Home
Kambrook CARBON KCF200 User's Manual
Contents
1. right size heater for the for optimal air flow room type you want to heat Zone off unoccupied rooms by closing doors and only heat the main living areas KCF200 IB V4 indd 7 21 10 09 9 34 AM Using Your Carbon Tower Heater Remove any promotional material or packaging from the heater Unwind the cord to its full length and place the heater on a firm level surface in a stable upright position Visually inspect the air inlet and outlets to ensure there are no blockages Assembling Your Heater Remove all items from the packaging the carbon tower body front and rear bases Unscrew the two screws from the base of the tower body To join the front and rear bases together initially feed the cord between the two parts of the base Position the front base over the corresponding posts of the rear base and press down to fit the bases together Ensure the cord remains within the channel formed when the two halves come together Turn the carbon tower body upside down Align and position the base over the corresponding posts on the rear of the tower body Push down the base onto the tower body until it is firmly held into position KCF200 IB V4 indd 8 Use the screws provided to secure the tower body to the base Clip the cord into the straight slot running from the centre to the edge of the base Ensure the cord is tidily fitted into the channel and flush with the base Turn the Carbon Tower Heater back t
2. KAMBROOK THE SMARTER CHOICE KCF200 KCF200 IB V4 indd 1 Important Please retain your instruction book for future use In the event that you need some assistance with your Kambrook appliance please contact our Customer Service Department on 1300 139 798 Australia or 09 271 3980 New Zealand Alternatively visit us on our website at www kambrook com du KCF200 IB V4 indd 2 21 10 09 9 34 AM Contents Kambrook Recommends Safety First Your Carbon Tower Heater Quick Start Guide Using Your Carbon Tower Heater Care and Cleaning Warranty Details KCF200 IB V4 indd 3 p4 p 07 p8 oll p12 21 10 09 9 34 AM Kambrook Recommends Safety First IMPORTANT Please retain your instruction book for future use At Kambrook we believe that safe performance is the first priority in any consumer product so that you our valued customer can confidently use and trust our products We ask that any electrical appliance that you use be operated in a sensible fashion with due care and attention placed on the following important operating instructions Important Safeguards For Your Kambrook Carbon Tower Heater Avoid touching heater body while it is on some parts of the heater are hot When moving the unit switch off and hold the heater by the handles where provided Keep combustible materials such as drapes and other furnishings at least 1 7 metres from the front sides and rear of the heater Do not use he
3. al to activate the timer settings The timer can be set for up to 3 hours For setting times less than 1 hour turn the timer dial past the 2 hours mark then turn back to the desired time The unit will then switch itself off after the selected time has passed By turning the TIMER dial to ON this will ensure the heater runs continuously and will not turn itself off Setting the Oscillation The oscillation function works in all operating modes Press the SWING button once to activate The heater will begin to oscillate from side to side Press the SWING button again to stop the heater from oscillating 21 10 09 9 34 AM Using Your Carbon Tower Heater cie ThermoGuard Overheating Safety Device THERMO GUARD PROTECTED Your heater is fitted with a safety device that switches off the heater in the event of overheating Should this heater stop working turn off the heater and inspect the air inlet and outlet for blockages Wait at least five minutes for the protection system to reset before attempting to restart the heater If the heater fails to operate or the safety device switches off again return the heater to your nearest Kambrook service centre for examination or repair 10 KCF200_IB_V4 indd 10 21 10 09 9 34 AM Care and Cleaning Ensure that the heater is switched off and disconnected from the power point before cleaning Use a clean dry cloth to clean the external surfaces of the heater If
4. ater to dry your laundry WARNING In order to fo A0 0 fo Jie To Liao mele not cover the heater Extreme caution and supervision is necessary when this heater is used by or near children invalids or animals This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Important this heater is intended for floor use only Do not mount on ceiling or walls Do not leave heater unattended Always switch off the heater at the controls and KCF200 IB V4 indd 4 at the power outlet then unplug heater from the power outlet when not in use Do not operate heater whilst asleep Do not operate any heater with a damaged cord or plug or if heater has been dropped or damaged in any manner Return heater to your nearest service centre for examination electrical or mechanical adjustment or repair Do not use outdoors This heater is not intended for commercial use such as construction sites Do not locate the heater immediately below a socket outlet when in use Do not use this heater with a programmer timer or any other device that switches the heater on automatically Since a fire risk may exi
5. erial Number Please don t return purchase record Purchased From until you are making a claim Register your warranty at www kambrook com au service asp Kambrook Australia Kambrook New Zealand Building 2 Port Air Industrial Estate Private Bag 94411 1A Hale Street P e ets Botany NSW 2019 us aes puree Customer Service Line Spare Parts Customer Service Line 1300 139 798 0800 273 845 or 09 271 3980 Customer Service Fax 1800 621 337 Customer Service Fax 0800 288 513 KAM B RO O Due to continual improvement in design or otherwise the product you purchase may differ slightly from the illustration in this book Issue 1 10 THE SMARTER CHOICE KCF200_IB_V4 indd 1 21 10 09 9 33 AM
6. heating elements for throughout the room gentle heating and minimal moisture loss Convenient carry handle 5 Safety tip over cut out switch 9 Power on indicator light gt THERMO GUARD PROTECTED KCF200_IB_V4 indd 6 21 10 09 9 34 AM Quick Start Guide Turning the heater on after assembly of Setting the heating mode MODE OFF LOW E KAMBROOK Set the MODE dial to the OFF Plug the cord into a 230V or Turn the MODE dial to the high Turn the TIMER dial to the ON position and 240V power or low setting position TIMER dial to 0 point and MINS switch on Setting the Turning the oscillation heater off MODE OFF _LOW ES Press the SWING Turn the heater button to off by turning activate Press the MODE dial again to stop to the OFF the oscillation position Hints Tips to Retain Heat in Fit window coverings like curtains to Y H limit winter heat loss our Home Put draft stoppers such as a rolled Don t overheat your home The up towel at the bottom of outside temperature of a heated room in doorways to keep out cold air winter should be 18 21 C Keep the heat in and the cold out by Your heater will work more installing wall and ceiling insulation efficiently if you stick to Kambrook s Avoid placing items too close to the recommended clearance spaces heater both at the front and back Choose fhe
7. o an upright position It is now ready to use Turning Your Heater On Always place the heater on a firm level surface in a stable upright position Ensure the MODE dial is turned to the OFF position and the TIMER dial is turned to the O MINS position Plug the cord into a 230V or 240V power point and switch on NOTE To avoid an electrical circuit overload it is recommended that no other appliances are plugged into the same circuit as your heater when it is in use The Power On Indicator on the front of the heater will illuminate when the heater is turned on 21 10 09 9 34 AM Setting the Heating Mode KAMBROOK To control the heater turn the MODE dial as follows The Heat Setting dial has 3 modes OFF Shuts off the heater Low heat setting 500W 2 High heat setting 1000W Once the heat setting has been selected turn the TIMER dial to the ON position This will activate the heater NOTE The Carbon Tower Heater will not activate while the Timer dial is set at 0 MINS To switch the heater off turn the MODE dial to the OFF position NOTE This heater features a tip over switch If the heater tips over it will automatically switch off Once placed back into the upright position the heater will activate again KCF200_IB_V4 indd 9 Setting the Auto Off Timer The TIMER function works in all operating modes and switches the unit off after a preset number of hours Turn the TIMER di
8. o the conditions and guarantees implied with by unauthorised persons by that legislation If the product includes one or a number of This Kambrook Replacement Warranty is valid only accessories only the defective accessory or in the country of purchase but other statutory product will be replaced Subject to your statutory warranties may still apply rights in the event of Kambrook choosing This Warranty card and the purchase receipt for this 10 replace the appliance the Kambrook product are to be retained as proof of purchase Replacement Warranty will expire at the original and must be presented if making a claim under date i e 12 months from the original date of the Kambrook Replacement Warranty Please nore Purchase that under any applicable statutory warranty you In the event that you need some assistance are not required to produce these documents but with your Kambrook appliance please contact may be required to provide a proof of purchase our Customer Service Department on 1300 139 Kambrook warrants the purchaser against defects 798 Australia or 09 271 3980 New Zealand in workmanship and material for a period of 12 Alternatively visit us on the website at months domestic use from the date of purchase WWw kambrook com au or 3 months commercial use Kambrook 12 Month Replacement Warranty Your Purchase Record Please Complete Attach a copy of the purchase receipt here Date Of Purchase Model Number S
9. s from time to time for accumulated dust Ensure long shag carpet does not obstruct airflow under the unit Do not touch hot metal surfaces Switch off at the control switch and power outlet then unplug and allow heater to cool down before cleaning or storing The heater will not operate unless it is placed on a flat level surface as it is fitted with a tilt switch Always move the heater with the handle provided Use this heater only as described in this instruction manual Any other use not recommended by the manufacturer may cause fire electric shock or injury and voids all warranties Regularly inspect the supply cord plug control settings air inlets and outlets and main housing for any damage If found damaged in any way immediately cease use of the heater and return to Kambrook or an authorised service agent for inspection or repair NOTE This Kambrook Carbon Tower Heater is electronically controlled and will not operate until the heater is plugged into a 230V or 240V power point and switched on Important Safeguards For All Electrical Appliances Fully unwind the power cord before use Do not let the power cord hang over the edge of a bench or table touch hot surfaces or become knotted The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or in
10. st if the heater is covered or positioned incorrectly This heater is not intended for use in wet or moist locations Do not use this heater in the immediate surroundings of a bath a shower or a swimming pool Do not immerse or allow liquids to be spilt on heater This heater has hot and arcing or sparking parts inside Do not use in areas where petrol paints aerosols or other inflammable substances are used or stored Do not operate the heater with the power cord damaged frayed or split wound around any part of the heater or in contact with heated surfaces of the heater 21 10 09 9 34 AM Do not allow materials that have been in contact with oil petroleum based products or drying fluids to come in contact with the heater Do not run the cord under carpeting or cover the cord with rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over To disconnect heater turn the power to OFE then turn the control switch to off Turn off at the power outlet then remove the plug from its outlet Do not insert or allow foreign objects to pass through the element guard inlet or outlet openings This may cause an electric shock fire or damage the heater To prevent a possible fire or heat damage allow ample space around the heater 1 7m at front and 0 5m at the rear top and sides and do not totally or partially block the air inlet or outlets in any manner Check the opening
11. struction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance It is recommended to regularly inspect the appliance To avoid a hazard do not use the appliance if power cord power plug or appliance becomes damaged in any way Return the entire appliance to the nearest authorised Kambrook Service Centre for examination and or repair or contact Customer Service on 1300 139 798 KCF200 IB V4 indd 5 Any maintenance other than cleaning should be performed at an authorised Kambrook Service Centre This appliance is for household use only Do not use this appliance for anything other than its intended use Do not use in moving vehicles or boats Do not use outdoors Misuse may cause injury The installation of a residual current device safety switch is recommended to provide additional safety protection when using electrical appliances It is advisable that a safety switch with a rated residual operating current not exceeding 30mA be installed in the electrical circuit supplying the appliance See your electrician for professional advice 21 10 09 9 34 AM Your Kambrook Carbon Tower Heater T 1000 watt heating elements for Control Panel efficient heating 6 Convenient 3hr auto off timer 2 ThermoGuard protection for 7 2heatsetting modes gt peace of mind Bone 60 degree oscillation for warmth 3 Carbon
12. the heater has collected dust or dirt inside the unit or around the elements have the unit cleaned by a qualified service agent Do not operate the heater in this condition Do not attempt to open the element guard or the case of the heater at any time as there are no customer serviceable parts inside When not in use store the heater preferably in its original box in a cool Clean and dry location KCF200 IB V4 indd 11 21 10 09 9 34 AM Kambrook 12 Month Replacement Warranty In Australia this Kambrook Replacement Warranty The Kambrook Replacement Warranty does not does not affect the mandatory statutory rights apply to any defect deterioration loss injury or implied under the Trade Practices Act 1974 damage occasioned by or as a result of misuse and other similar State and Territory legislation or abuse negligent handling or if tne product has relating to the appliance It applies in addition been used other than in accordance with the to the conditions and warranties implied by that instructions The Kambrook Replacement Warranty legislation excludes breakables such as glass and ceramic In New Zealand this Kambrook Replacement items consumable items and normal wear and Warranty does not affect your mandatory statutory tear rights implied under the Consumer Guarantees This Kambrook Replacement Warranty is void if Act 1993 in relation to the appliance It applies in there is evidence of the product being tampered addition t
Download Pdf Manuals
Related Search
Related Contents
User Manual Fellowes HRL 125 User's Manual MJ-810E - Lampe de plongée Bedienungsanleitung/Garantie KM 3573 Installation & Service Manual LCD-Kit01A VGA Input LCD Kit DSP-100 operator`s manual クラフト粘着テープ(再生紙タイプ) CPH6200-S1 CPH6200-S2 Manual del Usuario Copyright © All rights reserved.
Failed to retrieve file