Home

JVC DT-V20L3GZ User's Manual

image

Contents

1. SAFETY MARKER button lamp Displays hides the safety marker Adjust the area of the safety marker in MARKER of MAIN MENU page 13 This function does not work when displaying the picture in the 1 1 mode This function does not work when SAFETY MARKER or R SAFETY MARKER is set to OFF in MARKER SCREENS CHECK button lamp Displays only the selected element R G or B of the video signal Each time you press this button the picture changes in the following order NO EFFECT is displayed when you press a button which is not available for the current input or signal format the lamp lights even when the function does not The items controlled by the MAKE system cannot be controlled by the buttons on the front panel REMOTE ON is displayed and the lamps do not light RGB Normal screen Red screen Blue screen Greenscreen ASPECT button lamp Changes the aspect ratio of the picture from 4 3 to 16 9 when the picture of 16 9 aspect ratio is squeezed into 4 3 format signal To return to 4 3 press the button again This function does not work when displaying the picture in the 1 1 mode SCOPE button lamp Displays hides the indication of the wave form monitor and vector scope SCOPE SETT
2. Dy e ce 2 9 o Y Ll 8 N o i 00000 ez aziioooooo o D 300 11 7 8 DT V20L3GZ Front view 477 18 7 8 gt gt 354 14 394 6 15 5 8 359 6 14 1 4 300 11 7 8 at the higher position at the lower position lt Side view gt 99 4 lt 51 9 2 1 8 1 3 1 16 NET Me ITA 3 2 B B B E E mj aj L p 51 2 1 8 243 9 5 8 lt Side view gt 99 4 52 7 2 1 8 1 3 1 16 EM D J a B E d e P e es Up os 51 2 1 8 m 243 9 5 8 Rear view 100 VESA mounting holes Size 4 M4 depth 10 mm eo oo 100 117 4 5 8 Rear view 100 1 0 VESA mounting holes Size 4 M4 depth 10 mm e 100 17 458 27 DT V24G11Z DT V20L3GZ MULTI FORMAT LCD MONITOR 2011 Victor Company of Japan Limited 0111TMH MW MT
3. Pin No IN terminal signal OUT terminal signal 1 TXD TXD 2 TXD TXD 3 RXD RXD 4 NC NC 5 NC NC This is a female terminal 6 RXD RXD 7 NC NC 8 GND GND Specifications of the RS 232C terminal Pin No Signal 1 NC 7 2 RXD 7 3 TXD S 4 NC 5 GND 6 NC This is a female terminal 7 RTS 8 Uis The 7th terminal and the 8th 9 NC terminal are connected Command outline All commands consist of the following segments Example of communication procedures Header Monitor ID Command ID Function Data Cr ODh Starting the communication connection command I00BCN1Cr On Header Monitor f Operation commands from the personal computer etc For details see Basic command list below Monitor s status 00BOKCr Reference commands from the personal computer etc a Status returns from the monitor Selecting SDI 1 input OOBINACr To start communication send the connection command from the personal computer etc PC etc Monitor s status 00 To terminate the communication send the termination command from the personal computer etc S Terminating the communication termination command I00BCNOCT pm O Monitors status OOBOKCr Basic command list No Commands j Wu CORE N 1 Cr Starts communication connection e e o A Terminates communication termin
4. GAIN Adjust the gain level for the incoming wave form data 10 10 SIZE Select the size of the wave form monitor and vector scope window NORMAL LARGE POSITION Select the position of the wave form monitor and vector scope 1 lower right 2 window lower left 3 upper left 4 upper right TRANSPARENT Activates deactivates the function to make the window translucent ON translucent OFF normal AUTO OFF Activates deactivates the function to make the wave form monitor and ON OFF vector scope window go off automatically 15 minutes after displaying it WAVE DISPLAY Select the wave form for the wave form monitor Y Pb Pr HD signals Y Cb Cr SD signals R G B RGB signals WAVE FILTER Activates deactivates the low pass filter for the incoming wave form FLAT no filter data LOWPASS WAVE OVER Adjust the over level for the incoming luminance Y and RGB NOTE LEVEL signals MARKING Activates deactivates the function to change the color of a wave form OFF ON when the signal exceeds the limit specified on LEVEL below LEVEL Adjust the lower limit for the over level 070 109 Wave form monitor does not work for DVI signals PC input Vector scope does not work for RGB signals When you set SIZE to LARGE the window is displayed in the center of the screen regardress of the POSITION setting SYNC FUNCTION Settings for the synchronization with signals Item To do Se
5. SDI 1 Changes the input to SDI 1 Invalid Valid SDI 2 Changes the input to SDI 2 Invalid Valid DVI Changes the input to DVI Invalid Valid COMP RGB Changes the input to COMPO RGB Invalid Valid VIDEO 1 Changes the input to VIDEO 1 Invalid Valid VIDEO 2 Changes the input to VIDEO 2 Invalid Valid EXT SYNC Changes the sync signal Internal sync External sync 3G B DS Selects the SDI LEVEL B data stream DS 1 DS2 DUAL LINK Turns on or off SDI DUAL LINK Off A MARKER The area marker indication Off S MARKER The safety marker indication Off FRAME C MARKER Indication of the area of the specified aspect ratio The center marker indication Off Off MARK SEL Selects the items of MARKER Non R items R items ASPECT 1 1 Displays in 1 1 mode Off On Changes the aspect ratio 4 8 16 9 STATUS L METER TIME CODE SOURCE ID WAVE FORM VECTOR C C COLOR OFF SCR CHECK MODE MUTING DIMMER Status display t On the Status Display on page 7 Audio level meter display 29 Time code display Off is SOURCE ID in INFORMATION on page 19 Wave form monitor display Vector scope display Closed caption display Color off Screens check Change a mode according to a input picture Muting on off Change the intensity
6. SUB HOUR METER Display the hours of use unit hour You can reset this item MODEL Display the model name of the monitor VERSION Display the version of the monitor HOUR METER Display the total hours of use unit hour This item is used for maintenance of the monitor You cannot reset this item Memorized for each input 2 Ancillary time code 19 Menu Configuration SET UP MENU cont For the operation procedure see page 7 rr MENU lt SET UP MENU gt FUNCTION SETTING PICTURE SUB ADJ SIZE POSI ADJ WHITE BALANCE SET REMOTE SETTING INFORMATION gt CONTROL LOCK OFF DVI INPUT SEL AUTO SDI FORMAT AUTO all reset ENTER gt SELECT 81 EXIT MENU lt all reset gt Are you sure YES then gt key NO then MENU key Operation guide Shows the buttons for each operation The menu automatically disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu 20 Setting value OFF VOL LLOCK ALL LOCK Settings for disabling the buttons on the front panel The following operations are not available when VOL LOCK is selected VOLUME adjustment knob Picture adjustment knob The ALL LOCK function disables to control the buttons on the
7. VERSION A HOUR METER lt INFORMATION gt UPPER AUTO lt reset gt A Are you sure YES then gt NO then MENU 00001H The menu automatically disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu NOTE Setting of CHARACTER SET Assign a name for each video source 1 Change the input to one that you want to assign a video source name for 2 Select CHARACTER SET 3 Press A V buttons to select the first character lt CHARACTER SET Each time you press button the character changes as follows Press V button to reverse the order r Space 0 9 A Z a z amp lt gt _ 4 Press D button to move the arrow to the next space The characters entered before moving the arrow are memorized 5 Repeat steps 3 and 4 10 characters at maximum B Press MENU button to store the name lt CHARACTER SET A ur REMOTE SETTING External Control on pages 21 to 23 Settings for the external control Item To do Setting value SERIAL TYPE Select the input terminal used for external control by RS232C RS485 serial communication PARALLEL TYPE Select the external control method for the MAKE MAKE TRIGGER SET TRIGGER terminal PIN1 As
8. buttons are appropriate Select the proper color system COLOR SYSTEM in FUNCTION SETTING of the SET UP MENU Adjust the items of WHITE BALANCE SET in the SET UP MENU Or perform reset in WHITE BALANCE SET Buttons on the monitor do not work Set CONTROL LOCK in the SET UP MENU to OFF You cannot use the buttons for the items controlled by the MAKE system Disable the external control The following are not malfunctions 20 21 22 When a still image is displayed for long time it may remain indistinctly on the screen after the picture has changed Though the remaining picture will disappear after a while there may be a case that it remains for a long period depending on the length of time the still image was displayed for This is due to the characteristics of the LCD display and is not a malfunction Red spots blue spots and green spots on the panel surface are a normal characteristic of LCD displays and not a problem The LCD display is built with very high precision technology however be aware that a few pixels may be missing or constantly lit The following symptoms are problems only when pictures or sounds are not played back normally A slight electric shock occurs when you touch the monitor The top and or rear panel of the monitor becomes hot The monitor emits a cracking noise The monitor emits a mechanical noise Maintenance Troubleshooting
9. cont Self check program This monitor has a self check function which allows it to detect malfunctions and alert you This makes troubleshooting easier Whenever a problem occurs one or some of the INPUT SELECT lamps will flash If this happens follow the steps below and contact your dealer to resolve the problem COMPO r VIDEO RGB 1 2 The illustration of the monitor is of DT V24G11Z When the screen goes blank and one or some of the INPUT SELECT lamps COMPO RGB VIDEO1 VIDEO2 on the front control panel start flashing 1 Check which lamps are flashing 2 Press 5 button to turn off on standby the monitor 3 Turn off the power switch on the rear panel 4 Disconnect the AC power cord from the AC outlet 5 Contact your dealer with the information about which lamps were flashing f you turn on the monitor soon after turning it off or after a short term power failure the INPUT SELECT lamps may flash and no image may be displayed When this happens turn off power and wait at least 10 seconds before turning on the monitor again If the INPUT SELECT lamps do not flash you can use the monitor as normal Unplug this product from the wall outlet before cleaning Screen To avoid irreparable change in appearance of the screen such as uneven color discoloration scratches be careful about the following Do not paste or stick anything using any glues or adhesive tapes Do not write anything on the
10. Non interlace 720 50p Non interlace 1080 50p 5 Non interlace Status indication of DUAL LINK 3G SDI signal information When DUAL LINK and 3G SDI signals come in the status of DUAL LINK is displayed When SDI DUAL LINK page 12 in MAIN MENU is set to OFF and a 3G SDI signal comes in the 3G SDI signal information is displayed 5 For DT V20L3GZ When No 9 10 12 or 14 signals come in thin lines will become obscured because their signal resolution is higher than the screen resolution Status indication of DUAL LINK Non preset signals may not be displayed normally even if their frequency is within the acceptable range When SDI DUAL LINK r amp page 12 in MAIN MENU is set to and an SDI signal is selected DUAL Horizontal vertical frequency computer signal on page 26 LINK is displayed When a preset signal comes in the signal format is shown on the status display For other signals the resolution is shown Status indication of 3G SDI signal information Following signal information can be displayed when a 3G SDI signal comes in 3G A 1 Level A mapping structure 1 3G A 2 Level A mapping structure 2 3G A 3 Level A mapping structure 3 3G A 4 Level A mapping structure 4 3G B DS1 Level B data stream 1 3G B DS2 Level B data stream 2 3G B DUAL Level B DUAL LINK 11 Menu Configuration MAIN MENU For the operation procedure see page 7 DT V24G11Z
11. Setting value SIZE Adjust the horizontal picture size Setting value varies depending on the signals ee gon ba iyd H POSITION Adjust the horizontal picture position ee M E Cy POSITION 000 V SIZE Adjust the vertical picture size ADJ T V SIZE 000 m WHITE BALANCE SET POSITION 000 V POSITION Adjust the vertical picture position INFORMATION pa ecce e a a sub menu Display the sub menu which enables you to adjust the items of SIZE POSI ADJ while td id gt E viewing the actual picture Mor 00 Pai nana reset Restore the default settings for all the items in SIZE POSI ADJ ENTER SELECT 8 EXIT 1 Memorized for each signal format reset gt WHITE BALANCE SET Selects the GAMMA correction value color temperature and adjusts the drive level and cutoff point of each color A Are you sure YES then gt key Operation guide NO then MENU key Shows the buttons for each SUE operation lt WHITE BALANCE SET gt Item To do Setting value P Eai TEMP 00K GAMMA Select the GAMMA correction value 2 2 equivalent to Y 2 2 R DRIVE 000 2 35 equivalent to Y 2 35 ans T 2 45 equivalent to Y 2 45 R CUT OFF 000 2 6 equivalent to Y 2 6 eu OF 900 COLOR TEMP Select the color temperature 93
12. cr Eb MENU MENU lt MAIN MENU gt lt PICTURE FUNCTION gt ice 0 3G SDI LEVEL APERTURE LEVEL 01 APERTURE LEVEL 01 SDI DUAL LINK LE ERO A COPO RGB SEL CONPO Te on PEDE AUDIO SETTING sub menu SCOPE SETTING reset SYNC FUNCTION LTI OFF AP N 1 MODE NORMAL Operation guide Shows the buttons for each operation reset gt Are you sure YES then DBI key NO then key DT V20L3GZ gt gt gt MENU MENU lt PICTURE FUNCTION gt APERTURE FREQ OFF lt MAIN MENU gt gt PICTURE FUNCTION BACK LIGHT 00 APERTURE FREQ OFF 3G SDI LEVEL B DS1 APERTURE LEVEL 01 APERTURE LEVEL 01 SDI DUAL LINK OFF cm ME Bl COMPO RGB SEL I P MODE NORMAL AUDIO SETTING g sub menu en OFF SCOPE SETTING reset SYNC FUNCTION OSED CAPTIO N ENTER SELECT g LTI OFF I P MODE NORMAL Operation guide Shows the buttons for each operation reset gt A you sure YES then Bl key NO then MENU key The menu automatically disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu 1
13. form monitor and vector scope are input at the same time the wave form monitor is displayed 6 While controlling with the MAKE system the screen is switched between normal screen opening and blue screen short circuiting While controlling with the TRIGGER system the screen changes in the same way as when pressing SCREENS CHECK button 11 on page 6 7 Must be controlled with the TRIGGER system The mode changes in the order of NORMAL CINEMA FIELD This function cannot be controlled with the MAKE system You cannot assign the same function to different pin terminals The TRIGGER system switches each function by short circuiting the pin terminal for about 1 second and opening it m Using the serial communication You can control the monitor from a personal computer etc via the RS 485 or RS 232C terminal Consult your dealer for the details of the external control specification Communication specifications terminal RS 485 RS 232C Terminal specification Communication specifications A straight LAN cable A straight cable with a D sub 9 pin connector male for the monitor female for the personal computer etc Baud Rate 4800 bps Data Bits 8 bits Parity No parity Stop Bits 1 bit Flow Control No control Communication Code ASCII Code See below Specifications of the RS 485 terminal
14. front panel But following operations are available Turning on off on standby the monitor Displaying the SET UP MENU by pressing lt button while holding V button and turning CONTROL LOCK to OFF Operating the monitor by an external control If you try other operations Control lock on appears on the screen Setting value AUTO COMPO RGB PC When AUTO is selected the format of signals come in to the DVI D HDCP terminal is automatically recognized Normally select AUTO Select COMPO RGB or PC when the picture is not displayed correctly with AUTO DVI D input of the monitor is compatible with HDCP Eau ui Setting value AUTO MS1YCbCr MS2YCbCr MS3YCbCr MS4YCbCr 52 RGB MS3 RGB 3G B DS When AUTO is selected 3G SDI HD SDI DUAL LINK signals are automatically recognized Normally select AUTO f the picture is unstable with AUTO select the setting value according to the input signal format M is displayed on the status display when a setting other than AUTO is selected Restores all the settings and adjustments of the monitor to the default HOUR METER and the settings done by using the adjustment knobs on the front panel will not be reset After performing all reset the monitor is turned off then turned on automatically External Control About the external control This monit
15. on page 6 Daily Operations Connections cont Rear panel with LEVEL METER 2 Security slot Attach a security wire to this slot The illustration of the monitor is of DT V24G1 1Z POWER switch Turns AC power on or off You need to press 5 button r 17 on page 6 to use the monitor after turning on the POWER switch AC IN terminal AC power input connector Connect the provided AC power cord to an AC outlet Attach the provided power cord holder to prevent accidental disconnection of the AC power cord Attaching the power cord holder on page 9 CAUTION Do not connect the power cord until all other connections are completed REMOTE terminal Terminal for controlling the monitor by an external control v External Control on page 21 VIDEO INPUT 1 INPUT 2 terminals BNC Input IN and output OUT terminals for the composite signals COMPO RGB G Y R Pr R Y terminals BNC Input IN and output OUT terminals for the analog component color difference or analog RGB signals Select the signal type in COMPO RGB SEL corresponding to the type of the input signal page 12 EXT SYNC CS terminals BNC Input IN and output OUT terminals for the external composite sync Cs signals To use th
16. recommended by the manufacturer as they may be hazardous When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or equivalents Unauthorized substitutions may result in fire electric shock or other hazards Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition Under the following conditions 1 Turn off the power 2 Unplug this product from the wall outlet 3 Refer service to qualified service personnel a When the product emits smoke or unusual smell b When the product exhibits a distinct change in performance for example no picture or no Sound C If liquid has been spilled or objects have fallen on the product d If the product has been exposed to rain or water e If the product has been dropped or damaged in any way f When the power supply cord or plug is damaged Do not install this product in the following places in a damp or dusty room where the product is exposed to soot or steam such as near the cooking counter or a humidifier near heat sources where condensation easily occurs such as near the window Do not place this product on an unstable cart stand or table The product may fall causing serious injury to a child or adult and serious damage to the product The product should
17. screen Do not strike the screen with a hard object Avoid condensation on the screen Do not wipe the screen with solvent such as alcohol thinner or benzine Do not wipe the screen forcefully Wipe stains off the screen with a soft cloth If the screen gets heavily stained wipe it with a soft cloth soaked in water diluted neutral detergent and wrung well then wipe with a soft dry cloth Cabinet To avoid the deterioration or damages of the cabinet such as its paint s peeling away be careful about the following Do not wipe the cabinet using solvent such as alcohol thinner or benzine Do not expose the cabinet to any volatile substance such as insecticides Do not allow any rubber or plastic in contact for a long time Do not wipe the cabinet forcefully Wipe stains off the cabinet with a soft cloth If the cabinet gets heavily stained wipe it with a soft cloth soaked in water diluted neutral detergent and wrung well then wipe with a soft dry cloth Ventilation openings Use a vacuum cleaner to get rid of the dust around the intakes all the openings If a vacuum cleaner is not available use a cloth and wipe it off Leaving the dust around the intakes may prevent proper temperature control and cause damage to the product 20 Specifications 26 m General m LCD panel Model name DT V24G11Z Type Multi format LCD monitor Screen size Type 24 wide format Type 20 wide format Aspect ratio 16 10 Horizontal
18. setting of the monitor s ID is 00 When connecting several monitors 00 is a command for controlling all monitors at once Enter the appropriate data to xx 3 Displays the information shown when the INPUT SELECT button currently lit is pressed On the Status Display page 7 23 Troubleshooting Solutions to common problems related to the monitor are described here If none of the solutions presented here solve the problem unplug the monitor and consult an authorized dealer or service center Symptom No power supply No picture with the power on No sound Probable cause and corrective action Press the b button Firmly insert the AC power plug Turn on the POWER switch on the rear panel Select the correct input using the INPUT SELECT buttons Connect the signal cable firmly Turn on the power of the connected component and set the output correctly Check whether the input signal format is acceptable on the monitor Adjust the volume level Deactivate the muting function Connect the signal cable firmly Turn on the power of the connected component and set the output correctly Page 10 11 ooo Symptom Probable cause and corrective action 24 Page The picture becomes blurred Adjust the picture contrast or brightness by using the adjustment knobs on the front panel Or adjust CONTRAST or BRIGHT of PICTURE SUB ADJ in t
19. the apparatus has been damaged in way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus 16 Batteries shall not be exposed to excessive heat such as sunshine fire or the like 17 When discarding batteries environmental problems must be considered and the local rules or laws governing the disposal of these batteries must be followed strictly SOCIO OPPIDI The LCD panel and backlight have life expectancy Due to the basic characteristics of the LCD panel an afterimage or uneven display may occur It is recommended that you change images occasionally activate the power saving function or often turn off the power to reduce the load on the LCD panel Charges will apply for repairs resulting from deterioration due to the passage of time Installation CAUTION Do not rest your arm on the monitor or lean against the monitor Do not touch the LCD panel when installing the monitor Be sure to install the monitor securely to prevent the monitor from falling over which may cause damage to the monitor or injury You can place the monitor in the following two ways when using it on the supplied stand You ca
20. the hook not provided to the VESA mounting holes on the rear panel use the two holes on the upper side using M4 x 10 mm screws not provided Bind the hooks on the rear panel of the monitor to a wall or a pillar using durable string VESA mounting holes Hook and screw M4 x 10 mm not provided Hook not provided The illustration of the monitor is of DT V24G11Z N w Daily Operations Connections m Front panel Tally lamp This lamp is controlled by the tally function of the MAKE TRIGGER terminal You can select the color of the tally lamp from GREEN or RED rs TALLY SELECT in FUNCTION SETTING on page 17 and External Control on page 21 l ve a _ The illustration of the monitor is of DT V24G11Z Speakers stereo The speakers emit the same audio signal emitted from the AUDIO ASSIGN MONITOR OUT terminals 8 AUDIO ASSIGN MONITOR OUT terminals on page 9 VOLUME adjustment knob Adjusts the volume Picture adjustment knob PHASE Adjusts the picture hue CHROMA Adjusts the picture color density BRIGHT Adjusts the picture brightness CONTRAST Adjusts the picture contrast PHASE and CHROMA cannot be adjusted for certain signal formats When COMPONENT PHASE is set to DISABLE and an NTSC signal is input PHASE can be adjusted page 17 MUTING bu
21. vertical frequency 31 469 kHz 75 000 kHz computer signal V 48 Hz 65 Hz Some signals within this frequency range may not be displayed Out of range is displayed Compliant video signal format Available signals on page 10 Format 3G 501 SMPTE424M SMPTE425M DUAL LINK HD SDI SMPTE372M E Input output terminals HD SDI BTA S 004C SMPTE292M DT V24G11Z DT V20L3GZ SD SDI ITU R BT 656 525 625 SMPTE259M 525 VIDEO INPUT 1 Input output of composite signal EMBEDDED AUDIO 2 line BNC connector x 4 SMPTE299M SMPTE272M 1 V p p 75 Q CLOSED CAPTION VIDEO INPUT 2 The input IN and output OUT terminals are bridge connected auto termination EIA CEA 608 EIA CEA 708 DVI D HDCP DVI D signal input compatible with HDCP DT V24G11Z DT V20L3GZ Type 24 wide active matrix TFT 20 wide active matrix TFT Effective screen size Width 518 4 mm 20 1 2 Width 433 4 mm 17 1 87 Height 324 mm 12 7 8 Height 270 9 10 3 4 Number of pixels displayed 1 920 x 1 200 1 680 x 1 050 Number of colors displayed 16 77 million Viewing angle TYP 178 Horizontally 178 Vertically 178 Horizontally 178 Vertically Brightness 400 cd m 470 cd m Contrast ratio TYP 1000 1 700 1 Audio output Internal speaker 1 0 W 1 0 W Operating conditions Operating temperature 5 C 35 C 41 F
22. 00K 6500K USER a cub menu R DRIVE Adjust the drive level of each color red green and blue MIN 000 MAX in 256 grades G DRIVE B DRIVE 2 R CUT OFF Adjust the cutoff point of each color red green and blue MIN 000 MAX in 256 grades G CUT OFF B CUT OFF B CUT OFF sub menu Display the sub menu which enables you to adjust the items in WHITE BALANCE SET while viewing the actual picture reset Restore the default settings for the drive levels and cutoff points of the selected color reset gt temperature Q Are you sure YES then 2 key Memorized for each color temperature NO then key The menu automatically disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu MENU lt SET UP MENU gt FUNCTION SETTING PICTURE SUB ADJ SIZE POSI ADJ WHITE BALANCE SET gt REMOTE SETTING INFORMATION CONTROL LOCK 0 DVI INPUT SEL SDI FORMAT AUTO n all reset ENTER gt SELECT EXIT gt SERIAL TYPE PARALLEL TYPE Operation guide lt REMOTE SETTING gt ee Shows the buttons for each operation POSITION SOURCE ID gt CHARACTER SET STATUS DISPLAY TIME CODE CRC ERROR SUB HOUR METER MODEL DT V24G11Z
23. 2 PICTURE FUNCTION Setting for the picture quality Item To do Setting value APERTURE Activates deactivates the function at the level set in OFF ON For DT V24G11Z APERTURE LEVEL APERTURE FREQ Select the frequency of the luminance signal compensated in OFF LOW HIGH For DT V20L3GZ APERTURE LEVEL APERTURE Compensate the frequency response of the luminance signal of 01 10 LEVEL the video signal CTI Adjust the clearness of the outlines of the chrominance signal OFF NORMAL HARD LTI Adjust the clearness of the outlines of the luminance signal OFF NORMAL HARD MODE Selects a proper mode corresponding to the input picture NORMAL CINEMA FIELD sub menu Display the sub menu which enables you to adjust the items of PICTURE FUNCTION while viewing the actual picture reset Restore the default settings for all the items in PICTURE FUNCTION 1 Memorized for each input BACK LIGHT Setting value 20 20 Adjusts the brightness of the display Adjust according to the ambient light conditions setting value 051 052 Selects the data stream from two HD SDI signals multiplexed when a 3G SDI level signal comes SDI DUAL LINK Setting value OFF ON Activates deactivates the DUAL LINK function of SDI signals DUAL LINK is displayed when the setting is set to ON No other status indications of SDI signals are dis
24. 720 25 720 24 720 25 720 24 720 23 98 720 23 98 1080 60 1080 60 1080 59 941 1080 59 941 lt _ lt _ lt lt lt ale 1035 60i 1035 60i EJENENE 1035 59 941 1035 59 941 F 1080 50i 1080 50i 1080 60p 1080 59 94p 1080 60p 1080 59 94p lt _ lt lt lt lt lt lt lt lt 1080 50 1080 50 1080 30p 1080 30p 1080 29 97p 1080 29 97p 1080 25p 1080 25p 1080 24p 1080 24p 1080 23 98p 1080 23 98p lt lt 1080 30 5 1080 30psf 1080 29 97psF 1080 29 97psf 1080 24psF 1080 24psf 1080 23 98psF 1080 23 98psf 1080 25psF 1080 25psf ejeje lt lt lt lt lt lt _ lt _ lt lt lt lt lt lt 10 V Acceptable Not acceptable Analog component analog RGB signals are compatible with G on sync signal Y on sync signals and composite sync signals CS The separate sync signal HS VS is not compatible Compatible with EMBEDDED AUDIO signals 5 The signal is recognized as 1080 60i and the status is displayed as 1080 60i 4 The signal is recognized as 1080 59 94i and the status is displayed as 1080 59 94i On the signal format The following messages appear depending on the t
25. 95 F DVI D connector x 1 compatible with DDC2B Operating humidity 20 80 non condensing COMPOJRGB GV B Ps B Y In E Y Input output of analog component signal analog RGB signal Slightly variable depending on ambient conditions for installation R Ps R Y 1 line BNC connector x 6 Power requirements AC 120 V 50 Hz 60 Hz G Y 1 V p p 75 including sync signal Rated current 145A 1 00A B Pe B Y R Pr R Y 0 7 V p p 75Q External dimensions Width Width duas du terminals are bridge excluding protruding parts 564 mm 22 1 4 564 mm 22 1 4 477 mm 18 7 8 477 mm 18 7 8 Height Height EXT SYNC CS Input output of composite sync signal 448 6 mm 17 3 4 408 mm 16 1 8 394 6 mm 15 5 8 354 mm 147 1 line BNC connector x 2 Depth Depth 0 3V pp 4V pp 243 mm 95 8 99 mm 4 243 mm 9 5 8 99 4 75 tri level sync negative polarity sync bi level and BB with the stand without the stand with the stand without the stand including no video signal The input IN and output OUT terminals are bridge Weight 11 5 kg 25 3 Ibs with the stand 10 6 kg 23 3 Ibs with the stand connected auto termination 6 kg 18 9 ith h 7 7 kg 16 9 Ib ithout the stand 2 6 kg 18 9 OSHUMPOU the S Witnout SIN E AUDIO HD SD SDI IN 1 Digital signal input compatible with EMBEDDED AUDIO DUAL LINK signals Accessories AC
26. ADJ in SET UP MENU except when an NTSC i COMPO LEVEL SMPTE i Operation guide P 4 sub menu signal comes in 3 on page 6 Shows the buttons for each reset operation 1 lt reset gt Q Are you sure PICTURE SUB ADJ Adjusts the standard level for the picture adjustment and selects the set up level for the input video signal YES then gt key Item To do Setting value NO then MENU key CONTRAST Adjust the standard level for the contrast adjusted with the 20 20 Th 7 tically di dcn i CONTRAST knob on the front panel The menu automatically disappears in abou seconds after the previous operation E EON Some items may not appear on the menu depending on the input or the input signal BRIGHT Adjust the standard level for the brightness adjusted with the 20 20 BRIGHT knob on the front panel The items controlled by the MAKE system do not appear on the menu CHROMA Adjust the standard level for the chroma adjusted with the CHROMA 20 20 knob on the front panel PHASE 2 Adjust the standard level for the phase adjusted with the PHASE 20 20 NOTE knob on the front panel NTSC SETUP Select the set up level of the input NTSC signal 00 compliant with Settings of sub menu POSI The setting values and features are as follows LOWER 1 Displays the current setting and adjustment bar at the lower part of the scr
27. ING on page 15 Each time you press this button the window changes in the following order No display Wave form monitor Vector scope T C time code button lamp Activates deactivates the display of the time data time code contained in the SDI signal On the Information Display on page 7 Select the time code type in INFORMATION of SET UP MENU page 19 INPUT SELECT buttons lamps Selects an input SDI 1 AUDIO HD SD SDI IN 1 terminal SDI2 E AUDIO HD SD SDI IN 2 terminal DUAL LINK SDI E AUDIO HD SDI IN 1 IN 2 terminal DVI DVI D HDCP terminal COMPO RGB COMPO RGB terminal VIDEO 1 VIDEO INPUT 1 terminal VIDEO 2 VIDEO INPUT 2 terminal The lamp for the selected input lights When SDI DUAL LINK is set to ON in MAIN MENU press SDI 1 or SDI 2 to select DUAL LINK page 12 Power lamp Unlit The monitor is completely off the power switch on the rear panel is turned off Lights in Green The monitor is on Lights in orange The monitor is off on standby Flashes in orange The monitor is in the P SAVE power save mode NO SYNC ACTION in SYNC FUNCTION on page 15 5 button Turns on and off on standby the monitor The power switch is equipped on the rear panel of the monitor 1 on page 8 Menu Operations Audio Channel
28. Selection On the Information Display On the Status Display Select audio channels emitted from the speakers L R and the AUDIO ASSIGN MONITOR OUT OUT1 L OUT2 R terminals when EMBEDDED AUDIO signals come in to the E AUDIO HD SD The monitor displays the information below If you press the INPUT SELECT button 15 on Make the setting to display hide each information page 6 currently lit the status of the input signal using the MENU with the exception of 5 and setting of MUTING are displayed for about 3 controlled with T C button rs 14 on page 6 seconds 7 Display the menu To display the MAIN MENU Press MENU button To display the SET UP MENU Press lt button while holding V button MAIN MENU lt MAIN MENU gt PICTURE FUNCTION BACK LIGHT 3G SDI LEVEL B DLDLIAL LINK Selected item MARKERI S SCOPE SETTING SYNC FUNCTION CLOSED CAPTION Operation guide SET UP MENU lt SET UP MENU gt FUNCTION SETTING P R B AD Selected item T C SIE Posi ADJ RENOTE SETTING FORMAT AUTO 2 all reset Operation guide 2 Press V buttons to select an item then press c button For some items adjustments will be made by pressing OC lt MARKER gt 1 2 gt AREA MARKER MARKER ASPECT SAFETY MARKER SAFETY AREA FRAME CENTER MARKER LINE BRIGHTNESS Ex When MARKER in the MAIN MENU is selected 3 Press V buttons to select an i
29. W60 Item To do Setting value bie zi MENU gt CLOSED CAPTION gt CLOSED CAPTION Activate deactivate the closed caption OFF ON BACK LIGHT 00 CLOSED CAPTION OFF DATA FORMAT Select the data format of closed caption 708 36 SDI LEVEL B 051 DECODE CH 6C1 608ANC SDI DUAL LINK OFF Sono SCOPE SETTING SDI input DATA FORMAT 608 608VBI gt SYNG FUNCTION CLOSED CAPTION DECODE CH Selects the type of closed caption ee ne ENTER e SELECT CLOSED CAPTION COFF gt DATA FORMAT 608ANC MERE DECODE CH Cc SERVICE BLOCK Selects the type of service block SERV 1 SERV 2 SERV 3 SERV 4 SERV 5 SERV 6 Operation guide Shows the buttons for each operation SDI input DATA FORMAT 708 lt CLOSED CAPTION gt CLOSED CAPTION OFF DATA FORMAT 708 SERVICE BLOCK SERV 1 CLOSED CAPTION does not work for the video input formats PAL and B W50 CLOSED CAPTION does not work for the COMPO RGB DVI input CLOSED CAPTION does not work for the SDI input formats 1035 60i 1035 59 94i 1080 60p 1080 59 94p 1080 50p and 3G SDI Level A Depending on signal format there maybe a case that the closed captions are not displayed properly When using the 1 1 mode closed captions may not be displayed properly t Memorized for each input 2 Displayed only when SD SDI signal is input The menu automatically disappears in about 30 s
30. ace of low temperature to let it cool down WARNING TO PREVENT FIRE OR SHOCK HAZARDS DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE WARNING THIS APPARATUS MUST BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE FCC NOTICE CAUTION Changes or modifications not approved by JVC could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense IMPORTANT RECYCLING INFORMATION This product has a fluorescent lamp that contains mercury Disposal of these materials may be regulated in your community due to environmental considerations For disposal or recycling information please contact your local authorities or for USA the Electronic Industries Alliance ht
31. ation No data DEW x x 2 Assigns the control ID 01 99 Cr Initializes the control ID No data x x Displays hides the ID 00 Hide 01 Display x x Cr Flashes hides the selected ID No of the monitor 00 Hide 01 Display Displays the MAIN MENU Quits the menu operation No data Moves the cursor upward A No data Moves the cursor downward V No data Makes setting adjustment gt No data Makes setting adjustment J No data Displays the SET UP MENU No data Turns on the monitor No data Turns off the monitor on standby No data Selects SDI 1 input No data Selects SDI 2 input No data Selects input No data Selects COMPO RGB input No data Selects VIDEO 1 input No data Selects VIDEO 2 input No data Displays the status No data Turns muting on off 00 Off 01 On Changes the aspect ratio 00 4 3 01 16 9 W 2 2 U D A A S P P D A A DIDI Di O9 O2 OQ U9 9 C9 UO O E UO B O w U O2 U D w o z ziz ziziziz imsisimijo oo vmio o o ogiz vc lo nm olo og x OQ is ODh The commands for starting communication connection No 1 terminating communication termination No 2 and turning on the monitor No 13 can be used while the monitor is off on standby Enter the monitor s ID for The initial
32. be mounted according to the manufacturer s instructions and should use a mount recommended by the manufacturer Do not use this product near water Be sure to install the product in the place where proper temperature and humidity are kept Operating conditions on page 26 This product becomes hot during its use Take enough care when handling the product Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltages and other hazards Refer all service to qualified service personnel Do not use the product for a long time if the sound is distorted Use only the power source specified on the unit AC power 120 V 50 Hz 60 Hz The AC power supply is controlled by turning on off the POWER switch on the rear panel If the product is installed in a place where you cannot easily turn on off the POWER switch control the AC power supply by plugging unplugging the power cord into from the AC outlet In this case install the product as close to the AC outlet as possible and leave enough space for plugging unplugging the power cord If the product is installed in a place where you cannot easily plug unplug the power cord equip an easily accessible device to the wiring of the building for turning on off the power When the product is left unattended and unused for a long period of time unplug it from the wall outlet and disconnect the cable s
33. control even when CONTROL LOCK is set to VOL LOCK or ALL LOCK r page 20 When the monitor is off on standby external control is not available But certain external controls starting terminating communication turning on the monitor are available through the serial communication page 23 MAKE TRIGGER system You can control the monitor by a personal computer or dedicated controller 2 Using the MAKE TRIGGER system on the right The controller is not commercially available Consult your dealer if you need it Serial communication PC etc RS 485 IN RS 485 RS 485 RS 485 RS 485 RS 485 or OUT IN OUT IN OUT RS 232C For the details see page 22 mUsing the MAKE TRIGGER system The MAKE TRIGGER terminal is configured as follows You can assign a function to each pin terminal in REMOTE SETTING PIN1 PIN2 PIN3 PIN4 PIN5 in PARALLEL TYPE on page 19 You cannot change the functions assigned to the pin terminals from 6th to 8th Pin No Pin name PIN1 PIN2 PIN3 PIN4 PIN5 TALLY ENABLE 2 GND This is a female terminal The 6th pin terminal controls turning on or off the tally lamp available control even when the 7th pin terminal is invalid 2 The 7th pin terminal makes the external control valid invalid Make sure to control the terminal by the MAKE system To as
34. d for each input Pr ee MENU ES MENU gt lt SCOPE SETTING gt lt OVER LEVEL gt BACK LIGHT 00 GAIN 10 gt MARKING 0 3G SDI LEVEL B DS1 SIZE NORMAL LEVEL 070 SDI DUAL LINK OFF POSITION 1 COMPO RGB SEL COMPO TRANSPARENT OFF MARKER AUTO OFF 0N AUDIO SETTING gt SCOPE SETTING WAVE DISPLAY Y WAVE FILTER FLAT SYNC FUNCTION ENTER gt SELECT B EXIT MENU WAVE OVER LEVEL Operation guide Shows the buttons for each operation lt SYNC FUNCTION gt NO SYNC ACTION OFF DELAY TIME 30sec SYNC INPUT SEL LOW LATENCY ON The menu automatically disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu NOTE Example of the vector scope Ex When the color bar is displayed Example of the wave form monitor Ex When the luminance signal is Y MARKING is set to ON and LEVEL is set to 080 I Video signal End The wave which goes over the value set on LEVEL is indicated in red The display differs depending on the input signal or the setting of WAVE DISPLAY SCOPE SETTING Settings for the wave form monitor and vector scope Item To do Setting value
35. e picture with higher resolution than the resolution of the panel in 1 1 mode SD4 3 LARGE setting is ON FUNCTION SETTING on page 17 Make the setting to display hide the status in STATUS DISPLAY of the INFORMATION rs page 19 When STATUS DISPLAY is set to AUTO or ON the status below is also displayed in the following cases When you change the input When the signal condition of the current input changes When you turn on the monitor When STATUS DISPLAY is set to ON the signal format will remain displayed 3 seconds after the status is displayed 4 4 4 RGB 10bit MUTING ON 1 Signal format For the contents displayed see Available signals and On the signal format on page 10 Signal format of DVI input or setting of COMPO RGB SEL ts COMPO RGB SEL on page 12 DVI INPUT SEL on page 20 Status indication of DUAL LINK 3G SDI signal information t NOTE on page 11 Displayed when SYNC INPUT SEL is set to EXT external synchronization t SYNC FUNCTION on page 15 Detailed information of 3G SDI signal input Displays the sampling structure pixel resolution of the signal format Displayed when the 3G SDI signal is input Setting of MUTING Displayed only when muting is activated
36. ea marker or the safety marker is displayed by using AREA MARKER or SAFETY MARKER button or external control Select either non R items or R items to activate by using external control External Control on page 21 When a picture is displayed in 4 3 aspect ratio the safety marker for the 4 3 area is displayed To display the safety marker for the area of a picture displayed in 16 9 aspect ratio hide the area marker NOTE Memorized for each input 2 Not displayed when picture is displayed in the 1 1 mode 3 Displayed only when picture is displayed in 16 9 aspect ratio 13 Menu Configuration MAIN MENU cont For the operation procedure see page 7 gt MENU lt MAIN MENU gt PICTURE FUNCTION lt AUDIO SETTING gt lt LEVEL METER SETTING gt BACK LIGHT 00 BALANCE 0 gt LEVEL METER ch 0FF 3G SDI LEVEL B DS1 AUDIO1 ASSIGN SDI 1 BAR TYPE 3COLORS SDI DUAL LINK OFF AUDIO2 ASSIGN DVI REFERENCE LEVEL 20dB COMPO RGB SEL COMPO E AUDIO GROUP 1G OVER LEVEL 10dB MARKER f gt LEVEL METER SETTING BAR BRIGHTNESS LOW gt AUDIO SETTING PEAK HOLD OFF SCOPE SETTING El SYNC FUNCTION OSED CAPTLON ENTER gt SELECT amp EXIT MENU Adjustment bar Displayed when selecting Operation guide BALANCE Shows the buttons for each operation The menu automatical
37. econds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu Menu Configuration SET UP MENU For the operation procedure see page 7 FUNCTION SETTING Settings for the sub menu display color system color of the tally lamp picture size intensity of the button lamps gt gt and the PHASE adjustment MENU Item To do Setting value sd ERE SIRI uber d il sub menu Select the contents and displaying position of sub menu i NOTE PICTURE SUB ADJ COLOR SYSTEM AIO POSI SIZE POSI ADJ Wie BALANCE SET S043 LARGE OFF COLOR Select the color system AUTO NTSC PAL NORMAL ap TE E COMPONENT PHASE ENABLE SYSTEM If the picture is unstable with AUTO select NTSC or PAL CONTROL KOCK 3 js TALLY SELECT Select the color of the tally lamp GREEN RED D AUTO lt PICTURE SUB ADJ gt 504 3 LARGE Change the picture size of 4 3 format signal NOTE ENTER SELECT B EXIT IMENU M A NTSC SET DIMMER Select the intensity of the button lamps NORMAL DARK Q CHROMA 00 COMPO LEVEL COMPONENT Deactivates the function of PHASE adjustment Picture adjustment knob ENABLE DISABLE 30 PHASE and PICTURE SUB
38. een UPPER1 Displays the current setting and adjustment bar at the upper part of the screen LOWER2 Displays the current setting at the lower part of the screen UPPER2 Displays the current setting at the upper part of the screen The adjustment bar is not displayed for some items Settings of SD4 3 LARGE The setting values and features are as follows OFF Fit the vertical picture size into the pixel numbers of the monitor display sub menu Display the sub menu which enables you to adjust the items in PICTURE SUB ADJ while ON Fit the vertical picture size into that of the monitor display viewing the actual picture reset Restore the default settings for all the items in PICTURE SUB ADJ 096 set up signal 7 5 compliant with 7 596 set up signal COMPO LEVEL Select the level of the analog component signal 480i and 576i only B75 compliant with BetacamVTR 7 596 set up signal BOO compliant with BetacamVTR 0 set up signal SMPTE compliant with M2VTR signals Memorized for each input When COMPONENT PHASE is set to DISABLE and an NTSC signal is input PHASE can be adjusted 17 Menu Configuration SET UP MENU cont 18 For the operation procedure see page 7 SIZE POSI ADJ Adjusts the size and position of the picture gt gt rr MENU MENU Item To do
39. ency BLK The area outside the specified aspect ratio of the screen is black Only the portion of the picture within the designated area is displayed BLK L The area of the specified aspect ratio of the screen is indicated by an outline and the area outside of that becomes black so that only the area inside the line is displayed MARKER 2 Settings for marker functions 1 2 Item To do Setting value AREA MARKER Activate deactivate the area marker and select the NOTE style of it MARKER ASPECT Select the aspect ratio of the area marker 4 3 14 9 13 9 2 3511 1 85 1 1 66 1 SAFETY MARKER Activate deactivate the safety marker and select w NOTE the style of it SAFETY AREA Adjust the area of the safety marker 80 100 FRAME Displays hides the frame indicating the area of the OFF ON specified aspect ratio CENTER MARKER Displays hides the marker indicating the center OFF ON position of the picture LINE BRIGHTNESS Adjust the brightness of the marker HIGH LOW 2 2 Item To do Setting value R AREA MARKER Activate deactivate the area marker and select the NOTE style of it R MARKER ASPECT Select the aspect ratio of the area marker 4 3 14 9 13 9 2 3511 1 85 1 1 66 1 R SAFETY MARKER Activate deactivate the safety marker and select NOTE the style of it R SAFETY AREA Adjust the area of the safety marker 80 100 The ar
40. ese terminals set SYNC INPUT SEL to EXT SYNC FUNCTION on page 15 The terminals are for all VIDEO INPUT 1 INPUT 2 and COMPO RGB When an external sync signal is input external synchronization has priority over all VIDEO 1 VIDEO 2 and COMPO RGB input AUDIO ASSIGN IN 1 IN 2 terminals pin jack Input terminals for the analog audio signals Use this terminal for the analog audio connection of the SDI When a superimposed signal EMBEDDED AUDIO signal on an SDI signal is input analog audio signals cannot be input Select the video input to assign the audio signal in AUDIO1 ASSIGN or AUDIO2 ASSIGN AUDIO SETTING on page 14 8 AUDIO ASSIGN MONITOR OUT terminals pin jack Output terminals for the analog audio signal The terminals output the audio signal through AUDIO ASSIGN IN 1 or IN 2 terminals when you select the Attaching the power cord holder The provided power cord holder prevents accidental disconnection of the AC power cord from the AC IN inal video input you have selected for AUDIO1 ASSIGN or AUDIO2 ASSIGN in AUDIO SETTING page Ne Sout b RR Gees E E 14 The signal is output from this terminal only when the monitor is on SAVE power save mode SYNC ACTION on page 15 1 2 3 To detach the cover The EMBEDDED AUDIO signal AC IN is decoded into an analog signal then emitted Case ter
41. he SET UP MENU 6 17 Wrong picture position wrong picture size Check whether the setting of 1 1 or ASPECT buttons is appropriate Check whether the input signal format is acceptable on the monitor Adjust the picture size H SIZE V SIZE or position H POSITION V POSITION of SIZE POSI ADJ in the SET UP MENU For some signals the picture cannot be displayed fully in the effective Screen area There is no sure method to solve this problem 10 11 18 OTHERS or Out of range appears Check whether the input signal format is acceptable on the monitor 10 11 Some items do not appear on the menu The items which are not available for the current input or the current input signal are not displayed on the menu Change the input or the input signal The items controlled by the MAKE system do not appear on the menu 21 SYNC appears Select the correct input using the INPUT SELECT buttons Connect the signal cable firmly Turn on the power of the connected component and output video signals Or check whether the video output of the component video output setting of the VCR or graphic board of the computer is set correctly Wrong color no color Adjust each picture adjustment knob on the front panel or adjust the items of PICTURE SUB in the SET UP MENU Or perform reset in PICTURE SUB ADJ Check whether the setting of COLOR OFF or SCREENS CHECK
42. level meter Item To do 14 Setting value BALANCE Adjust the balance between the right and left speakers L5 L1 0 R1 R5 AUDIO1 ASSIGN Select the video input which the audio signal through AUDIO ASSIGN IN 1 terminal is assigned to SDI 1 SDI 2 DVI COMP RGB VIDEO 1 VIDEO 2 AUDIO2 ASSIGN Select the video input which the audio signal through AUDIO ASSIGN IN 2 terminal is assigned to E AUDIO GROUP Select the audio channel group of the EMBEDDED AUDIO NOTE signals LEVEL METER Adjust the level meter display for the EMBEDDED AUDIO NOTE SETTING signals LEVEL METER ch Select how the audio channels are displayed on the level meter OFF LINE Displays the channels 1 6 at the left of the screen and 7 12 at the right DIVIDE Displays the odd channels at the left of the screen and the even channels at the right BARTYPE Select the color of the level meter display 3COLORS 3 colors to indicate variations in input levels W 100 white REFERENCE Select the standard input level indicated on the level meter 20dB 18dB LEVEL OVER LEVEL Select the input level s lower limit indicated in red for the 10dB 8dB SCOLORS display 4dB 2dB BAR Select the brightness of the level meter LOW HIGH BRIGHTNESS PEAK HOLD Activates deactivates the peak hold function of the level OFF ON meter t Memorize
43. ly disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu NOTE Settings of E AUDIO GROUP The setting values and selectable audio channels of EMBEDDED AUDIO signals are as follows G means GROUP channel s 1 2 3 4 1 2 3 4 1 4 1G channel s 5 6 7 8 5 6 7 8 5 8 2G channel s 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 4 1G 5 8 2G 1 8 1G 2G channel s 9 10 11 12 9 10 11 12 9 12 3G channel s 1 2 3 4 5 6 7 8 9 0 1 1 12 1 2 3 4 5 6 7 8 9 10 114 12 1 4 1G 5 8 2G 9 12 3G 1 8 1G 2G 1 12 1 3G Example of the level meter display Level meter position and audio channels Ex When LEVEL METER ch is set to LINE and BAR is set to SCOLORS OVER LEVEL 7 E REFERENCE LEVEL Red Yellow Green The level meter with no audio signal input is displayed in white for 83COLORS in gray for W 100 You can select the position of the level meter display top or bottom of the screen POSITION in INFORMATION on page 19 When PEAK HOLD is set to ON the maximum level meter value will remain displayed for a set period of time At the time the signal input level reaches the highest value AUDIO SETTING Settings for the audio output balance EMBEDDED AUDIO signals and
44. minal Cover is emitted only when SDI 1 or SDI 2 is selected and when EMBEDDED AUDIO signals come in to the E AUDIO HD SD SDI IN 1 or IN 2 terminal has priority over the audio signal input to AUDIO ASSIGN IN 1 or IN 2 terminals when SDI 1 or SDI 2 is selected for AUDIO1 ASSIGN or AUDIO2 ASSIGN and the EMBEDDED AUDIO signal is input to E AUDIO HD SD SDI IN 1 or IN 2 terminal 9 E AUDIO HD SD SDI IN 1 IN 2 terminals BNC Input terminals for the HD SD SDI signals CAUTION The terminals accept also EMBEDDED AUDIO signals including up to 12 audio channels with a sampling Use only the provided screws frequency of 48 kHz Make sure the plug will not be pulled out after the cover is attached to the case Use both terminals when selecting DUAL LINK SDI for the input 10 AUDIO HD SD SDI SWITCHED OUT terminal BNC Output terminal for the HD SD SDI signals The SDI signals of the current input SDI 1 or SDI 2 are re clocked then emitted When an input other than SDI 1 and SDI 2 is selected the SDI signal of the input selected last time is emitted from this terminal The signals are emitted from this terminal only when the monitor is on or in PSAVE power save mode No signals are emitted when DUAL LINK SDI is selected for the input 11 DVI D HDCP terminal Input terminal for the DVI D signal compatible with HDCP When the picture is not displa
45. n INFORMATION on page 19 2 3 4 5 CAMERA 1 TC 12 34 56 01 608 amp CRC 6 Audio level meter Not displayed when LEVEL METER ch is set to OFF x AUDIO SETTING on page 14 Signal format Displayed when STATUS DISPLAY is set to ON gt INFORMATION on page 19 For the contents displayed see Available signals and On the signal format on page 10 Source name assigned in CHARACTER SET Displayed when SOURCE ID is set to ON or AUTO Displayed in large letters when STATUS DISPLAY is set to OFF or AUTO t INFORMATION on page 19 CRC error indication Displayed when CRC ERROR is set to ON INFORMATION on page 19 Ared square is displayed when an error occurs Time code When the input signal includes no time code is displayed 14 on page 6 Data format Displayed when STATUS DISPLAY vs INFORMATION on page 19 is set to and SDI signal is input not all SDI signals CLOSED CAPTION on page 16 When any information of 1 2 3 4 or 6 above is displayed while signals come in from equipment other than a computer the picture is displayed without overlapping the information display area However the information display will overlap with the picture when displaying th
46. n tilt the monitor as follows When the stand plate is attached to the higher position of the stand body To adjust the stand height on page 5 you can place the monitor as illustrated below 1 Remove the screws on the right side of the stand 5 see the illustration below then lift the stand up by about 148 Monitor About 148 Screw silver About 6 0 LE IE 5 About 6 2 Attach the removed screws and place the monitor When the monitor is not tilted 0 the as illustrated below guidelines align as illustrated below Guidelines o 9 A The illustration of the monitor is of DT V24G11Z The illustration of the monitor is of DT V24G11Z To place the monitor as illustrated on the left again remove the screws on the right side of the stand return the monitor angle to 0 then reattach the removed screws CAUTION e When lifting up the stand lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being You can select the stand height higher position or lower position vs To adjust the stand height on page 5 CAUTION Be careful not to pinch your fingers in the gap between the monitor and the stand When the stand plate is attached to the lower position of the stand body you cannot tilt the damaged monitor downward be careful not to pinch your fingers in the moving
47. of the button lamps NORMAL No function Selects which functions in MARKER are activated non R items or R items MARKER on page 13 2 Displays the information shown when INPUT SELECT button of the current input is pressed On the Status Display on page 7 While controlling with the MAKE system the information is displayed only at the moment of short circuiting 3 While controlling with the MAKE system the level meter is switched between displayed short circuiting and hidden opening When LEVEL METER ch is set to OFF the level meter is not displayed NO EFFECT appears While controlling with the TRIGGER system the pattern of the audio channel display is switched 4 While controlling with the MAKE system the available set up options will be the setting value currently selected in SOURCE ID ON or AUTO short circuiting and OFF opening While controlling with the TRIGGER system uses the same set up option as those in the SET UP MENU SOURCE ID in INFORMATION on page 19 5 While controlling with the MAKE system the wave form monitor and vector scope is switched between displayed short circuting and hidden opening regardless of the AUTO OFF setting in the MAIN MANU While controlling with the TRIGGER system the screen is switched in the same way as when pressing the SCOPE button 13 on page 6 If the wave
48. or has three external control terminals MAKE TRIGGER terminal RJ 45 The following external control systems are available 1 MAKE make contact system Controls the monitor by short circuiting the corresponding pin terminal to the GND pin terminal or disconnecting opening it 2 TRIGGER trigger system Controls the monitor by sending the pulse signal instantaneously to the corresponding pin terminal Using the MAKE TRIGGER system on the right e RS 485 terminals RJ 45 Controls the monitor with the RS 485 system Using the serial communication on page 22 e RS 232C terminal D sub 9 pin Controls the monitor with the RS 232C system Using the serial communication on page 22 Set the following items of REMOTE SETTING in SET UP MENU according to the external control terminal and control system SERIAL TYPE PARALLEL TYPE on page 19 The settings of this unit Control terminal Control system SERIAL TYPE setting jor dg MAKE TRIGGER MAKE terminal TRIGGER TRIGGER RS 485 terminal Serial RS 485 RS485 RS 232C terminal communication RS 232C RS232C For a monitor connected a personal computer etc select the terminal the equipment is actually connected to For other monitors select RS485 Control priority is as follows MAKE gt TRIGGER serial communication buttons and menu on the monitor e You can use external
49. parts Make sure of lifting the stand up until it stops about 148 otherwise the monitor may fall over Place the monitor on a mat to avoid scratching the table surface Do not lift up the stand when the stand plate is attached to the lower position of the stand body To detach the stand CAUTION Lay the monitor on a cloth with the LCD panel facing down to prevent the LCD panel from being damaged 1 1 Attachment screws f 9 Stand body Monitor The illustration of the monitor is of DT V24G11Z To install the stand When attaching the stand to the monitor insert the guides of the stand into the guide holes on the monitor to place the stand in the correct position Then fix the stand firmly with the attachment screws Guide holes Guides Screw holes for stand attachment Stand plate Monitor Stand body The illustration of the monitor is of DT V24G11Z To adjust the stand height To change the stand height detach the stand from the monitor s To detach the stand page 4 Then change the position of the stand plate according to the stand height you want by choosing the screw holes to use Higher position Lower position Screw holes for higher position Screw holes for lower position Stand plate Stand plate To prevent an accidental fall Fix the monitor to a wall by using strings Fixing the monitor Attach
50. played Set this setting to OFF when SDI signal other than DUAL LINK SDI is input Setting value COMPO COMPONENT RGB Selects the signal type you want to use for COMPO RGB terminals ee MENU lt MAIN MENU gt PICTURE FUNCTION Psi um 51 2 pa BACK LIGHT 00 3G SDI LEVEL 051 MARKER ASPECT 4 3 SDI DUAL LINK OFF SAFETY MARKER OFF COMPO RGB SEL SAFETY AREA 180 gt MARKER FRAME OFF AUDIO SETTING CENTER MARKER OFF SCOPE SETTING LINE BRIGHTNESS HIGH SYNC FUNCTION lt MARKER gt 2 2 ENTER e SELECT E EXIT MENU gt R AREA MARKER OFF R MARKER ASPECT 4 3 R SAFETY MARKER OFF R SAFETY AREA 80 Operation guide Shows the buttons for each operation The menu automatically disappears in about 30 seconds after the previous operation Some items may not appear on the menu depending on the input or the input signal The items controlled by the MAKE system do not appear on the menu NOTE Setting of AREA MARKER SAFETY MARKER R AREA MARKER R SAFETY MARKER The setting values and features are as follows OFF Deactivate the marker LINE Displays the area with an outline HALF The area outside the specified aspect ratio of the screen is displayed at 50 transparency HALF L The area of the specified aspect ratio of the screen is indicated by an outline and the area outside of that is displayed at 50 transpar
51. power cord Power cord holder x 1 Screw x 2 for power cord holder E AUDIO HD SD SDI IN 2 auto detection 2 line BNC connector x 2 E AUDIO HD SD SDI Digital signal output compatible with EMBEDDED AUDIO signals SWITCHED OUT 1 line switched out BNC connector x 1 Notice on transportation AUDIO ASSIGN IN 1 Analog audio signal input 2 line RCA connector x 4 This monitor is precision equipment and needs dedicated packing material for transportation Never use any packing material supplied from sources other than JVC or JVC authorized dealers AUDIO ASSIGN IN 2 500 mV rms high impedance Audio AUDIO ASSIGN Analog audio signal output 1 line RCA connector x 2 MONITOR OUT 500 mV rms REMOTE MAKE TRIGGER Using the MAKE TRIGGER system on page 21 REMOTE RS 485 REMOTE RS 232C For easy understanding pictures and illustrations are shown by being emphasized omitted or composed and may be slightly different from actual products Design and specifications are subject to change without notice External control All company names and product names mentioned herein are used for identification purposes only and may be the trademarks or registered trademarks of their respective companies Using the serial communication on page 22 Specifications cont E Dimensions mm inch DT V24G11Z Front view 564 22 1 4
52. rvice Please read these IMPORTANT SAFEGUARDS carefully before use All the safety and operating instructions should be read before the product is operated The safety and operating instructions should be retained for future reference All warnings on the product and in the operating instructions should be adhered to All operating instructions should be followed POWER CONNECTION The power supply voltage rating of this product is AC 120 V The power cord attached conforms to the following power supply voltage and countries Use only the power cord designated to ensure safety and EMC regulations of each country For U S A and Canada AC 120 V sy This plug will fit only into a grounded power outlet If you are unable to insert the plug into the outlet contact your electrician to install the proper outlet Do not defeat the safety purpose of the grounded plug This product should be operated only with the type of power source indicated on the label If you are not sure of the type of power supply of your home consult your product dealer or local electric power company Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Before connecting other products such as VCR s and personal computers you should turn off the power of this product for protection against electric shock Do not use attachments not
53. serial communication 22 Troubleshooting eese 24 Self check program 25 Maintenance eere 25 Specifications 2 26 Generali ee iis eae 26 The illustration of the monitor is of DT V24G11Z LCD panel tont i 26 Input output terminals 26 In the case that you use the monitor for many hours we recommend that you set NO Dimensions ssssseeeene 27 SYNC ACTION in SYNC FUNCTION to P SAVE in MAIN MENU This will reduce power consumption and relieve strain on the monitor For Customer Use Enter below the Serial No which is located on the rear of the cabinet Retain this information for future reference Model No DT V24G11Z DT V20L3GZ Serial No LCT2588 002A H Safety Precautions WARNING REDUCE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS RAIN OR MOISTURE NO OBJECTS FILLED WITH LIQUIDS SUCH AS VASES SHALL BE PLACED ON THE APPARATUS IMPORTANT SAFEGUARDS Electrical energy can perform many useful functions This unit has been engineered and manufactured to assure your personal safety But IMPROPER USE CAN RESULT IN POTENTIAL ELECTRIC SHOCK OR FIRE In order not to defeat the safeguards incorporated into this product observe the following basic rules for its installation use and se
54. sign the control functions to the pins of the MAKE Functions controlled by the PIN2 TRIGGER terminal MAKE TRIGGER system on Assign a function to each pin terminal by selecting page 22 PIN4 SET in PARALLEL TYPE mentioned above PIN5 The functions are assigned for PIN6 PIN8 INFORMATION and you cannot change the assignment of these functions Settings for the information display of the monitor Item To do Setting value POSITION Select the position to show the information display On the UPPER LOWER Information Display on page 7 SOURCE ID Select whether the name assigned in CHARACTER SET is OFF ON AUTO displayed on the screen On the Information Display on page 7 When AUTO is selected the display color synchronizes with the color of the tally lamp while the tally lamp is lit CHARACTER Assign a name to each video source as you like 10 characters at NOTE SET maximum You can also enter a name using the RS 232C system STATUS DISPLAY Select whether the status of the current input and the setting of AUTO OFF ON MUTING are displayed on the screen rs On the Status Display on page 7 TIME CODE Select the type of the TIME CODE display VITC 2 LTC 2 D VITC CRC ERROR Select whether the CRC error indication for the input HD SDI signal is ON OFF displayed on the screen On the Information Display on page 7
55. sign the functions to the pin terminals For the operation procedure see page 7 1 Select REMOTE SETTING on the SET UP MENU 2 Set PARALLEL TYPE to SET 3 Select a pin name PIN1 PIN5 for which you want to assign a function then select the function you want to assign For the selectable functions see the table on page 22 Operation of the external control 1 Set PARALLEL TYPE of REMOTE SETTING to MAKE or TRIGGER in the SET UP MENU 2 Short circuit the 7th pin terminal ENABLE to the 8th pin terminal GND so that the monitor can be controlled by the external control 3 When the MAKE system is selected Operate each function by short circuiting the corresponding pin terminal to the 8th pin terminal GND or opening it When the TRIGGER system is selected Operate each function by pulse control that is short circuiting the corresponding pin terminal to the 8th pin terminal GND for about 1 second and opening it When changing the input with MAKE system only one pin terminal must be short circuited Other pin terminals must be opened When selecting the TRIGGER system you can operate only one function at a time Operate the functions one by one 21 External Control cont lt Functions controlled by the MAKE TRIGGER system gt Display Functions to be controlled Opening Short circuiting TALLY SEL Selects the color of the tally lamp Green Red
56. tem then press lt gt buttons to make adjustments 4 Press MENU button to finish the menu operation Pressing MENU button repeatedly deactivates the display of the menu SDI terminal IN1 or IN2 and SDI input 1 or 2 is selected You have to choose a group of selectable audio channels before the channel selection E AUDIO GROUP in AUDIO SETTING on page 14 When a DUAL LINK SDI signal is input it is assigned to SDI 1 The setting is memorized for each input SDI 1 and SDI 2 1 Press lt or gt button when a menu is not displayed The screen for audio channel selection is displayed The screen for audio channel selection automatically disappears in about 30 seconds after the previous operation Audio channel selection screen Selected item E AUDIO R ch 2 2 Press V buttons to select the left L ch or right R ch 3 Press ac buttons to select audio channel Each time you press the button the audio channel changes according to the settings of E AUDIO GROUP NOTE on page 14 4 Press MENU button The screen for audio channel selection disappears Using the audio level meter You can check the conditions of the current EMBEDDED AUDIO signals in the audio level meter On the Information Display on the right LEVEL METER SETTING in AUDIO SETTING on page 14 Select the position of the information display POSITION i
57. tp www eiae org IMPORTANT SAFETY INSTRUCTIONS Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when
58. tting value NO SYNC ACTION Select the screen status when no signal is coming in OFF P SAVE power save mode GRAY B gray screen DELAY TIME Select the period until the screen status changes as selected 30sec 5min 15min in NO SYNC ACTION after signals stop coming in SYNC INPUT Select the sync signal for the VIDEO1 VIDEO2 and INT Internal sync SEL 3 COMPO RGB input EXT External sync LOW LATENCY Activates deactivates the function to shorten the time ON OFF taken to display the picture low latency function f the picture is not displayed steadily while ON is selected select OFF While ON is selected the displayed picture may become unstable when an operation using buttons on the front panel or the menu is performed or when the signal format changes When setting NO SYNC ACTION to GRAY B the screen color changes to gray and the power consumption of the back light is saved by half Selecting P SAVE power save mode saves more power consumption by turning off the back light In the initial setting NO SYNC ACTION is set to and DELAY TIME set to 15min Change the settings if necessary 3 Memorized for each input 15 Menu Configuration MAIN MENU cont 16 For the operation procedure see page 7 CLOSED Cee Settings for CLOSED CAPTION functions MENU Video input NTSC B
59. tton Turns off the sound when no menu screen is displayed To cancel the function press the button again or turn the VOLUME adjustment knob Muting function is also canceled when BALANCE of AUDIO SETTING in the MAIN MENU is changed page 14 actually work lt gt V buttons When a menu screen is displayed Selects or adjusts menu items Menu Operations on page 7 When no menu screen is displayed Selects the audio channels of EMBEDDED AUDIO signals Audio Channel Selection on page 7 Pressing lt button while holding V button displays the SET UP MENU rs Menu Operations on page 7 MENU button Activates deactivates the display of the MAIN MENU Menu Operations on page 7 COLOR OFF button lamp Displays only the luminance signal This function does not work for RGB input signals 1 1 button lamp Displays the picture in the original resolution of the input signal The aspect ratio of the picture may change depending on the input signal AREA MARKER button lamp Displays hides the area marker Select the style of the area marker in MARKER of the MAIN MENU 1 page 13 This function works only when displaying the picture in 16 9 aspect ratio This function does not work when AREA MARKER or R AREA MARKER is set to OFF in MARKER
60. within the product s enclosure that be of sufficient magnitude to constitute a risk of electric shock to persons The lightning flash with arrowhead symbol within an equilateral triangle is CAUTION intended to alert the user to the presence RISK OF ELECTRICAL SHOCK of uninsulated dangerous voltage DO NOT OPEN CAUTION To reduce the risk of electric shock Do The exclamation point within n not remove cover or back No user equilateral triangle is intended to alert iceabl ts inside Ref icin the user to the presence of important SELVICE AIC Se vicing operating and maintenance servicing to qualified service personnel instructions in the literature accompanying the appliance DT V20L3GZ INSTRUCTIONS MULTI FORMAT LCD MONITOR Safety Precautions 2 IMPORTANT SAFEGUARDS 2 Installation 4 Daily Operations Connections 6 Front panel nitentes 6 Rear panel essen 8 Available 10 Menu Configuration MAIN MENU 12 Menu Configuration SET UP MENU 17 External Control eene 21 About the external control 21 Using the MAKE TRIGGER system 21 Using the
61. yed correctly change the setting of DVI INPUT SEL rs page 20 Note for connections Before making any connections turn off all the equipment Use a cord whose plugs correctly match the terminals on this monitor and the equipment Plugs should be firmly inserted poor connections could cause noise When unplugging a cord be sure to grasp its plug and pull it out DO NOT connect the power cord until all connections are complete Refer also to the user manual of each piece of equipment Daily Operations Connections cont Available signals The following signals are available for this monitor Video signals 2 Signal NTSC Signal format shown in the status display page 7 NTSC Input terminal VIDEO INPUT1 INPUT2 COMPO RGB Analog component Analog RGB E AUDIO SDI IN 1 IN 2 2 SD HD 1 5G 3G SDI DUAL LINK DVI D HDCP Digital component Digital RGB PAL PAL B W50 B W50 B W60 B W60 480 601 480 601 480 59 941 480 59 94i 576 50i 576 50i 480 60p 480 60p 480 59 94p 480 59 94p 576 50 640 480 60 576 50 640 480 60 640 480 59 94 640 480 59 94 720 60 720 60 720 59 94 720 59 94 720 50 720 50 _ lt _ 4 720 30 720 30 720 29 97 720 29 97
62. ype of input signals and their conditions When a DVI D signal protected with HDCP is input at the end of the indication When no video signal comes in NO SYNC When a noncompliant video signal comes in Out of range When COLOR SYSTEM FUNCTION SETTING on page 17 is set to AUTO and the noncompliant composite video signals come in OTHERS Computer signals preset Specification of the DVI D HDCP terminal DVI D HDCP terminals Connect it to the DVI D output terminal on a personal computer Resolution Frequency Pin ial Pin tel Pin e ianal S t nput signa nput signa nput signa Signal name Horizontal Vertical Vertical Hz isi i ne E _ 2 1 T M D S Data 2 9 T M D S Data 1 17 T M D S Data 0 1 VGA60 Non interlace 2 T M D S Data 2 10 T M D S Data 1 18 T M D S Data 0 2 WVGA60 Non interlace TM DS Data 2 shield 11 T M D S Data 1 shield 19 T M D S Data 0 shield 3 SVGA60 Non interlace 4 NC 12 NC 20 NC 4 XGA60 Non interlace 5 NC 13 NC 21 NC 5 WXGA 1280 Non interlace 6 DDC Clock 14 45V Power 22 T M D S Clock shield 6 WXGA 60 Non interlace 7 DDC Data 15 GND 23 T M D S Clock 7 SXGA60 Non interlace 8 INC 16 Hot Plug Detect 24 T M D S Clock 8 WSXGA 60 Non interlace UXGA60 5 Non interlace WUXGAG0 5 Non interlace NOTE 720 60p Non interlace 1080 60p 5
63. ystem Do not overload wall outlets extension cords or convenience receptacles on other equipment as this can result in a risk of fire or electric shock Use only the accessory cord designed for this product to prevent shock Slots and openings in the cabinet are provided for ventilation These ensure reliable operation of the product and protect it from overheating These openings must not be blocked or covered Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short circuit the parts which could result in a fire or electric shock Never spill liquid of any kind on the product Never place anything on the product Placing liquids naked flames cloths paper etc on the product may cause a fire Do not apply any strong shock to the LCD panel Do not hit any object against it or push it with a sharp pointed tool Do not put heavy objects on the product Do not step on or hang on the product Caution for use of the product in the high temperature Do not use the product in places of high temperature otherwise parts of this product or the LCD panel may be damaged This product is equipped with a temperature sensor to give warning if the temperature becomes too high If the temperature exceeds the range of normal use TEMP OVER is displayed and the power is turned off automatically if the temperature becomes any higher In this case move the product to a pl

Download Pdf Manuals

image

Related Search

Related Contents

Untitled - Neocontrol  Samsung WF7520N1B Инструкция по использованию  Istruzioni e avvertenze  RIDGID R150FSA User's Manual  仕様(PDFファイル)  iP 15 Series Manual  Oral History Panel on the Development and Promotion of the Intel  Oricom C1000 User's Manual  TS7500HD 1 - Tele System  Landscape Equipment Safety - Chesapeake Employers Insurance  