Home

Kidde KN-COSM-IBCA User's Manual

image

Contents

1. For your convenience write down the following information If you call our consumer hotline these are the first questions you will be asked Alarm Model Number located on back of alarm Date of Manufacture located on the back of the alarm Date of Purchase Where Purchased Alarm Assembly Number located on the back of the alarm Maximum protection only an Interconnectable System can offer Every floor every living space any place where a crisis could begin needs the added security of an interconnectable life safety warning system ANY unit that senses a problem automatically triggers ALL units through out the home immediately allowing extra time for escape Installing the Interconnectable System is simple Unlike competitive products the Interconnectable System requires no complex wiring or relay switches to separate alarms Just direct connect and you re done This Smoke amp CO Alarm interconnects with up to 24 devices directly Use with Kidde Pro Fyrnetics and Lifesaver Smoke Alarms including 1235CA Series 1285CA Series PI2000CA KN COSMICA 1275CA Series PE120CA HD135 KN COSMIBCA For more information about compatible interconnect units and their functionality in an interconnect system visit our web site at www kidde ca Kidde 130 Esna Park Drive Markham ON L3R 1E3 Consumer Hotline 1 800 880 6788 www kidde ca Custom Assembled in China with U S and Foreign C
2. button resets the memory The memory is also reset when the unit loses power 17 Operation LED Indicators Red LED The Red LED flashes in conjunction with the alarm The red LED will flash during a smoke alarm a CO alarm a Low Battery Mode chirp and a Unit Error Mode chirp Green LED The green LED will flash under the following conditions In Standby Condition powered by AC and battery backup the green LED will be constantly on indicating that 120 V AC power is being delivered to the alarm It will breifly flicker every 30 seconds when a CO reading is taken For model KN COSM IBCA only in Standby Condition powered only by battery backup the green LED will flash every 5 seconds In Alarm Memory Condition the green LED will flash every second signifying that the alarm has sensed a smoke or CO hazard It will continue to flash every second until the Test Reset Hush button is pressed to reset the alarm When interconnected alarms cease to sound this flashing green LED indicates the originating alarm that triggered all the others in the circuit thus reducing the time spent troubleshooting While in Hush Mode the green LED will flash every 2 seconds Operation TAMPER RESIST FEATURE Location of Posts Tamper Resist Feature To make the Smoke CO alarm somewhat tamper resistant a tamper resist feature has been provided Activate the tamper resist feature by breaking off the four po
3. alcohol based products paints thinner solvents adhesives hair spray after shave perfume and some cleaning agents Carbon Monoxide Safety General CO Information Carbon monoxide CO is a colorless odorless and tasteless poison gas that can be fatal when inhaled CO inhibits the blood s capacity to carry oxygen Symptoms of CO Poisoning The following symptoms are related to carbon monoxide poisoning and should be discussed with ALL members of the household Mild Exposure Headaches running nose sore eyes often described as flu like symptoms Medium Exposure Dizziness drowsiness vomiting Extreme Exposure Unconsciousness brain damage death The above levels of exposure relate to healthy adults Levels differ for those at high risk Exposure to high levels of carbon monoxide can be fatal or cause permanent damage and disabilities Many cases of reported carbon monoxide poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets may be the first affected Familiarization with the effects of each level is important Carbon Monoxide Safety Initial carbon monoxide poisoning symptoms are similar to the flu with no fever and can include dizziness severe headaches nausea vomiting and disorientation Everyone is susceptible but experts agre
4. frame ceilings or gabled roofs Keep out of damp and humid areas Do not place near a diaper pail Install at least 30 5 cm 12 away from fluorescent lights as electronic noise may cause nuisance alarms Do not place in direct sunlight and keep out of insect infested areas Extreme temperatures will effect the sensitivity of the Smoke CO Alarm Do not install in areas where the temperature is colder than 4 4 C 40 F or hotter than 37 8 C 100 F Do not install in areas where the relative humidity RH is greater than 85 Place away from doors and windows that open to the outside 11 Installation Wiring Wiring Requirements This Smoke CO Alarm should be installed on a CSA listed or recognized junction box All connections should be made by a qualified electrician and must conform to codes having jurisdiction in your area The appropriate power source is 120 V AC Single Phase supplied from a non switchable circuit which is not protected by a ground fault interrupter The alarm should not be operated on power derived from a square wave or modified square wave inverter These power sources produce high peak voltages that will damage the alarm Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpose Wiring For AC Quick Connect Harness CAUTION Turn off the main power to the circuit before wiring the alarm For alarms
5. date of purchase postage and return postage prepaid to Kidde Customer Service Department 130 Esna Park Drive Markham ON L3R 1E3 This warranty shall not apply to the alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC power Any implied warranties arising out of this sale including but not limited to the implied warranties of description merchantability and fitness for a particular purpose are limited in duration to the above warranty period In no event shall Kidde be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in tort or otherwise Kidde shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of any kind resulting from gas leakage fire or explosion Since some provinces do not allow limitations of the duration of an implied warranty or do not allow the exclusion or limitation of incidental or consequential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from province to province 31 32 Also Kidde makes no warranty express or i
6. is not removable To replace the battery you must first remove the alarm from the mounting plate by following the Alarm Removal instructions above After the alarm has been removed you can open the battery door and replace the battery Battery installation instructions are provided on the inside of the battery door When installing the battery press the battery reminder tab down into the battery compartment and install the battery see Figure 4 20 Battery Replacement For model KN COSM IBCA only FIGURE 4 BATTERY REPLACEMENT CAUTION If the battery reminder tab is not held down in the battery compartment by the battery the battery door will not close the AC Quick Connect wire harness will not attach to the alarm and the alarm will not attach to the mounting plate After changing the battery reconnect the alarm and test by using the Test Reset Hush button and check that the green LED is on Replace battery with one of the following approved brands Duracell MN1604 or MX1604 Energizer 522 Ultralife U9VLJ These batteries can be purchased at your local retailer WARNING Use only the batteries specified Use of different batteries may have a detrimental effect on the Smoke CO alarm A good safety measure is to replace the battery at least once a year or at the same time you change your clocks for daylight saving time Constant exposure to high or low humidity or temperature may reduce battery lif
7. than 9 1 m 30 long If you have only one alarm ensure it is placed in the hallway outside of the main sleeping area or in the main bedroom Verify the alarm can be heard in all sleeping areas Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent the alarm from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction When mounting an alarm on the ceiling locate it at a minimum of 10 cm 4 from the side wall see Diagram A If installing the alarm on the wall use an inside wall with the top edge of the alarm at a minimum of 10 cm 4 and a maximum of 30 5 cm 12 below the ceiling see Diagram A Installation Sloped Ceilings Install Smoke Alarms on sloped peaked or cathedral ceilings at or within 0 9 m 3 of the highest point measured horizontally Smoke alarms in rooms with ceiling slopes greater than 0 3 m 2 4 m 1 to 8 horizontally should be located on the high side of the room Do not place the alarm in the peak of an A frame type ceiling see Diagram B Mobile Homes Mobile homes built within the last five to seven years are designed to be energy efficient Install Smoke CO alarms as recommended above refer to Recommended Installa
8. e 21 22 Maintenance To keep this Smoke CO Alarm in peak condition e Verify the unit s alarm and LED lights operation by pushing the Test Reset Hush button once a week e Remove the unit from mounting plate and vacuum the alarm cover and vents with a soft brush attachment at least once a year to remove dust and dirt Reinstall immediately after cleaning and then test using the Test Reset Hush button e Never use detergents or other solvents to clean the unit Avoid spraying air fresheners hair spray or other aerosols near the Smoke CO Alarm Do not paint the unit Paint will seal the vents and interfere with the sensor s ability to detect smoke and CO Never attempt to disassemble the unit or clean inside This action will void your warranty Move the Smoke CO Alarm to another location prior to performing any of the following e Staining or stripping wood floors or furniture e Painting or wall papering e Using adhesives Storing the unit in a plastic bag during any of the above projects will protect the sensors from damage WARNING Reinstall the Smoke CO Alarm as soon as possible to assure continuous protection When household cleaning supplies or similar contaminants are used the area must be well ventilated The following substances can affect the CO sensor and may cause false readings and damage to the sensor Methane propane iso butane iso propanol ethyl acetate hydrogen sulfide sulfide dioxides
9. e copied for use without the written consent of Kidde If you require further information please contact out Consumer Hotline at 1 800 880 6788 or write us at Kidde Customer Service Department 130 Esna Park Drive Markham ON L3R 1E3 Our internet address is www kidde ca
10. e mounting plate Installation e Install the alarm on the mounting plate and rotate the alarm in the direction of the ON arrow on the cover until the alarm ratchets into place this ratcheting function allows for aesthetic alignment Note The alarm will mount to the bracket in 4 positions every 90 degrees e Turn on the AC power The green AC Power On Indicator should be lit when the alarm is operating from AC power e For model KN COSM IBCA only pull the Battery Pull Tab yellow tab protruding from unit completely out of unit This will automatically connect the battery Testing CAUTION Due to the loudness 85 decibels of the alarm always stand an arms length away from the unit when testing The Test Reset Hush button has four purposes it tests the unit s electronics resets the CO alarm activates the Hush feature and activates the Peak Level Memory feature After installation test the unit s electronics by pressing the Test Reset Hush button for five seconds A series of beeps will sound followed by the message Fire Feu then another series of beeps and the message Carbon Monoxide Monoxyde de carbone followed by 4 additional short beeps The unit needs to be tested weekly If at anytime it does not perform as described verify that the power is connected correctly and that the battery is fresh Clean any dust or other buildup on the unit If it still does not operate properly call t
11. e that unborn babies pregnant women senior citizens and people with heart or respiratory problems are especially vulnerable If symptoms of carbon monoxide poisoning are experienced seek medical attention immediately CO poisoning can be determined by a carboxyhemoglobin test CO Sensor Response Times The CO sensor meets the alarm response time requirements as follows At 70 PPM the unit must alarm within 60 240 minutes At 150 PPM the unit must alarm within 10 50 minutes At 400 PPM the unit must alarm within 4 15 minutes NOTE This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion It is NOT designed to detect any other gasses Fire departments most utility companies and HVAC contractors will perform CO inspections Some may charge for this service It s advisable to inquire about any applicable fees prior to having the service performed Kidde will not pay for or reimburse the owner or user of this product for any repair or dispatch calls related to the alarm sounding Carbon Monoxide Safety Possible Sources of CO CO can be produced when burning any fossil fuel such as gasoline propane natural gas oil and wood It can be produced by any fuel burning appliance that is malfunctioning improperly installed or not ventilated correctly such as e Fu maces gas ranges stoves gas clothes dryers water heaters portable fuel burning space heaters firplaces wood burni
12. e where the air is clearer 28 e Go to a predetermined meeting place When two people have arrived one should leave to call 911 from a neighbor s home and the other should stay to perform a head count Do not re enter until fire officials say that it is safe to do so e There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72 For instance smoking in bed leaving children unsupervised cleaning with flammable liquids such as gasoline Fire Prevention Never smoke in bed or leave cooking food unattended Teach children never to play with matches or lighters Train everyone in the home to recognize the alarm pattern voice message warning and to leave the home using their escape plan when its heard Be prepared to stop drop and roll if clothes catch on fire and to crawl low under smoke Install and maintain fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Second level and higher occupied rooms with windows should have an escape ladder BEDROOM HALL MASTER ee i KITCHEN FAMILY ROOM J BASEMENT WORKSHOP FIRE EXTINGUISHER SMOKE ALARM CARBON MONOXIDE ALARM SMOKE CO ALARM Additional Recommendations Required number of smoke alarms Smoke alarms should be installed outside of each separate sleeping area in
13. ear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Know two ways out of every room door amp window and identify a meeting place outside the home where everyone will gather once they have exited the residence When two people have reached the meeting place one should leave to call 911 while the second person stays to account for additional family members Smoke Alarm Procedure Smoke alarms are designed to minimize false alarms Cigarette smoke will not normally set off the alarm unless it s blown directly into the alarm Combustion particles from spills or broiling may set off the alarm if located too close to the cooking area If the alarm sounds check for fires first If a fire is discovered follow these steps Become thoroughly familiar with these steps and review them with all family members e Alert small children in the home e Leave immediately using one of your planned escape routes see above e Before opening inside doors look for smoke seeping through the edges Feel with the back of your hand if the door is hot use your second exit If you feel it s safe open the door very slowly and be prepared to close it immediately if smoke and heat rush in If the escape route requires going through smoke crawl low under the smok
14. ecified type in good condition and installed properly e AC powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse e Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition Features e Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor e If the alarm is located outside the bedroom or on a different floor it may not wake up a sound sleeper e The use of alcohol or drugs may also impair one s ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Carbon Monoxide CO Alarm The carbon monoxide CO alarm constantly monitors the air for the presence of CO It will alarm when there are high levels of CO present and when there are low levels of CO present over a longer period of time see Page 24 for alarm times When a CO condition matches either of these situations the alarm voice message warning system will sound accompanied by the flashing red LED light The carbon monoxide sensor uses an electrochemical technology CAUTION This alarm will only indicate the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be pre
15. ed to interconnect with any other manufacturer s products Please take a few minutes to thoroughly read this user s guide and save for future reference Teach children how to respond to the alarms and that they should never play with the unit Your Kidde Smoke CO Alarm was designed to detect both smoke and carbon monoxide from any source of combustion in a residential environment It is not designed for use in a recreational vehicle RV or boat If you have any questions about the operation or installation of your alarm please call our toll free Consumer Hotline at 1 800 880 6788 The guide on Page 29 will help you determine the correct location of safety products that will help keep your home a safer place Illustrations Illustrations Test Reset Red LED Light Hush Alarm Green LED Light Sounder Permanent independent smoke and carbon monoxide sensors ionization and electrochemical Powered by 120 V AC 60 Hz 25 mA max Quick Connect wire harness Model KN COSM IBCA is also equipped with a 9 V battery backup Interconnectable to other alarms and safety accessories see Page 16 for details Loud 85 decibel alarm Voice Message System that alerts user to the following additional conditions System announces Hush mode on Mode Hush activ when the unit is first put into Hush Mode System announces Hush mode cancelled Mode Hush annul when unit resumes normal operation after Hu
16. he Consumer Hotline at 1 800 880 6788 16 Operation Interconnect Feature IMPORTANT This unit is only approved to interconnect with the Kidde line of products It is not approved to interconnect with any other manufacturer s products e When compatible smoke alarms 1235CA 1275CA 1285CA PE120CA PI2000CA and heat alarms HD135F are interconnected to this alarm they will only respond to a smoke related event e When mixing compatible models with battery backup 1275CA 1285CA PE120CA PI2000CA HD135F KN COSM IBCA with models without battery backup 1235CA KN COSM ICA be advised that the models without battery backup will not respond during an AC power failure For more information about compatible interconnect units and their functionality in an interconnect system visit our web site at www kidde ca Hush Control Feature The Hush feature has the capability of temporarily desensitizing the smoke alarm circuit for about 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm You can put the Smoke CO Alarm in Hush mode by pushing the Test Reset Hush button If the smoke is not too dense the alarm will silence immediately verbally announce Hush mode on Mode Hush activ and the green LED will flash every 2 seconds for approximately 10 minutes This indicates that the smoke alarm is in a temporarily desensitized condition The ala
17. he alarm voice message warning system will sound accompanied by the flashing red LED light NOTE The smoke alarm takes precedence when both smoke and carbon monoxide are present WARNING PLEASE READ CAREFULLY AND THOROUGHLY NFPA Standard 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate with the fire too old or young or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary e Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost however alarms have sensing limitations Ionization type alarms offer a broad range of fire sensing capabilities but are better at detecting fast flaming fires than slow smoldering fires Photoelectric alarms sense smoldering fires better than flaming fires Home fires develop in different ways and are often unpredictable Neither type of alarm photoelectric or ionization is always best and a given alarm may not always provide warning of a fire e A battery powered alarm must have a battery of the sp
18. mplied written or oral including that of merchantability or fitness for any particular purpose with respect to the battery The above warranty may not be altered except in writing signed by both parties hereto This Kidde Combination Smoke amp CO Alarm is not a substitute for property fire disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Removal of the front cover will void the warranty NOTE This alarm is not intended to alert hearing impaired individuals During the specified warranty period Kidde will repair or replace at its discretion any defective Kidde Combination Smoke amp CO Alarms that are returned in a postage paid package to the following address Kidde Customer Service Department 130 Esna Park Drive Markham ON L3R 1E3 Please include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Consumer Hotline at 1 800 880 6788 Damage from neglect abuse or failure to adhere to any of the enclosed instructions will result in termination of the warranty and the unit will not be replaced or repaired The model numbers are KN COSM IBCA with battery backup KN COSM ICA without battery backup This manual and the products described herein are copyrighted with all rights reserved Under these copyright laws no part of this manual may b
19. nd adhere to local building codes Most appliances should be installed by professionals and inspected after installation Regularly examine vents and chimneys for improper connections visible rust or stains and check for cracks in furnace heat exchangers Verify that the color of flame on pilot lights and burners is blue A yellow or orange flame is a sign that the fuel is not burning completely Teach all household members what the alarm sounds like and how to respond in an emergency Carbon Monoxide Safety Carbon Monoxide Alarm Procedure WARNING Actuation of the CO Alarm indicates the presence of Carbon Monoxide CO which can KILL YOU If alarm signal sounds 4 quick beeps 5 seconds off 1 Immediately move to fresh air outdoors or by an open door or window Check that all persons are accounted for Do not re enter the premises or move away from the open door window until emergency services responders have arrived the premises have been aired out and your alarm remains in its normal operating condition 2 Call your emergency local service fire deptartment or 911 PHONE NUMBER Never restart the source of aCO problem until it has been corrected NEVER IGNORETHE SOUND OFTHE ALARM 27 Familiarize everyone with the sound of the smoke alarm and train them to leave the home when they hear it Practice a fire drill at least every six months including fire drills at night Ensure that small children h
20. ng stoves and certain swimming pool heaters Blocked chimneys or flues back drafts and changes in air pressure corroded or disconnected vent pipes loose or cracked furnace exchangers Vehicles and other combustion engines running in an open or closed garage attached or near a home Charoal gas grills and hibachis in an enclosed area 25 26 Carbon Monoxide Safety The following conditions can result in transient CO situations Excessive spillage or reverse venting of fuel buming appliances caused by e outdoor ambient conditions such as wind direction and or velocity including high gusts of wind and insufficient draft in the vent pipes e negative pressure differential resulting from the use of exhaust fans e simultaneous operation of several fuel burning appliances competing for limited internal air e loose vent pipe connections from fuel fired appliances e obstructions or unconventional vent pipe designs that can amplify the above situations e poorly designed or maintained chimneys and or vents Extended operation of unvented fuel burning devices range oven fireplace etc Temperature inversions that can trap exhaust gasses near the ground and a Car idling in an open or closed attached garage or near a home Every year have the heating system vents chimney and flue inspected and cleaned by a qualified technician Always install appliances according to manufacturer s instructions a
21. omponents Patents Pending g Kidde 120 V AC and 9 V Battery Backup model KN COSM IBCA only Combination Smoke amp Carbon Monoxide Alarm With Voice Alarm System Hushe and Peak Level Memory Alarm Manual Model Model KN COSM ICA KN COSM IBCA f f f v H ut z pI IDE N f 8 2 f Q co lt a T gt 6 S ja Q ue Z SINGLE AND OR MULTIPLE STATION SINGLE AND OR MULTIPLE STATION SMOKE ALARM CARBON MONOXIDE ALARM SINGLE AND OR MULTIPLE STATION CARBON MONOXIDE ALARM Contents Introduction 1 Illustrations 2 3 Features ss 4 7 Installation 8 15 Operation 1 16 19 Alarm Removal 20 Battery Replacement 20 21 Maintenance 2 Carbon Monoxide Safety 23 27 Fire Safety 4 4sssuuss 28 30 Warranty ccc 31 32 Introduction Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm Model KN COSM IBCA with battery backup Model KN COSM ICA without battery backup This unit is suitable as a Single Station and or Multiple Station alarm interconnects with up to 24 devices and has a five year limited warranty IMPORTANT This unit is only approved to interconnect with the Kidde line of products It is not approv
22. rm will automatically reset after approximately 10 minutes When the unit returns to normal operation after being in Hush mode it will verbally announce Hush mode cancelled Mode Hush annul and sound the alarm if smoke is still present Operation The Hush feature can be used repeatedly until the air has been cleared of the condition causing the alarm While the unit is in Hush mode pushing the Test Reset Hush button on the alarm will also end the Hush period NOTE Dense smoke will override the Hush control feature and sound a continuous alarm CAUTION Before using the alarm Hush feature identify the source of the smoke and be certain a safe condition exists Reset Feature If the the Smoke CO Alarm is sounding a CO alarm pressing the Test Reset Hush button will silence the alarm If the CO condition that caused the alert continues the alarm will reactivate Reactivation times depend on the amount of CO present see Page 24 Peak Level Memory If the CO sensor has detected a CO level of 100 PPM or higher since last reset it will be recorded by the Peak Level Memory function To access the Peak Level Memory press the Test Reset Hush button If a reading of 100 PPM or higher has been recorded the unit will announce Caution Attention If you ve been away from home this feature allows you to check if there was a CO reading of 100 or higher during your absence Pushing the Test Reset Hush
23. sent in other areas This device is designed to protect individuals from the acute effects of carbon monoxide exposure It will not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Installation of the device should not be used as a substitute for proper installation use and maintenance of fuel burning appliances including appropriate ventilation and exhaust systems Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 ppm Never ignore the sound of the alarm Determining what type of alarm has sounded is easy with the Kidde Combination Smoke CO Alarm The voice message warning system will inform you of the type of hazard occurring Recommended Installation Locations WARNING This product is intended for use in ordinary indoor locations of family living units It is not designed to measure compliance with commercial or industrial standards IMPORTANT This alarm must be mounted on a ceiling or wall It was not designed for use as a tabletop device Install only as directed Kidde recommends the installation of a Smoke CO Alarm in the following locations For maximum protection we suggest an alarm be installed on each level of a multilevel home every bedroom hallways finished attics and basements Put alarms at both ends of bedroom hallway or large room if it is more
24. sh Mode has been cancelled System announces Caution Attention when the unit has detected CO concentrations of 100 ppm or higher One chirp every 30 seconds indicates that the alarm is malfunctioning If this occurs call the Consumer Hotline at 1 800 880 6788 Peak Level Memory Feature which alerts user when the unit has detected CO concentrations of 100 ppm or greater see Page 17 Alarm Memory Feature that gives visual indication when the alarm has sensed a hazardous condition Green and red LED lights that indicate normal operation and alarm status see Page 18 for details Tamper Resist Feature that deters children and others from removing the alarm see Page 19 For initial installation model KN COSM IBCA includes a pre installed 9 V battery and a battery pull tab that allows for easy connection Simply pull the tab out and the battery backup is connected Model KN COSM IBCA is equipped with a battery reminder tab that prohibits installation when a battery is not present Smoke alarm takes precedence when both smoke and carbon monoxide are present Seven 7 years after initial power up this unit will chirp every 30 seconds to indicate that it is time to replace the alarm Features Smoke Alarm The smoke alarm constantly monitors the air for products of combustion that are produced when something is burning or smoldering When smoke particles in the smoke sensor reach a specified concentration t
25. sts in the square holes in the mounting plate see Figure 3A Rotate the alarm onto the mounting plate until you hear the tamper resist tab snap into place locking the alarm Using the tamper resist feature will deter children and others from removing the alarm To remove the alarm press on the tamper resist tab and rotate the alarm off of the mounting plate see Figure 3B 19 Alarm Removal If the tamper resist feature has been activated refer to tamper resist feature description on page 19 for removal instructions Remove the alarm from the mounting plate by rotating the alarm in the direction of the OFF arrow on the cover To disconnect the AC Quick Connect wire hamess squeeze the locking arms on the sides while pulling the connector away from the bottom of the alarm see Page 14 Figure 2 Battery Replacement For model KN COSM IBCA only If any form of battery failure is detected the red LED light will flash and the unit will chirp one time followed by the warning message Low Battery Pile faible This cycle will occur once every minute and will continue for at least 7 days If the red LED light flashes along with a chirp every 30 seconds and is not followed by the voice message Low Battery Pile faible as described above the unit has malfunctioned Call our toll free Consumer Hotline at 1 800 880 6788 for instructions on how to return the unit CAUTION This unit is sealed The cover
26. that are used as single station do not connect the red wire to anything Leave the red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box e When alarms are interconnected all interconnected units must be powered from a single circuit e A maximum of 24 Kidde safety products may be interconnected in a multiple station arrangement Limit of 12 smoke alarms and or 18 alarms total smoke CO Smoke CO Combination heat etc This Smoke CO Combination alarm is counted as a smoke alarm when determining the maximum number of units on an interconnect line With 18 alarms interconnected it is still possible to interconnect up to a total of 6 remote signaling Installation devices and or relay modules see Page 16 for details on interconnecting Kidde devices e The maximum wire run distance between the first and last unit in an interconnected system is 305 m 1000 e Figure 1 illustrates interconnection wiring Improper connection will result in damage to the alarm failure to operate or a shock hazard e Make certain alarms are wired to a continuous non switched power line NOTE Use standard CSA listed household wire 18 gauge or larger as required by local codes available at all electrical supply stores and most hardware stores Installation Mounting CAUTION This unit is sealed The cover is not removable e Seven 7 years after initial power
27. the immediate vicinity of the bedrooms and on each additional story of the family living unit home including basements Some jurisdictions require that in new construction a smoke alarm be installed in each sleeping room Check with local officials for specific regulations concerning your situation The required number of smoke alarms protected areas mentioned above might not be reliable enough to provide early warning for unprotected areas that are separated by a door For this reason it is recommended that the householder consider the use of additional smoke alarms for those unprotected areas for increased protection Additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required number of smoke alarms The installation of smoke alarms in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in improper operation 5 Year Limited Warranty Kidde warrants that the enclosed alarm but not the battery will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase The obligation of Kidde under this warranty is limited to repairing or replacing the alarm or any part w hich we find to be defective in material workmanship or design free of charge upon sending the alarm with proof of
28. tion Instructions and Diagram A In mobile homes that are not well insulated extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may cause a thermal barrier which can prevent smoke from reaching an alarm mounted on the ceiling In such mobile homes install the Smoke CO Alarm on an inside wall with the top edge of the alarm at a minimum of 10 cm 4 and a maximum of 30 5 cm 12 below the ceiling see Diagram A If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall only 10 Installation Locations To Avoid WARNING Do not install in garages kitchens furnace rooms or bathrooms Install at least 1 5 m 5 away from any fuel burning appliance Do not install within 0 9 m 3 of the following The door to a kitchen or a bathroom that contains a tub or shower forced air ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Avoid excessively dusty dirty or greasy areas Dust grease or household chemicals can contaminate the alarm s sensors causing it to not operate properly Place the alarm where drapes or other objects will not block the sensor Smoke and CO must be able to reach the sensors to accurately detect these conditions Do not install in peaks of vaulted ceilings A
29. up this unit will chirp every 30 seconds to indicate that it is time to replace the alarm After seven years the device may no longer detect carbon monoxide accurately and should be replaced immediately To help identify the date to replace the unit a label has been affixed to the side of the alarm Write the Replace by date 7 years from power up in pemmnent marker on the label Remove the mounting plate from the back of the alarm by holding the mounting plate and twisting the alarm in the direction indicated by the OFF arrow on the alarm cover e After selecting the proper Smoke CO alarm location as described on Pages 8 10 and wiring the AC Quick Connect wire harness as described in Wiring attach the mounting plate to the electrical box To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting plate must be parallel with the hallway when ceiling mounted or horizontal when wall mounted e Pull the AC Quick Connect wire harness through the center hole in the mounting bracket and secure the bracket making sure that the mounting screws are positioned in the small ends of the keyholes before tightening CH ATTACHING THE AC QUICK CONNECT WIRE HARNESS e Plug the AC Quick Connect wire hamess into the back of the alarm see Figure 2 making sure that the locks on the connector snap into place Push the excess wire back into the electrical box through the hole in the center of th