1. Discard this piece after removing a O ee ss gt A PES A j h 1 Remove Screw A 2 Remove Section B and Discard Figure 2 NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Step 3 Remove the blower from the box and unwrap it The blower has a rubber grommeted hole at each end see Figure 3 Position the blower under the stove so the grommets are up and the blower control knob is at the left side the left side is determined by standing in front of the stove looking at it The grommeted holes slide over the two threaded studs located at the bottom rear of stove See Figures 3 and 4 Step 4 After placing the blower s grommeted holes over the studs slide a washer over each stud and then secure the blower with the nuts provided See Figure 4 Mounting hole grommets shown here fit over existing studs on stove bottom Blower Assembly of fe rn a Hh ill I LESH If a AN C Soo A hN j i fa M m 4 tom Sa Stove Bot 4 E A Figure 3 Mounting Studs LB w a Blower Nuts Figure 4 Blower Installation Blower Assembly Installed Figure 5 Completed Installation NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Blower Operation The blower will come on when the stove is up to temperature and shut off whe
2. LENNOX HEARTH PRODUCTS INSTALLATION INSTRUCTIONS FOR AN AIR CIRCULATION BLOWER KIT FOR USE WITH THE VINTAGE 27 GAS STOVE KIT CONTENTS 1 ea Blower Assembly item 1 2 ea Washers 10 item 2 2 ea Nuts 10 24 Nylock item 3 1 ea Instruction Sheet Figure 1 Kit Contents 5 32 Allen Wrench Or T Handle Wrench 3 8 End Wrench Pliers TOOLS NEEDED k d N GENERAL INFORMATION a This optional 150 CFM blower for the Vintage gas stove provides variable speed control thermal activation and forced air circulation of the warm air into the room If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distributor or dealer Read this instruction sheet in its entirety before beginning the installation ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND OPERA TION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO THESE INSTRUCTIONS 775202M Rev A 01 2011 LENNOX HEARTH PRODUCTS KITS AND ACCESSORIES AIR CIRCULATION BLOWER KIT MODEL VINT TET BLWR CAT NO 75194 ELITE series TURN OFF THE STOVE AND ALLOW IT TO COMPLETELY COOL BEFORE PROCEEDING INSTALLATION INSTRUCTIONS Step 1 Using an allen wrench remove socket head screw A that secures the heat shield to the bottom of the stove See Figure 2 Step 2 Using pliers twist and break off section B of the heat shield shown as hatched section B in Figure 2
3. n the stove cools The blower control knob must be turned ON for the blower to operate see Figure 6 Blower Control Knob The highest blower speed is obtained by turning the control knob clockwise until it clicks ON Continue to rotate the knob clockwise for a lower speed To turn off rotate the knob counterclockwise until it clicks OFF Blower Control Knob Figure 6 Blower Control Knob Vintage 27 Blower Wiring Diagram Snap Switch Connection Wire Black BLOWER N O Normally Open Contacts Close When Stove Is Hot Figure 7 Wiring Diagram Main Power Cord gt Wire White WARNINGS Once the new blower is properly installed it must be plugged directly into a properly grounded three prong receptacle 120 VAC 60 Hz single phase power supply Do not cut or remove the grounding prong from this plug Do not route power cord under or in front of appliance Ground supply green lead must be connected to the wire attached to the green ground screw located on the unit or blower assembly Failure to do so will result in a potential safety hazard The appliance must be electrically grounded in accordance with local codes or in the absence of local codes the National Electri cal Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code CAUTIONS e Disconnect the plug from receptacle prior to servicing the blower e Label allwires pri
4. orto disconnection when servicing controls Wiring errors can cause improper and dangerous operation e Verify proper operation after servicing a Blower Snap Switch N O ON EK Q TLL Blower Speed Control Control Knob Speed Control Wire Red Speed Control Connection Wire Black lt Main Power Cord Wire Black Ground Wire Green Main Power Cord ml Wire Black NOTE DIAGRAMS amp ILLUSTRATIONS ARE NOT TO SCALE Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information HEARTH PRODUCTS Printed in U S A 2010 Lennox Hearth Products P N 775202M REV A 01 2011 1508 Elm Hill Pike Suite 108 Nashville TN 37210
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL BSD-073 Manual de instrucciones de la Unidad Refrigerante Manuale Stair Robot SR EXPRESS Manuale utente R&S FSW-K17 MC Group Delay User Manual Catalogue Février 2013 Autographes & manuscrits Bedienungsanleitung GPS AutokAmerA - AEG Automotive LTN 6L - Wacker Neuson 000167EX - Bredent Copyright © All rights reserved.
Failed to retrieve file