Home

Kambrook KMH100 User's Manual

image

Contents

1. Keep combustible materials such as drapes and other furnishings at least 2 0 metres from the front and 0 5m from the sides and rear when it is intended for floor use and 1 0m from the top of the heater To prevent a possible fire or heat damage allow ample space around the heater at least 2 0m at front 1 0m at the top and 0 5m at the rear and sides when it is intended for floor use at least 2 0m at the front 1 0m at the top and 0 5m at the sides when it is wall mounted and do not totally or partially block the air inlet or outlets in any manner Check the openings from time to time for accumulated dust Important Safeguards For All Electrical Appliances Carefully read all instructions before operating the appliance and save for future reference Remove and safely discard all packaging material and promotional labels before using the appliance for the first time Fully unwind the power cord before use Do not let the power cord hang over the edge of a bench or table touch hot surfaces or become knotted To protect against electric shock do not immerse the power cord power plug or appliance in water or any other liquid unless it is recommended in the cleaning instructions The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appl
2. cord or plug or if the heater has been dropped future reference or damaged in any manner Return the heater to your nearest Kambrook Service Centre promotional stickers before using the Heater for examination electrical or mechanical for the first time adjustment or repair Connect only to a 230V or 240V e Do not use outdoors This heater is not power point intended for commercial use such as Avoid touching the heater body while it is on ann e Avoi uchi while it i j l i ds some i the heater pe When e Do not locate the heater immediately below moving the unit switch off and hold the heater si NADIE SR by the handles where provided e Do not use this heater with an external programmer timer or any other device that switches the heater on automatically Since e Remove any packaging material and WARNING In order to a fire risk may exist if the heater is covered or avoid overheating e 6 positioned incorrectly not cover the heater e This heater is not intended for use in wet or moist locations Do not immerse or allow liquids to be spilt on the heater e Extreme caution and supervision is necessary e Do not use this heater in the immediate when this heater is used by or near children or surroundings of a bath a shower or a invalids swimming pool e Extreme caution and supervision is necessary e his heater has hot and arcing or sparking when this heater is used near animals parts inside Do not use in areas where petro
3. KAMBROOK THE SMARTER CHOICE THERMO GUARD HEAT ADVANTAGE AAAAAA PORK RK RARAAAAAAAAAAAAAAAAADADAAAALLS PY XXX ARR AAAAAAAAAAAAAAA KAMBROOK PABADADBARA ROO OOOO Heater KMH100 KMH100 IB A11 FA indd 1 Important Please retain your instruction book for future use In the event that you need some assistance with your Kambrook appliance please contact our Customer Service Department on 1300 139 798 Australia or 0800 273 845 New Zealand Alternatively visit us on our website af www kambrook com au or www kambrook co nz KMH100 IB A11 FA indd 2 14 09 11 1 58 PM Contents Kambrook Recommends Safety First Your Kambrook Micathermic Heater Quick Start Guide Using Your Micathermic Heater Care Cleaning and Storage KMH100_IB_A11_FA indd 3 p4 p D D8 pl3 14 09 11 1 58 PM Kambrook Recommends Safety First IMPORTANT Please retain your instruction book for future use At Kambrook we believe that safe performance is the first priority in any consumer product so that you our valued customer can confidently use and trust our products We ask that any electrical appliance that you use be operated in a sensible fashion with due care and attention placed on the following important operating instructions Important Safeguards For Your Kambrook Micathermic Heater e Carefully read all instructions before e Do not operate any heater with a damaged operating the Heater and save for
4. ater as there are no customer serviceable parts inside When not in use store the heater preferably in its original box in a cool clean and dry location 13 KMH100 IB A11 FA indd 13 14 09 11 1 58 PM Notes 14 KMH100_IB_A11_FA indd 14 14 09 11 1 58 PM Notes 15 KMH100_IB_A11_FA indd 15 14 09 11 1 58 PM Kambrook Australia Kambrook New Zealand Building 2 Port Air Industrial Estate Private Bag 94411 1A Hale Street Botany Manukau Botany NSW 2019 Auckland 2163 Australia New Zealand Customer Service Line 1300 139 798 Customer Service Line Customer Service Fax 1800 621 337 Spare Parts 0800 273 845 Customer Service Fax 0800 288 513 www kambrook co nz www kambrook com au KAM B ROO K Due to continual improvement in design or otherwise the product you AAA purchase may differ slightly from the illustration in this book Issue ATI THE SMARTER CHOICE KMH100 IB A11 FA indd 1 14 09 11 1 58 PM
5. e confident circuit overload it is that the screw locations are recommended that no other correct drill suitable size holes appliances are plugged into the same circuit as your heater when it is in use 5 Take care with inserting the screws into the holes you have made and then mount the heater onto the wall bracket 10 KMH100 IB A11 FA indd 10 14 09 11 1 58 PM Setting The Heating Mode To activate the heater turn the heat setting dial clockwise to the LOW or HI setting The heater will start operating on the selected heat setting and the red power indicator light will illuminate Use the heat setting dial to select the desired heat setting LOW Low heat setting 1000 watts HI High heat setting 1500 watts Turn the heat setting dial to the OFF position to stop the heater operating NOTE This heater features a tip over switch If the heater tips over it will automatically switch off Once placed back into the upright position the heater will resume operation NOTE You may notice a faint smell and light crackle sound when using the mica heater for the first time This is normal and nothing to worry about Continue running the mica heater the smell will dissipates KMH100_IB_A11_FA indd 11 Setting The Variable Thermostat The variable THERMOSTAT can be used to maintain your desired temperature Turn the variable THERMOSTAT dial to the MAX setting Once a comfortable room temperatu
6. iance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance It is recommended to inspect the appliance regularly Do not use the appliance if the power supply cord plug connector or appliance becomes damaged in anyway Return the entire appliance to the nearest authorised Kambrook Service Centre for examination and or repair Any maintenance other than cleaning should be performed at an authorised Kambrook Service Centre KMH100 IB A11 FA indd 5 This appliance is for household use only Do not use this appliance for other than its intended use Do not use in moving vehicles or boats Do nof use outdoors Misuse may cause injury The installation of a residual current device safety switch is recommended to provide additional safety protection when using electrical appliances It is advisable that a safety switch with a rated residual operating current not exceeding 30mA be installed in the electrical circuit supplying the appliance See your electrician for professional advice Always turn the appliance to the OFF position switch off at the power outlet and unplug at the power outlet when the appliance is not in use Before cleaning always turn the appliance to the OFF position switch off at the power outlet unplug at the power outlet and remove the power cord if detachable from the appliance and allow all parts to cool Do not place this applia
7. l paints aerosols or other inflammable substances are used or stored e Do not operate the heater with the power cord damaged frayed or split wound around any part of the heater or in contact with heated surfaces of the heater e Do not mount on ceiling e Do not leave the heater unattended Always switch off the heater at the controls and at the power outlet then unplug from the power outlet when not in use e Do not use heater to dry your laundry e Do not operate heater whilst asleep KMH100 IB A11 FA indd 4 14 09 11 1 58 PM Do not allow materials that have been in contact with oil petroleum based products or drying fluids to come in contact with the heater Do not run the cord under carpeting or cover the cord with rugs runners or the like Arrange the cord away from traffic areas and where it will not be tripped over To disconnect the heater switch control to off turn off at the power outlet then remove the plug from the outlet Do not insert or allow foreign objects to pass through the inlet or outlet openings This may cause an electric shock fire or damage the heater Do not touch hot surfaces Switch off at the control switch and power outlet then unplug and allow the heater to cool down before cleaning or storing Use this heater only as described in this instruction manual Any other use not recommended by the manufacturer may cause fire electric shock or injury and voids all warranties
8. nce on or near a heat source such as hot plate oven or heaters Position the appliance at a minimum distance of 20cm away from walls curtains and other heat or steam sensitive materials and provide adequate space above and on all sides for air circulation 14 09 11 1 58 PM Your Kambrook Micathermic Heater 1 1500 watts of power for fast and 5 Wheels for easy movement even heat 6 Carry handle 2 setting dial for OFF LOW NOT SHOWN 3 Variable THERMOSTAT e Wall mountable bracket control to maintain your e Safety tip over switch desired temperature e ThermoGuard safety protection 4 Micathermic element for peace of mind produces both radiant and convection heat THERMO Wy GUARD PROTECTED KMH100_IB_A11_FA indd 6 14 09 11 1 58 PM Quick Start Guide Turning the heater on after assembly Setting the variable temperature Setting the heating mode THERMOSTAT OFF Low OFF Low iif Turn the heot Plug the cord into Turn the heot Turn the variable setting dial to the a 230V or 240V setting dial in a THERMOSTAT dial in off position Make power point and Clockwise position an anti clockwise sure that the switch switch on to the LOW or HI position to the on the THERMOSTAT heat setting MAX setting dial is set to MIN Turning the heater off THERMOSTAT Return the heat comfortable room setting dial to the temperature has OFF position to turn been reached off the heater t
9. ng the weight of this heater Mee DEI and that the right screws are used for your Wall This unit can be mounted on any wall in most rooms of the home except in the immediate surroundings of a bath a shower or a swimming pool When selecting a location decide upon a position that takes advantage of the maximum volume of air flow KMH100_IB_A11_FA indd 9 14 09 11 1 58 PM Using Your Micathermic Heater continued 2 Asa general safety guide select 6 Once the heater is mounted a suitable location to wall mount on the wall lodge the heater the heater approximately 0 5m to the mounting bracket to from any furniture furnishing either prevent the heater from being side of the unit and 2m from any accidently dislodged from the furniture furnishing placed in front mounting bracket of the heater The heater must be 7 Visually inspect the front panel mounted horizontally as per Fig 8 to ensure no foreign material is blocking this area CAUTION Do not mount the heater below curtains and or other flammable items Turning Your Heater On Turn the heat setting dial to the OFF position Make sure that the switch on 3 When selecting a location make the THERMOSTAT dial is set to MIN sure the base of the heater is at Plug the cord into a 230V or 240V least 0 5m from the floor and at power point and switch on least 1 0m from the ceiling 4 Measure out and mark the screw NOTE To avoid an electrical locations Once you ar
10. re has been reached slowly turn the variable THERMOSTAT dial anti clockwise until a click sound is heard At this setting your heater will automatically cycle on and off to maintain the desired room temperature THERMOSTAT To adjust the set temperature turn the variable THERMOSTAT dial clockwise to increase the desired temperature and anti clockwise to decrease the desired temperature 11 14 09 11 1 58 PM Using Your Micathermic Heater continues ThermoGuard Overheating Safety Device THERMO Wy GUARD PROTECTED Your heater is fitted with a safety device that switches off the heater in the event of overheating Should this heater stop working turn off the heater and inspect the air inlet and outlet for blockages Wait at least five minutes for the protection system to reset before attempting to restart the heater If the heater fails to operate or the safety device switches off again return the heater to your nearest Kambrook service centre for examination or repair 12 KMH100 IB A11 FA indd 12 14 09 11 1 58 PM Care Cleaning and Storage Ensure that the heater is switched off and disconnected from the power point before cleaning Use a clean dry cloth to clean the external surfaces of the heater If the heater has collected dust or dirt inside the unit have the unit cleaned by a qualified service agent Do nof operate the heater in this condition Do not attempt to open up any parts of the he
11. s four wheels and two 3 Turn the heater upside down wheel brackets that come with a Place the plastic wheel brackets set of screws Ihe wheel screws are onto the two perforations located located in the wheel pack at the base of the heater Ensure the bracket with the centre hole near the centre screw is placed on the right hand side of the heater l Insert the screw into The wheel ensuring the flat end of the screw sits between the wheels KMH100 IB A11 FA indd 8 14 09 11 1 58 PM 4 Line up the bracket screw with the screw hole in the base of the CAUTION Before heater and secure mounting the heater to the wall please ensure that both attachment points are secure in either timber or concrete Do NOT secure directly into plaster Please contact a tradesman if you are unsure Please see Fig 7 which illustrates the points of contact Ensure that the heater is at least 0 5 metres from the floor and corners of the wall NOTE Ensure the feet are removed from the unit before wall mounting the heater NOTE The heater comes with two sets of screws and wall mounting brackets which can be found in the bracket pack 5 Turn the heater upright so that the wheels are holding up the and on the back of the heater heating unit 1 Locate the brackets at the back Wall Mounting Instructions of the heater The bracket is located at the top of the heater Please ensure your wall is capable of holdi
12. urn the variable THERMOSTAT in an anti clockwise direction until a click sound is heard then stop Hints Tips to Retain Heat in e Fit window coverings like curtains to limit winter heat loss Your Home e Put draft stoppers such as a rolled e Don t overheat your home The up towel at the bottom of outside temperature of a heated room in winter doorways to keep out cold air should be 18 21 C Keep the heat in and the e Your heater will work more efficiently if cold out by installing wall and ceiling you stick to Kambrook s recommended insulation clearance spaces Avoid placing items too close to the e Choose the right size heater for the room heater at the front and back if it is for type you want to heat floor use for optimal air flow e Zone off unoccupied rooms by closing doors and only heat the main living areas KMH100 IB A11 FA indd 7 14 09 11 1 58 PM Using Your Micathermic Heater gt Line up the screw in the wheels with those in the base of the brackets and secure Before First Use Remove any promotional material or packaging from the heater When unpacking the heater check to see you have received the wheels and wall mounting packs before discarding the packaging Unwind the cord to its full length and place the heater on a firm level surface in a stable upright position Visually inspect the air inlet and outlets to ensure there are no blockages Securing The Heater Wheels The heater ha