Kidde i9010 User's Manual
Contents
1. 9m of the fol lowing the door to a kitchen the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cool ing ceiling or whole house ventilating fans or other high air flow areas Kitchens Normal cooking may cause nuisance alarms If a kitchen alarm is desired it should have an alarm silence feature or be a photoelectric type Near fluorescent lights Electronic noise may cause nuisance alarms Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpose 3 INSTALLATION INSTRUCTIONS CAUTION THIS UNIT IS SEALED INCLUDING THE BATTERY THE COVER IS NOT REMOVABLE 1 To insure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting bracket should be parallel with the hallway when ceiling mounting or horizontal when wall mounting Alignment Marks A Line on Mounting Bracket When wall mounting the A line should be horizontal When mounting in a hallway the A line should be parallel with the hallway Remove Install 2 After selecting the proper smoke alarm location as described in Section 1 attach the mounting bracket to the ceiling as shown in figure 3 For wall mounting see figure 4 Place the mounting plate on the wall be sure the A line is horizontal parallel to the floor Use the scr
2. ALARM AND IN NO CASE SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY COR PORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULT ING FROM THE FAILURE OF THE SMOKE ALARM OR FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY S NEGLIGENCE OR FAULT Since some states do not allow limitations on the duration of an implied warranty or do not allow the exclusion or limitation of incidental or conse quential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state The above warranty may not be altered except in writing signed by both parties hereto QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at www kidde com F Kidde Kidde 1016 Corporate Park Drive Mebane NC 27302
3. for 1 sec onds every 8 seconds for 7 to 9 minutes This indicates that the alarm is in a temporarily desensitized condition The smoke alarm will automatically reset after approximately 8 minutes and sound the alarm if particles of combustion are still present The SMART HUSH feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the test reset button on the alarm will end the temporarily desensitized period NOTE DENSE SMOKE WILL OVERRIDE THE SMART HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM CAUTION BEFORE USING THE ALARM SMART HUSH FEA TURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CER TAIN A SAFE CONDITION EXISTS FLASHING LED LIGHT This smoke alarm is equipped with a flash ing red indicator light with four modes of operation e The LED will flash every 40 45 seconds in the standby mode sig nifying that the alarm is receiving power e The LED will flash every 1 5 seconds when the alarm is sound ing e The LED will illuminate for 1 seconds every 8 seconds while the alarm is in the temporarily desensitized mode e If alarm memory has been set see below for alarm memory description the LED will flash rapidly when the test button is pressed ALARM MEMORY This smoke alarm has an memory function that will inform you if the alarm has sounded since the test button was last pressed The alarm memory will cause the red LED to flash rapidly when the test but
4. not be effective to protect against fire as stated in the NFPA Standard 72 For instance a smoking in bed b leaving children home alone c cleaning with flammable liquids such as gasoline 9 NRC INFORMATION lonization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products The radioactive element is safely contained in the chamber and requires no adjustments or maintenance This smoke alarm meets or exceeds all government standards It is manufactured and dis tributed under license from the U S Nuclear Regulatory Commission 10 NFPA REQUIRED PROTECTION The National Fire Protection Association s Standard 72 provides the following information Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multi ple station smoke alarms shall be installed as follows 1 In all sleeping rooms Exception Smoke alarms shall not be required in sleeping rooms in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit includ ing basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are More Smoke Alarms Desirable The required number of smoke alarms might not provide re
5. For model i9010 Smoke Alarm User s Guide Lithium non replaceable sealed in Battery Operated Smoke Alarm with Alarm Memory and SMART HUSH Control to temporarily silence nuisance alarms Thank you for purchasing this smoke alarm It is an important part of your family s home safety plan You can trust this prod uct to provide the highest quality safety protection We know you expect nothing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of alarm Date Code located on back of alarm The National Fire Protection Association NFPA and the manufacturer recommend replacing this alarm ten years from the date code Date of Purchase Where Purchased SIGNALING Manual P N 21008311 EN Rev A 0910 7225 00 LISTED This alarm detects products of combustion using the ionization technique It contains 0 9 microcurie of Americium 241 a radioac tive material see Section 9 Distributed under U S NRC License No 32 23858 01E Manufactured in compliance with U S NRC safety criteria in 10 CFR 32 27 The purchaser is exempt from any regulatory requirements Do not try to repair the smoke alarm your self Refer to the instructions in Section 12 for service IMPORTANT READ ALL INSTRUCTIONS BEFORE INSTA
6. LARM HAS BEEN DEACTIVATED IT CANNOT BE REACTIVATED WARNING ONCE THE ALARM HAS BEEN DEACTIVATED IT CANNOT BE MOUNTED ONTO THE MOUNTING BRACKET Break out the crosshatched area with a screwdriver or similar tool Using a screwdriver or similar tool slide the exposed piece towards the center of the alarm This will deactivate the alarm stop the low battery chirp and render the alarm safe for disposal by draining the battery CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR If the tamper resist feature has been activated you will need to fol low the instructions in Section 3 to remove your alarm for mainte nance To clean your alarm remove it from the mounting bracket as out lined in the beginning of this section You can clean the interior of your alarm sensing chamber by using compressed air or a vac uum cleaner hose and blowing or vacuuming through the open ings around the perimeter of the alarm The outside of the alarm can be wiped with a damp cloth After cleaning reinstall your alarm and test your alarm by using the test button If cleaning does not restore the alarm to normal operation the alarm should be replaced 7 LIMITATIONS OF SMOKE ALARMS WARNING PLEASE READ CAREFULLY AND THOROUGHLY e NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those oc
7. LLA TION AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE CONTENTS OF THIS MANUAL 1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 LOCATIONS TO AVOID 3 INSTALLATION INSTRUCTIONS 4 OPERATION AND TESTING 5 NUISANCE ALARMS 6 MAINTENANCE 7 LIMITATIONS OF SMOKE ALARMS 8 GOOD SAFETY HABITS 9 NRC INFORMATION 10 NFPA PROTECTION STANDARD 72 11 CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION 12 SERVICE AND WARRANTY 1 RECOMMENDED LOCATIONS FOR ALARMS Locate the first alarm in the immediate area of the bedrooms Try o monitor the exit path as the bedrooms are usually farthest rom the exit If more than one sleeping area exists locate addi ional alarms in each sleeping area Locate additional alarms to monitor any stairway as stairways act ike chimneys for smoke and heat Locate at least one alarm on every floor level Locate an alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room rom waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in he center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction For
8. appliances shall have an alarm silence feature or be of the photoelectric type 12 SERVICE AND WARRANTY If after reviewing this manual you feel that your smoke alarm is defective in any way do not tamper with the unit Return it for servicing to KIDDE Safety 1016 Corporate Park Dr Mebane NC 27302 1 800 880 6788 See Warranty for in warranty returns TEN YEAR LIMITED WARRANTY KIDDE Safety warrants to the original purchaser that the enclosed smoke alarm will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of pur chase The obligation of KIDDE Safety under this warranty is limited to repairing or replacing the smoke alarm or any part which we find to be defective in material workmanship or design free of charge to the cus tomer upon sending the smoke alarm with proof of date of purchase postage and return postage prepaid to Warranty Service Department KIDDE Safety 1016 Corporate Park Dr Mebane NC 27302 This warranty shall not apply to the smoke alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to oper ate due to improper maintenance or inadequate AC or DC electrical power THE LIABILITY OF KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE
9. cupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate with the fire too old or young or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of pos sible fires at a reasonable cost however alarms have sensing limitations lonization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photo electric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms Home fires develop in different ways and are 8 often unpredictable For maximum protection Kidde recom mends that both lonization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the batter ies and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach he alarm Therefore s
10. es 1 and 2 In older mobile homes that are not well insulated compared to present standards extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4 10 cm and a maximum of 12 30 5 cm below the ceiling see figure 1 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alarm close to the bedrooms For additional protec tion see SINGLE FLOOR PLAN in figure 2 WARNING TEST YOUR SMOKE ALARM OPERATION AFTER MOBILE HOME HAS BEEN IN STORAGE OR UNOCCUPIED AND AT LEAST ONCE A WEEK DURING USE 2 LOCATIONS TO AVOID In the garage Products of combustion are present when you start your automobile Less than 4 10cm from the peak of an A frame type ceiling In an area where the temperature may fall below 40 F or rise above 100 F such as garages and unfinished attics In dusty areas Dust particles may cause nuisance alarm or fail ure to alarm In very humid areas Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 3 ft
11. ews and anchors provided to secure the mounting bracket use 3 16 drill bit for anchors 3 This alarm has a battery permanently sealed inside the alarm no battery installation is necessary ACTIVATING THE ALARM This model is equipped with a feature that automatically activates the alarm when the alarm is mounted to the mounting bracket for the first time Once activated the battery will supply power to the alarm for the life of the alarm 10 years Be sure that the mounting bracket is mounted correctly before installing the alarm on the mount ing bracket To activate the alarm install the alarm on the mounting bracket figure 6 and rotate the alarm clockwise as indicated on the alarm cover until the alarm ratchets into place the ratcheting function allows for aesthetic alignment NOTE The alarm will mount to the bracket in four 4 positions every 90 degrees The alarm is now activated N After installation activation test your alarm by depressing and holding down the test button for a minimum of 5 seconds or until the alarm sounds This should sound the alarm CAU TION Due to the loudness 85 decibels of the alarm always stand an arms length away from the unit when testing TAMPER RESIST FEATURE Smoke Alarm Tamper Resist Feature This alarm is equipped with a tamper resist feature that helps pre vent someone from removing the unit from the mounting bracket When activated it can be very effective i
12. for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in Section 2 may have caused the alarm 6 MAINTENANCE BATTERY ACTIVATION AND DEACTIVATION NOTE One Lithium lon battery permanently sealed inside the alarm powers this unit no battery installation or replacement is necessary for the life of the alarm WARNING DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON To activate the alarm attach the alarm to the mounting bracket by rotating in the direction of the arrows on the cover see ACTIVAT ING ALARM in Section 3 INSTALLATION INSTRUCTIONS This alarm has a low battery monitor circuit which will cause the alarm to chirp approximately every 40 45 seconds for a mini mum of thirty 30 days at the end of the life of the alarm to indi cate that the alarm needs replacement To deactivate the alarm remove the alarm from the mounting bracket by rotating the alarm in the direction indicated by the arrows on the cover of the alarm and locate the crosshatched area on product label NOTE If the tamper resist feature has been activated see TAMPER RESIST FEATURE in Section 3 INSTALLATION INSTRUCTIONS WARNING DO NOT DEACTIVATE THE ALARM UNTIL THE END OF THE ALARM LIFE WHEN A CHIRP IS HEARD EVERY 40 45 SECONDS ONCE THE ALARM IS DEACTIVATED THE BATTERY WILL BE DEPLETED AND THE ALARM WILL NO LONGER FUNCTION WARNING ONCE THE A
13. liable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The addi tional areas include the basement bedrooms dining room fur nace room utility room and hallways not protected by the required smoke alarms The installation of the smoke alarms in the kitchen attic finished or unfinished or garage is normally not recommended as these locations occasionally experience condi tions that can result in improper operation This equipment should be installed in accordance with the National Fire Protection Association s Standard 72 NFPA Batterymarch Park Quincy MA 02269 NOTIFY YOUR LOCAL FIRE DEPARTMENT AND INSURANCE COM PANY OF YOUR SMOKE ALARM INSTALLATION 11 CAUTION AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms basements and attached garages The NFPA suggests that alarms installed within 20 6 1m of cook ing
14. mobile home installation select locations carefully to avoid hermal barriers that may form at the ceiling For more details see OBILE HOME INSTALLATION below When mounting an alarm on the ceiling locate it at a minimum of 4 10 cm from the side wall see figure 1 When mounting the alarm on the wall use an inside wall with the top edge of the alarm at a minimum of 4 10 cm and a maximum of 12 30 5 cm below the ceiling see figure 1 Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet 9 1 m long kaoi gt CEILING aww a ye 4 ANYWHERE 102 mm IN THIS BEST NEVER HERE HERE ACCEPTABLE gt HERE FIGURE 1 ANYWHERE MULTIPLE ra SINGLE FLOOR PLAN FLOOR PLAN IN THIS AREA F dee an o Pome Ely e FIGURE 2 FIGURE 3 Install Smoke Alarms on sloped peaked or cathedral ceilings at or within 3ft 0 9m of the highest point measured horizontally NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4 m horizontally shall be located on the high side of the room NFPA 72 states A row of detectors shall be spaced and located within 3 ft 0 9m of the peak of the ceiling measured horizontally see figure 3 MOBILE HOME INSTALLATION Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above see figur
15. moke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor If the alarm is located outside the bedroom or on a different loor it may not wake up a sound sleeper The use of alcohol or drugs may also impair one s ability to hear he smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Although smoke alarms can help save lives by providing an early warning of a fire they are not a substitute for an insurance poli cy Home owners and renters should have adequate insurance o protect their lives and property GOOD SAFETY HABITS DEVELOP AND PRACTICE A PLAN OF ESCAPE Install and maintain Fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Make a floor plan indicating all doors and windows and at least two 2 escape routes from each room Second story windows may need a rope or chain ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your home where you all can meet if a fire occurs Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it Practice a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and
16. n preventing smoke alarm removal or tampering Activate the smoke alarm tamper resist feature by breaking off the four posts in the square holes in the mounting bracket see figure 7 When the posts are broken off the tamper resist on the base is allowed to engage the mounting bracket Rotate the alarm onto the mounting bracket until you hear the tamper resist tab snap into place locking the alarm on the mounting bracket Using the tamper resist feature will help deter children and others from removing the alarm from the bracket NOTE To remove the alarm when the tamper resist tab is engaged press down on the tamper resist tab and rotate the alarm in the direction indicated by the arrows on the cover of the alarm see figure 8 Location of Posts 4 OPERATION AND TESTING OPERATION The smoke alarm is operating once the alarm is acti vated see Section 3 and testing is complete When products of combustion are sensed the unit sounds a loud 85db pulsating alarm until the air is cleared SMART HUSH CONTROL The SMART HUSH feature has the capability of temporarily desensitizing the alarm circuit for approxi mately 8 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is desensitized by pushing the HUSH button on the smoke alarm cover If the smoke is not too dense the alarm will silence immediately and the red LED will illuminate
17. ton is pressed The alarm memory is reset when the test button is released TESTING Test by pushing the test button on the cover and holding it down for a minimum of 5 seconds or until the alarm sounds This will sound the alarm if the electronic circuitry horn and bat tery are working If no alarm sounds the unit has defective bat tery or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire NOTE WEEKLY TESTING IS REQUIRED TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION Erratic or low sound coming from your alarm may indicate a defective alarm and it should be returned for service see Section 11 5 NUISANCE ALARMS Smoke alarms are designed to minimize nuisance alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if the alarm is located close to the cooking area Large quantities of combustible particles are gener ated from spills or when broiling Using the fan on a range hood which vents to the outside non recirculating type will also help remove these combustible products from the kitchen This model i9010 has a SMART HUSH control that is extremely useful in a kitchen area or other areas prone to nuisance alarms For more information refer to Section 4 OPERATION AND TESTING If the alarm does sound check
18. wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your chil dren It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or to those who may be incapable of safely evacuating the area unassisted WHAT TO DO WHEN THE ALARM SOUNDS Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in Stay close to the floor if the air is smoky Breathe shallowly through a cloth wet if possible Once outside go to your selected meeting place and make sure everyone is there Call the fire department from your neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do so There are situations where a smoke alarm may