KTI Networks KSD-103-A Series User's Manual
Contents
1. 0 Forwarding amp filtering Switching technology Maximum packet length Flow control Broadcast Storm DC Power Interface Interface Operating voltages Power consumption DIP SW KSD 103 A SWI SW2 KSD 103 B SWI SW2 SW3 Mechanical Dimension base Weight Housing Mounting support Environmental Operating temperature Storage temperature Relative humidity Non blocking full wire speed Store and forward 1536 bytes max IEEE 802 3x pause frame base for full duplex operation Back pressure for half duplex operation Protection design Screw type terminal block 1 Two pairs for power wire cascading 2 One pair for alarm relay output DC Jack D6 3mm D2 0mm 7V 50V 5 KSD 103 A 2 1W max 7 5VDC input 3 5W max 50VDC input KSD 103 B 3 3W max 7 5VDC input 4W max 50VDC input Broadcast storm protection setting Fiber port FX link down alarm setting Broadcast storm protection setting Fiber port FX1 link down alarm setting Fiber port FX2 link down alarm setting W 28mm x D 82mm x H 95mm 250g Enclosed metal with no fan DIN rail mounting Panel mounting 20 C 70 C 20 C 85 C 5 90 8 20 Certificate FCC CE EMC CE LVD Safety EN 50081 1 1992 Part 15 Class B EMI EN50081 1 Class B EMS EN55024 EN 60950 EN55022 1994 A1 1995 A2 1997 EN61000 3 2 2000 EN61000 3 3 1995 A 1 2001 EN 55024 1998 A 1 2001 IEC 61000 4 2 1995 IEC 61000 4 3 19
2. 95 IEC 61000 4 4 1995 IEC 61000 4 5 1995 IEC 61000 4 6 1996 IEC 61000 4 8 1993 ESD Test RS Test EFT BURST Test Surge Test CS Test Magnetic Field IEC 61000 4 11 1994 Voltage Int Dips 9 20 2 Installation 2 1 Unpacking Check that the following components have been included e Information CD e The device unit e DIN rail mounting bracket If any item is found missing or damaged please contact your local reseller for replacement The following are available optional accessories e Panel Mounting Bracket The bracket is used for mounting the device on a panel surface e Commercial rated AC power adapters Rated input AC120V 60Hz AC230V 50Hz AC100V 50 60Hz AC240V 50Hz Rated output DC7 5V 1A DC7 5V 1 2A e High temperature AC power adapters Rated 10 C 60 C AC100 240V 50 60Hz DC12V 1A for USA and Germany The adapters are used for supplying DC power to the switch via DC power jack interface 2 2 Safety Cautions To reduce the risk of bodily injury electrical shock fire and damage to the product observe the following precautions e Do not service any product except as explained in your system documentation e Opening or removing covers may expose you to electrical shock e Only a trained service technician should service components inside these compartments e If any of the following conditions occur unplug the product from the electrical outlet and replace the part or contact your trained servi
3. En Es e En E En nn hy rl j ge Gore Network Rs AAA A b o ir At A A A E de sy y Ma Fiber Cascading 4 2 Copper to Fiber Bridging Media Converter Application Cat 5 Fiber Copper to Fiber Conversion 4 3 Bridging Multimode to Single Mode Fiber Converter Application MMF SMF single Mode Fiber to Multimode Fiber Conversion 18 20 5 Appendix 5 1 Model Definition KSD 103 A Model Ext FX Connector Ref Distance Operating Temperature Duplex SC 20 70 C sia p se se mm AT BiDi SC 20 70 C W5315 BiDi SC EJ 15 20km 20 70 C KSD 103 B wss pupa pise swe samm awe ma ouse sme me m mc 19 20 5 2 Optical Specifications KSD 103 A 1310nm 15 8dBm KSD 103 B FX2 1550nm 14 8dBm 31dBm FX1 i550 14 8dBm 31dBm W5315 FX2 1310nm 14 8dBm 31dBm FX1 1310nm 20 14dBm 31dBm FX2 1310nm 15 8dBm 30dBm FX1 1310nm 14 8dBm 31dBm OdBm W3515 20 20
4. Industrial 3 Port Fast Ethernet Media Converter Switches KSD 103 A series KSD 103 B series Installation Guide DOC 081111 C 2008 KTI Networks Inc All rights reserved No part of this documentation may be reproduced in any form or by any means or used to make any directive work such as translation or transformation without permission from KTI Networks Inc KTI Networks Inc reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL _ http www ktinet com International Fax 886 2 26983873 E mail kti ktinet com tw URL _ http www ktinet com tw The information contained in this document is subject to change without prior notice Copyright C All Rights Reserved TRADEMARKS Ethernet is a registered trademark of Xerox Corp FCC NOTICE This device complies with Class B Part 15 the FCC Rules Operation 1s subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including the interference that may cause CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the E
5. The industrial rated KSD 103 Fast Ethernet switch series supports three switching base segment communications and benefit the following applications and make fiber deployment easter e Copper to fiber bridging converter e Multimode fiber to single mode fiber bridging converter e Fiber cable extender o Cascaded fiber networking Depending on the types of the network ports two different model series are defined as follows The switch also provide the following advantages Plug and Play No configuration is required in using the switches With the featured auto negotiation function the switches can detect and configure the connection speed and duplex automatically for the copper ports The switches also provide auto MDI MDI X function which can detect the connected cable and switch the transmission wire pair and receiving pair automatically This auto crossover function can simplify the type of network cables used Industrial Features For industrial environment the devices are designed with the following enhanced features exceeding that of commercial Ethernet switches 5 20 High and wide operating Temperature Power input interface Industrial screw terminal block and DC power jack for external commercial power adapter as option Screw panel and DIN rail mounting support for industrial enclosure Industrial rated Emission and Immunity performance Features Provide 3 switching base network segments Auto MDI MDI X cros
6. ce provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Operate the product only from the type of external power source indicated on the electrical ratings 10 20 label If you are not sure of the type of power source required consult your service provider or local power company 2 3 DIN Rail Mounting In the product package a DIN rail bracket is installed on the device for mounting the device in a industrial DIN rail enclosure The steps to mount the device onto a DIN rail are 1 Install the mounting bracket onto the device unit as shown below 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail 3 Clamp the unit to the DIN rail and make sure it is mounted securely 4 Make sure that there are proper heat dissipation from and adequate ventilation around the device 11 20 The final mechanical dimensions after installing DIN rail mounting bracket are 86 5 86 5 e d ed 2 4 Panel Mounting The product is provided with an optional bracket for
7. nly up to four device units can be cascaded to receive power from one main power input Source Using DC Power Jack DC Jack Connector D 6 3mm e D2 0mm AC Power Adapters Optional power adapters are available for purchasing Connect power adapter DC plug to the DC power jack of the converter before connecting to the AC outlet Connect the power adapter to the AC outlet Note Before you begin the installation check the AC voltage of your area The AC power adapter that is used to supply the DC power for the unit should have the AC voltage matching the commercial power voltage in your area 2 6 Failure Alarm Relay Output The device provides a relay output to report failure events to a remote alarm monitoring system The replay output is provided with two contacts labeled PF and PF in the terminal block interface 14 20 Alarm relay output Pet PF Use the provided 2P terminal plug for signal wiring and plug into the PF contacts Relay Output Normal PF and PF contacts shorted Indication Alarm PF and PF contacts open Alarm Events e Input power failure e Specific fiber port link down To specify the fiber ports use the DIP SW located on bottom DIP SW setting Fiber port link down alarm KSD 103 A SWI ON Enable broadcast storm protection OFF Disable broadcast storm protection SW2 ON Enable FX port link down alarm OFF Disable FX port link alarm SW 1 ON Enable broadcast s
8. panel mounting The bracket supports mounting the device on a plane surface securely The mounting steps are 1 Install the mounting bracket on the device unit Screw the bracket on the device unit 2 Screw the device unit on a panel Make sure that there are proper heat dissipation from and adequate ventilation around the device Do not place heavy objects on the device The screw locations and final dimension are shown below 12 20 2 5 Applying Power The power specifications of the device are Operating Voltage 7 50VDC Power Consumption 4W max 50VDC DC power terminal pairs DC Jack Using Terminal Blocks Either DC interface or DC2 interface can be used to receive DC power from an external power system Or DC2 also can be used to deliver the power received on DC1 to next device in cascading Way DCI DCI DC2 DC2 Vdc Positive terminal Vdc Negative terminal Vdc Positive terminal Vdc Negative terminal Three 2P terminal plugs are provided together with the device Two of the three plugs are used for DC1 and DC2 interfaces respectively The plug is shown below Power wires 24 12AWG IEC 0 5 2 5mm Install the power source wires with the plug properly Screw the wire with plug securely Then plug in DC contacts 13 20 If cascading the power to next device is needed install the power wires and plug for another switch Then use DC2 contacts Note O
9. s also auto negotiation capable both devices will come out the best configuration after negotiation process If the connected device is incapable in auto negotiation the switch will sense the speed and use half duplex for the connection 3 2 Making Fiber Connections The fiber ports operate on 100Mbps and full duplex For different fiber connections several alternative models can be selected for different fiber connections The following figure illustrates a connection example between two SC fiber ports RX Fiker cable TX A variety of fiber options and the associated optical specifications are provided as listed in Appendix 1 Network Cables Multimode MMP 50 125 62 5 125 Single mode SMF 9 125 16 20 3 3 LED Indication Interpretation KSD 103 A KSD 103 B LED Function State PWR Power status ON OFF UTPx Copper port link status ON BLINK OFF FXx Fiber port link status ON BLINK OFF Note UTPx UTP UTP UTP FXx FX FX1 FX2 17 20 The power is supplied to the device The power is not supplied to the device Port link is established No traffic Port link is up and there is traffic Port link is down Port link is established No traffic Port link is up and there is traffic Port link is down 4 Applications 4 1 Application in Industrial Networks The following figure illustrates an application example in an industrial network Four devices are cascaded by fiber cables Fa ai
10. sover function on the TP copper port Support IEEE 802 3x flow control for full duplex operation Support Back pressure flow control for half duplex operation Wide operating temperature range for temperature critical environment Support DIN rail mounting and panel mounting Provide two power input types to meet more application needs Accept wide power input voltage range for application flexibility Industrial rated Emission and Immunity performance 1 2 Product Panels The following figure illustrates the faces of the switches KSD 103 A DC power input Terminal block DC power jack LED indicators Din rail DIP SW mounting Fiber port holes link down alarm 6 20 KSD 103 B Din rail mounting holes DC power interface terminal block DC power jack LED indicators DIP SW Fiber port link down alarm 1 3 Specifications Copper Ports Compliance Connectors Pin assignments Configuration Transmission rate Duplex support Network cable Fiber Ports Connectors Configuration Network cables Eye safety Far end fault support Switch Functions MAC Addresses Table IEEE 802 3 10Base T IEEE 802 3u 100Base TX Shielded RJ 45 jacks Auto MDI MDI X detection Auto negotiation 10Mbps 100Mbps Full Half duplex Cat 5 UTP up to 100 meters ST SC VF 45 Bi Directional SC model dependent 100Mbps Full duplex MMF 50 125 60 125um SMF 9 125um IEC 825 compliant Enabled K entries 7 2
11. torm protection OFF Disable broadcast storm protection SW2 ON Enable FX1 port link down alarm KSD 103 B OFF Disable FX1 port link alarm SW3 ON Enable FX2 port link down alarm OFF Disable FX2 port link alarm Note Be sure the voltage applied on PF contacts is within the specification of 3OVDC IA max or 120VAC 0 5A max 15 20 3 Making LAN Connections 3 1 Making Copper Port RJ 45 Connections The copper ports support the following connection types and distances Network Cables IOBASE T 2 pair UTP Cat 3 4 5 EIA TIA 568B 100 ohm 1I00BASE TX 2 pair 4 pair UTP Cat 5 EIA TIA 568B 100 ohm Link distance Up to 100 meters Auto MDI MDI X Function This function allows the port to auto detect the twisted pair signals and adapts itself to form a valid MDI to MDI X connection with the remote connected device automatically No matter a straight through cable or crossover cable connected the ports can sense the receiving pair automatically and configure self to match the rule for MDI to MDI X connection It simplifies the cable installation by using only straight through cables Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device i
12. uropean Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Class B EN 50081 1 1992 EN55022 1994 A1 1995 A2 1997 Class B EN61000 3 2 2000 EN61000 3 3 1995 A 1 2001 EN 55024 1998 A1 2001 IEC 61000 4 2 1995 IEC 61000 4 3 1995 IEC 61000 4 4 1995 IEC 61000 4 5 1995 IEC 61000 4 6 1996 IEC 61000 4 8 1993 IEC 61000 4 11 1994 3 20 Table of Contents Eee a 5 UN IURATI TEE EDEN 6 1 2 Product P anols sea teitarenst ees pen doe E ed abandacen Fev em Rast E edes 6 A etin M SM M EM DM E I EP CEA LA IE Aidh 7 EE meet 10 ZEE socie dte CC TTE 10 22 SEV Caul NS eaa Tr P eem 10 2 3 DIN RalMOUMUNO ui 11 22 Panel MOUNN erae A 12 2 5 ADDIVING PO Wan ina td 13 2 6 Faure Alarm Relay Output cities 14 SEMEL rS Eee 16 3 1 Making Copper Port RJ 45 Connections cccccoonncncccnnoccncnnnconnnnnncnnnnnnonennnnnnnnnnnos 16 9 2 MakingsEIbDer Connections aoctor Qnod Pede He mad d beo eO DM Copt n een 16 cron EDIC ANO er EL STE TT 17 As PADDING AION Sada 18 4 1 Application in Industrial NetworksS ccoooccccococoocnnocccnncononononnononncnnnnonanonnnnos 18 4 2 Copper to Fiber Bridging Media Converter Application 18 4 3 Bridging Multimode to Single Mode Fiber Converter Application 18 A o o plo onm 19 5 1 WIOGE DEI PEE ind 19 5 2 Optical SPECICATION atan dd 20 4 20 1 Introduction
Download Pdf Manuals
Related Search
Related Contents
ASRock IMB-161-D Owner's Manual Canne Pliante Autoportante Nissin Di866 User's Manual 8142PRO+ Industrial Terminal Service Manual Fast Back 100 Manual de Intrucciones_ Sarten electrica MANUAL TÉCNICO Y DE INSTALACIÓN "user manual" Notes de lecture 7 Manual de Instalação, Operação e Programação dos Copyright © All rights reserved.