Home

KitchenAid Pro Line Range Hood User's Manual

image

Contents

1. To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burne
2. Vent Piece 3 1 4 x 10 8 3 cm x 25 4 cm 7 17 8 cm 8 20 3 cm Rectangular 9 22 9 cm 10 25 4 cm Round A 45 elbow 7 0 feet 2 5 feet igen 2 1 m A 0 8 m S y 90 elbow 5 0 feet 5 0 feet Maximum length 35 ft 10 7 m 1 5 m 1 5 m ZA I 1 90 elbow 5ft 15m 8 ft 2 4 m straight 8ft 2 4 m 1 wall cap 0ft 0m 90 flat elbow 12 0 feet S o 3 7 m S2 Length of 3 1 4 x 10 8 3 cm x 25 4 cm system 13 ft 3 9 m transinon 1o round o Note Flexible vent is Not recommended Flexible vent creates back pressure wall cap 0 0 feet and air turbulence that greatly 0 0 m Q reduces performance Electrical requirements Important Observe all governing codes and ordinances It is the customer s responsibility e To contact a qualified electrical installer e To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A 120 volt 60 Hz AC only fused electrical system is required on a separate 15 amp circuit fused on both sides of the line Do not ground to a gas pipe Check with a qualified electrician if you
3. 106 7 cm 1 N 48 121 9 cm 2 Se Damper screws Er 30 76 2 cm 2 36 91 4cm 2 j 42 106 7 cm 2 48 121 9 cm 4 pee ca oe oe Damper 30 76 2 cm 1 EIE ae i 36 91 4 cm 42 106 7 cm 1 48 121 9 cm 2 This unit must be grounded o Note Backsplash vent cover discharge transition and chimney extension kits are available from your dealer see page 9 These are required for some installations and must be installed at time of hood installation as shown in the Installation Instructions Important Observe all governing codes and ordinances Proper installation is your responsibility e Have a qualified technician install this range hood e Comply with installation clearances specified on the model serial rating plate The model serial rating plate is located inside the range hood on the rear wall Range hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance Consult your cooktop range manufacturer installation instructions before making any cutouts Grounded electrical outlet is required See Electrical requirements The canopy hood is factory set for venting through the roof or wall To vent directly through the wall the blower must be rotated to face the rear
4. En cas d incertitude quant la qualit de la liaison la terre de la hotte consulter un lectricien qualifi Ne pas installer un fusible en s rie avec le conducteur neutre ou le conducteur de liaison la terre IMPORTANT Conserver les instructions d installation l intention de l inspecteur local des installations lectriques La hotte doit tre raccord e au r seau d alimentation Le calibre des conducteurs CUIVRE SEULEMENT et les pi ces de connexion doivent tre compatibles avec la demande de courant de l appareil sp cifi e sur la plaque signal tique La taille des conducteurs doit satisfaire les prescriptions du Code national des installations lectriques ANSI NFPA 70 derni re dition ou des normes CSA C22 1 94 Code canadien de l lectricit 1 re partie et C22 2 N 0 M91 derni re dition et avec les prescriptions de tous les codes et r glements locaux en vigueur 0 M91 derni re dition et avec les prescriptions de tous les codes et r glements locaux en vigueur Si un conducteur distinct de liaison la terre est utilis lorsque le code le permet on recommande qu un lectricien qualifi v rifie que la liaison la terre est ad quate L appareil doit tre aliment par un circuit de 120 volts 60 Hz CA seulement 15 avec un fusible sur lectrique uniquement avec des conducteurs de cuivre La hotte doit tre raccord e directement au coupe
5. Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient ADANGER Risque possible de d c s ou de blessure grave si vous ne suivez pas imm diatement les instructions A AVERTISSEMENT Risque possible de d c s ou de blessure grave si vous ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions Important Observer les dispositions de tous les codes et r glements en vigueur C est vous qu incombe la responsabilit de e Demander a un technicien qualifi d installer cette hotte e Respecter lors de l installation les d gagements de s paration sp cifi s sur la plaque signal tique de l appareil La plaque signal tique avec num ro de mod le et num ro de s rie est situ e l int rieur de la hotte sur la paroi arri re La hotte d aspiration devrait toujours tre install e distance des sources de courants d air comme fen tres portes et bouches de chauffage On doit respecter les dimensions indiqu es pour l ouverture dans le placard Les dimensions indiqu es 2 tiennent compte des d gagements de s paration n cessaires Avant d effectuer un d coupage consulter les instructions d installation fournies par le fabricant de
6. Ne pas visser dans le panneau de gypse seulement sommet de la hotte 31 9 cm 31 9 cm 12 9 16 po 12 9 16 po 1 6 121 9 cm 48 po au dessus de la table de cuisson 175 cm 1 1 16 po hotte de 76 2 cm 30 po sommet de la hotte 39 5 cm 39 5 cm 15 9 16 po 15 9 16 po lt gt gt 121 9 cm 48 po 175 cm 1 1 16 po au dessus de la table de cuisson hotte de 91 4 cm 36 po 1 1 16 po 7 po Ouvertures pour conduit d vacuation et c ble lectrique 7 5 cm 2 7 8 po Gy 2 9 cm 1 1 8 po o ms 7 24 6 cm Ouverture pour c ble lectrique hotte de 76 2 cm 30 po 9 11 16 po 7 5 cm 2 7 8 po Dimensions des ouvertures de d charge 8 3 x 25 4 cm 7 5 cm 3 1 4 x 10 po 2 7 8 po l 7 5 cm 2 7 8 po hotte de 91 4 cm 36 po LA hotte de 106 7 cm 42 po 83 32 po Ouverture pour ib cable lectrique lt nae 72 po hotte de 121 9 cm 48 po sommet de la hotte ES 47 2 cm 47 2 cm 18 9 16 po 18 9 16 po gt C ja 6 yU DER 17 5 cm 10 8 cm 10 8 cm 1 1 16 po 4 1 4 po 4 1 4 po 121 9 cm 48 po au dessus de la table de cuisson Y hotte de 106 7 cm 42 po sommet de la hotte rit oT 175 cm 178 em 178 cm 7 po 121 9 cm 48 po au dessus de la table de cuisson hotte de 121 9 cm 48 po 54 9 cm 54 9 cm 21 9 16 po 21 9 16 po gt lt gt
7. The 30 76 2 cm 36 91 4 cm and 42 106 7 cm models have one exhaust opening 3 1 4 x 10 8 3 cm x 25 4 cm rectangular 7 17 8 cm round 8 20 3 cm round 9 22 9 cm round or 10 25 4 cm round vent may be used The hood exhaust opening is 3 1 4 x 10 8 3 cm x 25 4 cm The 48 121 9 cm model has two 3 1 4 x 10 8 3 cm x 25 4 cm exhaust openings It is recommended that Vent Transition Kit No 8284757 be used to transition the two openings into one 10 25 4 cm round vent Cannot be used with Chimney Extension Kit No 8284754 Vent system can terminate either through the roof or wall The vent system length should not exceed the lengths shown in the chart Vertical venting Horizontal venting roof cap 3 1 4 x 10 8 3 cm x 25 4 cm vertical venting roof or wall 3 1 4 x 10 8 3 cm x 25 4 cm horizontal venting wall cap Vent size Maximum length 3 1 4 x 10 8 3 cm x 25 4cm 35 ft 10 7 m 7 178 cm round 40 ft 12 2 m 8 20 3 cm round 50 ft 15 2 m 9 22 9 cm round 60 ft 18 3 m 10 25 4 cm round 60 ft 18 3 m Example for 3 1 4 x 10 Calculating the vent system length 8 3 cm x 25 4 cm vent system To calculate the length of the system you need add the equivalent feet meters for each vent piece used in the system 3 1 4 x 10 wall 8 3 cm x 25 4 cm cap elbow lt s ft 1 8 m
8. de 121 9 cm 48 po un conduit d vacuation de 25 4 cm 10 po installer maintenant le raccord de transition tringle hotte vis de montage La hotte de 76 2 cm 30 po comporte deux tringles La hotte de 91 4 cm 36 po comporte deux tringles La hotte de 106 7 cm 42 po comporte quatre tringles La hotte de 121 9 cm 48 po comporte quatre tringles 1 1 La hotte se fixe au mur au moyen des vis mentionn es l tape 5 des instructions d installation La hotte est suspendue ces vis par des tringles l int rieur de la hotte de la cuisini re Avant d essayer de suspendre la hotte utiliser un tournevis Phillips pour tourner la vis d ajustement marqu e V1 dans le sens antihoraire pour d ployer les tringles de la hotte Suspendre la hotte de la cuisini re en ins rant les tringles dans les vis de montage tel qu illustr Remarque Ces vis doivent tre install es dans du bois massif pour supporter le poids de la hotte tel que d crit l tape 5 Visser les vis marqu es V1 pour serrer la hotte contre le mur S assurer que la hotte est fix e solidement au mur 12 On utilise galement les brides pour r gler l aplomb de la hotte Pour le r glage de l aplomb faire tourner les vis V2 vis Phillips 1 3 m Raccorder le conduit d vacuation la hotte Assurer l tanch it des jointures avec du ruban adh sif pour conduit 14 Si la garniture cache conduit option est u
9. tablissement de l alimentation MISE EN GARDE Cet appareil est con u uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LATABLE DE CUISSON Ne jamais laisser un l ment de la table de cuisson fonctionner sans sur veillance la puissance de chauffage maximale un renversement d borde ment de mati re graisseuse pourrait provoquer une inflammation et le g n ration de fum e Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors d une cuis son avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber Nettoyer fr quemment les ventila teurs d extraction Veiller ne pas laisser de la graisse s accumuler sur les surfaces du ventilateur ou des fil tres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un usten sile de taille adapt la taille de l l ment chauffant AVERTISSEMENT POUR REDUIRE LE RISQUE DE DOMMAGES CORPORELS APRES LE DECLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIERE APPLIQUER LES RECOMMANDATIONS SUIVANTES Placer sur le r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR ETOUFFER LES FLAMMES puis teindre le br leur VEILLER A EVITER LES
10. vement des filtres Note Lors de la d pose des filtres tirer faire tourner le bouton avec une main et tenir le filtre avec l autre main pour qu il ne tombe pas sur la table de cuisson e Tirer le bouton vers l avant de la hotte en le tournant vers la gauche sens antihoraire pour d bloquer le levier de verrouillage R installation des filtres voir l tape 16 Surfaces ext rieures e Ne pas utiliser un produit de nettoyage abrasif ou un tampon de laine d acier e Frotter dans la direction du grain pour ne pas d t riorer la surface e S cher par essuyage pour qu il ne reste pas de marques des gouttes d eau e Le produit recommand pour le nettoyage des surfaces d acier inoxydable de la hotte est le produit KitchenAid Professional Formula Steel Cleaner amp Polish Pour commander ce produit contacter notre centre de service client au 1 800 442 9991 ou commander a partir de notre site Internet a l adresse www applianceaccessories com le num ro de produit est 8171420 Pour commander au Canada composer le 1 800 807 6777 Si on utilise des nettoyants commerciaux suivre les instructions sur l tiquette Ne pas utiliser de produits chlor s eau de Javel Le chlore est une substance corrosive Pour le nettoyage de routine et l limination des marques de doigt utiliser un m lange d eau et de d tergent liquide ou un produit de nettoyage polyvalent Frotter avec une ponge ou un linge
11. BRULURES Si les flammes ne s teignent pas imm diatement EVACUER LA PI CE ET CONTACTER LES POMPIERS NE JAMAIS PRENDRE EN MAIN UN RECIPIENT ENFLAMME le risque de br lure est lev NE PAS UTILISER D EAU ni un torchon humide ceci pourrait provoquer une explosion de vapeur br lante Utiliser un extincteur SEULEMENT si Il s agit d un extincteur de classe ABC dont on conna t le fonctionnement Il s agit d un petit feu encore limit l endroit o il s est d clar Les pompiers ont t contact s Il est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu Remplacement d une lampe halog ne Illustration avec hottes de 91 4 cm 36 po et de 106 7 cm 42 po Avant de commencer placer tous les commutateurs de la hotte la posi tion d arr t et v rifier que les lampes se sont suffisamment refroidies La temp rature de service d une lampe a halog ne est tr s lev e Pour remplacer une lampe halog ne e ter les deux vis de la garniture m tallique circulaire plac e autour de la lampe eTirer sur l ensemble garniture mod ule de lampe suffisamment pour qu il soit possible de d gager la lampe de la douille e Ins rer une lampe neuve dans la douille et remettre l ensemble mod ule de lampe garniture en place dans la hotte e Refixer la garniture Utilisation de la
12. I Aoo RE EE 1 1 16 48 121 9 cm 17 5 cm min to cooking surface 30 76 2 cm hood y top of hood 15 9 16 15 9 16 39 5 cm 39 5 cm I I I A a ak 1 1 16 48 121 9 cm 17 5 cm min to cooking surface 36 91 4 cm hood ex 9 11 16 24 6 cm 2 7 8 7 5 cm 2 7 8 7 5 cm 48 121 9 cm hood top of hood LE TE NE MR 18 9 16 472cm 18 9 16 472 cm ni oP l 4 1 4 1 1 16 4 1 4 175 cm 10 8 cm 10 8 cm 48 121 9 cm min to cooking 42 106 7 cm hood me top of hood 21 9 16 21 9 16 i 54 9 cm i 54 9 cm l ee _ ay t j o 1 1 16 7 7 175 cm 17 8 cm 17 8 cm 48 121 9 cm min to cooking surface 48 121 9 cm hood 6 3 32 15 5 cm All vent openings are 3 1 4 x 10 8 3 cm x 25 4 cm 2 7 8 7 5 cm 2 7 8 7 5 cm 10 1 2 26 7 cm ba Optional vent cover installation Attach the full width vent cover to the top of the range hood with the screws provided The vent cover must be attached to the top of the range hood before mounting the range hood to the wall A 30 76 2 cm hood 13 15 32 34 2 cm 36 91 4 cm hood 16 15 32 41 8 cm 42 106 7 cm hood 19 15 32 49 4 cm 48 121 9 cm hood 22 15 32 57 1 cm B 30 76 2 cm hood 26 15 16 68 4 cm 36 91 4 cm hood 32 15 16 83 7 cm 42 106 7 cm hood 38 1
13. S il est n cessaire d installer plusieurs coudes ceux ci devront tre s par s par une section rectiligne d au moins 61 cm 24 po e Ne pas raccorder deux coudes ensemble e Pour maximiser l efficacit minimiser la longueur effective totale du syst me de d charge et le nombre de coudes e Le syst me de d charge doit comporter un volet de r glage Si la bouche de d charge sur le toit ou travers le mur comporte un volet de r glage ne pas utiliser le volet de r glage fourni avec la hotte e Au niveau de chaque jointure du syst me de d charge assurer l tanch it avec du ruban adh sif pour conduit e Autour de la bouche de d charge l ext rieur assurer l tanch it avec un produit de calfeutrage D terminer la m thode d vacuation de l air la plus appropri e pour l application et ex cuter la pr paration d crite dans les instructions d installation la page 5 oo 3 5 cm 1 3 8 po Dimensions des placards 1 I 1 1 I IL j hotte 76 2 cm 30 po 76 2 cm 30 po hotte 91 4 cm 36 po 91 4 cm 36 po hotte 106 7 cm 42 po 106 7 cm 42 po h hotte 121 9 cm 48 po 121 9 cm 48 po distance libre min entre les placards I I I I Le F _ distance min LT profondeur le bas de la hotte et du placard __ la table de cuisson 33 cm 13 po 76 2 cm 30 po hauteur libre min au
14. are not sure range hood is properly grounded Do not have a fuse in the neutral or ground circuit IMPORTANT Save Installation Instructions for electrical inspector s use The range hood must be connected with copper wire only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire sizes Installation steps COPPER WIRE ONLY and connections must conform with the rating of the appliance as specified on the model serial rating plate Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply cable at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 top of backsplash Preparation It is recommended that the vent system be installed corner before hood is installed on 29 7 8 75 9 cm 35 7 8 91 1 cm 41 7 8 106 4 cm
15. circuit avec fusibles ou aux disjoncteurs par l interm diaire de c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un passe fil homologation UL ou CSA doit tre install chaque extr mit du c ble Un connecteur de conduit homologation UL ou CSA doit tre install chaque extr mit du c ble d alimentation sur la hotte et sur la bo te de connexion On peut obtenir aux adresses suivantes des exemplaires des normes mentionn es National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Les tapes de l installation Pr paration ll est pr f rable que le circuit d vacuation soit install avant l installation de la hotte On ne doit couper une solive ou un poteau de colombage que lorsque cela est absolument n cessaire S il est n cessaire de couper une solive ou un poteau du colombage on doit construire une structure de support appropri e Avant d effectuer le d coupage v rifier que les distances de s paration appropri es seront respect es autour du conduit d vacuation dans le plafond ou la cavit du mur V rifier que toutes les pi ces n cessaires pour l installation et la bo te comportant les filtres ont t retir es de l emballage 1 Si c est possible d brancher la cuisini re autonome ou mobile et retirer la cuisini
16. d assistance ou de service au Canada 1 Si le probl me n est pas attribuable 2 Si vous avez besoin de servicet Communiquer avec la succursale ou tablissement r E eee Pai l une des causes indiqu es dans Guide de service autoris de KitchenAid Canada le plus proche de d pannage t pour l entretien de votre appareil Voir liste ci dessous S assurer que la compagnie de service que vous contactez Communiquer avec le marchand chez qui est autoris e faire l entretien de votre appareil durant la vous avez achet votre appareil lectrome riode de garantie nager ou t l phoner a KitchenAid Canada P 4 au Centre d interaction avec la client le sans frais d interurbain entre TLorsque vous demandez de l assistance ou un 8 h 30 et 18 h 00 HNE en composant 1 800 235 0665 service veuillez fournir une description d taill e du probl me les num ros complets du mod le et de s rie de l appareil et la date d achat Ces renseignements nous aideront mieux r pondre votre demande Service d appareils m nagers KitchenAid Canada Service aux consommateurs Succursales de service direct COLOMBIE BRITANNIQUE 800 665 6788 ALBERTA 800 661 6291 ONTARIO R gion d Ottawa 800 267 3456 exception de l indicatif r gional 807 En dehors de la r gion d Ottawa 800 807 6777 MANITOBA SASKATCHEWAN 800 665 1683 et indicatif r gional 807 en ONTARIO QU BEC Montr al l exceptio
17. hotte au dessus de la table de cuisson est de 76 2 cm 30 po voir page 3 Le dosseret peut tre prolong de 50 1 cm 19 23 32 po 99 1 cm 39 po Note L augmentation de la hauteur de 76 2 cm 30 po s accompagne d une diminution de l aire de capture de la hotte 5 e D terminer la hauteur d installation de la hotte e Positionner la hotte contre le mur en faisant coincider le bord inf rieur de la hotte avec le sommet du dosseret Marquer la position des quatre trous des angles On recommande que le dosseret soit fix au mur dans les quatre angles cependant on peut aussi ne pas placer les vis des angles inf rieurs et caler la l vre inf rieure entre le mur et un dosseret existant le plan de travail ou le placard inf rieur e Percer des trous de 8 mm 5 16 po e Enfoncer compl tement les chevilles de plastique dans les trous e Faire coincider les trous du dosseret avec les chevilles d ancrage et installer les vis de fixation fournies 5 a La hotte doit tre fix e au mur avec les vis de montage conform ment aux indications de l illustration Il y a deux vis de montage pour les mod les de 76 2 cm 30 po et 91 4 cm 36 po Il y a quatre vis de montage pour les mod les de 106 7 cm 42 po et 121 9 cm 48 po Visser chaque vis horizontalement dans le mur jusqu ce que la t te de vis soit bien serr e contre le mur Note Les vis de fixation de la hotte doivent tre viss es dans du bois massif
18. or roof opening around the cap Determine which venting method is best for your application and follow Preparation under Installation steps on Page 5 18 45 7 cm Cabinet dimensions 1 Eoso 30 76 2 cm hood 30 76 2 cm 36 91 4 cm hood 36 91 4 cm 42 106 7 cm hood 42 106 7 cm 48 121 9 cm hood 48 121 9 cm min cabinet opening widths F sn cabinet depth ee Sa NE TD 30 76 2 cm min bottom of canopy to cooking surface OO min clearance upper cabinet to countertop 36 91 4 cm base cabinet height For installations with canopy only minimum of 84 3 16 213 8 cm For installations with optional vent hood cover minimum of 96 3 16 244 3 cm Ceiling height above canopy or canopy with optional vent hood is unlimited Venting methods This canopy range hood is factory set for vertical venting For rear vent applications the blower must be turned inside the range hood so that the blower vents to the rear as indicated The blower is turned by removing two screws on each side of the blower rotating the blower with the exhaust opening facing the rear and then replacing the screws The exhaust cover s must be moved to block the unused opening s The blower must be converted before installing the range hood Vent system needed for installation is not included
19. re de son encastrement entre les placards pour pouvoir acc der au mur arri re Sinon placer un pais mat riau de protection sur le plan de travail la table de cuisson ou la cuisini re pour la protection contre la poussi re et les dommages ventuels Choisir une surface plane pour l assemblage de l appareil Recouvrir cette surface d un mat riau de protection appropri avant d y placer tous les composants de la hotte et les accessoires 2 Sur le mur marquer la ligne qui correspondra l axe central de la hotte apr s son installation Si le circuit d vacuation est d j install utiliser l axe central de l ouverture du conduit 75 9 cm 29 7 8 po 91 1 cm 35 7 88 po 106 4 cm 41 7 8 po 121 6 cm 47 7 8 po ed sommet du dosseret trous de fixation dans les angles Hauteur du dosseret 50 1 cm 19 23 32 po 99 1 cm 39 po 9 5 mm 3 8 po 25 4 mm 1 po 3 Pour une d charge par l arri re horizontalement si le circuit d vacuation n est pas install tracer et d couper maintenant l ouverture de passage du conduit 4 Important Si un dosseret doit tre utilis option on doit l installer avant la hotte Si aucun dosseret n est utilis passer l tape 5 Installation du dosseret Cet ensemble comporte 4 chevilles de plastique pour l ancrage mural et 4 vis de montage e La hauteur du dosseret d terminera la hauteur de la hotte Note La hauteur minimale de la
20. tenir le filtre en place avec l autre main pour qu il ne tombe pas sur la table de cuisson e Saisir l un des filtres de telle sorte que le bouton soit orient vers le bas et vers l arri re de la hotte e Ins rer l extr mit du filtre ne com portant pas le bouton dans la rainure de retenue l avant de la hotte e Tirer sur le bouton et le tourner vers la gauche sens antihoraire de telle sorte que le levier de verrouillage ne fasse pas saillie hors du filtre e Ins rer l extr mit comportant le bou ton dans la rainure de retenue l ar ri re de la hotte e Tourner le bouton vers la droite sens horaire pour verrouiller le filtre en place e R p ter la proc dure pour les autres filtres Controle du fonctionnement 1 7 Mettre la hotte sous tension 1 8 Les commandes de la hotte sont plac es sous la hotte droite commandes filtres 1 9 Contr ler le bon fonctionnement de la hotte Placer l interrupteur d clairage la position 1 la lampe doit s allumer Placer le commutateur du ventilateur la position 1 le ventilateur doit se mettre en marche Placer le bouton de s lecteur de vitesse la position 1 basse vitesse puis la position 2 vitesse moyenne puis la position 3 haute vitesse Placer les commutateurs d clairage et du ventilateur la position 0 pour commander l arr t du ventilateur et l extinction de la la
21. 2 to adjust the level of the canopy 13 Connect vent system to hood Seal all joints with duct tape 14 If your installation uses the optional vent cover fit the cover flanges over the brackets If installation uses the chimney extension fit the extension over the brackets Install the upper section first then fit the lower section over the upper section Seal extension to hood with duct tape Electrical connection AWARNING Electrical Shock Hazard Disconnect power before making electrical connections Connect ground wire to green ground screw in terminal box Failure to do so can result in death or electrical shock 15 Make electrical connection Connect the power supply cable to hood terminal box through the U L or C S A listed conduit connector Connect the white wire of the power supply cable with the white lead in the hood using a twist on connector connect the black wire of the power supply cable with the black lead in the hood using a twist on connector Connect the power supply green ground wire under the green ground screw Tighten conduit connector screws Replace the terminal box cover 7 16 Install the filters e Remove the filters from the box and remove the white protective coating from the filters Note Use two hands to install filter one to pull and turn the knob the other to hold the filter in place so that it doesn t fall onto the cooktop e Grasp on
22. 21 9 cm 48 po comporte deux ouvertures de d charge de 8 3 x 25 cm 3 1 4 x 10 po On recommande l utilisation de l ensemble de transition de conduit d vacuation n 8284757 pour connecter les deux ouvertures un conduit circulaire de 25 4 cm 10 po de diam tre Ne peut tre utilis avec l ensemble d extension de chemin e n 8284754 Le circuit de d charge peut d charger l air l ext rieur travers le mur ou travers le toit La longueur effective du circuit ne doit pas tre D charge travers le toit D charge horizontale conduit de 8 3 x 25 cm 3 1 4 x 10 po d charge travers le toit d charge travers le mur bouche de conduit de 8 3 x 25 cm 3 1 4 x 10 po d charge travers le mur Taille des conduits Longueur maximale 8 3 x 25 cm 3 1 4 x 10 po 10 7 m 35 pi Rond dia 178 cm 7 po 12 2 m 40 pi Rond dia 20 3 cm 8 po 15 2 m 50 pi Rond dia 22 9 cm 9 po 18 3 m 60 pi Rond dia 25 4 cm 10 po 18 3 m 60 pi Calcul de la longueur effective du syst me de d charge Pour calculer la longueur effective du syst me de d charge on doit tenir compte de la longueur quivalente de chaque composant du syst me Composant Conduit rectangulaire Conduit rond dia 8 3 x 25 cm 3 1 4 x 10 po 178 cm 7 po 20 3 cm 8 po 22 9 cm 9 po 25 4 cm 10 po coude 45 2 1m 0 8 m
23. 47 7 8 121 6 cm Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent Check that all the installation parts and the box with filters have been removed from the shipping carton 1 a If possible disconnect and move freestanding or slide in range from cabinet opening to provide easier access to rear wall Otherwise put a thick protective covering over countertop cooktop or range to protect from damage or dirt Select a flat surface for assembling the unit Cover that surface with a protective covering and place all hood parts and hardware in it 2 Determine and mark the centerline on the wall where the hood will be installed If the vent system is already installed use centerline of vent opening 3 If venting horizontally out the back of hood and vent system is not installed mark and cut vent opening now 4 Important If used Backsplash Kit must be installed before installing the hood If a backsplash is not used go to Step 5 Backsplash installation The hardware package supplied with the kit includes 4 plastic wall anchors and mounting screws eThe height of the backsplash will determine the height Extends from 19 23 32 50 1 cm 99 1 cm of the hood Note The minimum height of the hood above the cooktop as
24. 5 16 98 9 cm 48 121 9 cm hood 44 15 16 114 1 cm Install each bracket on the wall as shown Make sure that the screws and brackets are securely fastened to the wall Install only the brackets Do not install the hood 5b a If chimney extension is used Attach the extension brackets as shown 10 5 8 ceiling 27 cm A Ses Ml brackets y gt 2 8 1 8 gt lt gt 8 1 8 20 6 cm 20 6 cm 23 58 4 cm max 12 30 5 cm min top of hood Make sure that the screws are securely fastened to the wall G Determine and make all necessary cuts in the wall for the vent system Install the vent system before the canopy hood See venting methods on Page 4 and hood vent opening dimensions on Page 6 7 Determine the required height for the power supply cable and cut a 1 1 4 3 2 cm hole at this location Run wire through hole according the National Electrical Code or CSA Standards and local codes and ordinances There must be enough power supply cable from the fused disconnect or circuit breaker box to make the connection in the hood s electrical box Use caulking to seal all openings Do Not turn on power until installation is completed 8 Remove the terminal box cover from the canopy hood Remove the power supply cable knockout using a flat blade screwdriver Attach conduit connector into power supply cable opening so that co
25. 7 pi A 2 5 pi S coude a 90 1 5 m 1 5 m 5 pi FA 5 pi s coude a 90 plat 3 7 m 12 pi raccord de transition 1 5 m rectangle rond 5 pi gt bouche de d charge Om murale 0 pi Exemple pour conduit d vacuation de 8 3 cm x 25 cm 3 1 4 po x 10 po Coude 8 3 x 25 cm bouche de 3 1 4 x 10 po d charge murale e a m 6 pi gt 0 6 m 2 pi Longueur maximale 10 7 m 35 pi 1 coude 90 1 5m 5 pi Section droite 2 4 m 8 pi 2 4m 8 pi 1 bouche de d charge murale Om 0 pi Longueur effective de conduit de 8 3 x 25 cm 3 1 4 x 10 po 4m 13 pi Note On d conseille l emploi de conduit d vacuation flexible Un conduit d vacuation flexible cr e une contre pression et une turbulence de l air qui r duisent consid rablement la performance Alimentation electrique Important Respecter les prescriptions de tous les codes et reglements en vigueur C est au client qu incombe la responsabilit de e Contacter un lectricien qualifi pour l installation e Veiller ce que l installation lectrique soit r alis e d une mani re ad quate et en conformit avec les prescriptions du Code national des installations lectriques ANSI NFPA 70 derni re dition ou des normes CSA C22 1 94 Code canadien de l lectricit 1 re partie et C22 2 N chaque conducteur Ne pas utiliser une tuyauterie de gaz pour la liaison la terre
26. 76 2 cm hood Not available 91 4 cm hood Not available 106 7 cm hood Not available 121 9 cm hood Kit No 8284757 Wiring diagrams koJ amp a NA 090 IE a dae ere is D dl ane 4 GRN j For 30 76 2 cm 36 91 4 cm j j n 120 VAC and 42 106 7 cm hoods ne For 48 121 9 cm hoods 8 BS SOK AI20 8 BS SOK A120 KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase when this major appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid or KitchenAid Canada hereafter KitchenAid will pay for factory specified parts and repair labor to correct defects in materials or workmanship Service must be provided by a KitchenAid designated service company ITEMS KITCHENAID WILL NOT PAY FOR 1 Service calls to correct the installation of your major appliance to instruct you how to use your major appliance to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace appliance light bulbs air filters or water filters Those consumable parts are excluded from warranty coverage 3 Repairs when your major appliance is used for other than normal single family household use Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing
27. Aid U S A KitchenAid Canada licensee in Canada 10 2005 Instructions d installation et Guide d utilisation et d entretien Hotte d aspiration pour cuisini re Pro Line montage mural 76 2 cm 30 po 91 4 cm 36 po 106 7 cm 42 po 121 9 cm 48 po IMPORTANT R f rence rapide Lire et conserver Table des mati res a Pages ces instructions 2 Avant de commencer 3 Dimensions du produit 3 Dimensions des placards IMPORTANT 3 Circuit de d charge de l air Installateur Remettre les instructions 5 Alimentation lectrique d installation au propri taire de l appareil 5 7 Les tapes de l installation en nae B Utilisation et entrer Conserver les instructions d installation 9 Sch ma de c blage l intention de l inspecteur local des installations 9 Accessoires lectriques 10 Garantie 11 112 Demande d assistance ou de service 4329454 9763385 Avant de commencer Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves a vous et a d autres
28. DE AUTORIS E PAR LA LOI KITCHENAID N ASSUME AUCUNE RESPONSABILITE POUR LES DOMMAGES FORTUITS OU INDIRECTS CERTAINES JURIDICTIONS NE PERMETTENT PAS L EXCLUSION OU LA LIMITATION DES DOMMAGES FORTUITS OU INDIRECTS OU LES LIMITATIONS DE LA DUR E DES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER DE SORTE QUE CES EXCLUSIONS OU LIMITATIONS PEUVENT NE PAS S APPLIQUER DANS VOTRE CAS CETTE GARANTIE VOUS CONFERE DES DROITS JURIDIQUES SPECIFIQUES ET VOUS POUVEZ EGALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION A UNE AUTRE l ext rieur du Canada et des 50 Etats des Etats Unis cette garantie ne s applique pas Contacter votre marchand KitchenAid autoris pour d terminer si une autre garantie s applique Si vous avez besoin de service voir d abord la section D pannage du Guide d utilisation et d entretien Apr s avoir v rifi la section D pannage de l aide suppl mentaire peut tre trouv e en v rifiant la section Assistance ou service ou en appelant KitchenAid Aux E U composer le 1 800 422 1230 Au Canada composer le 1 800 807 6777 10 05 11 Demande d assistance ou de service Avant de faire un appel pour assistance ou service d une visite de service Si vous avez encore besoin veuillez v rifier la section Contr le du fonctionnement d aide suivre les instructions ci dessous Cette v rification pourrait vous faire conomiser le co t Si vous avez besoin
29. Installation Instructions and Use and Care Guide 30 76 2 cm 36 91 4 cm 42 106 7 cm 48 121 9 cm Wall Mount Pro Line Range Hood IMPORTANT Read and save these instructions IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use 4329454 9763385 Quick Reference Table of Contents Pages Before you start Product dimensions Cabinet dimensions Venting requirements Electrical requirements Installation steps Use and Care Information Wiring diagrams Accessories Warranty JEEN Requesting Assistance or Service Before you start Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean A DANGER You can be killed or seriously injured if you don t immediately follow instructions AWARNING You can be killed or seriously injured if you don t f
30. TATEURS COULISSANTS amp 0 1 0 1 TRANSFORMATEUR BLK NOIR GRN VERT wi z WHT BLANC d g ORG ORANGE 81 BLU BLEU VLT VIOLET Ci BRW BRUN CIRCUIT D ALIMENTATION GRY GRIS Pour hottes de 76 2 cm 30 po 91 4 cm 36 po et 106 7 cm 42 po 10 COMMUTATEURS COULISSANTS lt a 3 OO 00 TRANSFORMATEUR ale LAMPES ORIENTABLES I l l BO TE DE CONNEXION agi lt ml 8 CIRCUIT D ALIMENTATION Pour hottes de 121 9 cm 48 po GARANTIE DU SYST ME DE VENTILATION KITCHENAID GARANTIE LIMITEE DE UN AN Pendant un an compter de la date d achat lorsque ce gros appareil m nager est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit KitchenAid ou KitchenAid Canada ci apr s d sign es KitchenAid paiera pour les pi ces sp cifi es par l usine et la main d uvre pour corriger les vices de mat riaux ou de fabrication Le service doit tre fourni par une compagnie de service d sign e par KitchenAid KITCHENAID NE PRENDRA PAS EN CHARGE 1 Les visites de service pour rectifier l installation du gros appareil m nager montrer l utilisateur comment utiliser l appareil remplacer ou r parer des fusibles ou rectifier le c blage ou la plomberie du domicile 2 Les visites de service pour r parer ou remplacer les ampoules lectriques de l appareil les filtres air ou les filtres eau Ces pi ce
31. anopy hood control panel The hood controls are located on the right hand underside of the canopy controls SS light blower blower speed switch switch switch Operating the light ON Move the light switch to the 1 position OFF Move the light switch to the 0 position Operating the blower ON Move the blower switch to the 1 position OFF Move the blower switch to the 0 position Adjusting the blower speed The blower has three speed control Move the blower speed switch to 1 position for low speed 2 position for medium speed or 3 position for high speed Cleaning Filters The filters should be washed frequently Place metal filters in dishwasher or hot detergent solution to clean To remove filters Note Use two hands to remove filters one to pull and turn the knob the other to hold the filter so that it doesn t fall onto the cooktop e Pull knob forward toward the front of the hood while turning the knob to the left counter clockwise to release the locking lever To reinstall filters see Step 16 Exterior surfaces e Do not use steel wool or soap filled scouring pads e Rub in direction of the grain line to avoid marring the surface e Always wipe dry to avoid water marks e KitchenAid Professional Formula Stainless Steel Cleaner amp Polish is the cleaner recommended for cleaning stainless steel s
32. ba Installation de la garniture cache conduit option Placer la garniture au sommet de la hotte fixer avec les vis fournies La garniture doit tre fix e au sommet de la hotte avant l installation de la hotte sur le mur sommet de la hotte hotte 76 2 cm 30 po 34 2 cm 13 15 32 po hotte 91 4 cm 36 po 41 8 cm 16 15 32 po hotte 106 7 cm 42 po 49 4 cm 19 15 32 po hotte 121 9 cm 48 po 57 1 cm 22 15 32 po B hotte 76 2 cm 30 po 68 4 cm 26 15 16 po hotte 91 4 cm 36 po 83 7 cm 32 15 16 po hotte 106 7 cm 42 po 98 9 cm 38 15 16 po hotte 121 9 cm 48 po 114 1 cm 44 15 16 po Installer chaque bride sur le mur selon l illustration Veiller ce que les brides soient solidement fix es sur le mur Installer seulement les brides Ne pas installer la hotte bb Utilisation d une extension de chemin e Fixer les brides de l extension selon l illustration 27 cm Las 10 5 8 DO porn rss brides y s A E 20 6 cm lt gt lt gt 20 6 cm 8 1 8 po 8 1 8 po 58 4 cm 23 po max 30 5 cm 12 po min sommet de la hotte Veiller a ce que les vis soient solidement fix es dans le mur 6 Tracer et d couper l ouverture n cessaire dans le mur pour le conduit d vacuation Installer le circuit de d charge avant la hotte Voir les configurations de d charge a la page 4 Voir a la page 6 les dim
33. codes or use of products not approved by KitchenAid Replacement parts or repair labor costs for units operated outside the United States or Canada Pickup and delivery This major appliance is designed to be repaired in the home Repairs to parts or systems resulting from unauthorized modifications made to the appliance Expenses for travel and transportation for product service in remote locations The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions A NS 0 DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE Outside the 50 United States and Canada this warranty does not apply Contact your authorize
34. d KitchenAid dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use amp Care Guide After checking Troubleshooting additional help can be found by checking the Assistance or Service section or by calling KitchenAid In the U S A call 1 800 422 1230 In Canada call 1 800 807 6777 10 05 10 Requesting Assistance or Service To avoid unnecessary service calls please check the Check Operation section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service in U S A Call the KitchenAid Customer Interaction Center toll free at 1 800 235 0665 Our consultants are available to assist you When calling Please know the purchase date and the complete model and serial number of your appliance This information will help us better respond to your request N Our consultants provide assistance with e Features and specifications on our full line of appliances e Installation information e Use and maintenance procedures e Accessory and repair parts sales e Specialized customer assistance Spanish speaking hearing impaired limited vision etc e Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United Sta
35. dessus du plan de travail 45 7 cm 18 po hauteur des placards inf rieurs 91 4 cm 36 po Pour installation avec hotte seulement minimum de 213 8 cm 84 3 16 po Pour installation avec garniture cache conduit option minimum de 244 3 cm 96 3 16 po Pas de limitation pour la hauteur du plafond au dessus de la hotte ou de la hotte avec garniture Configurations de circuit de d charge La hotte d aspiration est configur e l usine pour la d charge travers le toit ou un mur Pour l vacuation par l arri re il faut modifier l orientation du ventilateur l int rieur de la hotte pour que le ventilateur rejette l air par l arri re Pour cela ter les deux vis de chaque c t du ventilateur changer l orientation du ventilateur pour placer la d charge face l arri re puis r installer les vis On doit ensuite d placer les plaquettes d obturation pour obturer les ouvertures non utilis es On doit effectuer cette conversion avant d installer la hotte Le conduit d vacuation n cessaire n est pas inclus Les mod les de 76 2 cm 30 po 91 4 cm 36 po et 106 7 cm 42 po comportent une ouverture de d charge On peut utiliser un conduit d vacuation rectangulaire de 8 3 x 25 cm 3 1 4 x 10 po ou un conduit circulaire de 178 cm 7 po 20 3 cm 8 po 22 9 cm 9 po ou 25 4 cm 10 po de diam tre La hotte comporte un orifice de d charge de 8 3 x 25 cm 3 1 4 x 10 po La hotte de 1
36. doux puis rincer avec de l eau propre et s cher par essuyage Ensembles d installation disponibles chez le revendeur local Accessoires utilisables pour l installation option disponibles chez le revendeur local Note Ces ensembles sont disponibles seulement en acier inoxydable Dosseret Le dosseret doit tre install avant l installation de la hotte Hotte de 76 2 cm 30 po ensemble n 8285148 Hotte de 91 4 cm 36 po ensemble n 8284756 Hotte de 106 7 cm 42 po ensemble n 8284827 Hotte de 121 9 cm 48 po ensemble n 8284755 Garniture cache conduit hauteur 30 5 cm 12 po profondeur 30 5 cm 12 po Hotte de 76 2 cm 30 po ensemble n 8285149 Hotte de 91 4 cm 36 po ensemble n 8284753 Hotte de 106 7 cm 42 po ensemble n 8284828 Hotte de 121 9 cm 48 po ensemble n 8284752 Sch mas de c blage Extension de chemin e Pour l extension de la hauteur de 30 5 cm 12 po 58 4 cm 23 po Utilisation avec une hotte de 76 2 cm 30 po 91 4 cm 36 po 106 7 cm 42 po et 121 9 cm 48 po ensemble n 8284754 Raccord de transition de deux conduits de 8 3 x 25 4 cm 3 1 4 po x 10 po un conduit rond de 25 4 cm 10 po Ne pas utiliser l ensemble d extension pour chemin e no 8284754 Hotte de 76 2 cm 30 po pas disponible Hotte de 91 4 cm 36 po pas disponible Hotte de 106 7 cm 42 po pas disponible Hotte de 121 9 cm 48 po ensemble n 8284757 COMMU
37. e of the filters so that the knob faces down and toward the back of the hood e Insert the filter end without the knob into the retaining channel in the front of the hood e Pull and turn the knob to the left counterclockwise so that the locking lever does not protrude from the filter e Insert the knob end of the filter into the retaining channel in the back of the hood eTurn the knob to the right clockwise to lock the filter in place e Repeat for remaining filters Check operation 1 7 Turn power on 1 8 The canopy hood controls are located on the right hand underside of the canopy controls 1 9 m Check the operation of the range hood Move light switch to 1 position The light should turn on M Move blower switch to 1 position The blower should operate Move the blower speed switch to 1 position for low speed 2 position for medium speed or 3 position for high speed Move blower and light switches to 0 position to turn blower and light off If range hood does not operate Check that the circuit breaker is not tripped or the house fuse blown Disconnect power supply Check that wiring is correct To get the most efficient use from your new range hood read the Use and Care Information section Keep your KitchenAid Installation Instructions and Use and Care Guide close to range hood for easy reference Use and Care Information WARNING
38. ensions des ouvertures de sortie 7 D terminer la hauteur appropri e pour l orifice de passage du cable d alimentation percer un trou de 32 mm 1 1 4 po cet endroit Faire passer le c ble travers le trou selon les prescriptions du Code national des installations lectriques ou de la norme CSA ou des codes ou r glements locaux en vigueur La longueur du c ble devra tre suffisante pour qu il soit possible de r aliser les connexions ad quates dans la bo te de connexion de la hotte Assurer l tanch it avec un produit de calfeutrage au niveau de chaque ouverture Ne pas mettre le circuit sous tension avant d avoir achev l installation 8 ter le couvercle de la bo te de connexion de la hotte A l aide d un tournevis lame plate arracher l opercule de l orifice de passage du c ble d alimentation Installer un connecteur de conduit dans cette ouverture la vis de bridage du connecteur de conduit doit tre l int rieur de la hotte amp AVERTISSEMENT Danger poids excessif Deux personnes ou plus doivent intervenir pour d placer et installer la hotte Le non respect de cette instruction peut causer une blessure au dos ou d autres blessures 9 Si aucun volet de r glage n est associ la bouche de d charge murale ou sur le toit installer le volet de r glage dans l ouverture de d charge au sommet de la hotte avec deux vis Phillips 1 O0 Si on doit raccorder la hotte
39. hotte La fonction de la hotte est d aspirer les fum es vapeurs de cuisson et odeurs au dessus de la table de cuisson Pour obtenir les meilleurs r sultats mettre le ventilateur de la hotte en marche avant le d but de la cuisson et laisser le ventilateur fonctionner pendant plusieurs minutes apr s l ach vement de la cuisson pour l extraction de toute fum e et odeur de la cuisine Acc s aux organes de commande de la hotte Les organes de commande de la hotte sont plac s sur la face inf rieure de la hotte droite commandes JS 0 1 y jlo nt a LE all j e E E B l interrupteur commutateur s lecteur de d clairage du ventilateur vitesse ventilateur Utilisation de la lampe MISE EN MARCHE Placer l interrupteur d clairage la position 1 EXTINCTION Placer l interrupteur la position O Utilisation du ventilateur MISE EN MARCHE Placer le commutateur du ventilateur la position 1 ARR T Placer le commutateur la position O R glage de la vitesse du ventilateur Le ventilateur est command par un s lecteur trois positions position 1 basse vitesse position 2 moyenne vitesse position 3 haute vitesse Nettoyage Filtres Il convient de laver fr quemment les filtres Placer les filtres m talliques dans le lave vaisselle ou dans une solution chaude de d tergent Enl
40. la cuisini re ou table de cuisson Une prise de courant lectrique reli e la terre est n cessaire Voir Sp cifications de l installation lectrique La hotte d aspiration est configur e l usine pour la d charge travers le toit ou un mur Pour la d charge directe travers un mur on doit changer l orientation du ventilateur pour le placer face l arri re de la hotte Assurer l tanch it au niveau de chaque ouverture d coup e dans le plafond ou le mur pour l installation de la hotte AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC ELECTRIQUE OU DOMMAGES CORPORELS OBSERVER LES PRESCRIPTIONS SUIVANTES Le travail d installation et de c blage lectrique doit tre ex cut par des personnes comp tentes et en con formit avec les prescriptions des normes et codes applicables ceci incluant les normes de r sistance au feu des l ments de construction La disponibilit d un volume d air appropri pour l alimentation de l quipement combustion et l vacuation des gaz de combustion par la chemin e pour qu il n ait pas de reflux est n cessaire Respecter les directives du fabricant de l quipement de chauffage et les normes de s curit publi es par des organismes comme la National Fire Protection Association NFPA et la American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE et par les autorit s r glementaires locales Lors de t
41. low Contact the dealer from whom you urchased your appliance or call the p Y PP Make sure the service company you contact is KitchenAid Canada Customer f Interaction Center toll free authorized to service your appliance during the 8 30 a m 6 p m EST warranty period at 1 800 235 0665 tWhen asking for assistance or service please provide a detailed description of the problem your appliance s complete model and serial numbers and the purchase date This information will help us respond properly to your request KitchenAid Canada Appliance Service Consumer Services Direct service branches BRITISH COLUMBIA 1 800 665 6788 ALBERTA 1 800 661 6291 ONTARIO Ottawa area 1 800 267 3456 except 807 area code Outside the Ottawa area 1 800 807 6777 MANITOBA SASKATCHEWAN 1 800 665 1683 and 807 area code in ONTARIO QUEBEC Montreal except South Shore 1 800 361 3032 South Shore Montreal 1 800 361 0950 Quebec City 1 800 463 1523 Sherbrooke 1 800 567 6966 ATLANTIC PROVINCES 1 800 565 1598 For further assistance If you need further assistance you can write to Please include a daytime phone number in your KitchenAid Canada with any questions or concerns at correspondence Consumer Relations Department KitchenAid Canada 1901 Minnesota Court Mississauga Ontario L5N 3A7 4329454 9763385 2005 KitchenAid Printed in Italy Registered trademark trademark of Kitchen
42. mpe Si les composants de la hotte ne fonctionnent pas correctement D terminer si le circuit d alimentation de la hotte est aliment disjoncteur ouvert ou fusible grill D connecter la hotte du circuit d alimentation V rifier que le c blage a t correctement r alis Pour obtenir la plus grande efficacit de cette nouvelle hotte lire la section Utilisation et d entretien Conserver en lieu s r les instructions d installation et le Guide d utilisation et entretien KitchenAid pour pouvoir facilement les consulter Utilisation et entretien AVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique ne pas utiliser ce ventilateur en conjonction avec un dispositif de r glage de la vitesse a semi conducteurs AVERTISSEMENT POUR MINIMISER LE RISQUE D INCENDIE CHOC ELECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES Utiliser cet appareil uniquement de la mani re pr vue par le fabricant Pour toute question contacter le fabricant Avant d entreprendre des op rations de r paration ou nettoyage de l ap pareil interrompre l alimentation lec trique au niveau du tableau de distrib ution et verrouiller le disjoncteur pour emp cher un r tablissement acciden tel de l alimentation S il n est pas possible de verrouiller le disjoncteur ou autre coupe circuit veiller bien fixer sur le tableau de distribution une tiquette pro minente interdisant le r
43. n de la Rive Sud 800 361 3032 Rive Sud Montr al 800 361 0950 Qu bec 800 463 1523 Sherbrooke 800 567 6966 PROVINCES DE LATLANTIQUE 800 565 1598 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez Veuillez indiquer dans votre correspondance un num ro de crire en soumettant toute question ou probleme au t l phone o l on peut vous joindre le jour Service des relations avec la client le KitchenAid Canada 1901 Minnesota Court Mississauga Ontario L5N 3A7 329454 9763385 2005 KitchenAid U S A Imprim en Italie Marque d pos e de KitchenAid U S A KitchenAid porteur de licence au Canada 10 2005
44. nduit connector clamping screws are inside of canopy hood AWARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury 9 If roof or wall cap does not have a damper attach damper to exhaust opening s on top of the hood using two Phillips head screws 1 0 If 48 121 9 cm hood is to be connected to 10 25 4 cm round vent system install the vent transition piece now bracket ae mounting screw 30 76 2 cm hood has two brackets 36 91 4 cm hood has two brackets 42 106 7 cm hood has four brackets 48 121 9 cm hood has four brackets 1 1 The hood attaches to the wall by screws discussed earlier in the installation instructions at Step 5 The hood hangs from these screws by brackets inside the range hood Before attempting to hang the hood use a Phillips screwdriver to rotate the adjustment screw marked V1 counterclockwise to extend the brackets from the canopy Hang the range hood by inserting the brackets into the mounting screws as shown Note These screws must be installed into solid wood to support the weight of the hood as described in Step 5 Rotate the screws marked V1 to tighten the range hood against the wall Make sure that the range hood is securely tightened against the wall 12 m The brackets are also used to adjust the level of the canopy Using a Phillips screwdriver rotate the screw V
45. of the range hood All openings in ceiling and wall where range hood will be installed must be sealed Tools needed caulking gun and weatherproof caulking compound flat blade screwdriver measuring tape or ruler wire stripper or utility knife screwdriver Product dimensions 12 1 32 30 6 cm 12 30 5 cm T 18 3 16 46 2 cm Ds 25 3 16 30 76 2 cm hood 29 7 8 75 9 cm 64 cm 36 91 4 cm hood 35 7 8 91 1 cm 42 106 7 cm hood 41 7 8 106 4 cm 48 121 9 cm hood 47 7 8 121 6 cm Venting requirements Vent system must terminate to the outside Do not terminate the vent system in an attic or other enclosed area Do not use 4 inch 10 2 cm laundry type wall caps Use metal vent only Rigid metal vent is recommended Do not use plastic or metal foil vent For the most efficient and quiet operation e The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used Do Not install two elbows together The length of vent system and number of elbows should be kept to a minimum to provide efficient performance The vent system must have a damper If roof or wall cap has a damper Do Not use damper supplied with the range hood Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall
46. ollow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by qualified person s in accordance with all applicable Codes and Standards including fire related construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork Parts needed e 2 U L or C S A listed 1 2 12 5 mm conduit connectors e power supply cable e 1 wall or roof cap e metal vent system Parts supplied Mounting screws 30 76 2cm 2 36 91 4cm 2 42 106 7 cm 4 48 121 9 cm 4 Exhaust outlet cover 30 76 2 cm 1 36 91 4 cm 1 42
47. oute op ration de d coupage ou de per age dans une cloison ou un plafond veiller a ne pas endommager les cables lec triques et canalisations qui peuvent s y trouver Le conduit de d charge associ a un ventilateur doit se terminer l ex t rieur AVERTISSEMENT Pour r duire le risque d incendie utiliser unique ment des conduits m talliques Cet appareil doit tre reli la terre Pi ces n cessaires 2 connecteurs de conduit 12 5 mm 1 2 po homologation U L ou CSA c ble d alimentation 1 bouche de d charge pour toit ou mur conduit d vacuation m tallique pince d nuder SRE couteau utilitaire cisaille de Pi ces fournies Vis de montage 76 2 cm 30 po 2 Plaquettes d obturation 91 4 cm 36 po 2 orifices de sortie 76 2 cm 30 po 1 106 7 cm 42 po 4 91 4 cm 36 po 1 121 9 cm 48 po 4 106 7 cm 42 po 1 121 9 cm 48 po 2 we nel Vis pour volet de Ca r glage 76 2 cm 30 po 2 91 4 cm 36 po 2 if 106 7 cm 42 po 2 121 9 cm 48 po CS Ca Volet de r glage 76 2 cm 30 po 1 aa 91 4 cm 36 po 1 Cr 106 7 cm 42 po 1 121 9 cm 48 po 2 lt hotte Note D autres pi ces sont disponibles chez le revendeur local voir page 9 dosseret garniture cache conduit pour le sommet de la hotte raccord de transition et ensemble d extension de chemin e Ce
48. r BE CAREFULTO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALLTHE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being called You can fight the fire with your back to an exit Replacing the Halogen lamps 36 91 4 cm and 42 106 7 cm hoods shown Before you begin make sure that the range hood is turned off and that the other lamps have had sufficient time to cool Halogen bulbs burn extremely hot To replace a halogen lamp e Remove 2 screws from the circular metal trim around the lamp assembly e Pull the trim with the lamp assembly attached down far enough so that the lamp can be pushed out of the socket e Insert the new lamp into the socket and push the lamp and trim assembly back up into the hood e Replace the trim Operation The canopy hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen Opening the c
49. s pi ces peuvent tre n cessaires dans certaines installations et elles doivent alors tre utilis es lors de l installation de la hotte conform ment aux instructions d installation Outillage n cessaire g m che bois 11 4 po pistolet d application pour produits de calfeutrage et ou scie chantourner ruban adh sif pour conduits r gle ou m tre ruban tournevis J i lame plate jf tournevis Phillips Dimensions du produit 30 6 cm Eds po AS 30 5 cm pa a option A 5 6 cm 46 2 cm 2 7 32 po 18 3 16 po 1 nn 1 hotte 76 2 cm 30 po 75 9 cm 29 7 8 po hotte 91 4 cm 36 po 91 1 cm 35 7 8 po hotte 106 7 cm 42 po 106 4 cm 41 7 8 po hotte 121 9 cm 48 po 121 6 cm 47 7 8 po Circuit de decharge 64 cm 25 3 16 po de lair Le syst me doit d charger l air l ext rieur Ne pas terminer le conduit d vacuation au dessus d un plafond ou dans autre espace ferm Ne pas utiliser une bouche de d charge murale de 10 2 cm 4 po normalement utilis e pour un appareil de buanderie Utiliser uniquement du conduit m tallique On recommande l emploi de conduit m tallique rigide Ne pas utiliser des conduits de plastique ou de m tal mince flexible Pour un fonctionnement efficace et silencieux e La taille du conduit d vacuation doit tre uniforme e Ne pas utiliser plus de trois coudes 90 e
50. s consomptibles ne sont pas couvertes par la garantie 3 Les r parations lorsque le gros appareil m nager est utilis des fins autres que l usage unifamilial normal 4 Les dommages imputables accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d lectricit ou de plomberie ou l utilisation de produits non approuv s par KitchenAid 5 Le co t des pi ces de rechange et de la main d uvre pour les appareils utilis s hors des Etats Unis ou du Canada 6 Le ramassage et la livraison Ce gros appareil m nager est con u pour tre r par a domicile 7 Les r parations aux pi ces ou syst mes r sultant d une modification non autoris e faite l appareil 8 Les frais de voyage ou de transport pour le service d un produit dans les r gions loign es 9 La d pose et la r installation de votre appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instructions d installation fournies CLAUSE D EXONERATION DE RESPONSABILIT AU TITRE DES GARANTIES IMPLICITES LIMITATION DES RECOURS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PR VUE CI DESSUS LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALIT MARCHANDE ET D APTITUDE UN USAGE PARTICULIER SONT LIMIT ES UN AN O LA PLUS COURTE P RIO
51. shown on Page 3 is 30 76 2 cm The backsplash can be extended from 19 23 32 50 1 cm to 39 99 1 cm Note As the 30 76 2 cm installation height increases the hood s capture area decreases e Determine the height of the hood e Position the hood on the wall so that the top of the backsplash is at the height of the bottom edge of hood Mark the location of the four corner holes It is recommended that the backsplash be attached to the wall at all four corners However the lower flange can be secured between the wall and backsplash countertop or cabinet base without using the bottom corner screws e Drill 5 16 8 mm holes e Push the plastic wall anchors all the way into the holes e Position the holes in the backsplash over the wall anchors and attach using the screws supplied Vent and Electrical openings N Electrical opening 30 76 2 cm hood 36 91 4 cm hood 42 106 7 cm hood 5 The hood attaches to the wall with the mounting screws located as shown For the 30 76 2 cm and 36 91 4 cm models there are two mounting screws For the 42 106 7 cm and 48 121 9 cm models there are four mounting screws Install the screws into the wall until the screw heads are tight against the wall and horizontal Note The screws provided for mounting this range hood must be fastened into solid wood Do Not fasten into sheet rock only top of hood 12 9 16 12 9 16 31 9 cm 31 9 cm I 1
52. tes To locate the designated KitchenAid service company in your area you can also look in your telephone directory Yellow Pages If you need replacement parts If you need to order replacement parts we recom mend that you only use factory authorized parts These parts will fit right and work right because they are made to the same exacting specifications used to build every new KitchenAid appliance To locate factory authorized parts in your area call our Customer Interaction Center telephone number your nearest authorized service center or KitchenAid Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to KitchenAid with any questions or concerns at KitchenAid Brand Home Appliances Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence 11 Requesting Assistance or Service Before calling for assistance or service please check the Check Operation section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service in Canada 1 If the problem is not due to one of the items 2 If you need servicet listed in Check Operation Contact your nearest KitchenAid Canada Appli ance Service branch or authorized servicing outlet to service your appliance See list be
53. tilis e ajuster les levres de la garniture sur la bride Si l extension de chemin e est utilis e ajuster l extension sur les brides Assurer l tanch it entre extension et hotte avec du ruban adh sif pour conduit Raccordement au r seau lectrique A AVERTISSEMENT Risque de choc lectrique Interrompre l alimentation lectrique avant d effectuer des raccordements Connecter le conducteur de liaison a la terre avec la vis verte dans la boite de connexion Le non respect de ces instructions peut provoquer un choc lectrique ou un accident mortel 15 m Ex cution des raccordements lectriques Introduire le c ble d alimentation dans la bo te de connexion travers le connecteur de conduit homologation UL ou CSA Raccorder ensemble avec un connecteur de fils le conducteur blanc du c ble d alimentation et le conducteur blanc de la hotte raccorder ensemble avec un connecteur de fils le conducteur noir du c ble d alimentation et le conducteur noir de la hotte Connecter sous la vis verte le conducteur vert du c ble d alimentation utilis pour la liaison la terre Serrer les vis de bridage du connecteur de conduit R installer le couvercle de la bo te de connexion 16 Installer les filtres e Sortir les filtres de la bo te et enlever la pellicule de protection blanche des filtres Note Lors de l installation du filtre tirer faire tourner le bouton avec une main et
54. urfaces on this product To order call our Customer Service Center at 1 800 442 9991 or order on line at www applianceaccessories com and ask for part number 8171420 To order from Canada call 1 800 807 6777 e f commercial cleaners are used follow label directions Do not use products that contain chlorine bleach Chlorine is a corrosive substance For routine cleaning and fingerprints use liquid detergent soap and water or all purpose cleaner Wipe with damp cloth or sponge then rinse with clean water and wipe dry Installation kits available from your dealer Optional Installation Kits available from your dealer Note Kits are available in stainless steel only Backsplash Must be installed before hood is installed 30 76 2 cm hood Kit No 8285148 36 91 4 cm hood Kit No 8284756 42 106 7 cm hood Kit No 8284827 48 121 9 cm hood Kit No 8284755 Vent covers 12 30 5 cm high 12 30 5 cm deep 30 30 76 2 cm hood Kit No 8285149 36 91 4 cm hood Kit No 8284753 106 7 cm hood Kit No 8284828 48 48 121 9 cm hood Kit No 8284752 42 Kit No 8284754 Chimney extensions extends from 12 30 5 cm to 23 58 4 cm high For use with 30 76 2 cm 36 91 4 cm 42 106 7 cm and 48 121 9 cm hoods Vent transition transitions from two 3 1 4 x 10 36 42 ao 8 3 x 25 4 cm vents to one 10 25 4 cm round vent Not for use with chimney extension Kit No 8284754

Download Pdf Manuals

image

Related Search

Related Contents

RCS36-23lgs manual.indd  User Manual - Witura Technology Sdn Bhd  TARIF {PUBLIC  Protexfer brillant  ZSX  Operation & Installation Manual 05/2009  Samsung SGH-F480I Kullanıcı Klavuzu  TiVo tivo dvr DVR User Manual  SC 1332  Eglo 30907  

Copyright © All rights reserved.
Failed to retrieve file