Home

Klaxon CMC4 MMI User's Manual

image

Contents

1. 44AH Microphone Rack Multi siren system remote controlled by satellite network and computer Satellite Network Satellite amp i a Satellite Antenna z wo Antenna Satellite Satellite Antenna Antenna Talos20 Software Satellite Application Antenna Sat Phone Up EEN downlink Desktop lt 1 A Microphone Ea A HALMA GROUP COMPANY Klaxon Signals Limited Wrigley Street Oldham T 44 0 161 287 5555 E sales klaxonsignals com Lancashire UK OL4 1HW F 44 0 161 287 5511 w www klaxonsignals com
2. amp 5 8 GHz spread spectrum frequency hopping microwave radio data and voice Single or bidirectional COFDM radio Data and voice Direct satellite bidirectional data and voice GSM and GPRS Data Voice subject to local service provider Serial data and voice over 600 ohm lines POT RS 485 data Fibre optic networks Data and voice TCP IP Data and VoIP d Serial data from SCADA terminal with standard DCS protocols Parallel dry contact from SCADA or dedicated cables Simple siren control by hardwire parallel inputs amp control out puts Me f 4 Control F Relay outputs for CS 8 Parallel lt Connection with Inputs for _ Existing systems S Iren Connection Control RA Klaxon Signals Limited A Wrigley Street Oldham T 44 0 161 287 5555 E sales klaxonsignals com HALMA GROUP Lancashire UK OL4 1HW F 44 0 161 287 5511 w www klaxonsignals com COMPANY Electronic Siren Control Methods klaxxon Siren System by remote control by CMC 4 CS Siren Control Siren System remote control by RS485 and computer CS Talos20 Siren Line RS485 Software M A
3. Electronic Siren Control Methods klaxon CMC4 MMI The CMC4 MMI unit provides a means of siren control and interrogation for a single siren system Control of up to 4 alarm signals amp 4 pre recorded messages Microphone input connector for live voice messages Dd Silent test activation facility and test results displayed on the 2 line LCD p Communication link to the siren is via an RS485 interface p Power for the unit is provided by the RS485 interface Key operated switch to disable signal amp voice activation function CMC500 MMI The CMC500 MMI unit provides a means of control and interrogation required for a multiple siren system Control of up to 16 alarm signals amp 230 pre recorded messages Microphone input connector for live voice messages LED display unit b User controllable alarm signal amp message volume control User controllable alarm signal amp message repetition rate control User controllable siren group control Dd Siren silent test activation facility and test results displayed on the 2 line LCD p Communication link to the siren is via an RS485 interface b Power for the unit is provided by an integral re chargeable battery pack D Multi user identification amp control restriction function Talos 20 Software MMI Console The software which operates under Microsoft windows allows the means of control and interrogation required for a multiple si
4. a VHF 3DB or UHF 5 DB Collinear bd 30 m coaxial antenna feeder Control Station d Workstation Pentium 400MHz 64 bit processor keyboard mouse and CD Rom drive D 17 inch touch screen D UPS 30 minutes d Printer Dot Matrix Sheet Feeder Desk microphone Or B CMC4 control engineers panel Microphone Control Software for PC based control station TALOS software for Windows XP operation with the following features capabilities Group or individual activation and different zones Activate 16 different signals programmable Activate 255 different WAV Files Activate live audio Remote control all the sirens parameters L AC monitors Q Batteries voltage _ Auto report at any changes of programmable I Os Q Test amplifiers and drivers Quiet Test Test performed at 10KHz Log all reports to file or printer Klaxon Signals Limited A Wrigley Street Oldham T 44 0 161 287 5555 E sales klaxonsignals com HALMA GROUP Lancashire UK OL4 IHW F 44 0 161 287 5511 w www klaxonsignals com COMPANY Electronic Siren Control Methods klaxxon Control Methods The siren control communication network can be implemented using any one of the following systems or with a combination of two of these systems Land Mobile Narrow Band FM Radio Operating frequencies VHF 136 174 MHz or UHF 403 470 MHz Data and voice TETRA Data and voice bd APCO 25 For use in the USA D 2 4
5. incad RS SS RASA AE cas Ys BICEACR SS IRS ot Application Control a O Amplifier 7 e Microphone Klaxon Signals Limited Wrigley Street Oldham T 44 0 161 287 5555 E sales klaxonsignals com HALMA GROUP Lancashire UK OL4 1HW F 44 0 161 287 5511 w www klaxonsignals com COMPANY Electronic Siren Control Methods Siren System remote control by radio and CMC 4 SBD VHF or SBD UHF Base Station 19 2U Rack fies 12VDC 12AH 44AH Battery Siren System remote control by radio and computer SBD VHF or SBD UHF Base Station 19 2U Rack 12VDC 12AH 44AH Battery Microphone Talos20 Software Application CS Siren Control CS Siren Control klaxon Klaxon Signals Limited Wrigley Street Oldham Lancashire UK OL4 1HW T 44 0 161 287 5555 F 44 0 161 287 5511 E sales klaxonsignals com w www klaxonsignals com A HALMA GROUP COMPANY Electronic Siren Control Methods klaxxon Multi siren system remote controlled by radio and computer Wireless Network Antenna Antenna Antenna Antenna Talos20 Software Application Antenna SBD VHF or S BD m UHF 12VDC Desktop Base Station 19 2U 42AH
6. ren system Control of up to 16 alarm signals amp 230 pre recorded messages Live voice control facility DB Siren silent test activation facility and test results displayed User definable legends Master volume control User definable siren group allocation bd Event amp test logs Klaxon Signals Limited A Wrigley Street Oldham T 44 0 161 287 5555 E sales klaxonsignals com HALMA GROUP Lancashire UK OL4 IHW F 44 0 161 287 5511 w www klaxonsignals com COMPANY Electronic Siren Control Methods klaxon Radio and Control Equipment Siren radio communication equipment Motorola GM340 Databox Transceiver Operating frequencies VHF 136 174 MHz or UHF 403 470 MHz bd Antenna 3 Element YAGI bd 15 m coaxial antenna feeder D TK401 Data Modem 1200 4800 bps Cables and accessory connector Base station communication equipment Simplex transceiver for voice and DATA computer connection Operating frequencies VHF 136 174 MHz or UHF 403 470 MHz D RF power 1 to 25 W programmable B RJ45 input for Motorola desktop Microphone HMN 3000B for announcement External battery 12V 44AH for continues operation when AC failure d Integrated power supply 120W 110 230VAC for continues operating and charging battery D TK401 Radio modem 1200 4800 Bps Transparent Mode with DB9 pins RS232 I O Cabinet 19 Rack 2U with temperature control fan Wall mounting cabinet optional bd Antenn

Download Pdf Manuals

image

Related Search

Related Contents

Vector G1 GPS Satellite Compass    AllerAir 600 Series User's Manual  Catalogue vente bijoux-montres du 12 octobre  Northrop Grumman LITEF GmbH  technical specification of mobile flash butt welding machine  décembre 2012 - Une Souris Verte    Samsung PL100 คู่มือการใช้งาน  PG-FP5 V2.11 Flash Memory Programmer User`s Manual  

Copyright © All rights reserved.
Failed to retrieve file