Home

Jasco 15305 Instruction Manual

image

Contents

1. INSTRUCTIONS WALL BOX TIME SWITCH CAUTION a Installation by a licensed electrician is recommended Installation and use of this equipment should be in accordance with provisions of the U S National Electrical Code applicable local codes and pertinent industry standards These timers are not to be used in precision timing applications when inaccurate timing could have dangerous consequences such as with sun lamps or in tanning booths Do not use to control receptacles For indoor use only unless installed in a NEMA type 3R enclosure Use only copper wire Specifications 20A 125VAC General Purpose 10A 250VAC General Purpose 10A 277VAC General Purpose c UL US 7A 125VAC Tungsten 1HP 125VAC 1HP 250VAC Installation Instructions This GE Spring Wound Timer is easy to install and will fit in any standard 2 1 2 inch deep wall box Timer fits both toggle switch and rocker decorator switch applications in a single or multi gang vertically installed box setup Timer will work in single pole 3 Way or reverse acting applications If you are unsure about the installation of this timer please contact a licensed electrician Turn power off at circuit breaker or fuse box before installation Remove current wall plate and current switch from vertically installed wall box Wires should be stripped 5 16 inch long Wire Strip gauge on back of timer may be used to measure 5 16 inch Attach wires to timer by sliding the stripped end of
2. the wires into the timer terminals Be sure and note the proper wiring for your particular application See Applications section of this manual for more information Screw terminals down tight to secure the wires to the timer See Image Below 5 Attach ground wire green to bare ground in wire box Use included wire nut and twist together see image of typical SPST installation Typical SPST Installation Ground Green or Bare Secure together with a wire nut TN o ae Hot Line Side 1 Ground Wire Neutral White Secure with a wire nut if applicable Note Ground and Neutral are not used by the timer 6 Insert timer into the 2 1 2 wall box being careful not to pinch any wires Be sure the TOP indicated on front of timer is facing up Fasten the timer to the wall box using the screws provided 7 Place provided metal wall plate on timer referring to the appropriate diagram below Wire Terminal NOTE When using the provided wall plate screws are not required in order to secure the wall plate The nut will hold the wall plate in position once assembled 8 Carefully screw on the provided nut 9 Push timer knob onto knob extension Be sure the pointer is lined up with OFF on dial plate 10 Turn power on at the circuit breaker or fuse box Operating Instructions Turn knob clockwise to desired time period Timer will automatically turn current off at end of period Applications This
3. timer has multiple pole configurations including SPST SPDT 3 Way and DPST Please see below for an explanation SPST Lighting Fans A C Units Small Appliances SPDT Hallways Multi Levels Large Rooms SPDT Wiring Example Wiring Nut Black SPST Wiring Example Wiring Nut Black 120 VAC Light Power Source 120 277 VAC Power Source For 3 Way Applications a jumper wire must be connected from Line 1 to Line 2 This is represented by the dashed line in the above diagram REVERSE ACTING Load always on except when timer is engaged SPST Wiring Example Wiring Nut Black Spring Wound Timer 1 Black 120 VAC Power Source 15304 Manual 04 08 10 www jascoproducts com timer

Download Pdf Manuals

image

Related Search

Related Contents

File  User manual for user portal  Samsung 1¨¬  Pour télécharger la présentation détaillée du kit  Service Manual - Champion Power Equipment  BD ベリター システム Strep A  

Copyright © All rights reserved.
Failed to retrieve file