL CONNECTIONS 3 ELECTRICAL CONNECTION REQUIREMENTS This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI NFPA NO 70 latest edition All wiring should confor
14. les no permiten la conexi n a tierra por el neutro requieren un cable de 4 alambres reconocido por la UL o conexi n a conductos portacables de 4 alambres 4 C MO CONECTAR EL CABLE DE LA ESTUFA Debe quitarse la cubierta de acceso posterior Use un destornillador para aflojar los tres tornillos Entonces se podr tener acceso a un bloque de terminales CONEXIONES EL CTRICAS 3 Tipos de tomacorriente de pared de 4 alambres vje x Tomacorriente de jw 4 alambres 14 50R e U e Y Q Tomacorriente de x 3 alambres 10 50R FIGURA 3 Para la instalaci n del cable de alimentaci n o de conducto portacables se deben usar placas de conexi n para conectar a conductos portacables El cable de alimentaci n deber instalarse con la placa de conexi n de conductos portacables provista por el fabricante En el caso de conductos portacables quite la placa de conexi n de conductos portacables que est ubicada debajo de la parte posterior del cuerpo del caj n y use el orificio del conducto portacables 1 2 8 cm en lugar del orificio del cable de alimentaci n 1 e 3 5 cm Consulte la Figura 8 macorriente de cable alimentaci n Placa de conexi n para conectar Cuerpo del caj n 4 conductos portacables FIGURA 4 Clasificaci n nominal especificada para el juego del cable de alimentaci n Clasificaci n nominal especificada para Capacidad nominal de la estufa Vatios D
15. m to Local and NEC This range requires a single phase 3 wire A C 120 208V or 120 240V 60Hz electrical system Use only a 3 conductor or a 4 conductor UL listed range cord with closed loop terminals open end spade lugs with upturned ends or similar terminations Cord must have the strain relief properly installed A range cord rated at 40 amps with 120 240 minimum volt range is required If a 50 amp range cord is used it should be marked for use with 138 diameter connection openings This appliance may be connected by means of conduit or power cord If conduit is being used go to page 6 3 wire conduit connections or page 7 for 4 wire conduit connections A WARNING New branch circuit installations 1996 NEC mobile homes recreational vehicles and installations where local codes do not allow grounding through neutral require a 4 conductor UL listed range cord or 4 wire conduit connection 4 CONNECT RANGE CORD The Rear Access cover must be removed Loosen the three screws with a screwdriver The terminal block will then be accessible 3 4 Wire electrical wall Receptacle types gt G Mi Sp 4 Wire receptacle 14 50R wi i ANS o u 3 Wire receptacle 10 50R FIGURE 3 Conduit connection plate is used for the installation of power cord or conduit For power cord install it with conduit connection plate as manufacturer supplied For conduit cord remove the conduit connection plate l
16. mentos de cocci n PREPARATIVOS PARA INSTALAR LA ESTUFA HERRAMIENTAS NECESARIAS Moa Destornillador Phillips Or Destornillador de hoja plana ER Llave de caja de 3 8 e ee LR Alicates Taladro PIEZAS PROVISTAS SY Orejeta Para conexi n de conducto xo Pernos de fijaci n Plantilla Juego de m nsula anti volcaduras S Manguitos de anclaje Solamente cuando se instala la m nsula de anti volcadura en pisos de concreto PIEZAS NO PROVISTAS Aprobado por la UL para 40 0 50 AMPS Cable de 4 alambres o de 3 alambres Tensor de alivio Solamente para instalaciones con conducto portacables PREPARATIVOS PARA INSTALAR LA ESTUFA 2 ILUSTRACIONES DE INSTALACI N IMPORTANTE GU RDELO PARA EL USO DEL INSPECTOR LOCAL DE INSTALACIONES EL CTRICAS HOLGURAS Y DIMENSIONES Figura 1 Consulte la figura 1 a continuaci n para la instalaci n de la estufa Si se va a instalar en CANADA una estufa aut noma no podr instalarse a menos de 12 mm de cualquier superficie adyacente PRECAUCI N Esta estufa ha sido dise ada para cumplir con las temperaturas m ximas permitidas para gabinetes de madera es decir 194 F 90 C Cerci rese de que los recubrimientos de la pared cubierta y gabinetes alrededor de la estufa pueden resistir la temperatura generada por la estufa 194 F 90 C De lo contrario podr a presentarse decoloraci n derretimient
17. nal 3 wire connection block bolt Make sure that the center wire neutral Black White Red is connected to the center position of the terminal f Terminal block 3 Tighten the 3 nuts securely into the terminal block Do not remove the ground strap connection 4 Go to page 8 Conduit connection plate A WARNING FIGURE 6 Only a 4 conductor power supply cord kit rated 120 240 volts 50 amperes and marked for use with 4 wire connection ranges with closed loop connectors open end spade Black White Red lugs with upturned ends shall be used The middle neutral wire of the power cord or 4 wire conduit has to be connected to the middle post of the main terminal block Other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block The 4th ground wire must be connected to the frame of the range with the ground screw Follow the instructions under Install the power cord Ground screw Conduit as follows on page 5 to correctly install the strain and washer connection plate relief FIGURE 7 Part3 ELECTRICAL CONNECTIONS Remove the 3 nuts from the terminal block Refer to Figure 7 Remove the ground screw and washer retain them 2 Cut the center portion of ground strap as shown Figure 7 Do not discard any screws 3 Attach the ground wire with the ground screw and washer Attach the 3 wires L1 Neutral L2 to the correct terminal
18. nual puede ocasionar incendios o sacudidas el ctricas que podr an causar da os a la propiedad lesiones personales o la muerte A ADVERTENCIA e TODAS LAS ESTUFAS PUEDEN VOLCARSE AQ ALGUNAS PERSONAS PODR AN RESULTAR LESIONADAS KA e SE DEBE INSTALAR LA MENSULA ANTI VOLCADURAS PROVISTA PS JUNTO CON LA ESTUFA SY CONSULTE LAS INSTRUCCIONES DE INSTALACI N Notas importantes para el instalador Antes de instalar la estufa lea todas las instrucciones incluidas en estas instrucciones de instalaci n Antes de conectar la fuente de alimentaci n el ctrica debe quitar todos los materiales de empaque del compartimiento del horno e Cumpla con todos los c digos y ordenanzas vigentes e Siempre deje estas instrucciones con el consumidor Notas importantes para el consumidor Conserve estas instrucciones junto con su manual del propietario para cualquier consulta en el futuro Al igual que cuando se utiliza cualquier artefacto que genera calor deben seguirse ciertas precauciones de seguridad Cerci rese de que su estufa sea instalada y conectada a tierra correctamente por un instalador o t cnico de servicio calificado Cerci rese de que todos los adornos o recubrimientos de la pared que est n alrededor de la estufa tienen la capacidad de resistir el calor generado por la misma Se debe evitar el uso de gabinetes de almacenamiento encima de la estufa para no tener que alcanzarlos por encima de los ele
19. o o delaminaci n IMPORTANTE Para eliminar los riesgos de quemaduras o incendios cuando se trata de alcanzar algo por encima de unidades con superficies calientes debe evitarse disponer de gabinetes de almacenamiento por encima de las unidades de superficie Si se han provisto gabinetes de almacenamiento puede reducirse el riesgo si se instala una campana de estufa que sobresalga un m nimo de 5 pulgadas 12 cm de la parte inferior de los gabinetes 3 7 6cm a O 24 3 7 6cm 25 Fondo 1 63 5cm normal de la cubierta gt tomacorrientes 30 gt el ctricos _ 76 2cm 30 76 2cm Minimo y E NI ee et dem alee 3 i E A IM F E S Abertura de los gabinetes 24 60 9cm 36 ra 91 4cm pe 30 76 2cm A 30 76 2 cm Para EE UU 30 76 2 cm 31 78 7 cm Para CANADA FIGURA 1 FIGURA 2 DIMENSIONES M NIMAS Figura 2 30 76 2 cm de holgura m nima entre la cubierta de la superficie de cocci n y la base de un gabinete de madera o de metal sin protecci n o 24 60 9 cm como m nimo cuando la parte inferior de un gabinete de madera o de metal est protegida por una capa de 1 4 6 4 mm de cart n gris resistente al fuego y recubierta cuando menos con l mina de acero no 28 MSG 0 015 0 381 mm de acero inoxidable 0 024 0 610 mm de aluminio o 0 020 0
20. ocated below the rear of the drawer body and use the conduit hole 1 s instead of power cord hole 1 Refer to Figure 8 Conduit connection plate Drawer body FIGURE 4 Specified power supply cord kit rating Diameter inches of Range Range rating watts J 9 connection Opening Specified rating of power supply 120 240 volts 120 208 volts cord kit amperes Power cord 3 wire 3 wire Conduit 8 750 16 500 7 801 12 500 40 or 50A 1 8 1 8 50 V s 1 8 Part3 ELECTRICAL CONNECTIONS A WARNING The middle neutral or ground wire of the power cord or 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block Conduit connection Install the power cord as follows For power cord installations Hook the strain relief over the power cord hole 1 e located below the rear of drawer body Insert the power cord through the strain relief and tighten it Refer to Figure 5 Attach the strain relief to the 17 4 opening in Power cord Conduit connection plate You must install the power cord with a strain relief 1 Remove the 3 nuts from the terminal block and FIGURE 5 retain them Refer to Figure 6 2 Attach the 3 wires L1 Neutral L2 to each termi
21. ta niveladora Se necesita una holgura de 0 65 16 5 mm entre el fondo de la estufa y el piso de la cocina 1 Ubique la m nsula utilizando la plantilla La plantilla viene empacada con cada m nsula anti volcaduras Las instrucciones incluyen la informaci n necesaria para llevar a buen t rmino la instalaci n Lea y obedezca el contenido de la hoja de instrucciones plantilla de la estufa 2 Nivele la estufa Nivele la estufa ajustando las patas niveladoras con una llave de tuercas C MO INSTALAR LA ESTUFA Nivelador de patas Eleve la estufa Utilice un nivel de burbuja para verificar sus ajustes Coloque el nivel en la parrilla del horno de la estufa en forma diagonal y verifique el nivel en cada direcci n Primero verifique la direcci n Nivel de burbuja Despu s verifique la direcci n Si el nivel de burbuja no muestra que la parrilla est nivelada ajuste las patas niveladoras con una llave de tuercas 6 INSTALACI N FINAL e Acerque la estufa lo suficiente a la abertura para poder enchufarla en el tomacorriente e Acomode la estufa en su puesto cerciorandose de que la pata posterior izquierda se desliza debajo de la m nsula anti volcaduras Una vez que est instalada correctamente la estufa quedar a 0 de distancia de la pared trasera e Con cuidado incline la estufa hacia adelante para comprobar que la m nsula anti volcaduras engancha con el tirante posterior de la estufa e imp
22. talar correctamente el tensor de alivio siga las instrucciones Instale el cable de alimentaci n como sigue en la p gina 5 FIGURA 7 CONEXIONES EL CTRICAS Quite las 3 tuercas del bloque de terminales Consulte la Figura 7 Quite el tornillo de tierra y la arandela y gu rdelos 2 Corte la parte central de la cinta de tierra como se muestra en la figura 7 No deseche los tornillos 3 Afiance el alambre de tierra con el tronillo de tierra y la arandela Afiance los 3 alambres L1 Neutral L2 al perno del bloque de terminales correspondiente Cerci rese de que el alambre central blanco neutral se conecta al poste central del bloque de terminales Apriete las 3 tuercas firmemente al bloque de terminales p 5 Dir jase a la p gina 8 Conexi n de 3 alambres conducto portacables 13 8 Instale el conducto portacables de la manera siguiente 11 8 Quite la placa de conexi n de conductos portacables de la parte posterior del cuerpo del caj n y d le vuelta Quite la placa de conexi n como se muestra en la figura 8 Debe usarse el orificio de conductos portacables de conducto portacables 1 s 3 cm FIGURA 8 Primero prepare el cable del conducto portacables tal como se muestra en la figura 9 j j Placa de conexi n 3 alambres 4 alambres a IE para conectar ONF a conductos portacables 1 3 8 1 3 8 2 5cm 0 9 cm 2 5cm 0 9 cm Superfici
23. the range by adjusting the leveling legs with a wrench leveler Raise range Use a spirit level to check your adjustments Place the level diagonally on the oven rack and check each direction for level Spirit level First check direction After check direction If the spirit level doesn t show level on the rack adjust the leveling legs with a wrench 6 FINAL INSTALLATION e Move range close enough to the opening to plug into the receptacle e Slide range into position insuring that the left back leg slides under the anti tip bracket Range will sit 0 away from the back wall when properly installed e Carefully tip range forward to insure that the anti tip bracket engages the range back brace and prevents tip over e Turn on electrical power Check range for proper operation as described in owner s manual Sitio Web http us lge com Manual de instalaci n Estufa el ctrica LRE30451S LRE30755S Sirvase leer cuidadosamente estas instrucciones antes de instalar y poner a funcionar la estufa Numero de pieza 3828W5U0512 SEGURIDAD 1 ANTES DE COMENZAR Antes de usar la estufa quite todas las cintas y materiales de empaque Despu s de desempacar la estufa deseche todas las bolsas de pl stico Nunca permita que los ni os jueguen con los materiales de empaque INSTRUCCIONES DE SEGURIDAD MUY IMPORTANTES A ADVERTENCIA El no seguir exactamente las instrucciones de este ma
Download Pdf Manuals
Related Search
Related Contents
VRMMOをするのです。 American DJ Ruby Star User's Manual CORRESPONDENCIAS ENTRE CIE-10 Y CIE Intel R1208WTTGS server barebone Safety Network Controller serie NE1A: NE1A-SCPU01 User`s Manual Manuel d`instructions Manual del usario Manuale dell Honeywell RCH9300WF Instructions / Assembly Garmin dezl 770LMTHD Owner's Manual Copyright © All rights reserved.