Home
        Jasco Zwave Light Control ZWAVEKIT User's Manual
         Contents
1.     45607    Traveler   color not green     Green          grounded          traveler   Black    Red White  Hot      Hot     45610    AWARNING    SHOCK HAZARD   Turn OFF the power to the branch circuit at the circuit    breaker in your electrical service panel  Ensure power   is OFF before you install this device  All wiring connections  must be made with the POWER OFF to avoid personal  injury and or damage to the switch        1  Shut off power to the circuit at fuse box or circuit breaker    2  Remove wall plate   Warning  Verify power is OFF to switch  before continuing    3  Remove the switch mounting screws    4  Carefully remove the switch from the switch box  DO NOT  disconnect the wires   5  Identify the wiring in the box and decide if this will be the  location for the Auxiliary Switch or the Dimmer Switch    6  Mark the wiring so it can be identified properly later    7  Disconnectthe wiring and remove the switch    8  Install either the Auxiliary or Dimmer Switch as shown in the  wiring diagram   9  Insertthe new switch into the switch box being careful not to  pinch or crush wires    10  Repeat Steps 2 through 9 for the second switch    11  Reapply power to the circuit at fuse box or circuit breaker and  est the system     Observe Important Wiring Information    Always follow the recommended wire strip lengths and wiring  combinations when making wiring connections  Important   The wire connectors included with this dimmer are intended to  only be used with coppe
2.  or exclude the dimmer switch from   the Z Wave home control network       Refer to the instructions for your primary controller to access  the network setup function and include or exclude devices      When prompted by your primary controller  tap the top or  bottom of the rocker      The primary controller should indicate that the action  was successful  If the controller indicates the action was  unsuccessful  please repeat the procedure       Once the dimmer switch is part of the network  the same  basic procedure is used to add the dimmer switch to groups   amp  scenes or change advanced functions  Refer to the  primary controller s instructions for details     Please Note  After a power failure  the 45607 dimmer switch   returns to its last used On Off Dim state    LED Indicator   Primary Switch Only     The LED will be lit when the connected lighting is OFF      This is the factory default setting and can be changed if your  primary controller supports the node configuration function   see Advanced Operation below      ADVANCED OPERATION   The following Advanced Operation parameters require that you  have an advanced controller like the 45601 Advanced remote   Advanced remotes from other manufacturers may also be able  to change these settings  however  basic remotes do not have  this capability     All On All Off   Depending upon your primary controller  the 45607 dimmer  switch can be set to respond to ALL ON and ALL OFF  commands in up to four different ways  Some c
3. 45613    Wireless Lighting Control  3         Dimmer  Switch Kit       Z Wave   Certified  Wireless Lighting Control    Introduction     Thank you for your purchase of a GE Z Wave   enabled control  device  Z Wave technology is designed to automate lighting   home control and provide easy remote operation of all your  Z wave enabled devices  The GE Z Wave product family  includes a variety of devices to control lighting in your home   Control one room or your entire house  and you can do it all  now or start with one room and add more over time     The 3 way dimmer switch kit is one  components of a Z Wave   control  system and is designed to work with all  other Z Wave enabled devices in a  home control network  It includes both  the primary dimmer switch  45607    and an auxiliary switch  45610  for   the second switch location  The  primary switch also acts as a  wireless repeater to insure that  commands intended for another  device in the network are  received  thereby extending  the range of the wireless  controller  Z Wave devices  of other types and brands  can be added to the system  and will also act as range extenders  if they support this function of  repeating the signal received to  other nodes in the system                 The auxiliary switch is not Z Wave enabled and does not  directly control electrical loads  It must be used with a  compatible Z Wave enabled  3 wire switch in three way  installations where a light is controlled from 2 locations   such as th
4. Oklahoma 73114   Made in China   Hecho en China    All brand names shown are  trademarks of their respective  owners     Todas las marcas que aparecen  aqu   son marcas registradas de  sus respectivos duefios     
5. controller   network     Manual On Off Brightness control with the front panel rocker     LED indicates primary switch location in a dark room     Adjustable Dim rates    BASIC OPERATION    Remote Control   GE Z Wave remotes provide control of an Individual device   Groups of devices and Scenes  Other brands of Z Wave  Certified remotes may not offer as much flexibility in how you  can set up your lighting control network  Please refer to your  remote control s instructions for details on its capabilities and  instructions for adding and controlling devices     Manual Control   Both switches allow the user to turn ON OFF and control the  brightness level of the connected incandescent lighting      To turn the connected lighting ON  Tap the top of the rocker       To turn the connected lighting OFF  Tap the bottom of the  rocker      To brighten the connected lighting  Press and hold the top of  the rocker  release when desired level is achieved     To dim the connected lighting  Press and hold the bottom of  the rocker  release when desired level is achieved  Please  note  pressing and holding the rocker until the light intensity  is at the minimum setting does not turn the power OFF  you    must still tap  press  amp  release  the bottom of the rocker to  turn the power OFF      When OFF  pressing and holding the bottom of the rocker will  cause the lighting to go to the minimum dim level     Program your light Switch  The model 45607 primary switch   must be used to include
6. e top and bottom of a staircase  This switch  communicates with the Z Wave enabled switch  providing  manual On Off Dim control of the connected lighting  through  the Z Wave enabled switch  and synchronization of the  lighting status  On Off Dim level  between the two switches     ACAUTION                 This device is intended for installation in accordance  with the National Electric Code and local regulations  in the United States  or the Canadian Electrical Code  and local regulations in Canada  If you are unsure or  uncomfortable about performing this installation  consult a qualified electrician        This dimmer is designed for use only with permanently  installed incandescent lighting fixtures  Do not use it to  control fluorescent lighting  transformer supplied lighting   appliances  motorized appliances or receptacles  The  incandescent lighting controlled by this dimmer must not  exceed a total of 500 watts     There are no user serviceable  parts in this unit     Dimmer switch       LED light       Air gap switch    WARNING    RISK OF FIRE  RISK OF ELECTRICAL SHOCK  RISK OF BURNS    Controlling Appliances    Exercise extreme caution when using Z Wave devices to control  appliances  Operation of the Z Wave device may be in a different  room than the controlled appliance  also an unintentional activation  may occur if the wrong button on the remote is pressed  Z Wave  devices may automatically be powered on due to timed event  programming  Depending upon the appl
7. equipment into an outlet on a circuit different from  that to which the receiver is connected     Consult the dealer or an experienced radio TV technician for help   Operation is subject to the following two conditions       This device may not cause interference     This device must accept any interference  including interference  that may cause undesired operation of the device    Important Note  To comply with the FCC RF exposure compliance   requirements  no change to the antenna or the device is permitted  Any   change to the antenna or the device could result in the device exceeding   the RF exposure requirements and void user s authority to operate the   device    Compliance with IC Rules and Regulations   IC  6924A 45606A7   Jasco Products Company   Model  45607    This Class B digital device complies with Canadian ICES 003     SPECIFICATIONS   Power  120 VAC  60 Hz    Signal  Frequency   908 42 MHz    Minimum Load  40W  incandescent lamps only    Maximum Load  500W  incandescent lamps only    Range  Up to 65 feet line of sight between the Wireless Controller and  the closest Z Wave receiver module    Operating Temperature Range  32 104  F  0 40         For indoor use only     Specifications subject to change without notice due to continuing  product improvement    Z Wave is a registered US trademark of Zensys A S      is a registered trademark of  General Electric Company   and is used under license to  Jasco Products Company LLC   10 E Memorial Rd   Oklahoma  City  
8. iance  these unattended  or unintentional operations could possibly result in a hazardous  condition  For these reasons  we recommend the following     1  Assign Z Wave controlled appliances to device numbers    10   18 on the GE Z Wave remote  The likelihood of  unintentionally turning on the appliance will be reduced  significantly because the  Shift  button will need to be  pressed before pressing device numbers 10 18    Z Wave devices controlling appliances should be removed  rom  All  control setting  Instructions on how to do this  are included in the manual for your GE Z Wave remote    Do Not include Z Wave devices in Groups or Scenes if they  control appliances    Do Not use Z Wave devices to control electric heaters or  any other appliances which may present a hazardous  condition due to unattended or unintentional or automatic  power on control    Double check programs for accuracy before using them              Wireless Range   This device complies with the Z Wave standard of open    dir  line of sight transmission distances of 65 feet  Actual  performance in a home depends on the number of walls  between the remote controller and the destination device   the type of construction and the number of Z Wave enabled  devices installed in the control network     GE Z Wave network   Every Z Wave enabled device acts as a signal repeater and  multiple devices result in more possible transmission routes  which helps eliminate  RF dead spots         Things to consider regard
9. ing RF range      Each wall or obstacle  i e   refrigerator  big screen TV  etc    between the remote or a Z Wave device and the destination  device will reduce the maximum range of 100 feet by  approximately 25 3096      Brick  tile or concrete walls block more of the RF signal than  walls made of wooden studs and plasterboard  drywall       Wall mounted Z Wave devices installed in metal junction  boxes will suffer a significant loss of range  approximately  2096  since the metal box blocks a large part of the RF signal     Effects of Home Construction on Wireless Range Between  Z Wave Enabled Devices   Note  The distances shown in the table below are typical  examples  Actual performance in your home will vary   From the Remote  or repeating Z Wave module  to    destination device     Type of Construction                               Wood Frame   Brick  Tile or  w Drywall Concrete  Plastic Metal Plastic Metal  J Boxes    J Boxes   J Boxes    J Boxes  0    100    80    100    80     Number    i      of Walls or 1  70 56 60 48  Obstacles 2  49    39   36   29   3  34 27r 21 17     unction      For Plug in Modules or In Wall Devices Installed in Plastic J    Boxes       Line of Sight   no obstructions       Please Note  Z Wave home control networks are designed to work  properly alongside 802 11 wireless computer networks  Bluetooth    and other 2 4GHz or 5 8GHz devices  Some baby cams  wireless video  devices and older cordless phones using the 900MHz frequency range  may ca
10. itch position             Z Wave  Auxiliary                Z Wave  Primary                         Incorrect switch position                         Refer to the wiring diagram for wiring details    IMPORTANT NOTE ABOUT 3 WAY CIRCUITS CONT     The yellow wire from the 45607 must only be connected to   the yellow wire of the 45610 via the traveler wire  The dimmer  switch will fail if the yellow wire is connected to Line  Hot    Neutral or Ground  It must be insulated properly if it is not used     Please consult an electrician if you have trouble identifying the  type of wiring circuit you wish to convert or if you do not feel  confident in your ability to convert the circuit to Z Wave control     INSTALLATION    This dimmer switch is designed for use with permanently  installed incandescent lighting only and may be used in new  installations or to replace an existing wall switch  A wall plate  is not included  You may be able to re use your existing wall  plate if you are replacing a standard decorator style switch  or dimmer  Ifthis is a new installation or your existing wall  plate can not be used  we recommend the use of a mid sized   decorator style wall plate  These are available at most home  centers or hardware stores     It can be used by itself or in three way installations where a   light is controlled from 2 locations such as the top and bottom  of a staircase  It is also compatible with four way installations   three switches  amp  one light  if a second auxiliar
11. ontrollers may  not be able to change the response from its default setting   Please refer to your controller s instructions for information on  whether or not it supports the configuration function and if so   how to change this setting     The four possible responses are    1  It will respond to ALL ON and the ALL OFF command  default     2  Itwill not respond to ALL ON or ALL OFF commands    3  It will respond to the ALL OFF command but will not respond to   the ALL ON command    4  Itwillrespond to the ALL ON command but will not respond to  the ALL OFF command        LED Light   When shipped from the factory  the LED on the 45607 is set to  turn ON when the connected light is turned OFF  This allows the  LED to indicate the switch s location in a dark room  To make  the LED turn ON when the light is turned ON  change parameter  3 s value to  1        Parameter No  3    Length  1 Byte    Valid Values   0 or 1  default 0     Invert Switch   If the dimmer switch is accidentally installed upside down with   On  at the bottom and  Off  at the top  the default On Off  rocker settings can be reversed by changing parameter 4 s  value to  1       Parameter No  4     Length  1 Byte     Valid Values   0 or 1  default 0     Dim Rate Adjustments   Both the number of steps  or levels  that the dimmer will change  and the timing of the steps can be modified to suit personal  preferences  The timing of the steps can be adjusted in 10  millisecond intervals  As an example  the default se
12. r wire  Consult a qualified electrician    if you have aluminum wiring              Instructions    1  Strip insulation 3 8  for 12 or 14 AWG wire  Strip insulation  7 16  for 16 or 18 AWG wire    2  Hold stripped ends together in parallel and align any frayed  strands  do not twist wires      3  Push wires firmly into connector  Twist connector clockwise  with fingers until tight  Pull wires to check for tightness     Wire Connector   Combination Chart    One  14 w one to four  16 or  18  One  12 w one to three  14 or  16 or  18    Two  14 w one to three  16 or  18  Two  12 w one or two  14 or  16 or  18    You should now be able to use the rocker to manually turn  On Off Brighten the connected lighting     Use your primary controller to include the dimmer switch in  the home control network after the dimmer switch is wired as  shown in the above diagram  It can then be added to groups  and or lighting scenes and managed remotely to control   the On Off status and brightness level of the connected  incandescent lighting     Air Gap Switch   The 45607 has an air gap switch on the lower left side  see  diagram for location  to completely disconnect power to the  load  Pull the air gap switch OUT to disconnect the power and  push it all the way back in for normal operation  The air gap  switch must be all the way in for the dimmer to function and  control the lighting     Key Features     Controls one light from two locations     Remote On Off Brightness control via the Z Wave 
13. tations may  not apply to you  This warranty gives you specific rights  and you  may also have other rights which vary from state to state  Please  contact Customer Service at 800 654 8483  option 4  between  7 30AM   5 00PM CST or via our website  www jascoproducts com  if  the unit should prove defective within the warranty period or   visit easyzwave com    JASCO Products Company  Building B  10 E Memorial Rd  Oklahoma City  OK 73114       FCC   U2245606 7   The Federal Communication Commission Radio Frequency Interference  Statement includes the following paragraph    The equipment has been tested and found to comply with the limits   fora Class B Digital Device  pursuant to part 15 of the FCC Rules  These  limits are designed to provide reasonable protection against harmful  interference in a residential installation  This equipment uses  generates  and can radiate radio frequency energy and  if not installed and used in  accordance with the instruction  may cause harmful interference to radio  communication  However  there is no guarantee that interference will not  occur in a particular installation  If this equipment does cause harmful  interference to radio or television reception  which can be determined by  turning the equipment off and on  the user is encouraged to try to correct  the interference by one or more of the following measures       Reorient or relocate the receiving antenna     Increase the separation between the equipment and receiver     Connect the 
14. the command      Parameter No  5     Length  1 Byte     Valid Values   0 or 1  default 1     Restoring Factory Defaults  All Configuration Parameters can all be restored to their factory  default settings by using your master controller to reset the device     Interoperability with Z Wave    Devices   A Z Wave  network can integrate devices of various classes  and  these devices can be made by different manufacturers  Although  every Z Wave certified product is designed to work with all other  Z Wave certified products  your controller must include the  appropriate device classifications in order to control non lighting  Z wave devices  As an example  the GE 45600 basic remote is  designed only for controlling Z Wave devices using the lighting  control classification  The GE 45601 deluxe remote with LCD readout  can control other Z Wave certified devices like thermostats as well  as lighting   WARRANTY  JASCO Products warrants this product to be free from  manufacturing defects for a period of two years from the original  date of consumer purchase  This warranty is limited to the repair   or replacement of this product only and does not extend to  consequential or incidental damage to other products that may be  used with this product  This warranty is in lieu of all other warranties   expressed or implied  Some states do not allow limitations on how  long an implied warranty lasts or permit the exclusion or limitation  of incidental or consequential damage  so the above limi
15. tting for  parameter 8 is  5   This means that the lighting level will change  every 30 milliseconds when the Dim Command is received  A  value of 255 would mean that the level would change every  2 55 seconds  Combined  the two parameters allow dim rate  adjustments from 10 milliseconds to 4 2 minutes to go   from maximum to minimum or minimum to maximum  brightness levels        1  When Receiving a Z Wave Dim Command    Parameter 7  number of steps or levels      Parameter 8  timing of the steps      Length  1 Byte      Valid Values   Parameter 7  default   1  Valid Values  1 99  Parameter 8  default   3  Valid Values  1 255    2  Manual Control Dimming  pressing the Dimmer s rocker     Parameter 9  number of steps or levels      Parameter 10  timing of the steps      Length  1 Byte    Valid Values   Parameter 9  default   1  Valid Values  1 99  Parameter 10  default   3  Valid Values  1 255       3  When Receiving an All On or All Off Command     Parameter 11  number of steps or levels      Parameter 12  timing of the steps      Length  1 Byte     Valid Values    Parameter 11  default   1  Valid Values  1 99   Parameter 12  default   3  Valid Values  1 255   Ignore Start Level When Receiving Dim Commands  Please note  Every    Dim    command includes a start level  embedded in it     The 45607 can be set to ignore the start level that is part of the  dim command  Setting parameter 5 to a value of 0 will cause  the 45607 to dim or brighten from the start level embedded in  
16. use interference and limit Z Wave functionality  Many 900MHz  products have a switch to select channel  A  or  B   You may find that  one of these channels will cause less interference than the other     IMPORTANT NOTE ABOUT 3 WAY CIRCUITS   The term    3 way circuit  refers to a circuit with two  switches and one load  light  like you find at the top and  bottom of a stairway  There are many ways to physically  wire a 3 way circuit and it is important to understand how  he circuit you wish to upgrade to Z Wave control is wired   Below is a description of a typical 3 way circuit    One of the ways to wire a two switch one load circuit is      route the incoming power through the first switch  then  o the second switch and then to the load  Although very  common and by no means a standard  it is the easiest      convert to Z Wave control  With this type of circuit   Switch 1 is replaced by the Z Wave auxiliary switch and  Switch 2 is replaced with the primary Z Wave dimmer  switch  The auxiliary switch does not actually control   he power  instead  it sends a momentary voltage signal  hrough the traveler wire to the primary switch which in  urn  controls the power to the load  In the configuration  shown  if the two Z Wave switches are reversed  Z Wave  Dimmer Switch will not be able to control the load without  additional wiring        Typical 3 way circuit    Black Black       Black       Colored NOT GREEN                    Switch 1  White          Switch 2       Correct sw
17. y switch is used     Please note  The 45610 Auxiliary Switch must be used with the  45607 Dimmer Switch in three way installations  Two Auxiliary  switches must be used in four way installations     Wiring Digram    Hot  Black                 Dimmer  Switch        Auxiliary  Switch                One Auxiliary  Switch for  3 way  installation                       Ground   Green     Neutral           White   Hot  Black   Yellow  156 10  Switches for away Suen     installation              Green    Up to 2 Auxiliary switches may be used to  create a 4 way installation    Single  Dual and Triple Gang Boxes    The metal plate surrounding the switch assembly is a heat sink   The maximum load rating  500W  is provided when installed in a  single gang box with the full heat sink  Multiple 45607 Dimmer  Switches may be installed in dual or triple gang boxes and  if  necessary  one or both sides of the heat sink may be removed  by bending it at the score lines  There is a corresponding  reduction in the switch   s load rating when ganged  DO NOT    exceed the following loads     Dimmer Rating   Number of Dimmers    500W One Dimmer in a Single  Gang Box   400W Two Dimmers in a Double  Gang Box   300W Three Dimmers in a Triple    Gang Box    Heat Sink  Full    One side removed    Both sides removed    Traveler    White  Colored not green      Neutral            Yellow         Traveler                     iners              ODE    Black   HOT or Load          HOT or Load         Ground 
    