Home
La Crosse Technology WS-6002U User's Manual
Contents
1. flashes where the Weekday normally appears 2 3 Press and release the button to turn the DST off as will be indicated by the display of OFF in the time LCD Press and release the SET button to confirm the DST setting and to advance to select the language for the weekday IV LANGUAGE SELECTION FOR THE WEEKDAY 1 2 3 V 1 2 3 4 5 Hold down the SET button for 2 seconds the selected time zone will flash press the SET button 2 more times until the default language US flashes in the time LCD Press and release the button to toggle through and to select the desired language There are 3 languages to select from US English F French E Spanish Press and release the SET button to confirm the language setting and to advance to manually set the time TIME SETTING Note When the WWVB signal is found that time will over ride the manually set time Hold down the SET button for 2 seconds the selected time zone will flash press the SET button 3 more times until the hour 12 00 flashes in the time LCD Press and release the button to select the hour Note when setting the hour PM will appear to the left of the hour display if it is AM nothing will be displayed Press and release the SET button to confirm the hour setting and to shift to select the minutes Press and relea
2. and of recommended size Opening the casings invalidates the warranty Do not try to repair the units Contact La Crosse Technology for Repairs TROUBLESHOOTING Problem The LCD is faint Solution 1 Replace the batteries Problem OFL appears in the LCD Solution 1 Move unit to an area with warmer or cooler surrounding temperature Current surrounding temperatures are outside measuring range Problem No reception of WWVB signal Solution 1 It may help reception to face the front of the Atomic Clock in the general direction of Ft Collins Colorado 2 Wait overnight for signal 3 Be sure the Atomic Clock is at least 6 feet from any electrical devices i e TV sets 12 computers or other radio controlled clocks 4 Remove batteries for five minutes reinsert and leave the unit alone overnight without pressing buttons 5 If problems persist contact La Crosse Technology Problem Hour is incorrect minute and date are correct Solution 1 Be sure correct time zone and daylight saving time are selected Note For any questions not answered contact La Crosse Technology with the contact information found at the end of this instructional manual SPECIFICATIONS Temperature Measuring 32 F to 122 F with 0 2 F resolution range 0 C to 50 C with 0 1 C resolution Outside OFL will be displayed range Checkin
3. liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged 15
4. the 12 hour time display flashes in the time LCD Press and release the button to toggle between 12 and 24 hour time Press and release the SET button to confirm the 12 24 hour time display and to advance to select either F or C Note The 24 hour time option is not recommended The LCD display will not show the first digit 2 VII SELECTING F OR C 1 Hold down the SET button for 2 seconds the selected time zone will flash press the SET button 10 more times until the default F flashes in the time LCD 2 Press and release the button to toggle between F and C 3 Press and release the SET button to confirm the F or C selection and exit the Program Mode FEATURES amp OPERATIONS D CHANGING DISPLAY MODE DAY SECONDS AND TEMPERATURE There are three possible display modes to view the day seconds and temperature The month amp date weekday indoor temperature is the default To change the display 1 Press and release the button The display should now show the month amp date weekday seconds 2 Press and release the button a second time and the display will now show the month amp date seconds indoor temperature 3 Press and release the button a third time and the display will return to the normal display II INDOOR TEMPERATURE The Indoor Temperature appears on the right side of the Date LCD The
5. will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST Atomic clock in Boulder Colorado A team of atomic physicists is continually measuring every second of every day to an accuracy of ten billionths of a second per day These physicists have created an international standard measuring a second as 9 192 631 770 vibrations of a Cesium 133 atom in a vacuum This Atomic Clock regulates the WWVB transmitter QUICK SET UP GUIDE 1 Insert two AA batteries into the Atomic Clock 2 Wait 15 minutes for WWVB reception 3 If there is no WWVB reception manually set the time and date instructions in the Program Mode 4 Program the settings 5 Mount the WS 6002U in a suitable location where WWVB signals can be received DETAILED SET UP GUIDE D BATTERY INSTALLATION Note To avoid start up problems make sure that the batteries do not spring free Pr Battery Compartment Battery Cover A ATOMIC CLOCK 1 2 3 Remove the battery cover located on the backside of the function buttons Observe the correct polarity and install 2 AA batteries Replace the battery cover Note After the batteries have been installed all the LCD s Liquid Crystal Display will briefly light up Then the indoor temperature the date as 1 1 and the weekday as MON will be displayed Also the time will appear as for approximately I minute Then t
6. WS 6002U Atomic Clock Instruction Manual E 4 oom TE LA C R O S S E technology tools TECHNOLOGY for home amp office TABLE OF CONTENTS Topic Page Inventory of Contents Additional Equipment 3 About WWVB 3 Quick Set Up Guide 4 Detailed Set Up Guide Battery Installation 5 Program Mode Function Buttons 6 Time Zone Setting 7 DST Daylight Saving Time Setting 7 8 Language Selection 8 Time Setting 8 Calendar Setting 9 12 24 Hour Setting 9 Selecting F or C 10 Features amp Operations Displaying the Seconds 10 Indoor Temperature 10 Mounting 11 12 Maintenance amp Care 12 Troubleshooting 12 13 Specifications 13 Warranty Information 14 15 INVENTORY OF CONTENTS 1 WS 6002U 2 Instruction manual and warranty card ADDITIONAL EQUIPMENT not included 1 Two fresh 1 5V AA batteries 2 Three wall hanging screws 3 Appropriate screwdriver for screws ABOUT WWYVB Radio Controlled Time The NIST National Institute of Standards and Technology Time and Frequency Division WWVB radio station is located in Ft Collins Colorado and transmits the exact time signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the Atomic Clock However due to the nature of the Earth s Ionosphere reception is very limited during daylight hours The Atomic Clock
7. e for the initial set up and will require you to skip step 1 of programming sections III through VIII Wait approximately 15 seconds for the Atomic Clock to automatically return to normal operation I FUNCTION BUTTONS There are 2 function buttons located on the backside of the Atomic Clock The function buttons are labeled SET and ID TIME ZONE SETTING 1 2 3 HI 1 Hold down the SET button for 2 seconds the default setting SEST will flash in the Date LCD Press and release the button to select the appropriate time zone There are 13 time zones to choose from SEST Eastern Time default setting 6CST Central Time 7MST Mountain Time 8PST Pacific Time 9ALA Alaskan Time 1OHAW Hawaiian Time 11 12 GMT Greenwich Mean Time 1 2 3 4ATL Atlantic Time Press and release the SET button to confirm the time zone setting and to advance to DST Daylight saving time setting DST DAYLIGHT SAVING TIME SETTING Note The DST default is On meaning that the WWVB will automatically change the time according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF Hold down the SET button for 2 seconds the selected time zone will flash press the SET button once more until On flashes in the time LCD and DST
8. g Every 10 seconds intervals Power source Battery type 2 x AA IEC LR6 1 5V Alkaline Battery life Approximately 12 months Dimensions 8 3 x 1 2 x 8 4 in Lx Wx HB 211 8 x 30 5 x 214 4mm WARRANTY INFORMATION La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd authorized service center The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Tech
9. he WWVB search is automatically initiated and a tower icon appears and flashes with the time colon no tower icon will appear if the WWVB is too weak to be detected While the WWVB search is being conducted various numbers will appear in the time display The numbers 0 1 or 8 will appear in the hour position and the seconds will appear in the minute display The Atomic Clock will either display the WWVB time or discontinue the search after 10 minutes if the time is not found When the search is cancelled will appear in the time LCD The Atomic Clock will conduct a WWVB search every hour until the first signal is found Once the WWVB time is found a search is automatically conducted nightly at midnight If the signal is found at midnight the tower icon will remain if not another search will take place every hour up to 6 00 am until the signal is found successfully If no signal is found during this period the tower icon will not appear and the clock will search again at 12 00 am the next night WWVB Tower Icon 4 n IO OTHU Te Po Month Date Weekday Indoor Temperature PROGRAM MODE To enter the Program Mode hold down the SET button for 2 seconds until SEST flashes in the Date LCD The Program Mode is laid out in a manner that allows you to program each function separately or you can follow the instructions entirely to program the Atomic Clock Complete programming is usually don
10. l from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you 14 For warranty work technical support or information contact La Crosse Technology Ltd 190 Main Street La Crescent MN 55947 Phone 507 895 7095 Fax 507 895 2820 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacrossetechnology com All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no
11. nology Ltd will pay all expenses for labor and materials for all repairs covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay reasonable return shipping charges to the owner of the product Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other than home use 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or remova
12. se the button to select the minutes Press and release the SET button to confirm the time setting and to advance to manually set the calendar VI CALENDAR SETTING 1 2 3 4 5 6 7 8 9 Note When the WWVB signal is found that date will over ride the manually set date Hold down the SET button for 2 seconds the selected time zone will flash press the SET button 5 more times until the default year 00 flashes in the date LCD Press and release the button to select the year Press and release the SET button to confirm the year and to set the month The default month 1 will flash Press and release the button to select the appropriate month Press and release the SET button to confirm the month and to set the date The default date 1 will flash Press and release the button to select the appropriate date Press and release the SET button to confirm the date and to set the weekday The default weekday MON depends on selected language will flash Press and release the button to select the appropriate weekday Press and release the SET button to confirm the calendar settings and to advance to select either 12 or 24 hour time display VID 12 24 HOUR SETTING 1 2 3 Hold down the SET button for 2 seconds the selected time zone will flash press the SET button 9 more times until
13. temperature is checked every 10 seconds and updated whenever there is a change 10 MOUNTING Hanging Holes Function Buttons Foldout ea Stand There are two possible ways to mount the atomic clock e use of the foldout table stand or e wall mounting I FOLDOUT TABLE STAND The foldout table stand leg is located on the backside of the atomic clock The hinge is towards the center of the atomic clock and the end with no hinge needs to be folded in towards the center Once the foldout table stand is extended place the atomic clock in an appropriate location ID WALL MOUNTING es N WG 11 1 Using a straightedge horizontally space at 3 15 16 of an inch 100 58mm three screw positions on a wall 2 Install three mounting screws not included into a wall within transmission range leaving approximately 3 16 of an inch 5mm extended from the wall 3 Place the Atomic Clock onto the screws using the hanging holes on the backside Gently pull the Atomic Clock down to lock the screws into place MAINTENANCE amp CARE e Extreme temperatures vibrations and shock should be avoided to prevent damage to the units e Clean displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark and damage the displays and casings e Do not submerge in water e Immediately remove all low powered batteries to avoid leakage and damage Replace with new batteries only
Download Pdf Manuals