Home
        Jenn-Air Range JES9800CA User's Manual
         Contents
1.  or less     May be used to vent straight out the back of the range and directly through  the wall     CALCULATING MAXIMUM DUCTING LENGTH  aximum ducting length is 60   18 3 m     Each 90   elbow equals 5   1 5 m  duct    Use no more than three 90   elbows    Flexible metal vent is not recommended    Do not install two elbows together     NOTES    For ducting runs up to 30   9 1 m   install range as shipped   For ducting runs of 31   9 4 m  to 60   15 2 cm   remove the  restricter ring on the blower inlet housing    For altitudes above 4500   1272 0 m   reduce recommended  vent run by 20  for best performance           5   12 7 cm   to 6   15 2 cm   diameter i  transition elbow   j                   6   15 2 cm   diameter wall cap       THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE    M4JENN AIR    JRC120053 03 2012    
2. JENN AIR    DETAILED PLANNING DIMENSIONS                                                                                                                                                                   1 of 4  30  SLIDE IN ELECTRIC DOWNDRAFT RANGE  JES9800CA   3034  x 36  x 2874   PRODUCT DIMENSIONS  t  A   C MODEL   JES9800CA  7 in cm  oOo D E A Overall width 30  78 1      Width of door drawer    yy t B Euro Style Stainless or Oiled Bronze 30  76 5  Floating Glass 29  75 9  g G C Height of cooking surface 1   4 0 5  D Height of control panel 41  10 6  E Space between door and control panel   15  F Height to top of handle 18   4 47 5      gt  G Height of door 20  51 5  l H Height of lower panel 85 8 22 0  i l Space between door and lower panel   1 5      J Depth to corner of control panel 24   4 61 5  j p a K Depth to center of control panel 25   4 64 0  FRONT VIEW   a A  gt    yo  O    O   1  TOP VIEW    Product dimension  cutout and installation specifications are provided for planning purposes only  Before installing    any product  be sure to verify cutout dimensions and electrical gas connections as actual product dimensions may vary     M4JENN AIR    JRC120053 03 2012    JENN AIR    DETAILED PLANNING DIMENSIONS 2 of 4    30  SLIDE IN ELECTRIC DOWNDRAFT RANGE  JES9800CA   3034  x 36  x 287        DIMENSIONS AS INSTALLED                                                                         MODEL   JES9800CA  in cm  At ba of cooking 36 91 2  B  Height to top of door  mi
3. circuit is recommended  Minimum length of power cord is 36   91 4 cm      cm  7 9  21 3  16 2  8 9  3 8  22 8  5 7  31 8  47 6                                                                Side  Cabinet  m    L     cs O  O  N      m  E   L     o0   SIDE VIEW   SIDE WALL BACK VIEW    VENTING OPTION       ZJENN AIR    JRC120053 03 2012                               JENN AIR   DETAILED PLANNING DIMENSIONS A of 4  DOWNDRAFT SLIDE IN RANGE DUCTING ARRANGEMENTS  DUCTING CONFIGURATIONS DUCTING REQUIREMENTS  5   12 7 m  RANGE DUCT LENGTH DUCT SIZE  diafietef duci i 5   12 7 cm   10   3 0 m  or less  ene    diameter  Dual Fuel  6   15 2 cm   Gas Between 10   3 0 m  diameter  and 60   18 3 m  31   4  x 10    8 3 cm x 25 4 cm   i ee 5   12 7 cm   10   3 0 m  or less diameter    5   12 7 cm  diameter 6   15 2 cm   to 3   4  x 10        8 3 cm x 25 4 cm  Electric Between 10   3 0 m  diameter  transition elbow  and 60   18 3 m  31 4  x 10   REAR DUCTING IN WALL TO ROOF  8 3 cm x 25 4 cm     5   12 7 cm   diameter duct    5   12 7 cm   diameter wall cap             REAR DUCTING THROUGH WALL TO OUTSIDE    6   15 2 cm   diameter elbow    SIDE DUCTING IN TOE KICK TO OUTSIDE    Product dimension  cutout and installation specifications are provided for planning purposes only  Before installing  any product  be sure to verify cutout dimensions and electrical gas connections as actual product dimensions may vary               Dual fuel ranges must use 5   12 7 cm  diameter for runs of 10   3 0 m 
4. ght to bottom of uncovered wood or  E metal cabinet above cooking surface  min   30 70 2  ooo Ee a  G Height of electrical installation area  max   10 25 4  l H Depth of electrical installation area  max   2 5 1  1   Height to center of vent opening option 8  20 8  J Width of cutout 30 76 2  C l K   Depth of cutout 23 58 4   A   L   Depth of upper cabinet  recommended  13 33 0       M Depth to center of vent opening option 18 45 7  G   Gl N Height to center of vent opening option 31  79 2    Z   O Width to power cord 9 23 0  Ht e Recommended junction box location  FRONT VIEW     REAR WALL VENTING OPTION  gt  Recommended venting location                       TOP VIEW   CUTOUT       d h  Side Saa  Cabinet i ae  e       TOP VIEW     FLOOR VENTING OPTION    Product dimension  cutout and installation specifications are provided for planning purposes only  Before installing  any product  be sure to verify cutout dimensions and electrical gas connections as actual product dimensions may vary     A                              gt  fo    e e  a  e a      see page 4 for ducting information     Dimension can be reduced by 6   15 2 cm  when bottom of wood or metal cabinet is  covered by not less than 1 4   0 6 cm  flame retardant millboard covered with not less  than No  28 MSG sheet metal  0 015   0 4 mm  stainless steel  0 024   0 6 mm  aluminum  or 0 020   0 5 mm  copper     ELECTRICAL REQUIREMENTS  240 volt  60 Hz  AC only  40 amp fused  grounded circuit is required  A dedicated    
5. n   30  78 5  C  Height to top of handle  min   29  74 0  D  Height to top of lower panel  min   10 25 2  E  Height to top of countertop  min   35  90 8  F Depth with door fully open 45   2 115 5  G Depth with handle 28  73 2  H Depth to center of control panel 26  68 0      Depth without door 24   2 62 2  J Depth with door 26  67 0  Height of countertop channel 1  4 0  egw   a  M Depth of countertop channel 1  4 0  OPTIONAL ACCESSORIES  SIDE VIEW m ene stainless steel A134 106 0  x Height to top of 12  stainless steel A73_ 1213    backsplash  min     Add up to 134   4 4 cm  to height with leg levelers fully extended                        SIDE VIEW   COUNTERTOP CHANNEL DETAIL       M4JENN AIR  Product dimension  cutout and installation specifications are provided for planning purposes only  Before installing    any product  be sure to verify cutout dimensions and electrical gas connections as actual product dimensions may vary  JRC120053 03 2012                                                                                                                               JENN AIR   DETAILED PLANNING DIMENSIONS 3 of 4  30  SLIDE IN ELECTRIC DOWNDRAFT RANGE  JES9800CA   3034  x 36  x 2874   OPENING CLEARANCE DIMENSIONS  MODEL   JES9800CA  in cm  a een en 3076 2  B Width from cooktop to fixed wall 3 76  Fo or other combustible material  min     a A Width from electrical installation area 51 14 0  to cabinet  min    D Width to center of vent opening option  max   2  5 7  E     Hei
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Exhaust Air Brochure  VIESMANN - Viessmann  User Manual - SellMyRetro  ASUS Premium P5WD2 User's Manual  Linksys HomeLink HPPO200 User's Manual  Philips AJ7010 User's Manual  Message CenterQuick Start Guide    Hewlett Packard Enterprise ProLiant DL180 G9  Montigny notre commune-N°298-mars 2015 (pdf    Copyright © All rights reserved. 