Home

Kingston Technology Switch KND2415TX User's Manual

image

Contents

1. Three Year Warranty The following Kingston products are covered by this warranty for a period of three years from the date of original retail purchase networking hubs with cooling fans including the power supply Two Year Warranty The following Kingston products are covered by this warranty for a period of two years from the date of original retail purchase Solid State Floppy Disk Cards SSFDC and Winchester hard disk drives in a 2 5 inch 3 5 inch or 5 25 inch form factor One Year Warranty The following Kingston products are covered by this warranty for a period of one year from the date of original retail purchase Winchester hard disk drives in a 1 8 inch form factor optical storage products and magnetic tape storage products Rev 3 99 Kingston Technology Company KND2415TX User s Guide Rev 00 Appendix F Warranties and Notices 19 Warranty Claim Requirements To obtain warranty service return the defective product freight prepaid and insured to your local authorized Kingston dealer or distributor or to the Kingston factory service center located at 17600 Newhope Street Fountain Valley California 92708 U S A You must include the product serial number if applicable and a detailed description of the problem you are experiencing You must also include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period If you return the product directly to the Kingsto
2. 13 Appendix C Specifications 14 Appendix D Commonly Asked Questions 15 Appendix E Mounting Templates 17 Appendix F Product Warranties and Notices 18 Limited Warranty Statement 18 Duration of Warranty 18 Warranty Claim Requirements 19 Free Technical Support 19 Wie i een ec 19 F C C Certification 20 20 C Tick Certification 20 KND2415TX Users Guide Rev A00 Kingston Technology Company Kingston Technology Company KND2415TX User s Guide Rev A00 Introduction 1 Introduction Intended Audience This manual assumes that the user has a general working knowledge of networking principles and is familiar with network systems in general Congratulations on the purchase of your Kingston Fast EtheRx Stackable 10 100TX Rack Mountable Dual Speed hub The KND2415TX is a full 19 rack mount unit The Fast EtheRx Stackable 10 100TX Dual Speed hub conforms to IEEE802 3u 100BASE TX IEEE802 31 10BASE T and IEEE802 3 CSMA CD standards A maximum of four KND2415TX units can be stacked together IMPORTANT The KND2415
3. Fig 3 2 Rear Panel KND2415TX Users Guide Rev A00 Kingston Technology Company 6 Hardware Installation Power Switch The AC Power switch turns the unit ON or OFF Ifthe PWR LED does not light up once the unit has been turned on try the procedures below in the following order l Try a different AC power outlet 2 Check the external fuse located at the back of unit below the AC power connector Ifthe fuse is blown replace it with the spare fuse provided with the unit See Fuse Compartment display in Figure 3 3 3 The power supply may be defective Return the unit for replacement WARNING For safety reasons DO NOT attempt to open and service the unit There are no user serviceable components inside AC Power Connector The Fast EtheRx dual speed hubs use 100 240VAC internal power supplies Connect the AC power cord from the back of the unit to an AC electrical outlet Fuse The Fast EtheRx dual speed hub comes equipped with one external fuse and one spare fuse Both fuses are in a fuse holder located just below the AC power connector on the back of the unit Both fuses are rated 250V 2A max 100 240 50 60Hz IA Fig 3 3 Fuses Fan Unit s The Fast EtheRx dual speed hubs use independent cooling fans for optimum air flow to safeguard the unit from unnecessary heat exposure Kingston Technology Company KND2415TX User s Guide Rev A00 Hardware Installation 7 Stack In Stac
4. collision detection Power LED for power status e Automatic port partitioning reconnection e Uplink port that supports both crossover and straight through cable wiring e nternal auto sensing power supply operating at 100 240VAC 50 60Hz e Desktop or rack mountable Package Contents The Fast EtheRx Dual Speed package should contain the following items KND2415TX Dual Speed Hub 50 pin Shielded Stacking Cable AC Power Cord Mounting kit including 2 Angle Brackets 8 Mounting Bracket Screws 4 10 32 Rack Mount thumb screws 4 Rubber feet J User s Guide OOOO If any of the items are missing or damaged please contact your Kingston dealer for a replacement Be sure the items you receive are genuine Kingston Technology products If the Kingston name and logo are not on the front panel of the unit it s not a genuine Kingston product Kingston Technology Company KND2415TX User s Guide Rev A00 Design Features 3 Design Features The Fast EtheRx dual speed hub complies with the full set of repeater basic functions as defined by IEEE802 3u 100BASE TX IEEE802 31 IOBASE T and IEEE802 3 CSMA CD standards Repeater Functions If any single port senses the start of a valid packet on its receiving line the dual speed hub will re transmit the received data to all other ports on the network The re transmission of packets complies with the IEEE 802 3 specification in terms of preamble structure voltage
5. pliable and generally targeted for patch cables For proper termination use the correct RJ 45 connector as they differ for each type of cable UTP Cable Wiring UTP cables are wired based on one of two standard pin configurations Straight Through and Cross Over 100BASE TX uses only Category 5 UTP cables with four pairs of wire as illustrated below in Tables B 2 and B 3 Straight Through Cross Over Configuration Configuration IR 1 TRX 2 TRX Not Used Table B 2 Straight Through Wiring Table B 3 Cross Over Wiring KND2415TX Users Guide Rev 400 Kingston Technology Company 12 Appendix B Cabling Guidelines UTP Cable Wiring Standards There are two governmental agencies the Electronic Industry Association EIA and the Telecommunications Industry Association TIA which set the standard for all cable wiring requirements for commercial buildings With the advent of 100Mb s networking products it is best to use higher quality CAT 5 cables like Belden or Helix as well as CAT 5 compliant patch panels patch cables and connectors while following the EIA TIA wiring standards 100 W UTP CAT 5 type cables use 4 pair UTP wiring Refer to the illustrations below for 4 pair wiring using either T568A Fig B 1 or T568B Fig B 2 wiring standards Both T568A and T568B wiring 1s compatible with IOBASE T and 100BASE TX and require no special configurations but for premise wiring stick to one wiring standard Mixing T568A
6. resistant to the spread of fire and pass the UL 1581 Vertical Tray Flame Test MP MPR amp MPP Within Article 800 the Multi purpose Cables Category allows conditional substitutions between different cable types amp are restricted by number AWG size and stranding of the cable conductors Terms You Should Be Familiar With l BACKBONE WIRING The physical electrical interconnections between telecommunications closets and equipment rooms COMPLIANCE A wiring device that meets all characteristics of a standard is said to be in compliance with that standard PREMISE WIRING The entire wiring system on the premises especially the supporting wiring that connects the communications outlets to the network interface Jack NEAR END CROSSTALK NEXT In wires packed together within a cable the signals generated at one end of the link can flush out the weaker signals coming back from the recipient KND2415TX Users Guide Rev A00 Kingston Technology Company 14 Appendix C Specifications Appendix C Specifications Compliance Media Interface Connector Type Cable Type Cable Grade IOBASE T 1000BASE TX Max Segment Length Number of Segments Inter repeater Link Number of Repeaters Cable Length Diagnostic LEDs Additional Stacking Stacking Cable Uplink Port Environmental Operating Temperature Storage Temperature Relative Humidity Electrical Input AC Voltage Output DC Volt
7. Class in a maximum length segment topology only one Class D repeater may exist between any two nodes within a single collision domain Class D in a maximum length segment topology two Class D repeaters may exist between any two nodes within a single collision domain Will 100BASE TX run on Category 3 cable No Category 3 CAT 3 cabling even in short lengths generates too much near end crosstalk for 100 networks The IEEE 802 3u 100BASE TX Fast Ethernet standard requires Category 5 100 W UTP or 100 W STP which complies with ISO TEC 11801 1995 What is Category 5 Category 5 CAT 5 is a further extension of the EIA TIA 568 cabling system to 100 MHz Category 5 components 1 e UTP trunk and patch cables modular plug and patch panel etc are defined by EIA TIA 568 but with the characterizations extended to 100 MHz by TSB 36 and TSB 40 The cable grades are categorized as follows Category 3 up to 16 MHz Category 4 up to 20 MHz Category 5 up to 100 MHz Category 5 Compliance vs Category 5 Performance Having CAT 5 components in your network installation does not necessarily achieve full Category 5 performance To achieve any category rated performance make sure all cabling components are at least of the minimum category required To achieve full CAT 5 performance all components must be CAT 5 compliant and terminated properly according to EIA TIA 568 TSB 36 and TSB 40 guidelines KND2415TX Us
8. KINGSTON TECHNOLOGY FAST ETHERX STACKABLE 24 PORT 10 100TX RACK MOUNTABLE DUAL SPEED HUB USER S GUIDE MODEL KND2415TX Kingston Technology s Fast EtheRx Stackable 10 100TX Rack Mountable Dual Speed Hub User s Guide Part No 4460174 001 A00 Kingston PER I P HE RA LL S Kingston Technology Company 17600 Newhope Fountain Valley CA 92708 714 435 2600 www kingston com KND2415TX Users Guide Rev A00 Kingston Technology Company Important Safety Instructions I 2 3 4 5 Read all these instructions Save these instructions for later use Follow all warnings and instructions marked on the product Do not use this product near water This product should be operated from the type of power source indicated on the marking label If you are not sure of the type of power available consult your dealer or local power company Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage points or other risk Refer all servicing to service personnel Wichtige Sicherheitshinweise I 2 Diese Hinweise sollten vollst ndig durchgelesen werden Diese Hinweise f r einen sp teren Gebrauch aufbewahren Allen auf dem Ger t angebrachten Warnungen und Hinweisen folgen Das Ger t nicht in der N he von Wasser verwenden Das Ger t nur mit dem Aufkleber bezeichneten Netzspannung betreiben Bei Fragen ber die Art der Netzspannung sollte de
9. Panel 100TXLEDs Link Activity LEDs PowerLED Collision LEDs 10 100BASE TX Uplink Port for 10 and 100 UTP Ports Fig 3 1 Front Panel Power LED The green LED indicates the power status The LED will light up when the AC power connector is properly connected to a power source Collision LEDs There are two 2 separate collision LEDs for both 10Mbps and 100Mbps segments If a collision is detected on a 10Mbps segment the 10 LED will flash amber If a collision is detected on a 100Mbps segment the 100 LED will flash amber Collisions occur when 2 or more ports receive data simultaneously 100TX Speed Detection LEDs The 100TX LED lights up when 100Mbps operation is detected The 100TX LED will not light up if 10Mbps operation is detected Link Activity LEDs The LINK ACTIVITY LEDs service both IOBASE T and 100BASE TX operation A steady green light indicates that a good link has been established A flashing green light indicates that data 1s being received If the Link LED does not display a steady green link light please check the following l Make sure the power is turned on for both the PC and EtheRx hub 2 Verify that the correct network drivers have been loaded on the PC Some network adapters require the drivers to be loaded to establish a proper link 3 Make sure the correct cable type is selected Kingston Technology Company KND2415TX User s Guide Rev A00 Ha
10. TX can only be stacked with other KND2415TX units Stacking the unit with any other model hub may cause damage to the units For ease of installation the Fast EtheRx Stackable Dual Speed hub offers twenty four 24 UTP ports that auto negotiate 10 100Mbps operation and an uplink port that allows the last UTP port on the hub to support both crossover and straight through cabling Ideal for inter connecting IOBASE T Ethernet networks with 100BASE TX Fast Ethernet networks the Fast EtheRx Dual speed hubs can also be used as simple stand alone 10BASE T or 100BASE TX repeaters For easy trouble shooting the front panel includes a variety of diagnostic LEDs such as Power Collision for 10Mbps and 100Mbps 100TX Link and Activity status Fig 1 1 KND2415TX KND2415TX Users Guide Rev A00 Kingston Technology Company 2 Special Features Special Features Conforms to IEEE802 3u 100BASE TX IEEE802 31 10BASE T and IEEE802 3 CSMA CD standards Inter connects IOBASE T Ethernet networks with 100BASE TX Fast Ethernet networks e Works as a simple 100 or IOBASE T repeater 10 100BASE TX Class compliant repeater Stacking ports for stacking up to four 4 hubs maximum e 24 UTP ports that auto negotiate 10 100TX operation e 24100TX LEDs for 100Mbps speed detection e 24 Link Activity status LEDs for easy troubleshooting e Individual collision LEDs for both 10Mbps 100Mbps
11. age Power Consumption Physical Dimension HxWxD Weight Certification EMI Standards EMC Standards Low Voltage Directive Safety Standards Kingston Technology Company IEEE 802 3u 100BASE TX Standard IEEE 802 31 10BASE T Standard IEEE 802 3 CSMA CD Ethernet Standard 24 auto negotiating 10 100 Mbps UTP Ports Female RJ 45 UTP 26 to 22 AWG CAT 3 4 5 or better CAT 5 or better 100 meters 328 feet 2 segments 10 Mbps or 100 Mbps 2 Class II repeaters max 5 meters 16 4 feet max between repeaters O 1 LED for Power Indicator steady green 1 LED for 10 Mbps Collision Detection flashing amber Q O 1 LED for 100 Mbps Collision Detection flashing amber Q 24 LEDs for 100BASE TX Speed Detection steady green Up to 4 max 50 pins shielded cable Port 24 supports cross over or straight through cabling 0 C to 45 C 32 F to 113 F 20 C to 60 C 4 F to 140 F 10 to 90 non condensing 100VAC to 240 VAC 50Hz 60Hz Auto sensing 5VDC 8A 19 20 Watts max 1 70 x 17 32 x 7 90 43 2mm x 440mm x 200 6mm 6 2 lbs 2 81 kg FCC Class A CE CISPR A C Tick EN55022 IEC801 2 IEC801 3 IEC801 4 EN60950 UL cUL TUV KND2415TX User s Guide Rev A00 Appendix D_Commonly Asked Questions 15 Appendix D Commonly Asked Questions Class vs Class D 100BASE TX Fast Ethernet Repeaters There are currently two classes of Fast Ethernet repeaters defined as Class D and Class D
12. amplitude and timing characteristics Auto Negotiation Auto Negotiation provides the means of automatically establishing a link by detecting the link capabilities of the connected device on the network to select the best operational mode available 1 e 10 100Mbps selection Receive Jabber Protection The dual speed hub uses a Receive Jabber Protection scheme to ensure that the network is not disabled due to reception of excessively long data packets Collision Handling The dual speed hub will detect and respond to collision conditions as outlined in the IEEE 802 3 specifications Error Handling With 100BASE TX Fast Ethernet the new error handling feature prevents sub standard links from generating streams of false carrier and interfering with other links Automatic Port Partitioning Reconnection If any ofthe ports on the dual speed hub experience excessive collisions or faulty conditions that particular port can be partitioned Once partitioned the hub will continue to monitor that port If the error conditions have been corrected or a good data packet is received or transmitted without a collision the hub will automatically reconnect that port to the network KND2415TX Users Guide Rev A00 Kingston Technology Company 4 Hardware Installation Hardware Installation Before you begin installing network cables please take a few minutes to familiarize yourself with the dual speed hub See the diagram below Front
13. and T568B wiring schemes may cause or lead to potential problems a 2 e 3 UA lm 4 N er PA 4 12345678 12345678 T568A T568B Fig B 1 4 Pair T568A Wiring Fig B 2 4 Pair T568B Wiring Soli Soli White Green White Orange Green White Orange White Pind Part Red Blue White Pin Pari Red Blue White White Blue White Blue Orange White Green White White Brown White Brown Table B 4 4 Pair T568A Wiring Table B 5 4 Pair T568B Wiring Kingston Technology Company KND2415TX User s Guide Rev A00 Appendix B Cabling Guidelines 13 UTP Cable Rating Codes UTP cables meet different UL NEC requirements based on cable Jacket quality Below is an explanation of the rating codes for each cable type UL The National Electrical Code NEC published by the National Fire Protection Association NFPA details advisory safety considerations for electrical wiring NEC Article 800 Communications Cables are manufactured to meet these different cable types l CMP Cables meeting type CMP requirements are suitable for installation in ducts and plenums without the use of conduit These cables are designed for fire resistance and low smoke producing characteristics CMR Riser type cables are engineered to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications CM Cables for general building wiring CM cables are used in areas other than plenums and risers These cables are
14. any unauthorized disassembly repair or modification Duration of Warranty Lifetime Warranty The following Kingston products are covered by this warranty for life memory modules and expansion boards networking adapters networking hubs without cooling fans excluding the power supply and microprocessor upgrade products Seven Year Warranty The following Kingston products are covered by this warranty for a period of seven years from the date of original retail purchase all core storage enclosures including the power supply cables terminators and related accessories Under certain agreements where core products are slightly modified e g paint handle etc by Kingston at the customer s request the product will be covered for a period of seven years for repair only Storage products that are custom designed and or incorporate component level modification by Kingston in order to meet specific customer requests will be negotiated with the applicable customer on a per case basis Five Year Warranty The following Kingston products are covered by this warranty for a period of five years from the date of original retail purchase the power supply in networking hubs without cooling fans Flash memory cards e g CompactFlash ATA Flash and Linear Flash solid state PC Card PCMCIA adapters PC Card Readers and all other Kingston products other than those products covered by a three year two year or one year warranty as provided below
15. chnology Company 10 Appendix A Pin Assignments Appendix A Pin Assignments UTP Port Pin Assignments UTP Ports use RJ 45 Unshielded Twisted Pair UTP cabling RJ 45 modular plugs and their pin numbers and wiring assignments are listed below Twisted Pair cables can be wired with either Straight Through or Crossover pin assign ments Both wiring schemes are mentioned in Appendix B Cabling Guidelines for reference in creating a twisted pair cable 12345678 Modular Connector Fig A 1 RJ 45 Connector Pin Numbers MDI X gt lt Transmit Data Transmit Data Receive Data Not Used 6 TransmitData Receive Data Not Used Table A 1 UTP Pin Assignments NOTE For further details refer to Notes on MDI amp MDI X on page 5 Kingston Technology Company KND2415TX User s Guide Rev A00 Appendix B Cabling Guidelines 11 Appendix B Cabling Guidelines UTP Cable Type When installing network cables the following table shows appropriate cabling guidelines for 100BASE TX Fast Ethernet architecture Cabling Components 100BASE TX Trunk and Patch Cable Type 4 Pair 10082 UTP CAT 5 only 2 pairs used Modular Plug 8 Pin RJ 45 CAT 5 only Patch Panel 8 Pin RJ 45 CAT 5 only Table B 1 Network Cable Guidelines NOTE All UTP cables come in both solid and stranded filament Solid filament cables are more rigid and usually intended for trunk cabling Stranded filament cables are more
16. ers Guide Rev A00 Kingston Technology Company 16 Appendix D_Commonly Asked Questions What are the Guidelines for Proper Termination It is important to maintain the twists of the cable as close to the termination on the outlet as possible to avoid NEXT Near End Cross Talk and to maintain the transmissions characteristics of the Category Category specifications require that pair twisting be maintained to within the following distances from the outlet termination Category 3 maximum allowed untwisting 3 inches Category 4 maximum allowed untwisting 1 inch Category 5 maximum allowed untwisting 1 2 inch Can mix CAT 3 and CAT 5 cabling in the same building Yes but keep in mind you will not have CAT 5 performance It is a good idea to keep the lines separated when installing any new lines Use CAT 5 UTP cabling only Can a Four Pair CAT 5 cable support two 100BASE TX devices Although only two pairs are used in the standard four pair CAT 5 UTP cable it is not recommended because it exceeds the specifications outlined by IEEE 802 3u Kingston Technology Company KND2415TX User s Guide Rev A00 Appendix E Mounting Templates 17 Appendix E Mounting Templates The Fast EtheRx dual speed hubs can be stationed on a flat surface using the four rubber feet provided or mounted in a standard 19 rack by using the mounting brackets and 4 thumb screws provided with the unit Rubber Feet for Desktops The Fast EtheRx d
17. k Out Ports Fig 3 4 Stacking Configuration The Fast EtheRx stackable hub uses stacking ports located on the back of the unit to stack up to a maximum of four hubs IMPORTANT The KND2415TX can only be stacked with other KND2415TX units Stacking the unit with any other model hub may cause damage to the units Follow the directions below on stacking these hubs together l Power down the Fast EtheRx hub s 2 Locate the 50 pin shielded stacking cable included with your package contents 3 Plug one end of the cable into the port labeled Stack Out on the first hub 4 Plug the other end of the cable into the Stack In port on the second hub 5 Repeat steps 2 through 4 for stacking up to a maximum of four 4 hubs Kingston s Stack n PlayTM feature offers greater scalabilty to add UTP ports without the need to configure ID or termination switches When configured as a stack the Fast EtheRx stackable hubs are recognized as a single unit on the network By stacking hubs together you can expand the total number of UTP ports up to 96 ports KND2415TX Users Guide Rev A00 Kingston Technology Company Kingston Technology Company KND2415TX User s Guide Rev A00 Appendices 9 Appendices KND2415TX Users Guide Rev A00 Kingston Te
18. n factory you must first obtain a Return Material Authorization number by calling Kingston Customer Service at 714 438 1810 and include the RMA number prominently displayed on the outside of your package Products must be properly packaged to prevent damage in transit Free Technical Support Kingston provides free technical support If you experience any difficulty during the installation or subsequent use of a Kingston product please contact Kingston s Technical Support department prior to servicing your system Kingston Technical Support can be reached in the U S at 714 435 2639 or toll free at 800 435 0640 U S and Canada only Kingston European Technical Support can be reached from within Europe at 00800 8123 8123 or by fax at 00800 8823 8823 This warranty covers only repair or replacement of defective Kingston products as provided above Kingston is not liable for and does not cover under warranty any costs associated with servicing and or the installation of Kingston products Disclaimers The foregoing is the complete warranty for Kingston products and supersedes all other warranties and representations whether oral or written Except as expressly set forth above no other warranties are made with respect to Kingston products and Kingston expressly disclaims all warranties not stated herein including to the extent permitted by applicable law any implied warranty of merchantability or fitness for a par
19. r H ndler oder dasEnergieversorgungsunternehmen zu rate gezogen werden Nicht versuchen das Produkt selbst zu reparieren In allen Produkten existieren gef hrliche elektrische Spannugen Nicht das Geh use ffnen Kingston Technology Company KND2415TX User s Guide Rev A00 111 TABLE OF CONTENTS V LI UO E RE ai ee eek 1 See ee ee ee 2 Package 2 Design Feat resS een 3 Hardware Installation einen A Front Panel uuu uu u u 4 4 Collision LEDS 4 100TX Speed Detection LEDS 4 Link Activity LEDS u uu ee 4 10 100TX UTP Ports 5 ON coset vent u uuu r Ea riai 5 Rear gt uuu ne ee 9 POWER SWICh ee ee een 6 AC Power Connector 6 6 Fan Uni een ea 6 Stack In Stack Out Ports 7 Appendices Appendix A Pin Assignments 10 Appendix B Cabling Guidelines 11 UIF Cabe Typ ET 11 UTP Cable Wiring 11 UTP Cable Wiring Standards 12 UTP Cable Rating
20. rdware Installation 5 4 Make sure the cable is wired properly and connected on both ends 5 If steps 1 through 4 are correct the cable may be defective or not wired correctly Please refer to Appendix A for pin assignments and Appendix B for cabling guidelines 10 100TX UTP Ports The twenty four 24 10 100TX UTP ports auto negotiate both 10 and 100BASE TX connections All ports like all normal hub ports are configured as MDI X However port 24 supports both MDI X and MDI port configuration Uplink Port The uplink port provides cabling flexibility on UTP port 24 for connecting to a workstation NIC or cascading to another hub Although these ports have two 2 UTP connections MDI and MDI X only one port may be used Notes on MDI and MDI X Ports MDI Media Dependent Interface is the standard that defines the mechanical and electrical configuration of a UTP port For any two devices to communicate with each other the transmitter of one device must be connected to the receiver of the other device Switch Port For Connection to For Connection to a Position Configuration another Hub Port MDI X Network Adapter MDI MDI X Use Crossover Cable ur a nen Use Straight Through Use Crossover Cable Cable Table 3 1MDI amp MDI X Configuration Rear Panel Power AC Power Switch Connector 100 240Vhc 50 60Hz IA Stack in Stack Out Ports Fan Fuse 250V 2A
21. t of radio interference characteristics L EN50082 1 Electromagnetic Compatibility generic immunity standard IEC 801 2 Electrostatic discharge requirements IEC 801 3 Radiated immunity requirements IEC 801 4 Electrical fast transient requirements EN60950 Low Voltage Directive LVD Declaration of CE Conformity in accordance with the above standards has been made and is on file at Kingston Technology C C Tick Certification L AS NZS 3548 Information Technology Equipment L Declaration of C Tick Conformity in accordance with the above standards has been made and is on file at Kingston Technology N1298 Kingston Technology Company KND2415TX User s Guide Rev A00
22. ticular purpose In no event will Kingston be liable to the purchaser or to any user of the Kingston product for any damages expenses lost revenues lost savings lost profits or any other incidental or consequential damages arising from the purchase use or inability to use the Kingston product even if Kingston has been advised of the possibility of such damages Rev 3 99 Copyright 2000 Kingston Technology Company All rights reserved Printed in Taiwan Kingston Technology and the Kingston logo are trademarks of Kingston Technology Company All other logos and trademarks are properties of their respective companies KND2415TX Users Guide Rev A00 Kingston Technology Company 20 Appendix F Warranties and Notices F C C Certification This device has been tested and found to comply with limits for Class B digital device pursuant to Part 15 ofthe FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation CE Notice The official CE symbol indicates compliance of this Kingston Technology product to the EMC directive of the European Community The CE symbol indicates that this Kingston product meets or exceeds the following standards L EN50081 1 Electromagnetic Compatibility generic emissions standard EN55022 Limits and methods of measuremen
23. ual speed hubs come with rubber feet that may be applied to the bottom of the unit for desktop surface installations The 4 rubber feet have peel off adhesive backing Remove the backing and attach the feet to the bottom of the switch Brackets for Rack Mounting The Fast EtheRx dual speed hubs can also be mounted in a standard 19 rack using the brackets included with the unit A rack mount installation uses a standard 19 dimension Align the holes in the brackets with the holes on each side of the unit Use the 8 screws provided to secure the brackets to the Fast EtheRx dual speed hub See Figure E 1 below Fig E 1 Attaching the Mounting Brackets KND2415TX Users Guide Rev A00 Kingston Technology Company 18 Appendix F Warranties and Notices Appendix F Warranties and Notices Limited Warranty Statement KINGSTON TECHNOLOGY COMPANY Kingston warrants that this product is free from defects in material and workmanship Subject to the conditions and limitations set forth below Kingston will at its option either repair or replace any part of this product which proves defective by reason of improper workmanship or materials Repair parts or replacement products will be provided by Kingston on an exchange basis and will either be new or refurbished to be functionally equivalent to new This warranty does not cover any damage to this product that results from accident abuse misuse natural or personal disaster or

Download Pdf Manuals

image

Related Search

Related Contents

  ARMA-GEL-PLUS  MANUAL DE INSTRUCCIONES  ®artscher  PTV-2000S - Migros    Dvm13mfc2 GB-NL-FR-ES-D-I  Nytro™ XM vCenter Plug-In User Guide  MX-4157 - ZemaKaina.lt    

Copyright © All rights reserved.
Failed to retrieve file