Home
LevelOne IFE-0501 User's Manual
Contents
1. LevelOne IFE 0501 IFE 0502 4 Port PoE 1 Port SC Industrial Fast Ethernet Switch User Manual Ver 1 0 0 0711 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures B Reorient or relocate the receiving antenna B increase the separation between the equipment and receiver B Connectthe equipment into an outlet on a circuit different from that to which the receiver is connected B Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures INTRODUCTION cie eee
2. 2 TD Straight Through Cable Schematic switch Switch 3 TD 3 TD 6 TD 6 TD RD 1 RD 2 RD 2 RD Cross Over Cable Schematic B Fiber Port The fiber port of SC type connector can work in multi mode 2Km or single mode 30Km When you connect the fiber port to another one please follow the figure below to connect accordingly Wrong connection will cause the port cannot work normally SC Connector Tx Cable Wirlng SC to SC Tx A A Tx B B Rx ATTENTION This is a Class 1 Laser LED product N Don t stare into the Laser LED Beam 10 Cabling B Twisted pair segment can be connected with unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Fiber segment using single mode connector type must use 9 125 single mode fiber cable Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable Wiring the Power Inputs Please follow the steps below to insert the power wire Insert the positive and negative wires into the V and V contacts on the terminal block connector Tighten the wire clamp screws for preventing the wires from loosing 12 Wiring the Fault Alarm Contact The fault alar
3. e g Switch PC or Server The UTP STP port RJ 45 LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication 7 When all connections are set and LED lights all show in normal the installation is complete 17 Network Application This segment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the figure below T 5 I Control center Fiber Cable IFE 0501 IFE 0502 EI lt i IP Camera Wireless AP 18 Troubleshooting Verify that is using the right power cord adapter DC 48V please don t use the power adapter with DC output voltage higher than 48V or it will burn this equipment down B Select the proper UTP STP cable to construct your network Please check that is using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps connections 1000 Category 5e above cable for 1000Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet B Diagnosing LED Indicators the Switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions
4. fiber port 1 S RJ y Yellow Lower LED Power ud 1 and 2 are both functional The port is supplying power to the No device attached or power Not connected to network On Gonneced network Ports B RJ 45 ports The UTP RJ 45 Fast Ethernet ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or crossover cabling See the below figures for straight through and crossover cable schematic B 45 Pin Assignments signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation user can use straight through cables See figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD Transmit Data minus TD Receive Data minus RD Switch Router or PO 3 TD 5 RD 6 TD RD RD 1 TD 2 RD 4
5. E 4 cllc E 4 PACKAGE WE INS bibis bir bie dientes ise 5 HARDWARE DESCRIPTION ree enr 6 6 FRONT FANE L 6 drea cR M RD T BABAN DEIO E cca cO DO 8 PORES 9 SO AI IK 11 WIRING THE POWER 12 WIRING THE FAULT ALARM CONTACT PME PXLR RII VIR MIRI DR XR S RPNPWIRIWDN Ps 13 MOUNTING INSTALLATION ee 14 ENERO EE I IT T TIER 14 VVALL NIOUNT PEATEAVIOUNTIING icietarotaeeiacebstwtatetabelateldietaretabebatebabeiatebatetatetabelotebitess 16 HARDWARE INSTALLATION eee ee nee een 17 INSTALLATION STEPS 17 NETWORK APPLICATION eee nnn en ens 18 TROUBLESHOOT ING quat OE Pata i ws 19 TECHNICAL SPECIFICATION eene In 20 Introduction The 4 Port PoE 1 Port SC Industrial Fast Ethernet Switch is a cost effective solution and meets the high reliab
6. to assist in identifying problems B power indicator does not light on when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance B If the Industrial switch LED indicators are normal and the connected cables correct but the packets still cannot transmit Please check your system s Ethernet device s configuration or status 19 Technical Specification The IFE 0501 IFE 0502 4 Port PoE 1 Port SC Industrial Fast Ethernet Switch technical specifications are shown as below IFE 0501 4 Port PoE 1 Port Multi mode SC Industrial Fast Ethernet Switch IFE 0502 4 Port PoE 1 Port Single mode SC Industrial Fast Ethernet Switch IEEE 802 3 10Base T Ethernet Standard IEEE 802 3u 100Base TX FX Fast Ethernet IEEE802 3x Flow Control and Back Pressure IEEE802 3af Power over Ethernet 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port MAC Address 1K MAC address table Per unit Power 1 Green Power 2 Green Fault Red LED Fiber Link Active Green TX Link Active Green Full duplex Collision Yellow PoE Feeding Power Green 10Base T 2 UTP STP Cat 3 4 5 5e cable EIA TIA 568 100 ohm 100m Ww 100Base TX 2 pair UTP STP Cat 5 5e cable EIA TIA 568 100 ohm 100m 20 Distance M
7. ility requirements demanded by industrial applications Using fiber port can extend the connection distance that increases the network elasticity and performance In addition the industrial switch provides the PoE function for kinds of Powered Devices to receive power as well as data over the RJ 45 cable Features system Interface Performance RJ 45 ports support Auto MDI MDI X Function Embedded 4 port PoE Injection Store and Forward Switching Architecture Back plane Switching Fabric 1 0Gbps 1K MAC Address Table Fiber cable up to 2km by Full duplex Multi mode IFE 0501 Fiber cable up to 30km by Full duplex Single mode IFE 0502 Power Supply DC 48V Redundant Power Full load with PoE Overload Current Re settable Fuse Present Case Installation IP 30 Protection DIN Rail and Wall Mount Design Provides EFT protection 3 000 VDC for power line Supports 4 000 VDC Ethernet ESD protection Package Contents Please refer to the package contents list below to verify them against the checklist IFE 0501 or IFE 0502 CD Manual Pluggable Terminal Block attached on the switch 2 wall mount plates with screws One DIN Rail attached on the switch Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Hardware Description In this paragraph the Industrial switch s hardware spec port cabling information and wiring
8. installation will be described Physical Dimension 4 Port PoE 1 Port SC Industrial Fast Ethernet Switch dimension W x D x H 15 30mm x 95mm x 140mm Front Panel The Front Panel of the 4 Port PoE 1 Port Multi mode SC Industrial Fast Ethernet Switch is shown as below IFE 0501 P NS M ed m I em xt P2 Fault PR ortu 6 LORS r LU Er S acumen eoe TM MEER E rue ipse val tet eta ae M y E mmn IW uec ditada Front Panel of the IFE 0501 Industrial Fast Ethernet Switch The Front Panel of the 4 PoE 1 Port Single mode SC Industrial Fast Ethernet Switch is shown as below C4 e Pi P2 X emere ees po wd etm pe EE WEM iei n Front Panel of the IFE 0502 Industrial Fast Ethernet Switch Top View The top view of the 4 Port 1 Port SC Industrial Fast Ethernet Switch has one terminal block connector of two DC power inputs DC 48V PWR2 PWRI T Jal Fault Top View of the IFE 0501 IFE 0502 Industrial Fast Ethernet Switch LED Indicators The diagnostic LEDs located on the front panel of the industrial switch provide real time information of system and optional status The following table provides the description of the LED status and their meanings for the switch 5 LNK ACT
9. m contact is in the middle of terminal block connector as the picture shows below When the wires are inserted into ports 3 and 4 they automatically detect the fault status in the event of a power failure by forming an open circuit An example for the fault alarm contact is shown as below Insert the wires into the fault alarm contact The wire gauge for the terminal block should be in the range between 12 24 AWG 13 Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch Rear Side DIN Rail 1 Use the screws to screw the DIN Rail on the rear side of the industrial switch 2 the DIN Rail reverse the step 1 3 After the DIN Rail is screwed on the rear side of the switch insert the top of DIN Rail into the track 14 4 Then lightly push the DIN Rail into the track 5 Check if the DIN Rail is tightened on the track or not 6 To remove the industrial switch from the track reverse steps above 15 Wall Mount Plate Mounting 1 Follow the steps below to mount the industrial switch with wall mount plate 2 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 3 Place the wall mount plate on the rear panel of the indus
10. trial switch 4 Use the screws to screw the wall mount plate on the industrial switch 5 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 6 remove the wall mount plate reverse steps above 16 Hardware Installation In this paragraph we are going to mention how to install the 4 Port PoE 1 Port SC Industrial Fast Ethernet Switch and the installation points to be attended to it Installation Steps 1 Unpack the Industrial switch packing 2 Check if the DIN Rail is screwed on the Industrial switch or not If the DIN Rail is not screwed on the Industrial switch please refer to DIN Rail Mounting section for DIN Rail installation If user want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5e above cable for Ethernet connection 6 Insert one side of the RJ 45 cable into the Industrial switch Ethernet port and another side to the network device s Ethernet port
11. ulti mode 50 125 62 5 125 Optical cable Single mode 9 125um Available distance 2km multi mode 30km single mode Wavelength 1310nm Multi mode Single mode u y Power Consumption DIN rail kit for DIN type cabinet install and wall mount ear Installation for wall mounting Operating Temp 10C to 60C 14 F 140 Operation 5 to 95 Non condensing Humidity Sorog 40 C to 85 Temperature IP 30 30 mm W x 95 mm D x 140mm FCC Class A CE EN61000 4 2 3 4 5 6 8 11 12 CE EN61000 6 2 CE EN61000 6 4 UL Safety cUL CE EN60950 1 IEC60068 2 32 Free fall Stability testing 1 60068 2 27 Shock 4 6Watts without PoE 58Watts Full load with PoE IEC60068 2 6 Vibration 21