Home

Kidde P9050 User's Manual

image

Contents

1. and a maximum of 12 30 5cm below the ceiling see figure 1 e Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 ft 9 1m long e Install Smoke Alarms on sloped peaked or cathedral ceilings at or within 3 ft 0 9m of the highest point measured hori zontally NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4m horizontally shall be located on the high side of the room NFPA 72 states A row of alarms shall be spaced and located within 3 ft 0 9m of the peak of the ceiling measured horizontally see figure 3 be dem l CEILING minimum ANYWHERE NEVER 4 M02 mm AREA HERE BEST HERE ACCEPTABLE gt HERE FIGURE 1 MULTIPLE ANYWHERE ale Sa SINGLE FLOOR PLAN FLOOR PLAN IN THIS AREA F an BEDROOM Smoke Alarms for Minimum Protection O Smoke Alarms for Additional Protection A ionization Type Smoke Alarms with Hush Control or Photoelectric Type FIGURE 2 FIGURE 3 MOBILE HOME INSTALLATION odern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above refer to RECOMMENDED LOCATIONS and figures 1 and 2 n older mobile homes that are not well insulated compared to present standards extreme heat or cold can be transferred from he outside to the inside through poorly insulated walls and roof This may
2. even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of pos sible fires at a reasonable cost however alarms have sensing limitations lonization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photo electric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms Home fires develop in different ways and are often unpredictable For maximum protection Kidde recom mends that both lonization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batter ies and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor If the alarm is located outside the bedroom or on a different floor it may not wake up a sound sleeper The use of alcoh
3. accordance with the National Fire Protection Association s Standard 72 NFPA Batterymarch Park Quincy MA 02269 NOTIFY YOUR LOCAL FIRE DEPARTMENT AND INSURANCE COMPANY OF YOUR SMOKE ALARM INSTALLATION 10 CAUTION AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the house hold as follows A smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitch ens hallways attics furnace rooms closets utility and storage rooms basements and attached garages 11 SERVICE AND WARRANTY If after reviewing this manual you feel that your smoke alarm is defective in any way do not tamper with the unit Return it for servicing to KIDDE Safety 1016 Corporate Park Dr Mebane NC 27302 1 800 880 6788 See Warranty for in warranty returns TEN YEAR LIMITED WARRANTY KIDDE Safety warrants to the original purchaser that the enclosed smoke alarm but not the battery will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase The obligation of KIDDE Safety under this warranty is limited to repairing or replacing the smoke alarm or any part which we find to be defective in material workmanship or design free of ch
4. create a thermal barrier which can prevent the smoke rom reaching an alarm mounted on the ceiling In such units install the smoke alarm on an inside wall with the top edge of he alarm at a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling see figure 1 f you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alarm close to the bedrooms For additional protec ion see SINGLE FLOOR PLAN in figure 2 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER RV OR MOBILE HOME VEHICLE HAS BEEN IN STORAGE BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE 2 LOCATIONS TO AVOID e In the garage Products of combustion are present when you start your automobile Less than 4 10cm from the peak of an A frame type ceil ing e In an area where the temperature may fall below 40 F or rise above 100 F such as garages and unfinished attics e In dusty areas Dust particles may cause nuisance alarm or fail ure to alarm e In very humid areas greater than 85 R H Moisture or steam can cause nuisance alarms n insect infested areas Smoke alarms should not be installed within 3 ft 9m of the ollowing The door to a kitchen the door to a bathroom con aining a tub or shower forced air supply ducts used for heating or cooling ceiling or whole hou
5. ERTAIN A SAFE CONDITION EXISTS FLASHING LED LIGHT This smoke alarm is equipped with a flash ing red indicator light The light is located under the test button and will flash every 30 40 seconds to indicate that the smoke alarm is receiving power SMOKE SENSING CHAMBER OPERATION This alarm will chirp if any of the components in the smoke sensing chamber fail This chirp will occur between the flashes of the red LED indicator light If the chirp occurs at the same time as the red LED flash see sec tion 6 for low battery information TESTING Test by pushing the test button on the cover and hold ing it down for a minimum of 5 seconds This will sound the alarm if the electronic circuitry horn and battery are working If no alarm sounds the unit has defective batteries or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION Erratic or low sound coming from your alarm may indicate a defective alarm and it should be returned for service see section 12 NOTE WEEKLY TESTING IS REQUIRED 5 NUISANCE ALARMS Smoke alarms are designed to minimize nuisance alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area Large quantit
6. ERY USE A LONG NOSE PLIERS TO PULL THE PIN OUT OF THE HOLE IT IS NOW POSSIBLE TO REMOVE THE ALARM FROM THE MOUNTING PLATE 8 After installation test your alarm by depressing and holding down the test button for at least 5 seconds This should sound the alarm 4 OPERATION AND TESTING OPERATION The smoke alarm is operating once a fresh battery is installed and testing is complete When products of combustion are sensed the unit sounds a loud 85db pulsating alarm until the air is cleared HUSH CONTROL The HUSH feature has the capability of temporarily desensitizing the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is desensitized by pushing the HUSH button on the smoke alarm cover If the smoke is not too dense the alarm will silence immediately and the red LED will flash every 10 seconds for approximately 10 minutes This indicates that the alarm is in a temporarily desensitized condition The smoke alarm will automati cally reset after approximately 10 minutes and sound the alarm if smoke is still present The HUSH feature can be used repeatedly until the air has been cleared of the condition causing the alarm NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM CAUTION BEFORE USING THE ALARM HUSH FEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE C
7. For model P9050 Smoke Alarm User s Guide 9 Volt Battery Operated Photoelectric Smoke Alarm with HUSH Control to temporarily silence nuisance alarms Thank you for purchasing this smoke alarm It is an important part of your family s home safety plan You can trust this product to provide the highest quality safety protection We know you expect nothing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of alarm Date Code located on back of alarm The National Fire Protection Association NFPA and the manufacturer recommend replacing this alarm ten years from the date code Date of Purchase Where Purchased SIGNALING 21008148 EN Rev A 0305 7226 02 LISTED WARNING BATTERY DOOR WILL NOT CLOSE UNLESS BATTERY IS PRESENT REMOVAL OF BATTERY WILL RENDER THE SMOKE ALARM INOPERATIVE IMPORTANT READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE CONTENTS OF THIS MANUAL 1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 LOCATIONS TO AVOID 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 NUISANCE ALARMS 6 MAINTENANCE 7 LIMITATIONS OF SMOKE ALARMS 8 GOOD SAFETY HABITS 9 NFPA PROTECTION STANDARD 72 10 CALIFORNIA
8. GOLD PEAK 1604P OR 1604S Alkaline Type ENERGIZER 522 DURACELL MN1604 MX1604 GOLD PEAK 1604A PANASONIC 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type ULTRALIFE U9VL J NOTE WEEKLY TESTING IS REQUIRED WARNING USE ONLY THE BATTERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR To clean your alarm remove it from the mounting bracket as outlined in the beginning of this section You can clean the inte rior of your alarm sensing chamber by using compressed air or a vacuum cleaner hose and blowing or vacuuming through the openings around the perimeter of the alarm The outside of the alarm can be wiped with a damp cloth After cleaning reinstall your alarm and test your alarm by using the test button If clean ing does not restore the alarm to normal operation the alarm should be replaced 7 LIMITATIONS OF SMOKE ALARMS WARNING PLEASE READ CAREFULLY AND THOROUGHLY e NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need o escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal ires Victims are often intimate with the fire too old or young or physically or mentally impaired such that they cannot escape
9. OUNTING text and arrow are facing up Use the screws and anchors provided to secure the mounting plate use 3 16 drill bit for anchor holes 4 Battery installation instructions are provided on the inside of the battery door To ensure proper installation of the smoke alarm battery follow the instructions 5 When installing the battery press the battery reminder finger down into the battery compartment and install the battery see figure 6 CAUTION IF THE BATTERY REMINDER FINGER IS NOT HELD DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY THE BATTERY DOOR WILL NOT CLOSE AND THE UNIT WILL NOT ATTACH TO THE MOUNTING BRACKET 6 Alignment marks are provided on the edge of the trim plate and he alarm After installing the mounting plate place the alarm on the mounting plate with the alignment marks lined up Twist he alarm in the direction indicated by the ON arrow on the alarm cover see figure 7 until it locks in place 7 USING TAMPER RESIST LOCKING PIN To make your smoke alarm amper resistant a locking pin has been provided in the bag with the screws and anchors Using this pin will help deter children and others sy rom removing the alarm from the FIGURE8 Tamper Resist mounting plate To use the pin Locking Pin insert it into the hole in the side of he alarm after the alarm has been installed on the mounting plate see figure 8 NOTE THE TAMPER RESIST PIN WILL HAVE TO BE REMOVED IN ORDER TO CHANGE THE BATT
10. STATE FIRE MARSHAL REQUIRED INFORMATION 11 SERVICE AND WARRANTY 1 RECOMMENDED LOCATIONS FOR ALARMS e Locate the first alarm in the immediate area of the bedrooms Try to monitor the exit path as the bedrooms are usually farthest rom the exit If more than one sleeping area exists locate addi ional alarms in each sleeping area Locate additional alarms to monitor any stairway as stairways act ike chimneys for smoke and heat Locate at least one alarm on every floor level e Locate an alarm in every bedroom e Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers e Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction e For mobile home installation select locations carefully to avoid thermal barriers that may form at the ceiling For more details see MOBILE HOME INSTALLATION below e When mounting an alarm on the ceiling locate it at a minimum of 4 10cm from the side wall see figure 1 e When mounting the alarm on the wall use an inside wall with the top edge of the alarm at a minimum of 4 10cm
11. arge to the customer upon sending the smoke alarm with proof of date of purchase postage and return postage prepaid to Warranty Service Department KIDDE Safety 1016 Corporate Park Dr Mebane NC 27302 This warranty shall not apply to the smoke alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power THE LIABILITY OF KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILURE OF THE SMOKE ALARM OR FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY S NEGLIGENCE OR FAULT Since some states do not allow limitations on the duration of an implied warranty or do not allow the exclusion or limitation of incidental or con sequential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state Also KIDDE Safety makes no warranty express or implied written or oral including that of merchantability or fitness for any pa
12. ies of combustible particles are gener ated from spills or when broiling Using the fan on a range hood which vents to the outside non recirculating type will also help remove these combustible products from the kitchen If the alarm does sound check for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in section 2 may have caused the alarm The Model P9050 has a HUSH control that is extremely useful in a kitchen area or other areas prone to nuisance alarms For more information refer to section 4 OPERATION AND TESTING 6 MAINTENANCE BATTERY REPLACEMENT If tamper resist pin has been used refer to TAMPER RESIST LOCKING PIN in section 3 for removal instructions To replace the battery remove the alarm from the mounting plate by rotating the alarm in the direction of the OFF arrow on the cover see figure 7 The Model P9050 Smoke Alarm is powered by a 9V battery car bon zinc alkaline and lithium batteries may be used A fresh bat tery should last for one year under normal operating conditions This alarm has a low battery monitor circuit which will cause the alarm to chirp approximately every 30 40 seconds for a mini mum of seven 7 days when the battery gets low Replace the battery when this condition occurs USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM REPLACEMENT Carbon Zinc Type EVEREADY 1222
13. ional Fire Protection Association s Standard 72 provides the following information Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms Exception Smoke alarms shall not be required in sleeping rooms in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit includ ing basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are More Smoke Alarms Desirable The required number of smoke alarms might not provide reliable ear warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of addi tional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required smoke alarms The installation of the smoke alarms in the kitchen attic finished or unfinished or garage is normally not recommended as these locations occasionally experience condi tions that can result in improper operation y This equipment should be installed in
14. ol or drugs may also impair one s ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Although smoke alarms can help save lives by providing an early warning of a fire they are not a substitute for an insurance policy Home owners and renters should have adequate insur ance to protect their lives and property 8 GOOD SAFETY HABITS DEVELOP AND PRACTICE A PLAN OF ESCAPE e Make a floor plan indicating all doors and windows and at least two 2 escape routes from each room Second story windows may need a rope or chain ladder e Have a family meeting and discuss your escape plan showing everyone what to do in case of fire e Determine a place outside your home where you all can meet if a fire occurs Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it Practice a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your chil dren It is important they know what to do Install and maintain Fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have sho
15. rticular pur pose with respect to the battery The above warranty may not be altered except in writing signed by both parties hereto QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at www kidde com Kidde Fyrnetics Kidde 1016 Corporate Park Drive Mebane NC 27302
16. se ventilating fans or other high air flow areas e Kitchens Normal cooking may cause nuisance alarms If a kitch en alarm is desired it should have an alarm silence feature or be a photoelectric type e Near fluorescent lights Electronic noise may cause nuisance alarms e Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpose 3 INSTALLATION INSTRUCTIONS CAUTION THIS UNIT IS SEALED THE COVER IS NOT REMOVABLE When When wall mounting in 4 mounting the a hallway x A line should the A line ca D be horizontal should be ety 4 and the UP parallel with FOR WALL the hallway i MOUNTING FIGURE 4 FIGURE 5 arrow must be pointing up Alignment Marks S T k Remove FIGURE 6 FIGURE 7 1 Remove the mounting plate from the back of the alarm by hold ing the mounting plate and twisting the alarm in the direction indicated by the OFF arrow on the alarm cover 2 To insure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting plate should be parallel with the hallway when ceiling mounting or horizontal when wall mounting 3 After selecting the proper smoke alarm location as described in section 1 attach the mounting plate to the ceiling as shown in figure 4 For wall mounting see figure 5 Place mounting plate on the wall Be sure the UP FOR WALL M
17. wn smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or to those who may be incapable of safely evacuating the area unassisted WHAT TO DO WHEN THE ALARM SOUNDS e Alert small children in the home e Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables e In leaving don t open any inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in e Stay close to the floor if the air is smoky Breathe shallowly through a cloth wet if possible e Once outside go to your selected meeting place and make sure everyone is there e Call the fire department from your neighbor s home not from yours e Don t return to your home until the fire officials say that it is all right to do so e There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72 For instance a smoking in bed b leaving children home alone c cleaning with flammable liquids such as gasoline 9 NFPA REQUIRED PROTECTION The Nat

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SP-43R1HL User Manual  LRB 7x50  SMS Smart Media Solutions AE019020 project mount  ASUS M70AD TH8654 User's Manual  User`s Manual U User`s Manual  Philips HDMI cable SWV3434W    INVISIO 3S io  DINIC 1m IEEE 1394 a/b  Instructions de remise en état  

Copyright © All rights reserved.
Failed to retrieve file